Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “program evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Toxicity of Irinotecan-Eluting Beads in the Treatment of Hepatic Malignancies: Results of a Multi-Institutional Registry

PurposeTo evaluate the predictors of toxicity of drug-eluting beads loaded with irinotecan (DEBIRI) in the treatment of hepatic malignancies.Materials and MethodsA total of 330 patients were enrolled in a prospective, open-label, multicenter, multinational, single-arm study administering two types of drug-eluting beads (DEBIRI and drug-eluting beads loaded with doxorubicin). Complications were graded by Cancer Therapy Evaluation Program's Common Terminology Criteria for Adverse Events (CTCAE) version 3.0. All events requiring additional physician treatment or requiring extended hospital stay or readmission within 30 days were included.ResultsA total of 109 patients received 187 DEBIRI treatments (range 1 to 5 per patient). The most common histology was metastatic colorectal cancer in 76% of patients, cholangiocarcinoma in 7% of patients, and other metastatic disease in 17% of patients. There were 35 patients (19%) with irinotecan treatments who sustained 158 treatment-related adverse events, with the median CTCAE event grade being CTCAE grade 2 (range 1 to 5). The most common adverse events were postembolic symptoms (42%). Multivariate analysis identified pretreatment and treatment-related risk factors as follows: lack of pretreatment with hepatic arterial lidocaine (p = 0.005), {>=}3 treatments (p = 0.05), achievement of complete stasis (p = 0.04), treatment with >100 mg DEBIRI in 1 treatment (p = 0.03), and bilirubin >2.0 {mu}g/dl with >50% liver involvement (p = 0.05). These factors were predictive of adverse events and significantly greater hospital length of stay.ConclusionsDEBIRI is safe when appropriate technique and treatment are used. Adverse events can be predicted based on pretreatment- and treatment-related factors, and their occurrence can become part of the informed consent process. Continued standardization of this treatment will lead to fewer adverse events and improved patient quality of life.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid fusion method for the determination of refractory thorium and uranium isotopes in soil samples

Recently, approximately 80% of participating laboratories failed to accurately determine uranium isotopes in soil samples in the U.S Department of Energy Mixed Analyte Performance Evaluation Program (MAPEP) Session 30, due to incomplete dissolution of refractory particles in the samples. Failing laboratories employed acid dissolution methods, including hydrofluoric acid, to recover uranium from the soil matrix. The failures illustrate the importance of rugged soil dissolution methods for the accurate measurement of analytes in the sample matrix. A new rapid fusion method has been developed by the Savannah River National Laboratory (SRNL) to prepare 1-2 g soil sample aliquots very quickly, with total dissolution of refractory particles. Soil samples are fused with sodium hydroxide at 600 ºC in zirconium crucibles to enable complete dissolution of the sample. Uranium and thorium are separated on stacked TEVA and TRU extraction chromatographic resin cartridges, prior to isotopic measurements by alpha spectrometry on cerium fluoride microprecipitation sources. Plutonium can also be separated and measured using this method. Batches of 12 samples can be prepared for measurement in <5 hours.

54 ENVIRONMENTAL SCIENCES↗

Dynamic Contrast-Enhanced MRI Kinetics of Invasive Breast Cancer: A Potential Prognostic Marker for Radiation Therapy

Purpose: Our goal was to determine the correlations between dynamic contrast-enhanced MRI (DCE-MRI) kinetics of breast cancers and axillary nodal status (ANS) which may have prognostic value in designing radiation therapy recommendations. Methods and Materials: A retrospective review identified 167 consecutive patients treated with external beam radiotherapy for invasive breast cancer from Jan 1, 2006 to Nov 1, 2007. Patients with DCE-MRI kinetic data from our institution who underwent axillary surgical staging prior to chemotherapy were included. ANS was assessed as positive or negative by pathology record review. For each primary cancer, maximum tumor diameter and kinetic values for initial peak enhancement (PE), percent initial rapid enhancement (RE), and percent delayed washout enhancement (WE) were measured with a computer-aided evaluation program. Univariate, multivariate, and receiver operating characteristic curve analyses were performed according to the ANS. Results: Forty-six patients met study criteria, with 32 (70%) node-negative and 14 (30%) node-positive patients. Median PE was significantly greater in node-positive patients (209%) than in node-negative patients (138%, p = 0.0027). Similarly, median RE was significantly greater in node-positive patients (57%) than in node-negative patients (27%, p = 0.0436). WE was not different between groups (p = 0.9524). Median maximum tumor diameter was greater in node-positive patients (26 mm) than in node-negative patients (15 mm, p = 0.015). Multivariate analysis showed that only PE trended toward significance (p = 0.18). Conclusions: DCE-MRI kinetics of primary breast cancers correlate with ANS. Multivariate analysis demonstrates the correlation is not due simply to underlying lesion size. If validated prospectively, DCE-MRI kinetics may aid as a tool in selecting patients or designing fields for radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Screening and Validation of Molecular Targeted Radiosensitizers

The development of molecular targeted drugs with radiation and chemotherapy is critically important for improving the outcomes of patients with hard-to-treat, potentially curable cancers. However, too many preclinical studies have not translated into successful radiation oncology trials. Major contributing factors to this insufficiency include poor reproducibility of preclinical data, inadequate preclinical modeling of intertumoral genomic heterogeneity that influences treatment sensitivity in the clinic, and a reliance on tumor growth delay instead of local control (TCD50) endpoints. There exists an urgent need to overcome these barriers to facilitate successful clinical translation of targeted radiosensitizers. To this end, we have used 3-dimensional (3D) cell culture assays to better model tumor behavior in vivo. Examples of successful prediction of in vivo effects with these 3D assays include radiosensitization of head and neck cancers by inhibiting epidermal growth factor receptor or focal adhesion kinase signaling, and radioresistance associated with oncogenic mutation of KRAS. To address the issue of tumor heterogeneity, we leveraged institutional resources that allow high-throughput 3D screening of radiation combinations with small-molecule inhibitors across genomically characterized cell lines from lung, head and neck, and pancreatic cancers. This high-throughput screen is expected to uncover genomic biomarkers that will inform the successful clinical translation of targeted agents from the National Cancer Institute Cancer Therapy Evaluation Program portfolio and other sources. Screening “hits” need to be subjected to refinement studies that include clonogenic assays, addition of disease-specific chemotherapeutics, target/biomarker validation, and integration of patient-derived tumor models. The chemoradiosensitizing activities of the most promising drugs should be confirmed in TCD50 assays in xenograft models with or without relevant biomarker and using clinically relevant radiation fractionation. We predict that appropriately validated and biomarker-directed targeted therapies will have a higher likelihood than past efforts of being successfully incorporated into the standard management of hard-to-treat tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toxicokinetics and toxicity of atorvastatin in dogs

HMG-CoA reductase inhibitors (e.g., statins) are an important clinical option to lower cholesterol and treat co-morbidities. Atorvastatin is the most prescribed statin and has obtained generic status. We recently had a clinical development program evaluating a combination of atorvastatin with a GPR119 agonist as a treatment for dyslipidemia, where toxicological evaluations in dogs were completed. There were several challenges related to selecting doses for atorvastatin, including understanding the dose–exposure relationship from different drug forms used by the innovator in their general toxicology studies, bioanalytical assays that did not separate and quantify parent from metabolites, and high variability in the systemic exposures following oral dosing. The studies in this report characterized the toxicokinetics and toxicity of atorvastatin in the dog for up to 13-weeks. Overall, there were no notable differences in the toxicokinetics of atorvastatin or the two active hydroxylated metabolites between the sexes at Week 13. However, systemic exposures were markedly lower at Week 13 compared to that observed at Week 4, suggesting induction of metabolism or reduced absorption from the gastrointestinal tract following oral dosing. Changes in laboratory chemistries included increased liver enzyme levels and lower cholesterol levels. Histopathologic evaluation revealed multifocal minimal to slight hemorrhages in the submucosa of the gallbladder; all findings were reversible. The information from these studies along with the existing clinical experience with atorvastatin can be used to design robust toxicology studies in dogs and reduce animal use. - Highlights: • Atorvastatin is given to reduce cholesterol and is available as a generic drug. • Co-dosing of multiple products to treat hypercholesterolemia is increasing. • This work characterized the toxicokinetics and toxicity of atorvastatin in dogs. • The toxicokinetics of two hydroxylated metabolites were determined. • Recommendations on the dose–exposure relationship in dog are provided.

60 APPLIED LIFE SCIENCES↗

Modeling the potential effects of rooftop solar on household energy burden in the United States

Policymakers at the federal and state level have begun to incorporate energy burden into equity goals and program evaluations, aiming to reduce energy burden below a high level of 6% for lower income households in the United States. Pairing an empirical household-level dataset spanning United States geographies together with modeled hourly energy demand curves, we show that rooftop solar reduces energy burden across a majority of adopters during our study period from a median of 3.3% to 2.6%. For low- and moderate-income adopters (at or below 80% and 120% of area median income, respectively), solar reduces median 2021 energy burden from 7.7% to 6.2%, and 4.1% to 3.3%, respectively. Importantly, solar reduces the rate of high or severe energy burden from 67% of all low-income households before adoption to 52% of households following adoption, and correspondingly from 21% to 13% for moderate-income households. Here, we show rooftop solar can support policy goals to reduce energy burden along with strategies such as weatherization and bill assistance.

14 SOLAR ENERGY↗

Comparative evaluation of analogue front-end designs for the CMS Inner Tracker at the High Luminosity LHC

The CMS Inner Tracker, made of silicon pixel modules, will be entirely replaced prior to the start of the High Luminosity LHC period. One of the crucial components of the new Inner Tracker system is the readout chip, being developed by the RD53 Collaboration, and in particular its analogue front-end, which receives the signal from the sensor and digitizes it. Three different analogue front-ends (Synchronous, Linear, and Differential) were designed and implemented in the RD53A demonstrator chip. A dedicated evaluation program was carried out to select the most suitable design to build a radiation tolerant pixel detector able to sustain high particle rates with high efficiency and a small fraction of spurious pixel hits. The test results showed that all three analogue front-ends presented strong points, but also limitations. The Differential front-end demonstrated very low noise, but the threshold tuning became problematic after irradiation. Moreover, a saturation in the preamplifier feedback loop affected the return of the signal to baseline and thus increased the dead time. The Synchronous front-end showed very good timing performance, but also higher noise. For the Linear front-end all of the parameters were within specification, although this design had the largest time walk. This limitation was addressed and mitigated in an improved design. The analysis of the advantages and disadvantages of the three front-ends in the context of the CMS Inner Tracker operation requirements led to the selection of the improved design Linear front-end for integration in the final CMS readout chip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ANALYSIS OF SUITABLE METHODOLOGIES FOR COMPRESSOR MASS FLOW RATE CORRECTION TO OTHER SUPERHEAT LEVELS AND REFRIGERANTS

This paper investigates the impact of suction conditions and refrigerant on scroll compressor mass flow rate by using calorimeter tests from AHRI-11 and AHRI-21 reports, published by AHRI's Low-GWP Alternative Refrigerants Evaluation program. Two Copeland scroll compressors (20 and 51 cm3) have been analyzed including different suction conditions (SH = 11K, SH = 22K, Ti = 18ºC) and several refrigerants (R134a, R32, R410A, R404A, etc.). Previous studies have explored response surfaces for energy consumption and mass flow rate variables. This study aims to expand the analysis by identifying the optimal approach to extrapolate mass flow rate from specific suction conditions to others SH or suction temperature levels and refrigerants. The current compressor characterization standard relies on the 1981 Dabiri correlation to correct compressor mass flow rate with suction conditions. Thus, this study aims to assess the adequacy of this correction and explore alternative correction methods for improved results.

Marchante Avellaneda, Javier↗

INL Seismic Monitoring Annual Report: January 1, 2010 – December 31, 2010

During 2010, the INL Seismic Monitoring Program evaluated 11,606 earthquakes from around the world, the western United States, and local region of the eastern Snake River Plain (ESRP). INL located 2,085 earthquakes and man-made blasts within the local region outside and within a 161-km (or 100-mile) radius of INL. Of these events, 53 were small-to-moderate size earthquakes ranging in magnitude from 3.0 to 4.8. 672 earthquakes occurred within the 161-km radius of INL and the majority of these earthquakes were located in active regions of the Basin and Range Province that surrounds the ESRP. There were 10 microearthquakes within the boundary of the ESRP, all of magnitude less than or equal to 2.0. Five of those were located within and near the ESRP at Craters of the Moon National Monument (COM) at mid- and lower-crust depths and are interpreted to be related to fluid movement. Since 1972, INL has recorded 48 small-magnitude, microearthquakes (M = 2.2) within the ESRP (not including COM events) and 22 deep microearthquakes (M = 2.3) in the vicinity of Craters of the Moon National Monument.

58 GEOSCIENCES↗

Selective stress-based microcantilever sensors for enhanced surveillance

Assessment of component aging and degradation in weapon systems remains a considerable challenge for the Integrated Stockpile Evaluation program. Analysis of weapon atmospheres can provide degradation signatures and indicate the presence of corrosive vapors. However, a critical need exists for compatible in-situ sensors to detect moisture and other gases over stockpile lifetimes. This inhibits development of both “self-aware weapons” and fully instrumented weapon test platforms that could provide in-situ data to validate high-fidelity models for gases within weapons. We developed platforms for on-demand weapon atmosphere surveillance based on static microcantilevers (SMC) and surface accoustic wave (SAW) devices coated with nanoporous metal organic frameworks (MOFs) to provide selectivity.

Allendorf, Mark D.↗

INL Seismic Monitoring Annual Report: January 1, 2011 - December 31, 2011

During 2011, the Idaho National Laboratory Seismic Monitoring Program evaluated 21,928 independent triggers that included earthquakes from around the world, the western United States, and local region of the Snake River Plain. Seismologists located 2,063 earthquakes and man-made blasts within and near the 161-km (or 100-mile) radius of the Idaho National Laboratory. Of these events, 16 were small-to-moderate size earthquakes ranging in magnitude (M) from 3.0 to 4.4. Within the 161-km radius, the majority of 941 earthquakes (M < 4.4) occurred in the active regions of the Basin and Range Province with only six microearthquakes occurring in the Snake River Plain. In the northern and southeastern Basin and Range, eight earthquake swarms occurred and included over 325 events. Five of the Snake River Plain earthquakes were located within and near the northern and southern ends of the Great Rift volcanic rift zone. All have anomalously deep focal depths (16 to 38 km) and waveforms indicative of fluid movement at mid- and lower-crustal levels and are a continuation of activity observed at Craters of the Moon National Monument since 2007. Since 1972, the Idaho National Laboratory has recorded 55 small-magnitude microearthquakes (M ≤ 2.2) within the eastern Snake River Plain and 25 deep microearthquakes (M ≤ 2.3) in the vicinity of Craters of the Moon National Monument.

58 GEOSCIENCES↗

TEST REPORT #21: Compressor Calorimeter Test of R-404A Alternatives ARM-31a, D2Y-65, L-40, and R32/ R-134a (50/50)

As a contribution to the AHRI Low-GWP Alternative Refrigerants Evaluation Program (AREP), this study compares the performance of four lower-GWP alternative refrigerants, ARM-31a, D2Y-65, L-40, and R-32 + R-134a mixture, to that of refrigerant R-404A (baseline) in a scroll compressor designed for medium temperature refrigeration applications. These comparisons were carried out via compressor calorimeter tests performed on a compressor designed for refrigerant R-404A and having a nominal rated capacity of 23,500 Btu/hr. Tests were conducted over a suction dew point temperature range of -10°F to 35°F in 5°F increments and a discharge dew point temperature range of 70°F to 140°F in 10°F increments. All the tests were performed with 20°F superheat, 40°F superheat, and 65°F suction temperature. A liquid subcooling level of 10°F to 15°F was maintained for all the test conditions. However, the cooling capacities reported in this study are normalized for 0°F subcooling. The tests showed that the compressor energy efficiency ratio (EER) and cooling capacity with all four alternative refrigerants tested are higher at higher saturation suction and saturation discharge temperature and lower at lower saturation suction and saturation discharge temperature, compared to that of R-404A. Discharge temperatures of all the alternative refrigerants were higher than that of R-404A at all test conditions.

Alternative Refrigerants↗

Determining Remaining Useful Life of Aging Cables in Nuclear Power Plants – Interim Study FY13

The most important criterion for cable performance is its ability to withstand a design-basis accident. With nearly 1000 km of power, control, instrumentation, and other cables typically found in an NPP, it would be a significant undertaking to inspect all of the cables. Degradation of the cable jacket, electrical insulation, and other cable components is a key issue that is likely to affect the ability of the currently installed cables to operate safely and reliably for another 20 to 40 years beyond the initial operating life. The development of one or more nondestructive evaluation (NDE) techniques and supporting models that could assist in determining the remaining life expectancy of cables or their current degradation state would be of significant interest. The ability to nondestructively determine material and electrical properties of cable jackets and insulation without disturbing the cables or connections has been deemed essential. Currently, the only technique accepted by industry to measure cable elasticity (the gold standard for determining cable insulation degradation) is the indentation measurement. All other NDE techniques are used to find flaws in the cable and do not provide information to determine the current health or life expectancy. There is no single NDE technique that can satisfy all of the requirements needed for making a life-expectancy determination, but a wide range of methods have been evaluated for use in NPPs as part of a continuous evaluation program. The commonly used methods are indentation and visual inspection, but these are only suitable for easily accessible cables. Several NDE methodologies using electrical techniques are in use today for flaw detection but there are none that can predict the life of a cable. There are, however, several physical and chemical ptoperty changes in cable insulation as a result of thermal and radiation damage. In principle, these properties may be targets for advanced NDE methods to provide early warning of aging and degradation. Examples of such key indicators include changes in chemical structure, mechanical modulus, and dielectric permittivity. While some of these indicators are the basis of currently used technologies, there is a need to increase the volume of cable that may be inspected with a single measurement, and if possible, to develop techniques for in-situ inspection (i.e., while the cable is in operation). This is the focus of the present report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Compressor Calorimeter Test of R-410A Alternative: R-32/134a Mixture Using a Scroll Compressor

As a contribution to the AHRI Low-GWP Alternative Refrigerants Evaluation Program (AREP), this study compares the performance of lower-GWP alternative refrigerant R-32 + R-134a mixture, to that of refrigerant R-410A (baseline) in a scroll compressor designed for air-conditioning and heat pump applications. These comparisons were carried out via compressor calorimeter tests performed on a compressor designed for refrigerant R-410A and having a nominal rated capacity of 21,300 Btu/hr. Tests were conducted over a suction dew point temperature range of 10 F to 55 F in 5 F increments and a discharge dew point temperature range of 70 F to 140 F in 10 F increments. All the tests were performed with 20 F superheat, 40 F superheat, and 65 F suction temperature. A liquid subcooling level of 15 F was maintained for all the test conditions. The tests showed that the discharge temperature of the alternative refrigerant was higher than that of R-410A at all test conditions. Also, the energy efficiency ratio (EER) and cooling capacity of compressor using the alternative refrigerant were slightly lower in comparison to that of R-410A.

Alternative Refrigerants↗

A complexity science-based framework for global joint operations analysis to support force projection: LDRD Final Report

The military is undergoing a significant transformation as it modernizes for the information age and adapts to address an emerging asymmetric threat beyond traditional cold war era adversaries. Techniques such as traditional large-scale, joint services war gaming analysis are no longer adequate to support program evaluation activities and mission planning analysis at the enterprise level because the operating environment is evolving too quickly. New analytical capabilities are necessary to address modernization of the Department of Defense (DoD) enterprise. This presents significant opportunity to Sandia in supporting the nation at this transformational enterprise scale. Although Sandia has significant experience with engineering system of systems (SoS) and Complex Adaptive System of Systems (CASoS), significant fundamental research is required to develop modeling, simulation and analysis capabilities at the enterprise scale. This report documents an enterprise modeling framework which will enable senior level decision makers to better understand their enterprise and required future investments.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

INL Seismic Monitoring Annual Report: January 1, 2012 - December 31, 2012

During 2012, the Idaho National Laboratory Seismic Monitoring Program evaluated 17,329 independent triggers that included earthquakes from around the world, the western United States, and local region of the Snake River Plain. Seismologists located 1,460 earthquakes and man-made blasts within and near the 161-km (or 100-mile) radius of the Idaho National Laboratory. Of these earthquakes, 16 had small-to-moderate size magnitudes (M) from 3.0 to 3.6. Within the 161-km radius, the majority of 695 earthquakes (M < 3.6) occurred in the active regions of the Basin and Range Provinces adjacent to the eastern Snake River Plain. Only 11 microearthquakes occurred within the Snake River Plain, four of which occurred in Craters of the Moon National Monument. The earthquakes had magnitudes from 1.0 to 1.7 and occurred at deep depths (11-24 km). Two events with magnitudes less than 1.0 occurred within the Idaho National Laboratory boundaries and had depths less than 10 km.

58 GEOSCIENCES↗

Geothermal Exploration of Newberry Volcano, Oregon

Davenport Newberry (Davenport) has completed 8 years of exploration for geothermal energy on Newberry Volcano in central Oregon. Two deep exploration test wells were drilled by Davenport on the west flank of the volcano, one intersected a hydrothermal system; the other intersected isolated fractures with no hydrothermal interconnection. Both holes have bottom-hole temperatures near or above 315°C (600°F). Subsequent to deep test drilling an expanded exploration and evaluation program was initiated. These efforts have included reprocessing existing data, executing multiple geological, geophysical, geochemical programs, deep exploration test well drilling and shallow well drilling. The efforts over the last three years have been made possible through a DOE Innovative Exploration Technology (IET) Grant 109, designed to facilitate innovative geothermal exploration techniques. The combined results of the last 8 years have led to a better understanding of the history and complexity of Newberry Volcano and improved the design and interpretation of geophysical exploration techniques with regard to blind geothermal resources in volcanic terrain.

15 GEOTHERMAL ENERGY↗

LED Lighting in a Performing Arts Building

At the University of Florida in Gainesville, the DOE Solid-State Lighting GATEWAY program evaluated LED architectural and theatrical lighting in four academic/performance-related spaces within the Nadine McGuire Theatre + Dance Pavilion. Due to a wise choice of products and luminaire light distributions, the change brought significant quality improvements including improved controllability and color.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗