Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power distribution network”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

DSP Implementation of a Novel Recurrent Neural Network Controller into a TI Solar Microinverter

Single-phase grid-tied inverters are widely used to integrate small-scale renewable energy sources and distributed generations to the utility grid. A novel Recurrent Neural Network (RNN) current controller is introduced to solve the resonant problem associated with LCL based inverters. The well-trained RNN controller was validated through a Texas Instruments (TI) LCL filter based solar microinverter kit that contains a C2000 TI microcontroller. The inverter closed current loop test without the grid connection was conducted in a laboratory setup to verify the RNN contoller functionality. The laboratory waveform results verified that the RNN current controller produced the strong tracking of the measured inverter AC current to its reference value even at a low sampling frequency of 5KHz. The proposed RNN current controller also proved to perform better than the built-in three-pole-three-zero (3P3Z) current controller provided by TI and produce lower values of Total Harmonic Distortion (THD).

digital signal processor↗

Development of an Adaptive Droop Control Method for Interconnected Lunar DC Microgrids Using Power Hardware-in-the-Loop

NASA’s Artemis Program outlines the need for a habitat capable of sustaining human life as well as mining and producing raw materials on the lunar surface. This mission is viewed as a means towards deeper space exploration, with plans for reaching Mars and beyond. Human presence on the moon is not possible without the ability to generate and distribute energy, namely electricity, through a network of energy sources, loads, and power converters called a microgrid. Multiple microgrids can be deployed on the moon based on location and need. Separate microgrids will require interconnection to increase resiliency and reliability given the mission’s high criticality. A method for adaptive control over power converters connecting two dc microgrids is proposed. A simulation is modeled after the lunar power system with two approaches to power converter droop control, allowing for a more flexible and adaptive microgrid architecture. Further experiments are conducted using the control methods in a power hardware-in-the-loop test environment to study the performance of hardware converter control used in this application.

dc microgrid↗

Networked Microgrid Topology Reconfiguration to Promote Fairness in Proactive Load Shedding

Increasing occurrences of natural disasters and grid emergency events consistently challenge the safe and reliable operations of power systems. During such emergency situations, system operators may proactively shed load to mitigate risks. However, uncoordinated implementation of load shedding may disrupt electricity supply and even lead to cascading failures. Meanwhile, it is crucial to address potential biases affecting different customers when executing load shedding. This paper addresses the dynamic topology reconfiguration problem for networked microgrids with distributed energy resources under emergency conditions. Specifically, we propose a novel rolling-horizon optimization model that integrates fairness-aware constraints into the networked microgrid topology reconfiguration. Unlike existing approaches that focus solely on efficiency or apply fairness considerations in static settings, our method explicitly incorporates temporal fairness constraints to restrict repeated or excessive load curtailment for load blocks. Moreover, the fairness-aware constraints are specifically developed for the context of dynamic networked microgrid topology reconfiguration, and are designed to be convex or amenable to linear reformulations, which offers a more tractable alternative to traditional models with non-convex formulations. Numerical studies on a modified IEEE 13-bus system and a larger-sized SMART-DS networked microgrid system demonstrate the performance of the proposed algorithm towards more fairness-aware networked microgrid topology reconfiguration decision-making.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Threat Hunt Guide for BESS Environments

The rapid digitalization of the electric grid - driven by the integration of inverter-based resources (IBRs), battery energy storage systems (BESS), and advanced grid control platforms - has significantly enhanced grid efficiency, visibility, and flexibility. However, this evolution also introduces new cybersecurity risks, particularly through supply chain dependencies and operational blind spots at the grid edge. To address these challenges, Idaho National Laboratory (INL), through the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) Rapid Risk initiative, conducted a series of rapid risk assessment engagements with energy organizations across the United States. Drawing on lessons learned from these engagements, INL developed the following threat hunting guide for asset owners and operators (AOOs) to enhance their cybersecurity visibility within BESS and IBR systems. The guide demonstrates how to use passive network monitoring to baseline device behavior, detect adversarial activity, and investigate anomalies without disrupting operations. By implementing these practices, energy sector stakeholders can improve coordination between cybersecurity and operations teams and strengthen the resilience of distributed energy resources (DERs) within the modern power grid. Prior to implementing any network monitoring, packet capture, or threat hunting activity described in this guide, AOOs are strongly advised to review applicable governance frameworks, legal requirements, and organizational policies. This guide is intended for informational and educational purposes only. It does not replace compliance with any federal, state, or local cybersecurity mandates or industry standards. Implementation of described configurations, technologies, or analytic workflows is performed at the discretion and responsibility of the asset owner and operator.

25 - ENERGY STORAGE↗

Networked Microgrid Optimal Design and Operations Tool: Regulatory and Business Environment Study

Microgrids aim to increase the resilience of the electric supply to the loads within the microgrid through the ability to disconnect from the distribution utility in the event of a power outage and by supplying power to the microgrid loads from a combination of multiple power generation assets and storage systems. Microgrids can also improve reliability at the distribution level by reducing the load on the system under stress conditions. Networking two or more microgrids has the potential to increase reliability and resilience at a reduced cost by taking advantage of economies of scale and increasing the diversity of the generation assets and loads. This report is part of a collaborative effort among several U.S. Department of Energy national laboratories to develop a networked microgrid (NMG) Optimal Design and Operations (OD&O) tool. This tool addresses the goal defined in the Grid Modernization Multi-Year Program Plan to develop a suite of tools that addresses functional requirements for system optimal design and the operations of NMGs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributionally Robust Decentralized Volt-Var Control With Network Reconfiguration

Here, this paper presents a decentralized volt-var optimization (VVO) and network reconfiguration strategy to address the challenges arising from the growing integration of distributed energy resources, particularly photovoltaic (PV) generation units, in active distribution networks. To reconcile control measures with different time resolutions and empower local control centers to handle intermittency locally, the proposed approach leverages a two-stage distributionally robust optimization; decisions on slow-responding control measures and set points that link neighboring subnetworks are made in advance while considering all plausible distributions of uncertain PV outputs. We present a decomposition algorithm with an acceleration scheme for solving the proposed model. Numerical experiments on the IEEE 123 bus distribution system are given to demonstrate its outstanding out-of-sample performance and computational efficiency, which suggests that the proposed method can effectively localize uncertainty via risk-informed proactive timely decisions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Approximating Trajectory Constraints With Machine Learning – Microgrid Islanding With Frequency Constraints

Here, we introduce deep earning aided constraint encoding to tackle the frequency-constraint microgrid scheduling problem. The nonlinear function between system operating condition and frequency nadir is approximated by using a neural network, which admits an exact mixed-integer formulation (MIP). This formulation is then integrated with the scheduling problem to encode the frequency constraint. With the stronger representation power of the neural network, the resulting commands can ensure adequate frequency response in a realistic setting in addition to islanding success. The proposed method is validated on a modified 33-node system. Successful islanding with a secure response is simulated under the scheduled commands using a detailed three-phase model in Simulink. The advantages of our model are particularly remarkable when the inertia emulation functions from wind turbine generators are considered.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bus Clustering for Distribution Grid Topology Identification

Recovering the distribution grid topology is essential to perform several distribution system operator functions. Many algorithms that address the topology recovery problem have already been proposed in the literature. Most are based on a priori information regarding which buses are fed by which substation; however, this information might not be available because frequent grid reconfigurations change the distribution grid portion connected to each substation. This paper addresses the problem of assigning every substation the set of buses that it is feeding, given field data. First, the aforementioned task is cast as a nonconvex optimization problem. Second, a relaxed version of the optimization problem is solved via the alternating direction method of multipliers. Finally, the performance of our approach is validated through numerical simulations of realistic scenarios using a standard IEEE benchmark feeder.

bus clustering↗

Power System Event Identification Based on Deep Neural Network With Information Loading

Online power system event identification and classification are crucial to enhancing the reliability of transmission systems. In this study, we develop a deep neural network (DNN) based approach to identify and classify power system events by leveraging real-world measurements from hundreds of phasor measurement units (PMUs) and labels from thousands of events. Two innovative designs are embedded into the baseline model built on convolutional neural networks (CNNs) to improve the event classification accuracy. First, we propose a graph signal processing based PMU sorting algorithm to improve the learning efficiency of CNNs. Second, we deploy information loading based regularization to strike the right balance between memorization and generalization for the DNN. Numerical results based on real-world dataset from the Eastern Interconnection of the U.S power transmission grid show that the combination of PMU based sorting and the information loading based regularization techniques help the proposed DNN approach achieve highly accurate event identification and classification results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power System Event Identification with Transfer Learning Using Large-scale Real-world Synchrophasor Data in the United States

The lack of sufficient labeled events and long training time limit the applicability of deep neural network-based power system event identification using synchrophasor data. In this paper, we propose to leverage transfer learning technique to boost the reliability and reduce the required training time of neural classifier for power system event identification. We use the weights of a neural classifier trained on one transmission system as the initial parameters of another neural classifier for a different transmission system. Numerical tests with real-world synchrophasor data from the Eastern and Western Interconnections of the United States show that the proposed transfer learning approach is very effective in not only improving the training reliability but also reducing the training time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Period Active Distribution Network Planning Using Multi-Stage Stochastic Programming and Nested Decomposition by SDDIP

This paper presents a multi-period active distribution network planning (ADNP) with distributed generation (DG). The objective of the proposed ADNP is to minimize the total planning cost, subject to both investment and operation constraints. The paper proposes a multi-stage stochastic optimization model to address DG uncertainties over several periods, in which the decisions are made sequentially by only using the present-stage information. A nested decomposition method is proposed which applies the stochastic dual dynamic integer programming (SDDIP) method to address computational intractabilities of the proposed ADNP approach. The presented numerical results and discussions on a 33-bus distribution system and a large-scale 906-bus system verify the effectiveness of the proposed ADNP method and its solution method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Retracted Article: Distributed energy management for networked microgrids in a three-phase unbalanced distribution network

Owing to increased penetration of three-phase and single-phase microgrids, distributed energy resources (DERs), and responsive loads, the maintenance of a three-phase balance by distribution networks is a significant challenge. Existing literature on distributed energy management for networked microgrids generally neglects the distribution network or employs a simplified phase balanced distribution network; thus, these evaluations are not applicable. Further, the underlying mutual coupling between the different phases of distribution feeders results in a more challenging situation. Here, to solve this issue, this study sought to propose distributed energy management based on a three-phase unbalanced distribution network. Various three-phase or single-phase microgrids, utility-owned DERs, and responsive loads were coordinated through iteratively adjusted price signals. Based on the price signals received, the microgrid controllers (MCs) and distribution management system (DMS) updated the schedules of the DERs and responsive loads under their jurisdiction separately. The price signals were then updated according to the generation-load mismatch at each node and distributed to the corresponding MCs and DMS for the next iteration. The iteration continued until a sufficiently small generation-load mismatch was achieved at all nodes, that is, a balanced generation and load at all nodes under the agreed price signals. Considering a three-phase unbalanced distribution network, the price signals were determined per phase per node. Overall, the proposed distributed energy management coordinates microgrids, utility-owned DERs, responsive loads with guaranteed network constraints, and preserves the privacy of microgrid customers. This distributed energy management method was further demonstrated through various case studies on a three-phase networked microgrid test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Small-Signal Stability Conditions for Inverter-Based Unbalanced Microgrids

The proliferation of inverter-based generation and advanced sensing, controls, and communication infrastructure have facilitated accelerated deployment of microgrids. A coordinated network of microgrids can maintain reliable power delivery to critical facilities during extreme events. Low-inertia offered by the power-electronics–interfaced energy resources, however, can present significant challenges to ensuring stable operation of the microgrids. In this work, distributed small-signal stability conditions for inverter-based microgrids are developed that involve the droop-controller parameters and the network parameters (e.g. line impedances, loads). The distributed closed-form parametric stability conditions derived in this paper can be verified in a computationally efficient manner, facilitating reliable design and operations of networks of microgrids. Dynamic phasor models have been used to capture the effects of electromagnetic transients. Furthermore, numerical results are presented, along with PSCAD simulations, to validate the analytical stability conditions. Effects of design choices, such as the conductor types, and inverter sizes, on the small-signal stability of inverter-based microgrids are investigated to derive useful engineering insights.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Description of a MIL-STD-1553B Data Bus Ada Driver for the LeRC EPS Testbed

This document describes the software designed to provide communication between control computers in the NASA Lewis Research Center Electrical Power System Testbed using MIL-STD-1553B. The software drivers are coded in the Ada programming language and were developed on a MSDOS-based computer workstation. The Electrical Power System (EPS) Testbed is a reduced-scale prototype space station electrical power system. The power system manages and distributes electrical power from the sources (batteries or photovoltaic arrays) to the end-user loads. The electrical system primary operates at 120 volts DC, and the secondary system operates at 28 volts DC. The devices which direct the flow of electrical power are controlled by a network of six control computers. Data and control messages are passed between the computers using the MIL-STD-1553B network. One of the computers, the Power Management Controller (PMC), controls the primary power distribution and another, the Load Management Controller (LMC), controls the secondary power distribution. Each of these computers communicates with two other computers which act as subsidiary controllers. These subsidiary controllers are, in turn, connected to the devices which directly control the flow of electrical power.

Mackin, Michael A.↗

Voltage Estimation in Low-Voltage Distribution Grids with Distributed Energy Resources

Present distribution grids generally have limited sensing capabilities and are therefore characterized by low observability. Improved observability is a prerequisite for increasing the hosting capacity of distributed energy resources such as solar photovoltaics (PV) in distribution grids. In this context, this paper presents learning-aided low-voltage estimation using untapped but readily available and widely distributed sensors from cable television (CATV) networks. The cable broadband sensors offer timely local voltage magnitude sensing with 5-minute resolution and can provide an order of magnitude more data on the time-varying state of a secondary distribution system than currently deployed utility sensors. The proposed solution incorporates voltage readings from neighboring CATV sensors, taking into account spatio-temporal aspects of the observations, and estimates single-phase voltage magnitudes at all non-monitored low-voltage buses using random forests. The effectiveness of the proposed approach was demonstrated using a multi-phase 1572-bus feeder from the SMART-DS data set for two case studies passive distribution feeder (without PV) and active distribution feeder (with PV). The analysis was conducted on simulated data, and the results show voltage estimates with a high degree of accuracy, even at extremely low percentages of observable nodes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilient Communication Scheme for Distributed Decision of Interconnecting Networks of Microgrids

Networking of microgrids can provide the operational flexibility needed for the increasing number of DERs deployed at the distribution level and supporting end-use demand when there is loss of the bulk power system. But, networked microgrids are vulnerable to cyber-physical attacks and faults due to the complex interconnections. As such, it is necessary To design resilient control systems to support the operations of networked microgrids in responses to cyber-physical attacks and faults. This paper introduces a resilient communication scheme for interconnecting multiple microgrids to support critical demand, in which the interconnection decision can be made distributedly by each microgrid controller even in the presence of cyberattacks to some communication links or microgrid controllers. This scheme blends a randomized peer-to-peer communication network for exchanging information among controllers and resilient consensus algorithms for achieving reliable interconnection agreement. The network of 6 microgrids divided from a modified 123-node test distribution feeder is used to demonstrate the effectiveness of the proposed resilient communication scheme.

Vu, Thanh Long↗

Advanced Metering Infrastructure for Distribution Planning and Operation: Closing the Loop on Grid-Edge Visibility

In the recent history of electric utilities, the potential to have visibility of the grid edge is gaining significance for the reliable planning and operation of a clean energy smart grid. Before the recent large-scale customer adoption of distributed energy resources (DERs), distribution networks were planned with a simpler fit-and-forget philosophy. The importance of customer-sited DERs to achieve climate change goals marks a major shift for utility operations. Changes to traditional fit-and-forget planning paradigms require better availability of grid-edge data. Smart metering is an enterprise-wide tool that is enabling visibility when and where it has been most needed. As of 2020, the rollout of smart metering, or advanced metering infrastructure (AMI), had reached more than 100 million meters in the United States, and nearly half of all electricity customers are now equipped with a smart meter (Figure 1). Smart meters are quickly becoming a ubiquitous data capture feature of smart grids. AMI enables utilities to record and measure electricity usage and power-flow metrics at a minimum of hourly intervals and at least once a day. At a minimum, AMI enables interval metering, automatic meter reading enabling accurate and time-interval billing, and the ability to provide feedback on customer energy consumption.

advanced metering infrastructure↗