At least 451 records · Page 25

Validation Exercise of a Coarse Finite Element Model of Laser Welds

The objective of this project is to validate low-fidelity models of 304L to 304L stainless steel partial-penetration laser welds for thin sheets. Low-fidelity means that the weld is represented by coarsely meshed element blocks. Here, the hexahedral element size is approx imately half the weld penetration depth. The material behavior of the block is represented by a J2 plasticity model with a Voce hardening function. The source of the data used in this work is an extensive experimental study conducted by Sharlotte Kramer (1528) and published in 2015. Figure 1 shows a cross-section of the weld of interest. The nominal thickness of the sheets is 0.063 in. while the target penetration depth of the weld is in the range of 0.028 to 0.032 in., extending about half the sheet thickness. Uniaxial tension tests provided data for calibration of base material and weld models. Results of two validation geometries were also provided. The principal validation geometry is shown in Fig. 2. It consists of a plate specimen with in-plane dimensions 6 in × 2.875 in loaded in tension. A circular plug with a 1.5 in. diameter was cut from the center of the plate and then welded in place. The details of the welding schedule are given. An important assumption is that the welds in the calibration and validation specimens have similar geometric and material properties as those in the validation tests. The task was to first calibrate models for the base material and the welds and then simulate the validation tests until the point of weld first failure.

36 MATERIALS SCIENCE↗

A Review of Value of Solar Studies In Theory and In Practice

This brief summarizes a collection of state- and utility-commissioned value-of-solar (VoS) studies and related literature, with a focus on who commissioned the study, which value and cost categories were discussed and/or quantified, and the methods used. Our objective is to compile information on prior VoS studies to inform state regulators and other stakeholders that may pursue related studies or integrate findings into rate design. The brief is organized into three parts: 1) an introduction to distributed solar photovoltaic (DPV) compensation; 2) a review of theoretical research on VoS; and 3) a review of VoS studies. The vast majority of VoS studies have served an informational role of quantifying the net benefits of PV. Three studies were commissioned in states or utility service territories that subsequently implemented VoS tariffs in California, New York, and Austin, Texas. When applied as a tariff, VoS aims to compensate PV output as efficiently as possible by doing so at rates that reflect the marginal benefits and costs of PV through value and cost categories that may vary temporally and/or geographically. This could lead to higher compensation in locations and times where more PV output is more valuable and consequently drive adoption in those locations to provide more societal benefits. Value and cost factors can be broadly grouped into five categories: generation, transmission, distribution, other utility, and other social categories. Those conducting VoS studies must weigh various tradeoffs when deciding which categories to include and quantify. Tradeoffs include prioritizing values based on their magnitude of value or cost impact, as well as taking into account the feasibility of data collection and accurate quantification. Values of higher magnitude and estimation feasibility are quantified in the majority of studies, including the earliest of studies conducted in the 2000s and 2010s. Additionally, some values of higher magnitude but low feasibility in the earliest of studies have become quantifiable in recent years. There are some values with low average system-wide levels but very high magnitude in specific locations or hours. The value magnitude in some cases can be tied to DPV penetration with low value in areas with little congestion and/or low penetration and vice versa. In these cases, values that are easier to quantify are often incorporated, while those that are more difficult are often addressed via a placeholder value. The placeholder value is paired with a discussion around data needs and methods to improve future estimates, as well as a conversation about when these value categories may increase in magnitude and necessitate more rigorous quantification. This brief summarizes findings from two meta-analyses of VoS studies that took place between 2005 and 2018, as well as findings from four additional studies published from 2018 to 2023. Table ES-1 summarizes the various value and cost categories included in each respective study and whether they were quantified, discussed, or omitted. Values such as avoided energy, capacity, transmission capacity, line losses, and avoided environmental costs are quantified in every study. Some categories were deemed harder to quantify and less impactful at the time of the study, so they were discussed but not quantified (e.g., ancillary services). Other categories, including many at the distribution level, were very locationally and/or temporally specific and dependent on high DPV penetration. These were sometimes quantified and at other times discussed. Notably, when it came to utility costs, integration costs were discussed in all cases, though they were deemed to have a small impact. Other utility costs were omitted for the most part; however, the utility-commissioned study (by NorthWestern Energy in Montana) included both lost utility revenue and programmatic/administrative cost categories. While there are some similarities across studies, each had fairly unique methods that are detailed in the body of this brief.

14 SOLAR ENERGY↗

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

Prototype Hanford Barrier Performance Monitoring Report: Fiscal Year 2024

This report provides an annual update on performance monitoring of the Prototype Hanford Barrier (PHB) at the Hanford Site. The PHB is part of a long-term study that serves as the scientific basis for many of the evapotranspiration-capillary barrier designs currently used globally and for future engineered barrier designs planned for remedial actions over waste and demolition sites at the Hanford Site. The PHB allows us to identify potential future issues and develop better monitoring techniques before these engineered barriers are constructed. Surface barriers like the PHB are essential for preventing water infiltration and curbing the spread of contaminants to groundwater. Effective monitoring of soil moisture levels above and below these barriers is crucial given that performance metrics could span up to 1,000 years. From July 2023 to June 2024, the water flux (as measured by tipping buckets) through the 2-m-thick silt loam layer of the PHB – a fine silty material that stores water under high capillary tension – remained well below the 0.5-mm-per-year performance threshold, demonstrating its effectiveness in preventing water penetration. In 2024, degraded tipping bucket gauges were replaced to ensure the accuracy of future data. Additionally, neutron probes revealed that the wetting front from the rainy season only penetrated to a maximum depth of 1.2 m into the silt loam. This further demonstrated the barrier's efficiency, as the wetting front did not fully penetrate the 2-m-thick capillary barrier. The western gravel slope of the PHB, composed of Hanford Site pit gravel of varying sizes, demonstrated low flux rates. In contrast, the eastern riprap slope exhibited higher flux rates. Zhang (2017) found that the riprap side slope of the PHB had the highest drainage rates in January and the lowest in late summer or early fall, indicating significant summer evaporation. Drainage rates increased significantly under enhanced precipitation conditions, far exceeding the design criterion, which could lead to water infiltration into the waste zone. The study introduced the “edge effect,” where elevated drainage rates from the riprap may migrate laterally beneath the barrier, compromising its ability to isolate waste, and recommended expanding the barrier and conducting further research to mitigate this issue. This report provides a review on surface barrier edge effects and their potential impact to subsurface contaminant migration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tests of a High Temperature Sample Conditioner for the Waste Treatment Plant LV-S2, LV S3, HV S3A and HV-S3B Exhaust Systems

Tests were performed to evaluate a sample conditioning unit for stack monitoring at Hanford Tank Waste Treatment and Immobilization Plant (WTP) exhaust stacks with elevated air temperatures. The LV-S2, LV-S3, HV-S3A and HV-S3B exhaust stacks are expected to have elevated air temperature and dew point. At these emission points, exhaust temperatures are too high to deliver the air sample directly to the required stack monitoring equipment. As a result, a sample conditioning system is considered to cool and dry the air prior to its delivery to the stack monitoring system. The method proposed for the sample conditioning is a dilution system that will introduce cooler, dry air to the air sample stream. This method of sample conditioning is meant to reduce the sample temperature while avoiding condensation of moisture in the sample stream. An additional constraint is that the ANSI/HPS N13.1-1999 standard states that at least 50% of the 10 µm aerodynamic diameter (AD) particles present in the stack free stream must be delivered to the sample collector. In other words, depositional loss of particles should be limited to 50% in the sampling, transport, and conditioning systems. Based on estimates of particle penetration through the LV-S3 sampling system, the diluter should perform with about 80% penetration or better to ensure that the total sampling system passes the 50% or greater penetration criterion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fuel-Cladding Eutectic Study of Legacy Fast Flux Test Facility (FFTF) MFF HT9/U-10Zr Metallic Fuel

This report presents the first systematic investigation of fuel-cladding eutectic interaction (FCEI) in irradiated HT9/U-10Zr metallic fuel from the Fast Flux Test Facility (FFTF) Materials Fuels Form (MFF) program, using differential scanning calorimetry (DSC) coupled with scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). Two irradiated fuel cross-sections, MNT07H (9.5 at% burnup, x/L = 0.78) and MNT08H (7.0 at% burnup, x/L = 0.93), were subjected to three successive isothermal annealing rounds (R1–R3) at 820°C for 20 minutes each, yielding a cumulative transient duration of one hour. This study directly addresses a recognized gap in the existing FCEI database, which previously lacked irradiated HT9/U-10Zr data at burnup levels above 8 at%. Two principal findings emerge from the study. First, for both samples, FCEI remained spatially confined within the pre-existing fuel-cladding chemical interaction (FCCI) zone boundaries after R3, with no measurable eutectic penetration into unaffected cladding beyond the original FCCI layer. This self-limiting behavior is consistent with historical Fuel Behavior Test Apparatus (FBTA) results and is attributed to the near-eutectic phase composition of the FCCI zone, which rapidly absorb the available eutectic-forming constituents and then stall penetration once the FCCI zone is consumed. A comparison with unirradiated surrogate data further supports this mechanism: whereas a U–34 at.% Fe sample would be expected to show ~176 µm of iron penetration under comparable conditions, the irradiated samples exhibited only ~20 µm, a discrepancy attributed to irradiation-induced interfacial porosity and pre-existing FCCI composition gradients. Second, for MNT08H, FCEI was observed exclusively on the half of the cladding circumference where pre-existing steady-state FCCI was present, with no detectable FCEI on the opposite half. Three hypotheses are proposed to explain this asymmetry: the inhibiting role of a zirconium-rich rind at the fuel-cladding interface; the chemical sequestration of iron by redistributed zirconium within the fuel matrix; and the persistence of fuel-cladding gaps on the FCEI-free half that preclude direct contact. All three hypotheses require further experimental investigation. The results extend the empirical FCEI database into higher-burnup territory and demonstrate the viability of DSC-based testing as a substitute for the no-longer-available FBTA apparatus. Future work will include additional cross-section testing, compilation of the full FCEI dataset, model evaluation, and DSC testing of ternary fuel compositions to broaden the experimental basis for safety assessment of sodium-cooled fast reactor systems.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of Cone Penetrometer Testing on Shallow Hydrogeology at a Contaminated Site

Penetration testing is a popular and instantaneous technique for subsurface mapping, contaminant tracking, and the determination of soil characteristics. While the small footprint and reproducibility of cone penetrometer testing makes it an ideal method for in-situ subsurface investigations at contaminated sites, the effects to local shallow groundwater wells and measurable influence on monitoring networks common at contaminated sites is unknown. Physical and geochemical parameters associated with cone penetrometer testing were measured from a transect of shallow groundwater monitoring wells adjacent to penetrometer testing. For wells screened above the depth of cone refusal, the physical advancement and retraction of the cone had a significant effect ( p < 0.01) on water level for several pushes within 10 meters of a monitoring well, and a measured increase in specific conductivity. No effect on geochemistry or water level was observed in continuous monitoring data from wells screened below the depth of cone refusal, but variability in specific conductivity from these wells during penetration testing was only a fraction of the natural variation measured during precipitation events. Continuous measurements of specific conductivity and water level demonstrated that the effects of penetration testing have limited spatial and temporal distributions with a null effect post-testing.

54 ENVIRONMENTAL SCIENCES↗

Predicting cutoff L-shells of solar protons using the GPPSn particle dataset

Solar energetic protons (SEPs) arriving at the Earth trigger severe radiation storms in the near-Earth space, directly impacting space missions operating at various altitudes. Therefore, monitoring SEP events and predicting the penetration depths of solar protons are critical for aerospace sectors. Building on previous efforts, here we demonstrate the feasibility of using proton measurements from the Global Prompt Proton Sensor network (GPPSn), enabled by Los Alamos National Laboratory developed combined X-ray dosimeters aboard GPS satellites, to characterize and predict the penetration of solar protons into the geomagnetic field. The inclined medium-Earth-orbits (MEOs) of the global GPS constellation offer a unique advantage of allowing simultaneous measurements of penetrating solar protons inside both open- and closed-field line regions. Therefore, the L-profiles of ∼10s–100 MeV solar protons and their associated cutoff L-shells can be determined from the GPPSn dataset, using predefined threshold proton flux values rather than traditional flux ratios. After examining a list of SEP event intervals across solar cycles 23, 24 and 25—including the 2024 Mother’s Day superstorm, we showcase how the latest GPPSn proton dataset (release v1.10), reprocessed and calibrated, can not only be used to monitor solar proton distributions inside the dynamic geomagnetic field for individual events, but also to derive a new empirical model linking cutoff L-shells with several key space weather parameters. This newly developed SEPCL-MEO model demonstrates high predictive performance; for example, predictions for > 30 MeV solar protons yield a correlation coefficient of 0.85 and performance efficiency of 0.67 when validated against GPPSn observations. Results from this pilot study underscores the scientific and operational value of the GPPSn dataset, and this dataset—when paired with machine-learning techniques—can play a critical role in observing and predicting the effects of future incoming SEP events, including extreme ones.

58 GEOSCIENCES↗

Dynamic Optimal Dispatch of Energy Systems with Intermittent Renewables and Damage Model

With the increasing penetration of intermittent renewable energy sources into the grid, there is a growing need for process systems-based strategies that integrate dispatchable and variable energy systems for supplying the demand while maintaining grid reliability. The proposed framework corresponds to a dynamic mixed-integer linear programming optimization approach that integrates coal-fired and natural gas-fired power plants, NaS batteries for energy storage, and solar/wind energy to supply the demand. This optimization approach considers an economic goal and constraints to provide power balance while maintaining the overall damage of the natural gas combined cycle (NGCC) power plant drum under a maximum stress as well as avoiding the overheating of the NGCC superheater and reheater. Renewable curtailment levels are also retained at minimum levels. Case studies are analyzed considering different loads and renewable penetration levels. The results show that the demand was met for all cases. Grid flexibility was mostly provided by the NGCC, while the batteries were used sparingly. In addition, considering a CO 2 equivalent analysis, the environmental performance was intrinsically connected to grid flexibility and the level of renewable penetration. Stress analysis results reinforced the necessity for an equipment health-related constraint.

97 MATHEMATICS AND COMPUTING↗

Future Battery Material Demand Analysis Based on U.S. Department of Energy R&D Targets

The U.S. Department of Energy’s Vehicle Technologies Office (VTO) supports research, development, and deployment of efficient, sustainable transportation technologies that will improve energy efficiency and fuel economy, and enable America to use less petroleum. To accelerate the development and adoption of new technologies, VTO has developed specific targets for a wide range of powertrain components, including the energy storage system. In this study, we use Autonomie, Argonne National Laboratory’s (Argonne’s) vehicle system simulation tool to evaluate future energy storage requirements (power, energy, etc.) for different vehicle classes, powertrains, component technologies and timeframes. BatPac, Argonne’s tool dedicated to energy storage pack design and costs, is then used to quantify the materials required for each pack. Market penetrations are then used to estimate the overall material demand worldwide and in the United States, with or without recycling. The results demonstrate that the positive impact of VTO research and development will lead to significant reduction in material compared to business-as-usual due to new anode and cathode designs, along with acceleration in battery cell chemistry penetrations. In terms of material demands, it is observed that lithium demand reaches about 80,000 tons (by a factor of 42–45), nickel demand reaches about 500,000 tons (by a factor of 47–56), manganese demand reaches about 30,000–50,000 tons (by a factor of 20–34), and cobalt demand reaches about 30,000 tons (by a factor of 13–28) in the future by 2050. The individual material demand per unit energy, however, decreases significantly in the future due to advances in VTO research and development activities. The increase in battery material demands is mostly driven by increased electrified vehicle fleet penetration in the markets.

25 ENERGY STORAGE↗

Integration of Utility Distributed Energy Resource Management System and Aggregators for Evolving Distribution System Operators

With the rapid integration of distributed energy resources (DERs), distribution utilities are faced with new and unprecedented issues. New challenges introduced by high penetration of DERs range from poor observability to overload and reverse power flow problems, under-over-voltages, maloperation of legacy protection systems, and requirements for new planning procedures. Distribution utility personnel are not adequately trained, and legacy control centers are not properly equipped to cope with these issues. Fortunately, distribution energy resource management systems (DERMSs) are emerging software technologies aimed to provide distribution system operators (DSOs) with a specialized set of tools to enable them to overcome the issues caused by DERs and to maximize the benefits of the presence of high penetration of these novel resources. However, as DERMS technology is still emerging, its definition is vague and can refer to very different levels of software hierarchies, spanning from decentralized virtual power plants to DER aggregators and fully centralized enterprise systems (called utility DERMS). Although they are all frequently simply called DERMS, these software technologies have different sets of tools and aim to provide different services to different stakeholders. This paper explores how these different software technologies can complement each other, and how they can provide significant benefits to DSOs in enabling them to successfully manage evolving distribution networks with high penetration of DERs when they are integrated together into the control centers of distribution utilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stability of multi-population traffic flows

Traffic waves, known also as stop-and-go waves or phantom jams, appear naturally as traffic instabilities, also in confined environments as a ring-road. A multi-population traffic is studied on a ring-road, comprised of drivers with stable and unstable behavior. There exists a critical penetration rate of stable vehicles above which the system is stable, and under which the system is unstable. In the latter case, stop-and-go waves appear, provided enough cars are on the road. The critical penetration rate is explicitly computable, and, in reasonable situations, a small minority of aggressive drivers is enough to destabilize an otherwise very stable flow. This is a source of instability that a single population model would not be able to explain. Also, the multi-population system can be stable below the critical penetration rate if the number of cars is sufficiently small. Instability emerges as the number of cars increases, even if the traffic density remains the same (i.e., number of cars and road size increase similarly). This shows that small experiments could lead to deducing imprecise stability conditions.

97 MATHEMATICS AND COMPUTING↗

The value of wake steering wind farm flow control in US energy markets

Abstract. Wind farm flow control represents a category of control strategies for achieving wind-plant-level objectives, such as increasing wind plant power production and/or reducing structural loads, by mitigating the impact of wake interactions between wind turbines. Wake steering is a wind farm flow control technology in which specific turbines are misaligned with the wind to deflect their wakes away from downstream turbines, thus increasing overall wind plant power production. In addition to promising results from simulation studies, wake steering has been shown to successfully increase energy production through several recent field trials. However, to better understand the benefits of wind farm flow control strategies such as wake steering, the value of the additional energy to the electrical grid should be evaluated – for example, by considering the price of electricity when the additional energy is produced. In this study, we investigate the potential for wake steering to increase the value of wind plant energy production by combining model predictions of power gains using the FLOw Redirection and Induction in Steady State (FLORIS) engineering wind farm flow control tool with historical electricity price data for 15 existing US wind plants in four different electricity market regions. Specifically, for each wind plant, we use FLORIS to estimate power gains from wake steering for a time series of hourly wind speeds and wind directions spanning the years 2018–2020, obtained from the ERA5 reanalysis dataset. The modeled power gains are then correlated with hourly electricity prices for the nearest transmission node. Through this process we find that wake steering increases annual energy production (AEP) between 0.4 % and 1.7 %, depending on the wind plant, with average increases in potential annual revenue (i.e., annual revenue of production, ARP) 4 % higher than the AEP gains. For most wind plants, ARP gain was found to exceed AEP gain. But the ratio between ARP gain and AEP gain is greater for wind plants in regions with high wind penetration because electricity prices tend to be relatively higher during periods with below-rated wind plant power production, when wake losses occur and wake steering is active; for wind plants in the Southwest Power Pool – the region with the highest wind penetration analyzed (31 %) – the increase in ARP from wake steering is 11 % higher than the AEP gain. Consequently, we expect the value of wake steering, and other types of wind farm flow control, to increase as wind penetration continues to grow.

17 WIND ENERGY↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids: Preprint

Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids

Increasing penetration levels of inverter based distributed energy resources (DERs) impact the legacy distribution system protection. Inverter based DERs provide approximately 1.2-2 pu fault current. In systems with high penetration of inverter based DERs, it is difficult for over-current based protection schemes to differentiate between normal loading conditions and a fault. Directional, distance, and adaptive forms of protection schemes are also affected by low fault currents. This paper analyzes fault generated traveling wave (TW) based high-frequency signatures in the distribution system. In order to simulate such signatures, frequency-dependent distributed parameter line modeling approach is used in this research work to represent distribution lines and underground cables. Modified IEEE 13-bus medium voltage test system is modeled in electromagnetic transient simulation tool and multiple transient scenarios are simulated in this test system. The results are analyzed to understand the high-frequency signatures that can be used to detect and locate faults under high penetration of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Technical Performance of Refractory Liners for Molten Chloride Salt Thermal Energy Storage Systems

A chloride-based molten-salt system that uses a ternary blend of MgCl2/KCl/NaCl is investigated to provide higher temperature thermal energy storage capability. Despite higher thermal stability, molten chlorides present several unique challenges, including the design of internal refractory-ceramic liners to prevent the corrosion and thermal stress of alloy tank shells. This work discusses issues and potential solutions related to containment of molten chloride salt, specifically the optimization of the refractory material at the molten salt interface (hot face). The down-selected hot face candidate limits permeation of salt through the material and forms a highly stable secondary surface phase in equilibrium with the molten salt. A mortar is created using the corrosion resistant hot face brick. Brick and mortar composite are subjected to mechanical stress/strain analysis, in order to calculate composite material properties and better inform thermomechanical models. The U.S. Department of Energy Generation 3 (DOE Gen3) program seeks to develop higher efficiency CSP plants that can provide cost-competitive, flexible power in the U.S. electric grid. The proposed Gen3 Liquid Pathway CSP plant closely resembles the configuration of current nitrate salt power towers with two-tank storage (Gen2). The differences between Gen2 and Gen3 include the types of compatible materials used in salt storage tank construction. Stainless steel loses strength at Gen3 temperatures, and although nickel superalloys would be capable of withstanding sustained high temperatures, these materials are prohibitively expensive at scale. Uninsulated tank shells also pose a significant risk as common steels are highly susceptible to chemical attack from molten chloride salt. To address these concerns, refractory-ceramic based containment materials are proposed to line the inside of the hot and cold storage tanks. In doing so, stainless or carbon steel shells may be used in construction depending on the level of insulation provided. The composition of the internal liner requires careful consideration to maximize the efficacy of multiple parameters including corrosion resistance, strength at operating temperature, durability, and cost. This is particularly true for the material at the interface with the salt, known as the "hot face", which is responsible for protecting the insulating layers between the tank shell and the hot face brick layer. The molten salt in this system is superheated over 300 °C above its freeze temperature. Therefore, unlike other industrial processes which use refractory-lined vessels, it is not expected that a freeze plane will develop in the hot face. Therefore, the hot face must be designed to withstand chemical corrosion and inhibit permeation of molten salt into the insulating layers. A down selection was performed to identify a hot face candidate best equipped to maintain thermal, mechanical, and chemical integrity when exposed to molten salt over extended periods of time. Long-duration chemical capability experiments were conducted with the down selected hot face refractory fully immersed in molten chloride salt for up to 3000 hours. The average salt penetration does not exceed 100 microns. When extrapolated to 20 and 30 years of continuous exposure, the expected salt penetration depth is approximately 2.0 mm and 2.9 mm, respectively. A magnesium-rich secondary phases develops at the salt/refractory interface. X-ray diffraction identifies the material as forsterite (Mg2SiO4), which is reported to form synthetically in molten chloride salt solutions. These results suggest the selected hot face will adequately inhibit salt permeation. While there is optimism that the hot face brick will inhibit salt permeation, mortar joints are typically the weakest point of a refractory brick liner. From a thermochemical perspective, differing thermal expansion coefficients may result in the mortar and brick to grow independent of each other, creating gaps through which molten salt can penetrate. To address this issue, NREL has developed an in-house mortar composed of the down selected hot face brick that has been shown to be compatible with the salt. Compressive stress/strain analyses have been performed on the brick/ mortar composites to generate stress/strain curves. Modulus of elasticity and Poisson's ratio of the composite may be calculated from the stress/strain curves, in order to provide more representative data to finite element mechanical models for accurate approximation of stress on the tank shell and the amount of thermal expansion expected within the tank liner.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Absorbing the Sun: Operational Practices and Balancing Reserves in Florida's Municipal Utilities

The Florida Reliability Coordinating Council (FRCC) power system is comprised of multiple balancing authorities ranging in size from Gainesville Regional Utilities (GRU) with a 2019 summer net firm demand of 429 MW to Florida Power & Light with a 2019 summer net firm demand of 22,510 MW; and including cooperative, municipal, and investor-owned utilities. As all of these balancing authorities are and have plants to continue installing significant quantities of utility-scale solar photovoltaics, one relevant question is how much operating reserves they will need to hold as solar penetrations increase. While there are estimates of how regulating and flexibility reserve requirements change with solar penetration, the literature almost exclusively focuses on large balancing authorities with sub-hourly dispatch. In this work we analyze how reserve needs change not only with solar photovoltaic penetration, but also balancing authority size and operational practices. We find that, measured as a fraction of load, smaller balancing authorities with less frequent load and solar forecasts and less frequent dispatch need more reserves. Such utilities' reserve needs also increase more with increasing solar deployment as compared to larger or more frequently dispatched balancing authorities. These impacts are most acute for GRU. We find that moving from day-ahead to hour-ahead load and solar forecasting and system dispatch could enable GRU to incorporate 32% solar generation with median reserves at 20% instead of 60% of load; and that median reserve needs could drop further to about 10% of load if Florida's municipal utilities formed a reserve sharing group and moved to sub-hourly dispatch.

balancing authority↗

EMT Models to Evaluate Traveling Wave-Based Protection in Distribution System

The distribution system is going through significant changes. One of them is the high penetration of inverter-based distributed energy resources in the distribution system. Due to this high penetration, there is a need for a better protection system. Multiple organizations are working on creating novel protection techniques for distribution systems with high penetration of inverter-based DERs. One such innovative method is the use of traveling waves to detect and locate faults. Transmission system protection utilizes this approach, and commercial solutions exist for the transmission system. Using this approach in the distribution system is not straightforward and presents some challenges for implementation. This presentation will discuss the need for using wide-band models to model the traveling wave phenomenon in the distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗