Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

On the Nature of the Arctic’s Positive Lapse-rate Feedback: Cause or Symptom of Arctic Amplification

Radiative energy fluxes exiting the atmosphere towards the surface and to space are sensitive to the vertical structure of temperature. Under anthropogenic forcing, this sensitivity gives rise to the lapse-rate feedback. Shown to be negative in the tropics and positive in the Arctic, studies argue that the lapse-rate feedback is the primary cause of Arctic Amplification. While mechanistically the negative tropical lapse-rate feedback is understood, the mechanics of the positive Arctic lapse-rate feedback are less clear. Previous arguments state that the Arctic’s stable stratification is the origin of its positive lapse-rate feedback. We present results using CMIP5 and CMIP6 model output that arguing that the magnitude, spatial variability, seasonality, and inter-model spread in the Arctic lapse-rate feedback is controlled by surface properties and atmosphere-ocean-sea ice energy exchanges, not the degree of stable stratification. We argue that the Arctic’s positive lapse-rate feedback is a seasonal and regional phenomenon that manifests from local surface characteristics and surface albedo, ice insulation, and thermal inertia feedbacks that cause surface warming to outpace atmospheric warming in sea ice-retreat regions. We view the Arctic’s positive lapse-rate feedback as a symptom rather than the primary cause of Arctic Amplification.

Patrick Charles Taylor↗

On the Nature of the Arctic’s Positive Lapse Rate Feedback Cause or Symptom of Arctic Amplification

Radiative energy fluxes exiting the atmosphere towards the surface and to space are sensitive to the vertical structure of temperature. Under anthropogenic forcing, this sensitivity gives rise to the lapse-rate feedback. Shown to be negative in the tropics and positive in the Arctic, studies argue that the lapse-rate feedback is the primary cause of Arctic Amplification. While mechanistically the negative tropical lapse-rate feedback is understood, the mechanics of the positive Arctic lapse-rate feedback are less clear. Previous arguments state that the Arctic’s stable stratification is the origin of its positive lapse-rate feedback. We present results using CMIP5 and CMIP6 model output that arguing that the magnitude, spatial variability, seasonality, and inter-model spread in the Arctic lapse-rate feedback is controlled by surface properties and atmosphere-ocean-sea ice energy exchanges, not the degree of stable stratification. We argue that the Arctic’s positive lapse-rate feedback is a seasonal and regional phenomenon that manifests from local surface characteristics and surface albedo, ice insulation, and thermal inertia feedbacks that cause surface warming to outpace atmospheric warming in sea ice-retreat regions. We view the Arctic’s positive lapse-rate feedback as a symptom rather than the primary cause of Arctic Amplification.

Patrick C Taylor↗

Highly accurate positions of asteroids using astrometry

Astrometry is the precise measurement of positions in the sky of stars and other celestial bodies. In this paper, measurements of asteroids and outer planet natural satellites are discussed. We used the Astro Mechanics, Ritchey-Chrétien reflecting, 0.6m telescope at Table Mountain Observatory (TMO) located in Wrightwood, CA. Equipped with a 4k CCD camera (the ProLine4096x4096 imaging array with 9μm pixels), using 180 second exposures, we imaged the asteroids and outer satellites. We calculated two to three different positions of the asteroids, with different star fields, to best obtain positions. We obtained many different accurate positions of asteroids and the observing conditions, which were noted, inputted, then reduced with other data. We submit our data to the Minor Planet Center, and by the Solar System Dynamics (SSD) group at JPL. The data are also used for predicting occulting events. Through the execution of several Linux reduction programs and scripts, we reduce the data for the most accurate orbital positions.

Carr, Alexander G.↗

Recycling positive-electrode material of a lithium-ion battery

Examples are disclosed of methods to recycle positive-electrode material of a lithium-ion battery. In one example, the positive-electrode material is heated under pressure in a concentrated lithium hydroxide solution. After heating, the positive-electrode material is separated from the concentrated lithium hydroxide solution. After separating, the positive electrode material is rinsed in a basic liquid. After rinsing, the positive-electrode material is dried and sintered.

25 ENERGY STORAGE↗

HOM Choice Study with Test Electronics for use as Beam Position Diagnostics in 3.9 GHz Accelerating Cavities in FLASH

Higher Order Modes (HOM) excited by the beam in the 3.9 GHz accelerating cavities in FLASH can be used for beam position diagnostics, as in a cavity beam position monitor. Previous studies of the modal choices within the complicated spectrum have revealed several options: cavity modes with strong coupling to the beam, and therefore with the potential for better position resolution, but which are propagating within all 4 cavities, and modes localized in the cavities or the beam pipes, which can give localized position information, but which provide worse resolution. For a better characterization of these options, a set of test electronics has been built, which can down-convert various frequencies between about 4 and 9 GHz to 70 MHz. The performance of various 20 MHz bands has been estimated. The best resolution of 20 \mu m was found for some propagating modes. Based on this study one band at ca. 5 GHz was chosen for high resolution position monitoring and a band at ca. 9 GHz for localized monitoring.

43 PARTICLE ACCELERATORS↗

A Study of Beam Position Diagnostics with Beam-excited Dipole Higher Order Modes using a Downconverter Test Electronics in Third Harmonic 3.9 GHz Superconducting Accelerating Cavities at FLASH

Beam-excited higher order modes (HOM) in accelerating cavities contain transverse beam position information. Previous studies have narrowed down three modal options for beam position diagnostics in the third harmonic 3.9 GHz cavities at FLASH. Localized modes in the beam pipes at approximately 4.1 GHz and in the fifth cavity dipole band at approximately 9 GHz were found, that can provide a local measurement of the beam position. In contrast, propagating modes in the first and second dipole bands between 4.2 and 5.5 GHz can reach a better resolution. All the options were assessed with a specially designed test electronics built by Fermilab. The aim is to define a mode or spectral region suitable for the HOM electronics. Two data analysis techniques are used and compared in extracting beam position information from the dipole HOMs: direct linear regression and singular value decomposition. Current experiments suggest a resolution of 50 {\mu}m accuracy in predicting local beam position using modes in the fifth dipole band, and a global resolution of 20 {\mu}m over the complete module. Based on these results we decided to build a HOM electronics for the second dipole band and the fifth dipole band, so that we will have both high resolution measurements for the whole module, and localized measurements for individual cavity. The prototype electronics is being built by Fermilab and planned to be tested in FLASH by the end of 2012.

43 PARTICLE ACCELERATORS↗

Optimization study of B4C filter thickness for shifting to fast spectrum at experimental position in NRAD core

The Japan Atomic Energy Agency (JAEA) has investigated an accelerator-driven system (ADS) to transmute minor actinides (MAs) partitioned from the high level waste. In the nuclear transmutation system such as the ADS, the nuclear data validation of MA is required to reduce the uncertainty caused by the nuclear data of MA. In order to validate the nuclear data, many independent experimental data need to be mutually compared. The Idaho National Laboratory (INL) considers the measurement of fission rate ratio and sample worth with a wide spectral indices by inserting several types of thermal neutron shielding filters in the experimental position in Neutron RADiography (NRAD) which is the thermal neutron reactor. The JAEA has a plan to perform integral experiments with fission chambers in the NRAD because of the expansion of the experimental data contributing to nuclear data validation of MA. In this study, the optimization of the NRAD core configuration, the B4C filter thickness, and the experimental position design was conducted to acquire the high-accuracy and the beneficial experimental data by using MCNP 6.1 and ENDF/B-VII.1. First, by locating the experimental position as close to the center of the core as possible and concentrating the fuel around that position, the neutron flux of the optimized model could be constructed 2.5 times as much as that of the previous model. Second, the optimized B4C filter thickness was determined to be 3mm based on the comprehensive evaluation from the viewpoints of the shielding ability of low energy neutrons, the level of the total neutron flux, and the influence of fabrication accuracy of the B4C filter. Third, we constructed the experimental position model that could further reduce the influence of the low energy neutrons by adopting the aluminum dry box and the bottom filter. Moreover, the neutron energy spectrum of the tentative optimized model constructed by following the above results was compared with that of the fast neutron reactors such as the ADS and the Fast Critical Assembly (FCA). As a result, the tentative optimized model would be able to be obtained the beneficial experimental data for the verification of FCA-IX series data and the validation of MA nuclear data for accuracy improvement of ADS design. Furthermore, the adoption of the tentative optimized model would be acquired the experimental data such as fission reaction rate and sample worth with the wider spectral indices than the previous one because the tentative optimized model would be able to increase the ratio of the fast neutrons by almost completely eliminating the effect of the thermal neutrons.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Positive Social License Solicitation and Affiliation Development through Non-Traditional Engagement Vectors - 19423

Generally speaking, the nuclear industry is very effective at accepting the positive and educated merits of 'all things nuclear,' including rationales for nuclear power supply, fuel, and waste-related considerations. However, the general public on average tends to be invariably wary of the nuclear industry, especially when it comes to waste management considerations, and furthermore, is greatly swayed by public sentiment and influences that suggest that 'nuclear is ominous.' This stance is especially true when it comes to waste management. This paper is based on the premise that traditional engagement and social license solicitation initiatives are at best, marginally effective at influencing the favorability within public opinion. However, there is tremendous opportunity and untapped potential to engage in a more meaningful and effective manner, by adopting a more holistic and fundamental approach to social engagement and public influence. This paper elaborates on this approach by presenting sustainable, effective strategies for practical methods of non-traditional social engagement to introduce, expose, educate, inform, develop, and influence a non-biased appreciation for nuclear industry considerations. Starting from a belief that early exposure and awareness of the nuclear industry through indirect engagement manifests a non-threatening, positive affinity for the subject matter, a sustained, deliberate, and multi-vector engagement campaign is effective at establishing a pro-nuclear disposition. Additionally, rather than relying on a few established and known (and perhaps perceived as biased) advocacy entities, this paper establishes a methodology of mobilizing a varied and wide range of indirect stakeholders to disseminate and manifest the desired-and unbiased-message. In effect, rather than coming from a position where traditional industry advocacy sources vie and lobby for disseminating the merits and realities of the industry, this strategy establishes a means to have non-biased, non-nuclear agents 'tell the story' about the nuclear industry. Practical examples will be provided detailing how some of the proposed methodologies have been successfully deployed. This includes hosting a province- (state)-wide technical competition for 100+ elementary school children, using the context and narrative of a spent-fuel removal and storage-handling system. This specific experience resulted from introducing complex nuclear concepts and environments in a very accessible manner to the young students, while also capitalizing on the curiosity of the their parents, teachers, friends, and community in an open and engaging information and awareness initiative that they would not have otherwise encountered through the traditional engagement vectors. With continued similar experiences, this cohort will become part of the desired voting demographic faced with questions and decisions around nuclear power, waste handling, and storage. Drawing upon their early engagement and deliberate exposure to the subject matter, over time, this audience will invariably result in a much more engaged, educated, informed, and positively-inclined demographic. In summary, a positive shift in the prevailing general public sentiment can be achieved through a a broad, long-term, and wide-reaching early engagement strategy. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Magnetic-Field Diffusion Effects in Beam Position Monitors III: Application to DARHT-II Beam Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present experimental validation of current and position results from a prototype detector employing finite conductivity sensing areas, based on experiments on the DARHT-II LIA.

43 PARTICLE ACCELERATORS↗

Attitude and position estimation on the Mars Exploration Rovers

NASA/JPL 's Mars Exploration Rovers acquire their attitude upon command and autonomously propagate their attitude and position. The rovers use accelerometers and images of the sun to acquire attitude, autonomously searching the sky for the sun with a pointable camera. To propagate the attitude and position the rovers use either accelerometer and gyro readings or gyro readings and wheel odometiy, depending on the nature of the movement ground operators are commanding. Where necessary, visual odometry is performed on images to fine tune the position updates, particularly in high slip environments. The capability also exists for visual odometry attitude updates. This paper describes the techniques used by the rovers to acquire and maintain attitude and position knowledge, the accuracy which is obtainable, and lessons learned after more than one year in operation.

attitude estimation↗

Comparing Digital Tomosynthesis to Cone-Beam CT for Position Verification in Patients Undergoing Partial Breast Irradiation

Purpose: To evaluate digital tomosynthesis (DTS) technology for daily positioning of patients receiving accelerated partial breast irradiation (APBI) and to compare the positioning accuracy of DTS to three-dimensional cone-beam computed tomography (CBCT). Methods and Materials: Ten patients who underwent APBI were scanned daily with on-board CBCT. A subset of the CBCT projections was used to reconstruct a stack of DTS image slices. To optimize soft-tissue visibility, the DTS images were reconstructed in oblique directions so that the tumor bed, breast tissue, ribs, and lungs were well separated. Coronal and sagittal DTS images were also reconstructed. Translational shifts of DTS images were obtained on different days from the same patients and were compared with the translational shifts of corresponding CBCT images. Seventy-seven CBCT scans and 291 DTS scans were obtained from nine evaluable patients. Results: Tumor beds were best visible in the oblique DTS scans. One-dimensional positioning differences between DTS and CBCT images were 0.8-1.7 mm for the six patients with clips present and 1.2-2.0 mm for the three patients without clips. Because of the limited DTS scan angle, the DTS registration accuracy along the off-plane direction is lower than the accuracy along the in-plane directions. Conclusions: For patients receiving APBI, DTS localization offers comparable accuracy to CBCT localization for daily patient positioning while reducing mechanical constraints and imaging dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volume or Position Changes of Primary Lung Tumor During (Chemo-)Radiotherapy Cannot Be Used as a Surrogate for Mediastinal Lymph Node Changes: The Case for Optimal Mediastinal Lymph Node Imaging During Radiotherapy

Purpose: Primary lung tumors can be visualized mostly with cone beam computed tomography (CT), whereas visualization is much more difficult for mediastinal lymph nodes (LN). If the volumetric and positional changes of the primary tumor could be used as a surrogate for the LN, this would facilitate image-guided radiotherapy. The purpose of this study was to investigate the relationship between the positional and volumetric changes in primary tumors and the involved LN during (chemo)radiotherapy treatment of non-small-cell lung cancer patients. Methods and Materials: [{sup 18}F]fluorodeoxyglucose positron emission tomography/computed tomography imaging was performed before radiotherapy and in the second week of treatment in 35 patients. Gross tumor volumes (GTV) of the primary tumor (GTVprim) and of the involved LN (GTVlymph) were delineated. Changes in position and volume of GTVprim with respect to GTVlymph and the bony anatomy were compared. Results: In individual cases, large displacements up to 1.6 cm and volume changes of 50% of the primary tumor may occur that are not correlated to the changes in involved LN. The volume of GTVprim reduced, on average, by 5.7% {+-} 19.0% and was not correlated with the small increase of 1.4% {+-} 18.2% in involved LN volume. Compared to bony anatomy, displacement of the primary tumor was statistically correlated to the involved LN displacement. Conclusions: Volume and position changes of the primary tumor are not always predictive for LN changes. This suggests that for characterization of involved LN, repeated state-of-the-art mediastinal imaging during radiotherapy may be necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Setup Reproducibility of the Spinal Column When Using Intensity-Modulated Radiation Therapy for Craniospinal Irradiation With Patient in Supine Position

Purpose: To evaluate local positioning errors of the lumbar spine during fractionated intensity-modulated radiotherapy of patients treated with craniospinal irradiation and to assess the impact of rotational error correction on these uncertainties for one patient setup correction strategy. Methods and Materials: 8 patients (6 adults, 2 children) treated with helical tomotherapy for craniospinal irradiation were retrospectively chosen for this analysis. Patients were immobilized with a deep-drawn Aquaplast head mask. Additionally to daily megavoltage control computed tomography scans of the skull, once-a-week positioning of the lumbar spine was assessed. Therefore, patient setup was corrected by a target point correction, derived from a registration of the patient's skull. The residual positioning variations of the lumbar spine were evaluated applying a rigid-registration algorithm. The impact of different rotational error corrections was simulated. Results: After target point correction, residual local positioning errors of the lumbar spine varied considerably. Craniocaudal axis rotational error correction did not improve or deteriorate these translational errors, whereas simulation of a rotational error correction of the right-left and anterior-posterior axis increased these errors by a factor of 2 to 3. Conclusion: The patient fixation used allows for deformations between the patient's skull and spine. Therefore, for the setup correction strategy evaluated in this study, generous margins for the lumbar spinal target volume are needed to prevent a local geographic miss. With any applied correction strategy, it needs to be evaluated whether or not a rotational error correction is beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Online Kidney Position Verification Using Non-Contrast Radiographs on a Linear Accelerator with on Board KV X-Ray Imaging Capability

The kidneys are dose-limiting organs in abdominal radiotherapy. Kilovoltage (kV) radiographs can be acquired using on-board imager (OBI)-equipped linear accelerators with better soft tissue contrast and lower radiation doses than conventional portal imaging. A feasibility study was conducted to test the suitability of anterior-posterior (AP) non-contrast kV radiographs acquired at treatment time for online kidney position verification. Anthropomorphic phantoms were used to evaluate image quality and radiation dose. Institutional Review Board approval was given for a pilot study that enrolled 5 adults and 5 children. Customized digitally reconstructed radiographs (DRRs) were generated to provide a priori information on kidney shape and position. Radiotherapy treatment staff performed online evaluation of kidney visibility on OBI radiographs. Kidney dose measured in a pediatric anthropomorphic phantom was 0.1 cGy for kV imaging and 1.7 cGy for MV imaging. Kidneys were rated as well visualized in 60% of patients (90% confidence interval, 34-81%). The likelihood of visualization appears to be influenced by the relative AP separation of the abdomen and kidneys, the axial profile of the kidneys, and their relative contrast with surrounding structures. Online verification of kidney position using AP non-contrast kV radiographs on an OBI-equipped linear accelerator appears feasible for patients with suitable abdominal anatomy. Kidney position information provided is limited to 2-dimensional 'snapshots,' but this is adequate in some clinical situations and potentially advantageous in respiratory-correlated treatments. Successful clinical implementation requires customized partial DRRs, appropriate imaging parameters, and credentialing of treatment staff.

61 RADIATION PROTECTION AND DOSIMETRY↗

Using 3D position sensitivity to reveal response non-uniformities in CdZnTe, TlBr, and CsPbBr 3 detectors

Position sensitivity enables the correction of response non-uniformities in room-temperature semiconductor detectors caused by crystal defects and other factors. It can also be used to pinpoint the exact location of crystal defects responsible for the response variations. This work describes a technique for revealing and visualizing the detector regions affecting the charge collection efficiency in CdZnTe (CZT), TlBr, and CsPbBr 3 detectors configured as position-sensitive virtual Frisch-grid (VFG) devices. The technique correlates the photopeak events in energy spectra with their spatial distributions inside the detectors using the position information. By selecting the events from narrow energy intervals within a photopeak, we can visualize the detector volumes with particular charge collection efficiencies, which, in turn, correlate with the locations of electrode and crystal defects. Here, we demonstrate this technique in several examples. Columnar structures in the volume plots (position distribution maps) are consistent with signal losses near or at the anode in selected samples of CZT and TlBr. Structures exhibiting a distinct depth dependence are consistent with grain boundaries or other crystal defects.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Rotational positioning system adapted to atomic force microscope for measuring anisotropic surface properties

The diverse atomic configurations induce the anisotropic surface properties. For investigating anisotropic phenomena, we developed a rotational positioning system adapted to atomic force microscope (AFM). This rotational positioning system is applied to revolve the measured sample to defined angular direction, and it composed of an inertial rotational stepper and a visual angular measurement. The inertial rotational stepper with diameter 30 mm and height 7.6 mm can be easily attached to the AFM-system built in any general optical microscope. Based on a clearance less bearing and the inertial driving method, its bidirectional angular resolution reaches 0.005 deg. per step. For realizing a close-loop controlled angular positioning function, the visual measurement method is utilized. Through the feedback control, the angular positioning error is less than 0.01 deg. For verifying the system performance, we used it to investigate the anisotropic surface properties of graphite. Through a modified cantilever tip, the atomic-scale stick-slip, and the anisotropic friction phenomena can be distinctly detected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental energy resolution of a paracentric hemispherical deflector analyzer for different entry positions and bias

A specially designed hemispherical deflector analyzer (HDA) with 5-element input lens having a movable entry position R{sub 0} suitable for electron energy analysis in atomic collisions was constructed and tested. The energy resolution of the HDA was experimentally determined for three different entry positions R{sub 0}= 84, 100, 112 mm as a function of the nominal entry potential V(R{sub 0}) under pre-retardation conditions. The resolution for the (conventional) entry at the mean radius R{sub 0}= 100 mm was found to be a factor of 1.6-2 times worse than the resolution for the two (paracentric) positions R{sub 0}= 84 and 112 mm at particular values of V(R{sub 0}). These results provide the first experimental verification and a proof of principle of the utility of such a paracentric HDA, while demonstrating its advantages over the conventional HDA: greater dispersion with reduced angular aberrations resulting in better energy resolution without the use of any additional fringing field correction electrodes. Supporting simulations of the entire lens plus HDA spectrometer are also provided and mostly found to be within 20%-30% of experimental values. The paracentric HDA is expected to provide a lower cost and/or more compact alternative to the conventional HDA particularly useful in modern applications utilizing a position sensitive detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact integrated X-ray intensity and beam position monitor based on rare gas scintillation

We have created and tested a compact integrated X-ray beam intensity and position monitor using Ar-gas scintillation. The light generated inside the device's cavity is detected by diametrically opposed PIN diodes located above and below the beam. The intensity is derived from the sum of the top and bottom signals, while the beam position is calculated from the difference-over-sum of the two signals. The device was tested at Cornell High Energy Synchrotron Source with both 17 keV and 59 keV x-rays. For intensity monitoring, the Ar-scintillation monitor performance is comparable to standard ion chambers in terms of precision. As an X-ray beam position monitor the new device response is linear with vertical beam position over a 2 mm span with a precision of 2 {mu}m.

43 PARTICLE ACCELERATORS↗