Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “prototype”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Prototype equation of state for phase transition of confined fluids based on the generalized van der Waals partition function

A simple self-consistent prototype equation of state (EOS) based on the Generalized van der Waals (vdW) partition function has been demonstrated to describe the phase transition of simple fluids in nanopores with uniform size. Different from those commonly presented in the literature, the new EOS does not need an auxiliary equation that is conventionally applied to provide the capillary pressure derived from surface tension. Lastly, the encouraging performance of the EOS calls for further extension to applications with more complex fluids and porous media.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and implementation of a prototype infrared video bolometer (IRVB) in MAST Upgrade

A prototype infrared video bolometer (IRVB) was successfully deployed in the Mega Ampere Spherical Tokamak Upgrade (MAST Upgrade or MAST-U), the first deployment of such a diagnostic in a spherical tokamak. The IRVB was designed to study the radiation around the lower x-point, another first in tokamaks, and has the potential to estimate emissivity profiles with spatial resolution beyond what is achievable with resistive bolometry. The system was fully characterized prior to installation on MAST-U, and the results are summarized here. After installation, it was verified that the actual measurement geometry in the tokamak qualitatively matches the design; this is a particularly difficult process for bolometers and was done using specific features of the plasma itself. The installed IRVB measurements are consistent both with observations from other diagnostics, including magnetic reconstruction, visible light cameras, and resistive bolometry, as well as with the IRVB-designed view. Early results show that with conventional divertor geometry and only intrinsic impurities (for example, C and He), the progression of radiative detachment follows a similar path to that observed for large aspect ratio tokamaks: The peak of the radiation moves along the separatrix from the targets to the x-point and high-field side midplane with a toroidally symmetric structure that can eventually lead to strong effects on the core plasma inside the separatrix.

47 OTHER INSTRUMENTATION↗

Density drop at the divertor target in the prototype material plasma exposure eXperiment (Proto-MPEX)

The steady-state linear device “Material Plasma Exposure eXperiment” (MPEX) is currently under construction at Oak Ridge National Laboratory with the goal of enabling Plasma-Material Interaction studies at future fusion reactor relevant plasma conditions. In this work, a newly in-house developed hybrid Particle-In-Cell code-PICOS++ is applied to understand the experimental results obtained from the prototype of MPEX referred to as the “Proto-MPEX” during its helicon-only and helicon with ion cyclotron resonance heating (ICRH) experiments. This study explains the physics of the experimentally observed plasma density-drop at the divertor target in Proto-MPEX device during ICRH. In contrast to previous work on ICRH in MPEX, this study demonstrates that the mirror force plays a central role in the Proto-MPEX plasma transport during ICRH, which has new features not previously explored. Force balance analyses reveal that the temperature anisotropy produced by ICRH leads to a significant increase in the mirror force downstream of the resonance where the magnetic field is diverging. This force accelerates ions toward the target and leads to a drop in plasma density to ensure conservation of particle flux. Simulations with ICRH where the magnetic field divergence downstream of the resonance has been removed, do not produce plasma acceleration nor density drop at the target despite efficient ion heating at the resonance. Moreover, simulation results demonstrate that for a given ICRH power, lowering the source rate produces ions with increased perpendicular energy which interact with the mirror force to produce higher plasma acceleration which increases the strength of the density-drop at the target. The strength of the density drop appears to reach an asymptotic limit at a certain threshold ICRH power. Simulations show that this threshold power increases with increasing particle source rate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Many roads to the seam: How conformational flexibility drives nonadiabatic relaxation in a prototypical tetrapyrrolic chromophore

Large and structurally flexible chromophores pose challenges for in silico modeling of photodeactivation due to the many vibrational modes that can funnel the system toward energy degeneracy. In this work, we examine how the multiple degrees of freedom in biliverdin, a prototypical tetrapyrrolic chromophore, cooperate to drive access to the S 1 /S 0 intersection seam in vacuo. We begin by mapping the ground-state potential energy surface to identify representative biliverdin conformers relevant to photoexcitation. We then use a CASSCF-based framework to map the excited-state landscape and characterize the intersection seam, identifying distinct conical-intersection types. Finally, we employ ab initio multiple spawning to resolve the dynamical pathways by which the system accesses these regions. DFT potential-energy and free-energy mappings indicate that, although several conformers are relevant, the “locked-helix” ZsZsZs conformer predominates in the ground state. The intersection seam comprises numerous geometrically distinct regions characterized by varying degrees and combinations of dihedral torsion, pyramidalization, and bond-length alternation. Yet only select regions lie within energetic reach, and moderate barriers separate them from the S 1 minimum. Nonadiabatic dynamics combined with multivariate analyses show that, despite extensive mode coupling during deactivation that guides the system toward multiple regions of the seam, a single dihedral torsion, together with bond-length alternation, predominantly drives energy degeneracy. This work offers new insight into biliverdin’s intrinsic photochemical response and underscores a general feature of flexible chromophores: many modes may participate during photorelaxation, but only a limited subset ultimately dictates seam accessibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pressure drop in a prototypical 3D magnetohydrodynamic flow across contraction of a fusion blanket manifold

Predicting 3D magnetohydrodynamic (MHD) pressure losses associated with liquid metal flows in complex geometry ducts is required to design breeding blankets for fusion reactors. Of such components, manifolds exhibit major pressure losses. Recent correlations [T. Rhodeset al. Magnetohydrodynamic pressure drop and flow balancing of liquid metal flow in a prototypic fusion blanket manifold. Phys. Fluids. 2018; 30: 057101.] demonstrate promise for predicting pressure drops in electrically insulated inlet manifolds. In the present work, the extend to which these correlations can be applied to outlet manifolds, which feature sudden contractions, is investigated in both viscous-electromagnetic (VE) and inertial-electromagnetic (IE) regimes for Reynolds numbers 50 < Re < 1500, Hartmann numbers 2500 < Ha < 5475, and expansion/contraction ratio 10. Numerical computations have shown that the MHD pressure drops in the eutectic lead-lithium (PbLi) flows in contractions are almost identical to those in the flows featuring expansion with slightly higher magnitudes in the contraction cases. The small discripancy in the MHD pressure drop between contractions and expansions (<8%) suggests that the earlier obtained correlations for the 3D MHD pressure drop in a duct flow with a sudden expansion can also be applied to flows with a sudden contraction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Relevance of Tritium Breeder Irradiation Testing in a Fusion Prototypic Neutron Source

A fusion prototypic neutron source (FPNS) will play a fundamental role in testing and developing fusion materials that can withstand the harsh fusion environment. We conducted a thorough assessment to determine whether blanket materials would benefit from FPNS testing. Because of the cross sections for the various blanket materials, lithium-containing materials can generally be tested adequately using existing fission irradiation capabilities instead of waiting for or relying solely on future FPNS experiments. However, non-lithium blanket materials, such as beryllium multipliers and flow channel inserts, should be tested under a fusion neutron spectrum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toward full simulations for a liquid metal blanket: part 2. Computations of MHD flows with volumetric heating for a PbLi blanket prototype at Ha ~10 4 and Gr ~10 12

On the pathway toward full simulations for a liquid metal (LM) blanket, this part 2 extends a previous study of purely magnetohydrodynamic (MHD) flows in a DCLL blanket in reference Chen et al (2020 Nucl. Fusion 60 076003) to more general conditions when the MHD flow is coupled with heat transfer. The simulated prototypic blanket module includes all components of a real LM blanket system, such as supply ducts, inlet and outlet manifolds, multiple poloidal ducts and a U-turn zone. Volumetric heating generated by fusion neutrons is added to simulate thermal effects in the flowing lead–lithium (PbLi) breeder. The MHD flow equations and the energy equation are solved with a DNS-type finite-volume code ‘MHD-UCAS’ on a very fine mesh of 470 × 10 6 cells. The applied magnetic field is 5 T (Hartmann number Ha ~ 10 4 ), the PbLi velocity in the poloidal ducts is 10 cm s –1 (Reynolds number Re ~10 5 ), whereas the maximum volumetric heating is 30 MW m –3 (Grashof number Gr ~ 10 12 ). Four cases have been simulated, including forced- and mixed-convection flows, and either an electrically conducting or insulating blanket structure. Various comparisons are made between the four computed cases and also against the purely MHD flows computed earlier in reference Chen et al (2020 Nucl. Fusion 60 076003) with regards to the (1) MHD pressure drop, (2) flow balancing, (3) temperature field, (4) flows in particular blanket components, and (5) 3D and turbulent flow effects. The strongest buoyancy effects were found in the poloidal ducts. In the electrically non-conducting blanket, the buoyancy forces lead to significant modifications of the flow structure, such as formation of reverse flows, whereas their effect on the MHD pressure drop is relatively small. In the electrically conducting blanket case, the buoyancy effects on the flow and MHD pressure drop are almost negligible.

Physics↗

Beam test performance of prototype silicon detectors for the Outer Tracker for the Phase-2 Upgrade of CMS

A new CMS tracker detector will be installed for operation at the High Luminosity LHC (HL-LHC). This detector comprises modules with two closely spaced parallel sensor plates and front-end ASICs capable of transmitting tracking information to the CMS Level-1 (L1) trigger at the 40 MHz beam crossing rate. The inclusion of tracking information in the L1 trigger decision will be essential for selecting events of interest efficiently at the HL-LHC. The CMS Binary Chip (CBC)has been designed to read out and correlate hits from pairs of tracker sensors, forming so called track stubs. For the first time, a prototype irradiated module and a full-sized module, both equipped with the version 2 of the CBC, have been operated in test beam facilities. The efficiency of the stub finding logic of the modules for various angles of incidence has been studied. The ability of the modules to reject tracks with transverse momentum less than 2 GeV has been demonstrated. For modules built with irradiated sensors, no significant drop in the stub finding performance has been observed. Results from the beam tests are described in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The BDX detector prototype for dark matter searches in a Beam Dump eXperiment at JLAB

The Beam Dump eXperiment (BDX) is an electron-beam thick-target experiment aimed to investigate the existence of light dark matter particles in the MeV-GeV mass range at Jefferson Lab. A small-scale prototype (BDX-Proto) of the BDX detector has been constructed in order to validate the proposed design and to demonstrate with real measurements the capability to efficiently reject the cosmogenic backgrounds. Here we report the peformance of BDX-Proto extracted from a long campaign of cosmic ray measurements performed at INFN, Sez. Catania and INFN, LNS.

calorimeters↗

Performance of a Front End prototype ASIC for picosecond precision time measurements with LGAD sensors

For the High-Luminosity phase of LHC, the ATLAS experiment is proposing the addition of a High Granularity Timing Detector (HGTD) in the forward region, to mitigate the effects of the increased pile-up. The chosen detection technology is Low Gain Avalanche Detector (LGAD) silicon sensors that can provide an excellent timing resolution below 50 ps. The front-end read-out ASIC must exploit the large signal derivative and small noise provided by the sensor, while keeping low power consumption. This paper presents the results on the first prototype of a front-end ASIC, named ALTIROC0, which contains the analog stages (preamplifier and discriminator) of the read-out chip. The ASIC was characterised both alone and as part of a module with a 2×2 LGAD array of 1.1×1.1 mm 2 pads bump-bonded to it. The various contributions of the electronics to the time resolution were investigated in test-bench measurements with a calibration setup. Both when the ASIC is alone or with a bump-bonded sensor, the jitter of the ASIC is better than 20 ps for an injected charge of 10 fC. The time walk effect, which arises from the different preamplifier response for various injected charges, can be corrected up to 10 ps using a Time Over Threshold measurement. The combined performance of the ASIC and the LGAD sensor, which was measured during a beam test campaign in October 2018 with pions of 120 GeV energy at the CERN SPS, is around 40 ps for all measured modules. All tested modules show good efficiency and time resolution uniformity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the CMS Endcap Timing Layer readout chip prototype with charge injection

We present the characterization of a readout Application-Specific Integrated Circuit (ASIC) for the CMS Endcap Timing Layer (ETL) of the High-Luminosity LHC upgrade with charge injection. The ASIC, named ETROC and developed in a 65 nm CMOS technology, reads out a 16× 16 pixel matrix of the Low-Gain Avalanche Detector (LGAD). The jitter contribution from ETROC is required to be below 40 ps to achieve the 50 ps overall time resolution per hit. The analog readout circuits in ETROC consist of the preamplifier and the discriminator. The preamplifier handles the LGAD charge signal with the most probable value of around 15 fC. The discriminator generates the digital pulse, which provides the Time-Of-Arrival (TOA, leading edge) and Time-Over-Threshold (TOT, pulse width) information. The prototype of ETROC (ETROC0) that implements a single channel of analog readout circuits has been evaluated with charge injection. The jitter of the analog readout circuits, measured from the discriminator's leading edge, is better than 16 ps for a charge larger than 15 fC with the sensor capacitance. The time walk resulting from different pulse heights can be corrected using the TOT measurement. The time resolution distribution has a standard deviation of 29 ps after the time-walk correction from the charge injection. At room temperature, the preamplifier's power consumption is measured to be 0.74 mW and 1.53 mW per pixel in the low- and high-power mode, respectively. Finally, the measured power consumption of the discriminator is 0.84 mW per pixel. With the ASIC alone or the LGAD sensor, The characterization performances fulfill the ETL's challenging requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of Michigan sMDT prototype chambers for the HL-LHC ATLAS muon detector upgrade

A new small-diameter Monitored Drift Tube (sMDT) chamber has been developed for the muon spectrometer of the ATLAS experiment to handle the higher collision rates expected at the CERN High Luminosity Large Hadron Collider (HL-LHC). This paper presents measurements of the tracking resolution and hit efficiency of two prototype sMDT chambers constructed at the University of Michigan. Using cosmic-ray muons the sMDT tracking resolution of 103.7 ± 8.1 μm was measured for one chamber and 101.8 ± 7.8 μm for the other, compared with a design resolution of 106 μm. A further tracking resolution improvement to 83.4 ± 7.8 μm was obtained by using new high-gain readout electronics which will be added for HL-LHC. An average tracking efficiency of (98.5 ± 0.2)% was found for both chambers. The methodology used to determine the detector tracking resolution and efficiency, including reconstruction of sMDT data and a Geant4 simulation of the test chamber, is presented in detail.

43 PARTICLE ACCELERATORS↗

Readout electronics for the CMS Phase II Endcap Calorimeter: system overview and prototyping experience

Abstract The frontend readout system for the silicon section of the CMS Phase II Endcap Calorimeter faces unique challenges due to the high channel count and associated bandwidth, limited physical space, as well as radiation tolerance requirements. I will give an overview of the frontend electronics design and will discuss the recent experience obtained from the first test system that integrates the HGCROC2 readout ASIC, lpGBT, and VTRX+ in a realistic manner, linking together prototypes of the hexaboard, engine, and wagon boards.

Instruments & Instrumentation↗

Timing Performance of the CMS High Granularity Calorimeter Prototype

This paper describes the experience with the calibration,reconstruction and evaluation of the timing capabilities of the CMSHGCAL prototype in the beam tests in 2018. The calibrationprocedure includes multiple steps and corrections ranging from tensof nanoseconds to a few hundred picoseconds. The timing performanceis studied using signals from positron beam particles with energiesbetween 20 GeV and 300 GeV. The performance is studied as afunction of particle energy against an external timing reference aswell as standalone by comparing the two different halves of theprototype. The timing resolution is found to be 60 ps forsingle-channel measurements and better than 20 ps for full showersat the highest energies, setting excellent perspectives for theHGCAL calorimeter performance at the HL-LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber

We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH 4 ) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200–1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.

47 OTHER INSTRUMENTATION↗

ETROC1: the first full chain precision timing prototype ASIC for CMS MTD endcap timing layer upgrade

We present the design and characterization of the first fullchain precision timing prototype ASIC, named ETL Readout Chipversion 1 (ETROC1) for the CMS MTD endcap timing layer (ETL)upgrade. The ETL utilizes Low Gain Avalanche Diode (LGAD) sensors todetect charged particles, with the goal to achieve a time resolutionof 40–50 ps per hit, and 30–40 ps per track with hits from twodetector layers. The ETROC1 is composed of a 5 × 5 pixelarray and peripheral circuits. The pixel array includes a4 × 4 active pixel array with an H-tree shaped networkdelivering clock and charge injection signals. Each active pixel iscomposed of various components, including a bump pad, a chargeinjection circuit, a pre-amplifier, a discriminator, adigital-to-analog converter, and a time-to-digital converter. Thesecomponents play essential roles as the front-end link in processingLGAD signals and measuring timing-related information. Theperipheral circuits provide clock signals and readoutfunctionalities. The size of the ETROC1 chip is7 mm× 9 mm. ETROC1 has been fabricated in a 65 nmCMOS process, and extensively tested under stimuli of chargeinjection, infrared laser, and proton beam. The time resolution ofbump-bonded ETROC1 + LGAD chipsets reaches 42–46 ps per hit in thebeam test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam test performance studies of CMS Phase-2 Outer Tracker module prototypes

A new tracking detector will be installed as part of thePhase-2 upgrade of the CMS detector for the high-luminosity LHC era.This tracking detector includes the Inner Tracker, equipped withsilicon pixel sensor modules, and the Outer Tracker, consisting ofmodules with two parallel stacked silicon sensors. The Outer Trackerfront-end ASICs will be able to correlate hits from chargedparticles in these two sensors to perform on-module discriminationof transverse momenta (p$_{T}$). The p$_{T}$information is generated at a frequency of 40 MHz and will be usedin the Level-1 trigger decision of CMS. Prototypes of theso-called 2S modules were tested at the Test Beam Facility at DESYHamburg between 2019 and 2020. These modules use the finalfront-end ASIC, the CMS Binary Chip (CBC), and for the firsttime the Concentrator Integrated Circuit (CIC), optical readoutand on-module power conversion. In total, seven modules were tested,one of which was assembled with sensors irradiated with protons. Animportant aspect was to show that it is possible to read out modulessynchronously. A cluster hit efficiency of about 99.75 % wasachieved for all modules. The CBC p$_{T}$ discriminationmechanism has been verified to work together with the CIC andoptical readout. The measured module performance meets therequirements for operation in the upgraded CMS tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam

The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end application-specific integrated circuit (ASIC) designed for beam monitoring applications. The achieved timing resolution of a few nanoseconds enables the measurement of both the luminosity and the beam-induced background. The ASIC, called FBCM23, features six channels with adjustable shaping times, enabling in-field fine-tuning. Each ASIC channel outputs a single binary asynchronous signal encoding time-of-arrival and time-over-threshold information. The FBCM is based on silicon-pad sensors, with two sensor designs presently being considered. This paper presents the results of tests of the FBCM detector prototype using both types of silicon sensors with hadron, muon, and electron beams. Irradiated FBCM23 ASICs and silicon-pad sensors were also tested to simulate the expected conditions near the end of the detector's lifetime in the HL-LHC radiation environment. Based on test results, direct bonding between the sensor and ASIC was chosen, and an optimal bias voltage and ASIC threshold for FBCM operation were proposed. The current design of the front-end test board was validated following the beam test and is now being used for the first front-end module, which is expected to be produced in summer 2025. These results represent a major step forward in validating the FBCM concept, first version of the firmware and establishing a reliable design path for the final detector.

Beam-line instrumentation (beam position and profi↗