Power System Waveform Datasets for Machine Learning

The desire for increased visibility across the electricity grid will necessarily increase the deployment of sensing and measurement devices and associated data management needs to unprecedented levels. For the existing sensing and measurement infrastructure, there remains a great amount of “value” yet to be extracted through advanced data management and analytics. Availability of more data will not, by itself, lead to changes in grid visibility, security, and resiliency. To create the predictive and prescriptive environment required to enable new markets and transactions for customer revenue and a reliable grid, the data must be collected, organized, evaluated, and analyzed using sophisticated algorithms to provide actionable information allowing operators and customers to reliably manage an increasingly complex grid. Progress in artificial intelligence (AI) has been largely driven by large, publicly available datasets that can be used to train AI algorithms such as MNIST, a database of handwritten images of digits, and ImageNet, an image database of everyday objects. These types of publicly available databases of real-world training datasets have been largely credited for advancement of image processing, computer vision, and deep learning algorithms that these use cases deploy. However, in the power systems industry to date, there are few databases with proper event labeling, and data access to a publicly available collection of power system event waveforms that will allow users to interact with grid signature data. Publicly available datasets of power system event waveforms, such as the DOE/EPRI dataset, often lack critical metadata or contain limited examples of each event type, and data formats vary widely across these datasets.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Results of the telstar system communications tests

The results of the communications tests on the Telstar satellite system which have been conducted at the Andover earth station are presented. These tests have included successful transmissions of telephone, television, and data signals. In addition, measurements of received carrier power, noise, transmission characteristics, linearity, data system errors, absolute delay, and Doppler shift have been made. The results are in good agreement with the expected performance.

GROUND STATION↗

Fast Quasi-Static Time-Series Simulation for Accurate PV Inverter Semiconductor Fatigue Analysis with a Long-Term Solar Profile

Power system simulations with long-term data typically have large time steps varying from one second to a few minutes. However, for PV inverter semiconductors, the minimum thermal stress cycle occurs over the fundamental grid frequency (50 or 60 Hz). This requires the time step of the fatigue simulation to be around 100 µs. This small time step requires long computation times to process yearly power production profiles. This paper proposes a fast fatigue simulation for inverter semiconductors using the quasi-static time series (QSTS) simulation concept. The proposed simulation calculates the steady state of the semiconductor junction temperature by using a Fast Fourier Transform (FFT). The small thermal cycling during a switching period and even over the fundamental waveform is disregarded to further accelerate the simulation speed. The resulting time step of the fatigue simulation is 15 minutes, which is consistent with the solar dataset. The error of the proposed simulation is 0.16% compared to the fatigue simulation results using the complete thermal stress profile. A PV inverter that responds to a Transactive Energy System (TES) is simulated to demonstrate the use of the proposed fatigue simulation. The proposed simulation has the potential to co-simulate with system level simulation tools that also adopt the QSTS concept.

Liu, Yunting↗

Novel Temperature Sensors and Wireless Telemetry for Active Condition Monitoring of Advanced Gas Turbines

The objective of the program is to develop and engine test hardware and software technologies that will enable active condition monitoring to be implemented on hot gas path turbine blades in large industrial gas turbines. The specific objectives are (1) to fabricate and install Smart Turbine Blades with thermally sprayed sensors and high temperature wireless telemetry systems in a gas turbine engine, (2) to integrate the component engine test data with remaining useful life (RUL) models and develop an approach for networking the component RUL data with Siemens' Power Diagnostics® engine monitoring system. These significant advances carried out in Phase 1 in temperature wide bandgap telemetry, along with new induced power driver and receiver geometry combined with an innovative approach to transmit digital data wirelessly will enable the opportunity to proceed with more technical innovation. The Phase 2 program focused on validation testing of sensor-wireless telemetry package in spin rig and advanced operation-based assessment (OBA) model utilizing artificial intelligence. Significant efforts were dedicated on the download of the technology onto components to be tested an actual gas turbine engine for full realization of active condition monitoring for Smart Turbine Blades.

03 NATURAL GAS↗

NASA Hitchhiker Program Customer Payload Requirements (CPR)

The mission objective is to demonstrate each of the three types of technology intended for future small-satellite communications system design. Each experiment in the overall package is designed to exercise a different technology objective that may be found in the overall satellite communications and telemetry system design. The data communications through TORSS portion is designed to demonstrate that low-power communications systems with non-gimbaled antenna systems can transport significant quantities of data through TDRSS to the ground based on only transmitting through a TDRS when the experiment is near the TDRS subsatellite point. The remaining time. the payload communications system is not active. The demand access experiment is to demonstrate that the request for a demand access service can be transmitted through TDRS and received and decoded at the ground station. In this mode, the TDRS does not track the experiment but signal processing components at the White Sands Complex are used to detect and track the transmitted request. The laser communications experiment is designed to demonstrate passive transmission of telemetry data from the experiment. This mode uses a ground-based laser source to illuminate the experiment and modulate the beam with the data. Ground-based reception recovers the data from the reflected beam back to the ground station.

Horan, Stephen↗

Powering the Blue Economy Foundational Research & Development Topics Reliability for Marine Energy Power Systems

Ocean observing platforms are deployed across the world’s oceans to collect meteorological and oceanographic data. Current technology makes use of solar panels and battery banks to provide power to these platforms, which can be challenging at high latitudes due to lack of solar insolation and cold temperatures. Marine renewable energy (MRE) generation offers a potential improvement in consistent power generation throughout the year for this use on ocean observation buoys. This report analyzes existing reliability of high latitude coastal weather buoys and tsunami detection buoys to determine performance standards that MRE generation sources must meet to become viable power sources for these remote systems. Using measurements recorded from the U.S. National Data Buoy Center’s coastal weather buoys and tsunami detection buoys, the analysis calculated the historic data availability – or the percentage of time a measurement is recorded – to evaluate the reliability of ocean observation buoys. The results show that coastal weather buoys operate at 74% data availability and the tsunami detection systems operate at an average 72% data availability. The results describe the total reliability of the system, including many different types of failures not associated with the power system such as mooring failures or equipment failures caused by extreme weather. Power system outages may only account for a small portion of the system failures. Reliability is an important design criterion for the power system of ocean observation platforms. Future power systems that would be designed for these buoys, such as an MRE generator, need to have a minimum reliability of 72% and 74% to meet the overall performance of the weather buoys and tsunami buoys, respectively. However, power system reliability likely needs to be much higher than overall system reliability, so that power system outages do not negatively impact the overall performance of the buoy.

42 ENGINEERING↗

Anomaly Detection, Localization and Classification using Drifting Synchrophasor Data Streams

With ongoing automation and digitization of the electric power system, several Phasor Measurement Units(PMUs) have been deployed for monitoring and control. PMU data can have multiple anomalies, and many of the researchers in the past have concentrated on training machine/deep learning algorithms offline for anomaly detection over PMU data (i.e., not in real time). These machine/deep learning algorithms, when trained offline on a sample rather than a population of the dataset, fail to consider the dynamic behavior of the power grid in real-time, resulting in low accuracy. Considering the dynamic behavior of the power grid (e.g., change in load, generation, distributed energy resources (DERs) switching, network, controls), the definition of data anomalies varies in time and requires online training. A fundamental challenge is to enable online (i.e., real-time) training of machine/deep learning algorithms for anomaly detection over streaming PMU data. While machine/deep learning is often desirable to manage data streams, training a deep learning algorithm over streaming PMU data is nontrivial due to changes in data statistics caused by dynamic streaming data. This paper proposes PMUNET: a novel device-level deep learning-based data-driven approach for anomaly detection, localization, and classification over streaming PMU data, using online learning and multivariate data-drift detection algorithm .Two variants of PMUNET, Dynamic data Change Driven Learning (DCDL) and Continuity Driven Learning (CDL), are proposed and compared. DCDL aims to train the deep learning algorithm whenever the definition of anomaly changes due to the power grid dynamics. On the other hand, CDL continuously trains the deep learning algorithm over the PMU data-stream. The experimental results verify that DCDL outperforms CDL and other efficient anomaly detection methods over multiple events such as faults and load/ generator/capacitor/DERs variations/switching for IEEE 14 and 39 Bus test system as well as real PMU industrial data. The result verifies that DCDL variant of PMUNET improves over existing approach with a gain of 2% - 10% in terms of accuracy, false-positive rate, and false-negative rate.

adversarial deep learning↗

High-Fidelity Solar Irradiance Data: Simple Access to State-of-the-Art Information Accelerates Southeast Asia's Clean Energy Economic Transformation

High quality, robust, and reliable renewable energy resource data is foundational to climate-smart decision making, evidence-based policy planning, and clean energy investment mobilization. USAID and NREL, through the Advanced Energy Partnership for Asia, are expanding access to this critical resource data by providing free, high-fidelity solar resource data for Southeast Asia through the RE Data Explorer platform. This brief highlights several ways the Southeast Asia solar resource data has been used for power system planning and project development in the region.

Advanced Energy Partnership for Asia↗

Programmable, automated transistor test system

A programmable, automated transistor test system was built to supply experimental data on new and advanced power semiconductors. The data will be used for analytical models and by engineers in designing space and aircraft electric power systems. A pulsed power technique was used at low duty cycles in a nondestructive test to examine the dynamic switching characteristic curves of power transistors in the 500 to 1000 V, 10 to 100 A range. Data collection, manipulation, storage, and output are operator interactive but are guided and controlled by the system software.

Truong, L. V.↗

Data for "Implications of Zoning Ordinances for Rural Utility-Scale Solar Deployment and Power System Decarbonization in the Great Lakes Region".

This dataset includes the Energy Zoning Database and geographic shapefiles used to identify suitable rural areas for utility-scale solar development. Additionally, it contains the input data required for the capacity expansion model, including information on existing electric generators and their associated costs, solar resource potential, and transmission infrastructure data. These datasets collectively support the analysis presented in the paper, ensuring a comprehensive assessment of zoning regulations, land suitability, and the economic and technical feasibility of solar deployment in rural areas.

Owusu-Obeng, Papa Yaw (ORCID:0000000334385183)↗

Flight experience of solar mesosphere explorer's power system over high temperatures ranges

The performance of the power system on the Solar Mesosphere Explorer (SME) satellite for the life of the mission and the techniques used to ensure power system health are summarized. Early in the mission high cell imbalances in one of the batteries resulted in a loading scheme which attempted to minimize the cell imbalances without causing an undervoltage condition. A short term model of the power system allowed planners to predict depth of discharge using the latest available data. Due to expected orbital shifts the solar arrays experience extended periods of no eclipse. This has required special conditioning schemes to keep the batteries healthy when the eclipses return. Analysis of the SME data indicates long term health of the SME power system as long as the conditioning scheme is continued.

Faber, Jack↗

Development of a NASA 6-U Satellite

NASA/Wallops Flight Facility has focused on the development of new technologies for the advancement of 6 Unit (6U) small satellites. From the design of the structure and instrument support hardware to improvements in the deployer, NASA is concentrating on maximizing the potential of small satellites for the benefit of science. The telemetry system provides much higher data rates than typical I U UHF system. 6U provides up to several hundred kilobits per second and utilizes the existing NASA Ground Network for data reception. The guidance, navigation and control system keeps the satellite pointed within plus or minus 10 degrees of the sun and has knowledge of the sun vector within 1 degree. The 6U power design increased the options for different voltages and power switching capabilities and is capable of supporting instruments with higher power requirements. The Command & Data Handling (C&DH) system includes a low-power 520 MHz flight processor which provides more processing capability than existing I U processor technologies. These optimized technologies will offer the science community a greater opportunity for flying more sophisticated and complex instruments.

Thompson, Linda D.↗

Integrated Framework of Multisource Data Fusion for Outage Location in Looped Distribution Systems

Accurate outage location is essential for expediting post-outage power restoration, minimizing outage duration, and enhancing the resilience of distribution networks. With the advent of advanced metering infrastructure, data-driven outage location methods have significantly advanced beyond traditional approaches that rely on manual inspections. However, existing methods still face critical challenges, like reliance on single-source data, limited ability to handle partially observable systems or difficulties with loop networks. To the best of our knowledge, no single approach has comprehensively addressed all of these challenges at once. To this end, this paper proposes a comprehensive multisource data fusion framework for outage locations via probabilistic graph networks. The framework consists of three key phases. First, a novel method for reconstituting distribution networks with loops is developed, transforming looped networks into multiple radial subnetworks that retain all outage causalities of the original network. Second, Bayesian network (BN) models are established for each subnetwork, integrating multiple data sources and network structures. Finally, a joint Gibbs sampling mechanism, featuring forward and backward information flow, is designed to merge data from separate BN models and maximize the utilization of limited evidence, ensuring accurate outage location identification. In conclusion, the framework was validated on two modified public test systems, and comparative studies confirmed its effectiveness.

24 POWER TRANSMISSION AND DISTRIBUTION↗

End-to-end quality measure for transmission of compressed imagery over a noisy coded channel

For the transmission of imagery at high data rates over large distances with limited power and system gain, it is usually necessary to compress the data before transmitting it over a noisy channel that uses channel coding to reduce the effect of noise introduced errors. Both compression and channel noise introduce distortion into the imagery. In order to design a communication link that provides adequate quality of received images, it is necessary first to define some suitable distortion measure that accounts for both these kinds of distortion and then to perform various tradeoffs to arrive at system parameter values that will provide a sufficiently low level of received image distortion. The overall mean square error is used as the distortion measure and a description of how to perform these tradeoffs are included.

Korwar, V. N.↗

Report of the Power Sub systems Panel

Problems in spacecraft power system design, testing, integration, and operation are identified and solutions are defined. The specific technology development problems discussed include substorm and plasma design data, modeling of the power subsystem and components, power system monitoring and degraded system management, rotary joints for transmission of power and signals, nickel cadmium battery manufacturing and application, on-array power management, high voltage technology, and solar arrays.

Source record↗