Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “photocathodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Multi-mode optical sensor (B) evaluation test report

An evaluation test series was performed on the unit to develop realistic specifications for a similar device for use on the orbiter vehicle. Tests included sensitivity, target dynamic range, tracking angular rate, external magnetic field effects, and photocathode uniformity. Several demonstrations of operation under automatic control were also prepared, using a desk calculator for numerical control and for subsequent reduction of data derived from the test.

Smith, R. A.↗

Electronic magnification for astronomical camera tubes

Definitions, test schemes, and analyses used to provide variable magnification in the image section of the television sensor for large space telescopes are outlined. Experimental results show a definite form of magnetic field distribution is necessary to achieve magnification in the range 3X to 4X. Coil systems to establish the required field shapes were built, and both image intensifiers and camera tubes were operated at high magnification. The experiments confirm that such operation is practical and can provide satisfactory image quality. The main problem with such a system was identified as heating of the photocathode due to concentration of coil power dissipation in that vicinity. Suggestions for overcoming this disadvantage are included.

Vine, J.↗

Lyman-alpha imagery of comet Kohoutek, and far-UV magnitudes of stars

The Apollo-16 S201 electronographic camera backup model was modified for use on the Skylab AMS-SAL, which reduced its 20 deg FOV to about 7 deg unvignetted. Over 500 frames were exposed by automatic sequencer through LiF and CaF2. The Lyman-alpha halo of comet Kohoutek has been analyzed for nine occasions, and its long, pointed tail was imaged in 1250-1600 A only near perihelion. Far-UV magnitudes and colors are being derived for about 200 stars, nebulae, and galaxies. Redshifted Lyman-alpha emission from intergalactic atomic hydrogen was not detected in 7 clusters of galaxies. About 25% of the exposed frames were degraded by water damage, electrical discharges, decline in photocathode sensitivity, and loss of AMS mirror reflectance.

Page, T.↗

Photomultiplier window materials under electron irradiation - Fluorescence and phosphorescence

The fluorescence and phosphorescence of photomultiplier window materials under electron irradiation have been investigated using a Sr-90/Y-90 beta emitter as the electron source. Spectral emission curves of UV-grade, optical-grade, and electron-irradiated samples of MgF2 and LiF, and of CaF2, BaF2, sapphire, fused silica, and UV-transmitting glasses were obtained over the 200-650-nm spectral range. Fluorescence yields were determined on these materials utilizing photomultiplier tubes with cesium telluride, bialkali, and trialkali (S-20) photocathodes, respectively. Optical-grade MgF2 and LiF, as well as electron-irradiated UV-grade samples of these two materials, show enhanced fluorescence due to color-center formation and associated emission bands in the blue and red wavelength regions. Large variations in fluorescence intensities were found in UV-grade sapphire samples of different origins, particularly in the red end of the spectrum, presumably due to various amounts of chromium-ion content. Phosphorescence decay with time is best described by a sum of exponential terms, with time constants ranging from a few minutes to several days.

Viehmann, W.↗

Magnifying image intensifier

Coil assembly for zoom operation produces axial magnetic flux density that decreases in strength from photocathode to target. This results in magnification factor greater than unity. To extend magnification range, field is reversed in direction between object and image planes.

Vine, J.↗

Effects of 1- and 2-MeV electrons on photomultiplier tubes

Various types of photomultiplier tubes useful for space applications were irradiated with 1- and 2-MeV electrons at Van Allen radiation belt fluxes of 100,000 to 10 millions electrons/sq cm-sec. The increase in the dark current due to electron irradiation was observed at various bias voltages under worst-case conditions (no shielding). Results were presented in the form of dark current plotted against electron flux. All the tubes tested showed extremely large increases in dark current. Tube types 541A, 6217, 6199, and 6903 exhibited the largest increases under irradiation, whereas type 1P22 was affected the least. All the damage observed was transient. The luminescence produced in the optical window probably accounts for a large part of the dark-current increases, but there were some effects possibly due to direct irradiation of the photocathode and dynode chain.

Beatty, M. E., III↗

High resolution spectrograph

The high resolution spectrograph (HRS) is designed to be used with the Large Space Telescope (LST) for the study of spectra of point and extended targets in the spectral range 110 to 410 nm. It has spectral resolutions of 1,000; 30,000; and 100,000 and has a field of view as large as 10 arc sec. The spectral range and resolution are selectable using interchangeable optical components and an echelle spectrograph is used to display a cross dispersed spectrum on the photocathode of either of 2 SEC orthicon image tubes. Provisions are included for wavelength calibration, target identification and acquisition and thermal control. The system considerations of the instrument are described.

Peacock, K.↗

A photon counting array photometer using an intensified charge coupled device

An array photometer which uses an intensified charge coupled device was developed. This system, the University of Maryland Array Photometer (UMAP), has the ability to discriminate single photoelectron events in real time at a 4 Megahertz rate. The photosensor uses an S-20 photocathode and a Fairchild CCD202 with a 100 by 100 array of separate individual channels. The overall system has demonstrated a noise level which permits single photoelectron discrimination, a scan rate of 400 frames per second, a very linear response, and very low lag. The UMAP system has a very large dynamic range exceeding 10,000 in the photon counting mode. A special technique to extend the dynamic range to 1,000,000 was described. The performance parameters of this system, both in the laboratory and on the telescope were cited. Data from these observations were discussed to illustrate the system sensitivity, which is basically limited by the pixel size in the array, rather than the electrooptics.

Currie, D. G.↗

Photomultiplier tube development for the 1.06 micrometer wavelength

High speed, electrostatic photomultipliers were developed for use in 400 megabit laser communication systems operating at the 1.06 micron wavelength. A high performance, electrostatic III-V photocathode PMT was shown in communication system tests to perform competitively with solid state and avalanche photodiodes. Signal-induced noise and III-V cathode stability were identified as remaining technical problems while cathode quantum efficiencies of or = 5% at 1.06 micron and 320 picosecond rise and fall time pulse performance were achieved.

Enck, R. S., Jr.↗

High speed electrostatic photomultiplier tube for the 1.06 micrometer wavelength. Cup and slat dynode chain combined with flat cathode and coax output produces 0.25 nsec rise time

The Varian cup and slat dynode chain was modified to have a flat cathode. These modifications were incorporated in an all-electrostatic photomultiplier tube having a rise time of 0.25 n sec. The tube delivered under the contract had a flat S-20 opaque cathode with a useful diameter of 5 mm. The design of the tube is such that a III to V cathode support is mounted in place of the existing cathode substrate. This cathode support is designed to accept a transferred III to V cathode and maintain the cathode surface in the same position as the S-20 photocathode.

Sparks, S. D.↗

Intensified charge coupled devices for ultra low light level imaging

Development of a sensor incorporating a CCD and photocathode for operation in the electron bombarded mode in both a magnetic and an electrostatic focussed, gated configuration is described. Initial format size is 100 x 160 pixels with eventual growth to 400 x 400 pixels. The sensor is part of a digital camera system which includes the low level video conditioning electronics, a camera controller, a high speed buffer memory, and digital recording and display electronics. The memory uses CMOS/SOS and has a capacity of 1.6 Mbits with operating rates of 48 Mbits/sec. Individual frames are co-added to provide wide dynamic range and photometric precision better than 1%. A 4-bit video quantization is used to increase the photon counting detection rate before coincidence losses become serious.

Sobieski, S.↗

The Photicon

The Photicon is a novel imaging optical detector utilizing a conventional semitransparent photocathode, imaging electrostatic optics, microchannel plates, and a crossed-wire-grid position-sensitive charge detector. Its sensitivity to single optical photons over a two-dimensional area, high-resolution imaging, and timing capability render it useful for recording scintillations from X-ray image converters in X-ray astronomy. A digital word indicating the position of a single photon event is produced; the image can be stored in an array or serially. Spatial resolution to 20 microns in a 25 mm diam active area detector is reported, and modifications to achieve a spectral range of 120-730 nm are mentioned.

Kellogg, E.↗

Magnifying image intensifier

A magnetically focused image intensifier was improved to increase the usable range of magnification without degradation of image quality. The power requirements of the focusing coils are minimal. The arrangement of the focusing coils reverses the direction of the axial magnetic field distribution between the planes of the photocathode and the phosphor screen.

Vine, J.↗

High resolution imaging X-ray detector for astronomical measurements

The article describes the X-ray detector which will provide second-of-arc images for the HEAO-B X-ray observatory. The instrument uses microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. Position determination is accomplished by electronic interpolation between the coarse grid wires. The detector provides the arrival time and position of each event which occurs within its field of view. Measurements of the spatial resolution (15 microns), temporal resolution (7.8 microsec), image distortion (less than 10 microns), uniformity of efficiency (less than plus or minus 10%), dark counting rate (0.2 cts/sq cm/s), and quantum efficiency (10% at 1.54 keV) of this detector are described. A summary of the procedure which was found useful during the initial turn-on of microchannel plates is given.

Henry, J. P.↗

Electrostatically focused intensified charge coupled devices

Work performed to develop intensified charge coupled devices (ICCDs) is presented. Four ICCDs, containing 100 x 160 arrays, were fabricated. Electron gains up to 3200 at 15 keV were achieved. Photocathode sensitivities ranged from 190 to 410 micro A/lumen. Dark currents varied from 11 nA/sq cm to 37 nA/sq cm. There was serious concern about the reliability of the bonding scheme for ICCDs due to occassional bond failure. Two solutions to this problem were developed. One involved a modification of the existing bonding technique, and the other was the development of a protected bond pad employing a barrier metal between the aluminum metallization and the gold bond wire. An accumulation process was characterized with respect to its most critical variable. This characterization led to the achievement of reproducible spectral response and the discovery and elimination of dark current increase associated with this process.

Walker, J. W.↗

Optical infrared sky survey

A description is presented of a photographic survey of the northern sky currently underway at Steward Observatory. The survey is being conducted at a principal bandpass of 8000-9000 A supplemented by a V bandpass. The survey is the first of its type conducted using a small (20-in. aperture) wide-field telescope, a very large-format (146 mm) image intensifier with a red-extended, multialkali photocathode. The output phosphor of the intensifier is photographed with IIaD emulsion on film. One of the goals of the survey is to catalog red stellar objects on the photographs and to examine in detail regions of the sky which are obscured by hydrogen emission on conventional photographs.

Craine, E. R.↗

Effects of 1-MeV gamma radiation on a multi-anode microchannel array detector tube

A multianode microchannel array (MAMA) detector tube without a photocathode was exposed to a total dose of 1,000,000 rads of 1-MeV gamma radiation from a Co-60 source. The high-voltage characteristic of the microchannel array plate, average dark count, gain, and resolution of pulse height distribution characteristics showed no degradation after this total dose. In fact, the degassing of the microchannels induced by the high radiation flux had the effect of cleaning up the array plate and improving its characteristics.

Timothy, J. G.↗

Optical infrared sky survey instrumentation

An unusual, highly modified, Baker reflector-corrector class telescope has been adapted for wide field survey photography in the near infrared. This optical system uses a full field corrector plate and a field flattening lens to provide a flat field subtending about 4.5 deg on the sky. The small aperture telescope (20 inch primary) has been modified for use in the Newtonian focus configuration while preserving the optical elements of the Prime focus configuration. The telescope has been further modified to accept a very large format (146mm diameter photocathode) image intensifier camera to serve as a detector. The camera output is recorded photographically on film rather than glass plates. This unique instrument system is used in a program of sky survey photography in the optical infrared (8000-9000A bandpass) supplemented by visual bandpass photography. The photographs obtained with this system are of value not only for the extreme redness of the band but also because of their high resolution and their freedom from hydrogen emission.

Craine, E. R.↗