Preconceptual Designs of Coupled Power Delivery between a 4-Loop PWR and 100-500 MWe HTSE Plants

This study develops a preconceptual design for the integration between a large-scale high-temperature electrolysis facility and a NPP. Two hydrogen facility sizes are considered: 100 MWnom and 500 MWnom. Both steam supply designs use cold reheat steam extraction as a heat source. A reboiler inside the protected area of the power plant transfers steam heat to the demineralized water supply for the hydrogen plant. After the heat transfer, the extracted steam condenses and returns to the condenser while the process steam routes out of the protected area to the electrolyzers. Electrical power is tapped off from the high voltage side of the GSU transformer, where it is then transported via a 345-kV transmission line to the hydrogen facility. Circuit breakers and disconnects are located at both ends of the transmission line. Step down transformers and miscellaneous switchgear/buses are located at the end of the transmission line inside the HTEF boundary. Control capabilities for the steam interfacing equipment and electrical dispatch are accessible from the Main Control Room, and protective relays for the transmission line are located inside the Relay Room. Computer modeling was performed for the thermal and electrical designs. PEPSE analysis provided the steady-state parameters for thermal extraction from the turbine cycle. These parameters were used to inform transients and size equipment in combination with Applied Flow Technology (AFT) Arrow and AFT Fathom modeling for steam and water piping, respectively. Electrical transients were analyzed using PSCAD. An ETAP model was used to evaluate power flow and short circuit, which enabled the sizing of transformers and protective equipment. A cost estimate was developed for both integration designs when considering plant separation distances of 250 m and 500 m. From these estimates, the modifications for thermal and electrical interfacing of a first-of-a-kind nuclear-integrated hydrogen facility are anticipated to cost between $60–250/kWnom., where the subscript “nom” refers to the nominal size of the hydrogen plant. On a thermal power basis, the thermal power has a cost of approximately $8/MWth for a 500 MWnom high temperature electrolysis plant located 500 m distant from the NPP. That value decreases to approximately $7.5/MWth for a 250 m separation distance between the hydrogen plant and the NPP. This value is lower than previous estimates of the cost of heat extracted from NPPs primarily because in this work the steam is extracted from cold reheat instead of the main steam line, which reduces the cost of the dispatched steam by approximately $3.5/MWth. Nuclear steam extraction can provide a profit avenue for many plants and is not restricted to hydrogen production. Ammonia production, oil refining, and paper production, among other industrial processes all require thermal energy, which can be provided by NPPs. Future work should look further at the details of thermal extraction for a variety of use cases. This can include increased levels of extraction and multiple simultaneous users. Additionally, site-specific studies should be performed to develop industry experience and improve cost accuracy.

08 HYDROGEN↗

Challenges to Rural Service Transformers on Increased Electric Vehicle Charging Infrastructure

As Electric Vehicle (EV) electric charging demand increases so to does the corresponding load requirements for charging the vehicles. The expansion of power distribution assets is therefore a critical issue to address on whether rural service transformers can handle the increase in EV load demand. Large-scale EV deployment is likely to cause problems in the localized distributions systems bringing challenges such as increased load demand, increased system losses, and additional voltage drops. This paper investigates how rural service transformer resiliency plays an important role in these challenges. EV charging can create new load peaks exceeding the service transformer's rated capacity, thereby accelerating equipment aging. EV charging can also both positively and negatively affect transformer aging. The core purpose of this paper is to investigate that change in service life of rural service transformers.

Mukherjee, Srijib↗

Distribution Transformer Demand: Understanding Demand Segmentation, Drivers, and Management Through 2050

The National Renewable Energy Laboratory (NREL) has been working closely with the U.S. Department of Energy's Office of Electricity (OE) to understand the critical drivers and potential means of managing distribution transformer demand through 2050. This effort has consulted with utility representative organizations and transformer manufacturers to understand the problem, characterized the in-service assets, and modeled future demand. Distribution transformers, or service transformers, range from 10 to 5,000 kilovolt-amperes (kVA), have a high-side voltage of less than 34.5 kilovolts, and have step-down power delivery for customer end use. This research will help the manufacturing sector understand production requirements and better inform utility strategies for managing their demand.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Online Detection of Inter-Turn Winding Faults in Single-Phase Distribution Transformers Using Smart Meter Data

Turn-to-turn faults between primary windings due to insulation degradation are a major cause of distribution transformer failure, and occur due to high levels of stress such as overloading and overheating. An additional consequence of these faults is an increased voltage on the transformer secondary due to effective change in turns ratio. This paper develops a novel method for early detection of insulation degradation and subsequent inter-turn winding failure by monitoring the transformer secondary voltage. The algorithm is based on a cumulative sum (CUSUM) statistic and compares voltages on neighbouring transformers to flag degrading assets. Results obtained from simulation as well as experimental data show that smart meter measurements can be utilized to achieve very high detection accuracy while keeping costs low. Here, the paper also demonstrates the validity of the algorithm in the presence of measurement noise, residential solar power injection etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hardware Design of Medium Voltage SiC-Based Modular Multilevel Converters for Grid-Tied Applications

This paper presents a design of a 10 kV silicon carbide (SiC) MOSFET based modular multilevel converter (MMC). The MMC functions as the interconnection between a 24 kV dc bus and a 13. SkV distribution grid. This paper focuses on the hardware design of the MMC and its submodules. The gate driver, auxiliary power supply and bus bur in submodules are major components that need to meet high dv/dt immunity and high insulation voltage requirements. The gate driver achieves over 200 kV/us common mode transient immunity (CMTI). Its associated auxiliary power supply is based on an on-board transformer with over 30 kV insulation capability and 1.4 pF barrier capacitance. The busbar achieves less than 11 kV/cm electric field in the air to avoid partial discharges. Validation tests of the MMC submodule were performed by double pulse tests at 5 kV and buck converter tests at3 kV, 52A (peak). Reliable operations were achieved in validation tests.

auxiliary power supply↗

RingX: Scalable Parallel Attention for Long-Context Learning on HPC

The attention mechanism has become foundational for remarkable AI breakthroughs since the introduction of the Transformer, driving the demand for increasingly longer context to power frontier models such as large-scale reasoning language models and high-resolution image/video generators. However, its quadratic computational and memory complexities present substantial challenges. Current state-of-the-art parallel attention methods, such as ring attention, are widely adopted for long-context training but utilize a point-to-point communication strategy that fails to fully exploit the capabilities of modern HPC network architectures. In this work, we propose ringX, a scalable family of parallel attention methods optimized explicitly for HPC systems. By enhancing workload partitioning, refining communication patterns, and improving load balancing, ringX achieves up to 3.4 × speedup compared to conventional ring attention on the Frontier supercomputer. Optimized for both bi-directional and causal attention mechanisms, ringX demonstrates its effectiveness through training benchmarks of a Vision Transformer (ViT) on a climate dataset and a Generative Pre-Trained Transformer (GPT) model, Llama3 8B. Our method attains an end-to-end training speedup of approximately 1.5 × in both scenarios. To our knowledge, the achieved 38% model FLOPs utilization (MFU) for training Llama3 8B with a 1M-token sequence length on 4,096 GPUs represents one of the highest training efficiencies reported for long-context learning on HPC systems. Our code implementation is available at https://github.com/jqyin/ringX-attention.

Yin, Junqi [ORNL] (ORCID:0000000338435520)↗

Leveraging Existing Bioenergy Data: Workshop Summary Report

The U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) invests in a diverse portfolio of technologies to ensure domestic energy security, continued economic competitiveness, environmental sustainability, and the availability of cleaner fuels and power. The mission of EERE’s Bioenergy Technologies Office (BETO) is to develop transformative and revolutionary sustainable bioenergy technologies for a prosperous nation. BETO develops technologies that convert domestic biomass and waste resources into fuels, products, and power to enable affordable energy, economic growth, and innovation in renewable energy and chemicals production. This report summarizes the input received from attendees of the public workshop sponsored by BETO on July 21–23, 2020, as well as input received from a Request for Information (RFI) run in August and September 2019.

09 BIOMASS FUELS↗

A Class of Sparse Johnson–Lindenstrauss Transforms and Analysis of their Extreme Singular Values

The Johnson–Lindenstrauss (JL) lemma is a powerful tool for dimensionality reduction in modern algorithm design. The lemma states that any set of high-dimensional points in a Euclidean space can be projected into lower dimensions while approximately preserving pairwise Euclidean distances. Random matrices satisfying this lemma are called JL transforms (JLTs). Inspired by existing $s$-hashing JLTs with exactly $s$ nonzero elements on each column, the present work introduces an ensemble of sparse matrices encompassing so-called $s$-hashing-like matrices whose expected number of nonzero elements on each column is $s$. The independence of the sub-Gaussian entries of these matrices and the knowledge of their exact distribution play an important role in their analyses. Using properties of independent sub-Gaussian random variables, these matrices are demonstrated to be JLTs, and their smallest nontrivial singular values and largest singular values are estimated nonasymptotically using a technique from geometric functional analysis. As the dimensions of the matrix grow to infinity, these singular values are proved to converge almost surely to fixed quantities (by using the universal Bai–Yin law) and in distribution to the Gaussian orthogonal ensemble Tracy–Widom law after proper rescalings. Understanding the behaviors of extreme singular values is important in general because they are often used to define a measure of stability of matrix algorithms. For example, JLTs were recently used in derivative-free optimization algorithmic frameworks to select random subspaces in which are constructed random models or poll directions to achieve scalability, and hence estimating their smallest singular value in particular helps determine the dimension of these subspaces.

97 MATHEMATICS AND COMPUTING↗

Climate-Water Impacts on Interconnection-Scale Electricity System Planning

A growing literature emphasizes the importance of integrating climate change impacts into electricity system planning. Rising average temperatures can increase and shift electricity demand while reducing generator and transmission efficiency. Changes to water availability and quality can reduce the output of thermally cooled generators and hydropower. Electric power grids across the US and globally are undergoing transformational changes that present new opportunities and challenges to reliability assurance. However, electric utilities and system operators have limited internal capabilities to incorporate these effects into planning practices. This work addresses gaps in utility and system planner practices by integrating climate-water-electricity expertise from universities and U.S. Department of Energy National Laboratories with electricity system planners and stakeholders in the Western Electricity Coordinating Council (WECC). Using a highly collaborative approach, global climate model data, high-resolution hydrology models, and long-term electric sector capacity expansion tools are employed to analyze a range of climate outcomes for future electricity scenarios aligned with recent WECC planning studies. Doing so allows WECC to expand its climate-agnostic planning assessments to consider how future temperature and precipitation patterns could influence generation and transmission planning. We explore how changes to climate-water conditions can affect power plant investment and operation, system economics, and environmental impacts, providing an expanded perspective on interconnection-wide decision making under climate uncertainty.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SiC-Based 5-kV Universal Modular Soft-Switching Solid-State Transformer (M-S4T) for Medium-Voltage DC Microgrids and Distribution Grids

Medium-voltage DC (MVDC) grids are attractive for electric aircraft and ship power systems, battery energy storage system (BESS), fast charging electric vehicle (EV), etc. Such EV or BESS applications need isolated bidirectional MVDC to LVDC or LVAC converters. However, the existing Si-based solutions cannot fulfill the requirements of a high-efficiency and robust converter for MVDC grids. This paper presents a 5 kV SiC-based universal modular solid-state transformer (SST). This universal current-source SST can interface either a LVAC or LVDC grid with a MVDC grid in single-stage power conversion, while the conventional dual active bridge (DAB) converter needs an additional inverter. The proposed SST module using 3.3 kV SiC MOSFETs and diodes is bidirectional and can serve as a building block in series or parallel for higher-voltage higher-power systems. The topology of each module is based on the soft-switching solid-state transformer (S4T) with reduced conduction loss, which features reduced EMI through controlled dv/dt, and high efficiency with full-range ZVS for main devices and ZCS for auxiliary devices. Operation principle of the modular S4T (M-S4T), capacitor voltage balancing control between the cascaded modules, design of components including a medium-voltage (MV) medium-frequency transformer (MFT) to realize a 50 kVA 5 kV DC to 600 V DC or 480 V AC M-S4T are presented. Importantly, the MV MFT prototype achieves very low leakage inductance (0.13%) and 15 kV insulation with coaxial cables and nanocrystalline cores. Here, the proposed universal modular SST is compared against the DAB solution and verified with DC-DC and DC-AC simulation and 4 kV experimental results. Significantly, the MV experimental results of a modular DC transformer with each module at MVDC are rarely covered in the literature and reported for the first time.

14 SOLAR ENERGY↗

The Physics of Micro-Pinches

This project focused on using pulsed-power-driven techniques to study the coupling of high-energy-density (HED) magnetic fields to HED matter in the laboratory. Specifically, we studied a phenomenon known as "micro-pinching" to obtain HED conditions on a modest, university-scale pulsed-power driver: the 1-MA, 100-ns MAIZE linear transformer driver (LTD) facility at the University of Michigan. We used the "X-pinch" platform as a means of generating micro-pinch HED plasmas. An X-pinch is formed when two or more wires are crossed into the shape of an 'X' and a large electrical current is driven through the wires. This creates an intense electrical current density at the crossing point of the wires. Associated with this current density is an intense magnetic field and an intense magnetic field pressure. The magnetic field pressure compresses and heats the wire material into the HEDP regime. The use of an X-pinch platform ensures that the micro-pinch HED plasma will form in a well-controlled location, which helps with diagnostics alignment. This platform allowed us to explore the extreme plasma conditions and magnetic field pressures that can be generated with compact pulsed-power technology and intensely focused discharge currents. Understanding the limits of intensely focused discharge currents could have an enormous impact on HED science, especially when one considers the scaling of these platforms to the 30-MA Z facility at Sandia National Laboratories, where pressures well in excess of 1 Gbar could be achieved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ensuring Solution Uniqueness in Three-Phase Power System State Estimation

This paper is concerned with the issue of potential non-unique solutions in three-phase state estimation. Theory of observability analysis for positive sequence power system state estimation is based on certain assumptions that avoid possibility of multiple solutions. Also, it is shown that observability of a positive sequence network remains independent of the network parameters or the operating state. When extending single-phase observability analysis directly to the three-phase case, this paper considers the possibility of converging to multiple solutions, i.e. solution non-uniqueness, even for cases where state estimator successfully converges. The study illustrates via numerical examples the likelihood of converging to entirely different solutions for certain network parameters. It also examines how the operating state, particularly under unbalanced loading, leads to solution non-uniqueness. The paper then describes an alternative approach to ensure a unique solution in three-phase state estimation. This method aims to accurately and uniquely estimate the state of any unbalanced three-phase system, irrespective of load imbalance, network configuration, existence of synchronous generators or transformers.

Power System State Estimation, Three-Phase, Distri↗

Topological Machine Learning Methods for Power System Responses to Contingencies: Preprint

While deep learning tools, coupled with the emerging machinery of topological data analysis, are proven to deliver various performance gains in a broad range of applications, from image classification to biosurveillance to blockchain fraud detection, their utility in areas of high societal importance such as power system modeling and, particularly, resilience quantification in the energy sector yet remain untapped. To provide fast acting synthetic regulation and contingency reserve services to the grid while having minimal disruptions on customer quality of service, we propose a new topologybased system that depends on neural network architecture for impact metrics classification and prediction in power systems. This novel topology-based system allows one to evaluate the impact of three power system contingency types, namely, in conjunction with transmission lines, transformers, and transmission lines combined with transformers. We show that the proposed new neural network architecture equipped with local topological measures facilitates both more accurate classification of unserved load as well as the amount of unserved load. In addition, we are able to learn complex relationships between electrical properties and local topological measurements on the simulated response to contingencies for NREL-SIIP power system.

graph theory↗

Highly Efficient Regeneration Module for Carbon Capture Systems in NGCC Applications

The objective of this project is to design, fabricate, and test a highly efficient regeneration module capable of providing an ultra-lean absorption solution that is required for capturing CO 2 from dilute sources at 95% or better efficiency. By integrating this advanced regenerator module with SRI International’s Mixed Salt Process (MSP) absorption modules, SRI expects to demonstrate significant progress toward a reduction in cost of capture versus the DOE reference natural gas combined cycle (NGCC) plant with carbon capture. SRI designed, built, and tested an advanced stripper to enhance the performance of SRI’s MSP for CO 2 capture – a transformational ammonia-based solvent technology – for natural gas (NG) power sources. The testing of the advanced stripper for MSP was conducted at an SRI site using a simulated flue gas stream equivalent to about 10 kWe. The research work included modeling of the advanced stripper and integrating it with the MSP absorbers; studying the strategies for producing very highly alkaline lean solvent with minimized emissions; operating the stripper with advanced heat integration to improve process efficiencies; and collecting critically important data for a detailed techno-economic analysis (TEA). The project tasks were designed to address concerns relating to scale-up and integration of the technology to NG power plants—more specifically, to maximize the carbon capture efficiency achievable with MSP and identify pathways to achieve higher capture efficiencies and ultimately zero net carbon emissions. SRI teamed up with a process modeling company (OLI Systems), a process and chemical engineering company (Trimeric Corporation), and a cost-sharing commercial partner (Baker-Hughes – a leading multinational company that designs, manufactures, and services transformative energy technologies) to execute the project. The research findings will accelerate the MSP development and pave the way for the technology to reach the DOE’s goal, and ultimately commercialization of the MSP technology for low-cost CO 2 capture from NGCC flue gas and other dilute CO 2 sources.

03 NATURAL GAS↗

High-Power Oak Ridge Converter (ORC) for Extreme Fast Charging Applications

This project report presents a novel power converter system called Oak Ridge Converter (ORC), a patented technology developed by the Oak Ridge National Laboratory (ORNL) for XFC wireless EV charging systems. ORC integrates the grid interface converter (also known as the active front-end rectifier with power factor correction) with the high-frequency inverter stage, promoting size and cost-effective charging technology with reduced infrastructure costs. The integration of the front-end rectifier with the high-frequency inverter truly eliminates one power conversion stage and achieves more than 33% size, weight, volume, and cost reduction on the wireless charging systems. Furthermore, ORC eliminates the primary side direct current (DC) bus bulk capacitors that are usually aluminum electrolytic capacitors and replaces them with very small, cost-effective, highly reliable, and high-temperature operation-capable alternate current (AC) film capacitors. ORC is also applicable to both single-phase and poly-phase couplers. When used with polyphase couplers, ORC further improves the power density of the overall system with higher power density power electronics. Moreover, ORC is inherently bidirectional and allows the system to provide power back to the grid for grid ancillary or grid support services. The ORC, based on a patented ORNL technology, is an excellent approach to resolving the high-power charging problems as described above, which directly converts the 60 hertz (Hz) line frequency into high frequency (i.e., 85 kilohertz (kHz)) to use with a high-frequency isolation transformer or wireless charging coils while eliminating the primary side number of power conversion stages from two to one. The result of the project is a prototype and reference design for a high-power wireless charging system—including power electronics, magnetics, and thermal—serving as a baseline for product development. The proposed system results are demonstrated for 270 kW of output power, with the system's overall efficiency of 92% from the AC grid, achieving less than 3% current total harmonic distortion (THD) and around 0.99 power factor (PF).

33 ADVANCED PROPULSION SYSTEMS↗

EMP-Resilient Electric Grid Transformer Analysis

The response of a high - voltage (HV) transformer to fast rise time voltages, such as that from a electromagnetic pulse (EMP) can result in interruption of power distribution and possibly system failure. To help identify these potential occurrences, it is necessary to develop a transformer model that not only captures the input/output response of the transformer but also the internal behavior. The model constructed should cover the frequency band of interest while capturing the internal physical and electrical characteristics. This broad-band, high-fidelity model would enable the prediction of unwanted effects through simulation. A proposed modeling scheme for a HV transformer is described in Part 1 of this report. Part 2 of this report details assessments of internal voltage and electrical field holdoff testing of transformer insulation dielectric breakdown, including comparison of low frequency (DC/60 Hz) holdoff to rise times characteristic of lightning (1 s) and EMP E1 transients (10 - 30 ns). This initial project is a path toward establishing electrical grid transformer failure criteria for EMP voltage transients. We developed modeling methods and measured breakdown electrical field statistical distributions for direct current, 60 Hz, lightning and EMP characteristic voltage rise times. Methods of nanosecond-scale capacitive discharge unit high voltage source development, suggestions for derating of 60 Hz insulation maximum electrical fields for EMP nanosecond pulse voltage withstand rating, and potential methods for increasing transformer resilience to such fast rise time pulses are described.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BEEAM (Building Electrical Efficiency Analysis Model) [SWR-20-107]

Modern high-performance buildings exhibit an increasing number of building loads that use direct current (DC) electricity internally, rather than alternating current (AC), due to the advent of low-cost computing and advanced power electronics. Powering DC devices from the AC grid requires AC/DC power conversion, which introduces energy losses and reduces efficiency. As DC loads proliferate, the cumulative wasted energy associated with hundreds of millions of AC/DC converters has become one of the broadest energy savings opportunities in buildings. DC power distribution systems have been proposed as an elegant and transformative solution to the problem of DC devices. In a DC distribution system, the building's wires carry DC electricity, rather than AC; and a few centralized, highly efficient AC/DC converters replace the many smaller, less efficient converters that serve individual DC loads. Unfortunately, the trade-offs associated with DC distribution systems are not well understood. Reported energy savings associated with DC power distribution differ widely and have not been well validated. The Building Electrical Efficiency Analysis Model (BEEAM) is a Modelica library that simulates the efficiency of building electrical distribution systems using harmonic power flow. BEEAM can model a wide variety of building distribution topologies, including three-phase AC, single-phase AC, unipolar DC, bipolar DC, and hybrid networks under both balanced and unbalanced load conditions. BEEAM accurately models power electronic converter losses, provides granular estimates of losses throughout the distribution system, and properly models efficiency at part load conditions. Users can package BEEAM within a functional mockup unit (FMU), enabling co-simulation with other modeling platform, such as EnergyPlus. In summary, BEEAM provides a tool suite for fair and accurate comparison of the efficiency of building electrical distribution systems, including AC, DC, and hybrid systems.

Frank, Stephen↗

High power targets: Challenges of next-generation high-intensity neutrino beams

High power target systems are crucial elements in enabling future neutrino and other rare particle beams. These systems transform intense source of protons into secondary particles of interest to enable new scientific discoveries. As primary beam intensities increase in next-generation multi-megawatt accelerator facilities, high power target systems face key challenges. Thermal shock and radiation damage effects in beam-intercepting devices were identified as the leading cross-cutting challenges of high-power target facilities. Target materials R&D to address these challenges are therefore essential to enable and ensure reliable operation of future accelerator target facilities. This paper provides an overview of the R&D activities underway to help support high power target systems development for next-generation multi-MW facilities.

43 PARTICLE ACCELERATORS↗