Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “outdoor testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Identification and overexpression of endogenous transcription factors to enhance lipid accumulation in the biotechnologically relevant species Chlamydomonas pacifica

Sustainable low-carbon energy solutions are critical to mitigating global carbon emissions. Algae-based platforms offer potential by converting carbon dioxide into valuable products while aiding carbon sequestration. However, scaling algae cultivation faces challenges like contamination in outdoor systems. Previously, our lab evolved Chlamydomonas pacifica, an extremophile green alga, which tolerates high temperature, pH, salinity, and light, making it ideal for large-scale bioproduct production, including biodiesel. Here, we enhanced lipid accumulation in evolved C. pacifica by identifying and overexpressing key endogenous transcription factors through genome-wide in-silico analysis and in-vivo testing. These factors include Lipid Remodeling Regulator 1 (CpaLRL1), Nitrogen Response Regulator 1 (CpaNRR1), Compromised Hydrolysis of Triacylglycerols 7 (CpaCHT7), and Phosphorus Starvation Response 1 (CpaPSR1). Under nitrogen deprivation, CpaLRL1, CpaNRR1, and CpaCHT7 overexpression enhanced lipid accumulation compared to wild-type. However, CpaPSR1 increased lipid accumulation compared to wild-type in normal media and did not increase further under nitrogen deprivation, highlighting the difference in function based on media conditions. Notably, lipid analysis of CpaPSR1 under normal media conditions revealed a 2.4-fold increase in triglycerides (TAGs) compared to the wild-type, highlighting its potential for biodiesel production. This approach provides a framework for transcription factor-focused metabolic engineering in algae, advancing bioenergy and biomaterial production.

Biofuels↗

Full-scale tilt-rotor hover performance

The hover performance of three full-scale rotors was measured at the Ames Outdoor Aerodynamic Research Facility. The rotors, all designed for tilt-rotor aircraft, were the original metal blades for the XV-15 Tilt Rotor Research Aircraft, a set of composite, advanced technology blades for the XV-15, and a 0.658-scale model of the proposed V-22A Osprey (JVX) rotor. The composite advanced technology blades for the XV-15 were tested with several alternate blade root and blade tip configurations. This paper presents the performance of these three rotors, shows the effects of tip Mach number and root and tip configuration changes on rotor performance, and presents data on rotor wake velocity distributions and tip vortex geometry. Measured rotor performance is compared with theoretical predictions, and the discrepancies are discussed.

Felker, F. F.↗

Understanding PV Polymer Backsheet Degradation through X-Ray Scattering

Understanding how photovoltaic (PV) module backsheet polymers age and degrade in response to environmental stresses is important for designing polymers that can maintain their structural integrity after decades of outdoor use. X-ray scattering is a powerful technique for exploring backsheet polymer structure at the angstrom- (wide-angle, WAXS) and nanometer- (small-angle, SAXS) length-scales. We present the use of SAXS and WAXS to study pristine and aged polymer backsheets. The structural insight from these techniques can be used to compare the degradation induced by accelerated testing with the degradation seen in field-aged PV materials.

14 SOLAR ENERGY↗

Predicting discomfort from glare with pedestrian-scale lighting: A comparison of candidate models using four independent datasets

After dark, pedestrians may experience discomfort from glare caused by outdoor lighting. While several models for measuring discomfort have been proposed, there is no consensus as to which model should be used. The performances of different models were investigated using datasets from four independent studies, comparing the degree of association between model predictions and subjective ratings, and the ability of a model to distinguish between discomfort and non-discomfort situations. The models tested are those proposed by Petherbridge and Hopkinson in 1950, Schmidt-Clausen and Bindels in 1974, Bullough et al. in 2008 and Lin et al. in 2014 and 2015. They also include two quantities: direct illuminance at the eye from the glare source and average source luminance. Of the models tested, the best performance was found using either the model proposed by Bullough et al. in 2008 or by direct illuminance at the eye.

Abboushi, B.↗

Hydrogen Leak Modeling for Development of Smart Distributed Monitoring Under Unintended Releases

Hydrogen is a versatile and clean energy carrier that can be produced from various renewable sources such as wind, solar, and hydropower. Hydrogen has the potential to play a crucial role in decarbonizing industrial processes that are currently reliant on fossil fuels and provide long-duration and/or seasonal energy storage to enable electricity decarbonization. Hydrogen can also be used as a fuel for fuel cell vehicles, providing a zero-emission alternative to traditional internal combustion engines. DOE launched the Hydrogen Energy Earthshot (Hydrogen Shot) in June 2021 to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). While promising, Hydrogen is highly-flammable, and in the presence of oxygen, it can form explosive mixtures. . Therefore, understanding leak scenarios is essential to evaluate and mitigate the safety risks associated with potential hydrogen leaks. An increased understanding of leak behavior, and having tools to model leaks, can help assess how hydrogen would disperse in different environments, influencing emergency response plans and safety measures, and identify potential issues with materials and design systems that can withstand the challenges posed by hydrogen. Recently, researchers have attempted to study hydrogen leaks for development of risk management strategies. However, the focus has been on closed or semi-closed spaces like storage rooms, vehicles, garages, and fueling stations - all promising locations for future hydrogen infrastructure. In this presentation, the modeling environment extends the span of research further by modeling hydrogen leak in an outdoor, open space. We will present the key challenges with modeling hydrogen leaks in an uncontrollable environment, how they were handled, and how modeling results informed sensor selection and placement. A Hydrogen research facility at the National Renewable Energy Laboratory (NREL) was used as a case study to model hydrogen leaks. In the future, Hydrogen wide area detection methodologies will be developed and tested at this site to monitor for unintended and operational hydrogen releases. The data generated from modeling will be used to develop a predictive model to detect hydrogen leak location based on concentration measured by sensors in this open space. Furthermore, the facility was also chosen because controlled hydrogen releases can be performed. A computational fluid dynamics (CFD) based modeling approach was taken to model hydrogen leak. The full-scale hydrogen facility was modeled with a large ambient domain. The electrolyzer at the facility can produce a controlled release rate of 27 kg-H2/hr. Site-specific atmospheric and weather condition data such as wind direction, wind speed at various altitudes, and temperature were used as inputs to the model. To capture the variability of weather conditions, a subset of the weather conditions experienced during daytime hours without precipitation over the course of three months was generated; using established data clustering techniques, a total of 100 condition sets were chosen. The results show statistical distributions and ranges of hydrogen concentrations at locations throughout the domain. These distributions are compared to experimental data from a constant mass flow, controlled hydrogen release at the facility. The stochastic wind conditions of the release make direct validation difficult, therefore, statistical comparison approaches were used. Wind conditions are found to significantly impact the release behavior, including direction and concentration. Sensor selection and placement is proposed for the facility and is now based on release behavior predicted for the facility given its weather patterns; this is much more informed than without the modeling results. The methodology and analysis procedure can be translated to other facilities using modified geometries and site-specific weather conditions. Hydrogen holds great promise as a renewable energy fuel, but ensuring safety in its production, storage, and use is paramount. Studying potential leak scenarios in an open space will help develop sensors to detect hydrogen on a large spectrum of concentration and eventually build a smart distributed monitoring system.

CFD↗

Accelerated/abbreviated test methods, study 4 of task 3 (encapsulation) of the low-cost silicon solar array project

Inherent weatherability is controlled by the three weather factors common to all exposure sites: insolation, temperature, and humidity. Emphasis was focused on the transparent encapsulant portion of miniature solar cell arrays by eliminating weathering effects on the substrate and circuitry (which are also parts of the encapsulant system). The most extensive data were for yellowing, which were measured conveniently and precisely. Considerable data also were obtained on tensile strength. Changes in these two properties after outdoor exposure were predicted very well from accelerated exposure data.

Kolyer, J. M.↗

Long-term environmental effects and flight service evaluation of composite materials

Results of a NASA-Langley sponsored research program to establish the long term effects of realistic flight environments and ground based exposure on advanced composite materials are presented. The effects of moisture, ultraviolet radiation, aircraft fuels and fluids, sustained stress, and fatigue loading are reported. Residual strength and stiffness as a function of exposure time and exposure location are reported for seven different material systems after 10 years of worldwide outdoor exposure. Flight service results of over 300 composite components installed on rotorcraft and transport aircraft are included. Over 4 million total component flight hours were accumulated on various aircraft since initiation of flight service in 1973. Service performance, maintenance characteristics, and residual strength of numerous composite components installed on commercial and military aircraft are reported as a function of flight hours and years in service. Residual strength test results of graphite/epoxy spoilers with 10 years of worldwide service and over 28,000 flight hours are reported.

Dexter, H. Benson↗

How to Build a Rover: An Overview of the Mars 2020 Mission’s Vehicle System Testbed

While NASA’s Mars rover Perseverance continues to make groundbreaking achievements on the Red Planet, its twin is hard at work here on Earth. The Operational Perseverance Twin for the Integration of Mechanisms and Instruments Sent to Mars, or OPTIMISM, is the Mars 2020 Vehicle System Testbed (VSTB) rover operated by NASA Jet Propulsion Laboratory (JPL) in Pasadena, California. OPTIMISM’s home is the JPL Mars Yard; an outdoor field with red soil that simulates the terrain encountered by Perseverance. The VSTB is a full-scale engineering model of the flight rover, serving a number of functions to ensure mission operations can continue smoothly and on schedule. The VSTB possesses instrumentation, computers, mechanisms, cameras, and a Mobility subsystem that are nearly identical to its extraterrestrial twin. Its high fidelity allows the rover to be a highly effective tool to fully test system functionality and performance prior to commanding the flight rover. The early stages of building OPTIMISM began a few months prior to Perseverance departing JPL for Cape Canaveral, FL in early 2020. Electrical integration of the flight system avionics, and compatibility checkouts of the electrical ground support equipment ensured that the foundation of the electrical system was operational and in place. Next, the internal harnessing was installed and compatibility checks of the rover instrumentation and mechanisms were performed to confirm the system was prepared for full buildup. Finally, mechanical assembly of the rover chassis with its external components completed the integration of the system before it was moved to the Mars Yard for its initial phase of testing to perform verification & validation (V&V) of the Mobility subsystem requirements. By the time Perseverance landed at Jezero Crater in February 2021, the first phase of VSTB operations was underway. Surface guidance, navigation, and control (SGNC) testing for the Mobility subsystem ensured functionality and performance requirements were met for various capabilities such as visual odometry (VO), mapping, and automatic navigation (AutoNav). Subsequent integration of the robotic arm (RA) onto the VSTB enabled the V&V campaign for surface sampling operations (SSO) to commence. As the mission’s engineering operations (EO) have gotten underway, the VSTB has been utilized for an array of purposes including troubleshooting software anomalies, and performing dry-runs for first time activities (FTAs) prior to sending the commands to Perseverance. OPTIMISM will continue to serve mission critical functions as long as Perseverance is roving the Red Planet.

Rojas, Jose Trujillo↗

A Comparison of Emerging and Industry Benchmark Photovoltaic Backsheets Between Different Outdoor Locations

Recent interest within the photovoltaic (PV) module industry is largely directed toward enhanced lifetimes in the field, balanced with improved recyclability. Traditionally, fluoropolymer-based backsheets have been used, however, are difficult to recycle. Emerging polyolefin (PO)-based backsheets are more recyclable and can be formulated to be robust. Properties of different fluoropolymer- and non-fluoropolymer-based backsheet coupons and in encapsulated silicon mini modules that have been fielded in Albuquerque, NM and Cocoa, FL are reported here. Seven backsheets were examined: two novel PO's, TPT, APO, PPE, AAA, and KPf. Methods of examination include module electrical performance (I - V flash test), surface morphology (optical microscope and gloss), polymer chemical structure (FTIR), EL imaging, mechanical tensile testing, DC breakdown voltage, DSC (phase transitions), and optical performance (reflectance spectra).

industries↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 2: Particle number and size

The use of wood as a fuel for home heating is a concern from an environmental health and safety perspective as biomass combustion appliances emit high concentrations of particulate matter. Wood burning significantly contributes to wintertime particulate matter concentrations in many states in the northern United States. Of particular concern are outdoor wood-fired hydronic heaters. These devices are concerning as they tend to have very large combustion chambers and typical use patterns can result in long periods of low output, which result in an increased particulate matter emission rate relative to high heat output operating conditions. In this study, the performance of two hydronic heaters operating under different combustion conditions, including four different heat output categories approximately corresponding to categories I–IV denoted in Environmental Protection Agency Method 28 Outdoor Wood-fired Hydronic Heaters, and during start-up and reloading events were investigated. Measurements of flue gas particulate number concentration and size for particles with aerodynamic diameters between 0.006 and 10 µm were made using a dilution sampling system. The measured particle number concentration in the flue gas was between 0.71 and 420 million particles per cubic centimeter and was dependent on fuel loading and heat output. For each hydronic heater tested, the highest average particle concentration was found at the beginning of each test during the cold-start condition. Additionally, the majority of the particles had aerodynamic diameters less than 0.100 µm (particles of this size made up between 64% and 97% of all particles) and less than 1% of all particles had aerodynamic diameters greater than 1 µm for all phases. For particles in the accumulation mode, between 0.100 and 1 µm, the mean particle diameter was dependent on fuel loading and heat output.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BETO 2021 Peer Review - Cyanobacteria Photosynthetic Energy Platform (1.3.4.301)

Cyanobacteria Photosynthetic Energy Platform (WBS 1.3.4.301) The primary challenge in algal technology is low energy conversion efficiency, currently up to a few percentages from photon energy to biomass energy. Most incoming solar energy is lost in the processes of photosynthesis, through mechanisms that are not fully understood. There is large room for improvement. This project develops cyanobacteria genetic tools to improve photosynthetic efficiency and biomass productivity through manipulation of energy regulation mechanisms. Increasing algal biomass productivity by 20% translates to $2 reduction of MFSP. Genetic manipulation is an essential tool in understanding and improving algal productivity. While genetic manipulation is challenging for most algae, model cyanobacteria, with in-house mutant library and genetic engineering toolboxes, allow for rapid hypothesis testing and transfer of lessons to other cyanobacteria and eukaryotic algae. We developed Energome (energy-ome) concept to guide novel engineering strategies and unleash unused potential in photosynthesis. Energome consists of cellular energy management mechanisms. For example, we found that cyanobacteria use futile cycles around glycogen and sucrose to dissipate ATP. By genetic modification, the model cyanobacterium Synechocystis 6803 showed higher energy levels, increased photosynthetic capacity, and 20% improvement in biomass yield in simulated outdoor light conditions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carbon fiber behavior in an enclosed volume

Tests were performed to evaluate the behavior of single carbon fibers existing in an enclosed space such as a room of a building. Three general phenomena were explored: the concentration decay rate of a fiber-charged room, the degree of uniform mixing of fibers within a room, and the effects of fibers being redisseminated off deposition surfaces within a room. The results were required in understanding the ratio of total indoor fiber exposure to total outdoor fiber exposure, a quantity essential to risk analysis. Results indicate that decay rate is predictable within acceptable limits and that homogeneous mixing can always be assumed. Some factors of redissemination are identified and effects discussed.

Harvey, M. C.↗

High Intensity Lighting

Nightime illumination is an important part of round-the-clock pre-launch preparations because NASA uses TV and film cameras to monitor each step of the preliminaries and at times to identify the cause of malfunction during countdown. Generating a one billion candlepower beam visible 50 miles away, the lamps developed by Duro-Test Corporation provide daylight quality light that eliminates color distortion in film and TV coverage. The lighting system was first used at Kennedy Space Center in 1968 for the launch of Apollo 8. Modified versions are available in wide range of applications, such as the battery of spotlights with colored filters that light up Niagara Falls, as well as the lamps used in the projectors for the Smithsonian's IMAX Theatre, indoor theatres with supersized screens and outdoor projection systems.

Source record↗

Development of Algal Biomass Yield Improvements in an Integrated Process (Final Report)

This project built on the success of Global Algae Innovations Algae Biomass Yield Phase 1 project to accelerate the commercialization of algal biofuels through development of an integrated, economical, photosynthetic, open raceway system to produce algal oil. Two parallel pathways to a biofuel were investigated. In the algal crude oil pathway, highlighted in blue, the dewatered algal biomass slurry is used as a feed to hydrothermal liquefaction to produce an algae crude oil and recycle aqueous stream. In the algal lipid oil pathway, highlighted in green, the algal biomass slurry is dried, and the oil is extracted to produce an algal lipid oil biofuel intermediate and a high protein algae meal co-product. Upgrading to drop-in fuels has been demonstrated for the biofuel intermediates in both pathways. Since the algal lipid oil pathway requires lipid accumulation, the productivity is generally lower than the algal crude oil pathway, but the required productivity for economical algal biofuel production is also lower because the coproduct value is greater. The outdoor cultivation was performed at the Kauai Algae Farm. The project team has expertise across the full breadth strain development, advanced algal cultivation, open raceway contamination control, CO 2 supply, harvesting, dewatering, extraction, hydrothermal liquefaction, technoeconomic analysis and life cycle analysis: Hildebrand laboratory at Scripps Institution of Oceanography – diatom strain development. Mayfield laboratory at UCSD - green algae strain development. TSD Management Associates- CO 2 supply, algal harvesting and dewatering, and algal drying and extraction. Qualitas - large-scale test site for algal harvesting technology. Texas A&M University - algal drying and extraction technology. Pacific Northwest National Laboratory - hydrothermal liquefaction technology. GE Water and Power - membrane technology. National Renewable Energy Laboratory - algal techno-economic analysis. Phase 1 of the project resulted in tremendous productivity and pre-processing improvements in an integrated, large-scale, low-cost cultivation and pre-processing process that moved algal technology closer to economic viability for biofuels than ever before. Phase 2 accomplishments further facilitate development of a commercial algal biofuel industry by adding: several top performing strains and strain development tools including breeding; open-pond cultivation innovations that achieved a 30% improvement in overall productivity, an 83% reduction in cost, and a 95% reduction in energy use relative to conventional technology; further improvements in harvesting that led to the Zobi harvester ® as a universal, economical, low energy, commercially available microalgae harvesting solution; breakthroughs in drying and extraction including a new low energy drying process and several new low energy extraction unit operations that together with the Zobi harvester ® achieve a 90% reduction in cost and 97% reduction in energy use relative to conventional technology. These improvements are sufficient to enable economical production of algae biofuel and protein meal co-product if the process were scaled up to a commercial-scale 5,000-acre algae farm.

09 BIOMASS FUELS↗

Modeling Assessment of Residential Air-to-Water Heat Pumps Coupled with Cooling Thermal Storage

This study explored the performance and operating cost viability of air-to-water heat pumps (AWHPs) coupled with thermal energy storage (TES) in efficient new residential construction. AWHPs are an emerging technology in this country, but offer promise in terms of high efficiency, fully contained and factory charged outdoor refrigeration system, and hydronic delivery capabilities, which facilitates zoning, ducts in conditioned space, and TES integration for summer load-shifting. Although this AWHP+TES strategy is not yet mainstream, the authors feel that in ten years as decarbonization efforts proceed and TOU rates become more common, strategies such as this will be more accessible. Validated EnergyPlus simulation models were developed based on detailed monitoring data collected over several years at Pacific Gas and Electric's CVRH laboratory test homes located in Stockton, California. One of the CVRH test homes (1,962 ft 2 two-story) had been testing various AWHP systems and configurations over the past six years. The validated model was then updated with high efficiency IECC ZERH envelope and component requirements for climate zones 1-5, including ducts in conditioned space thermal distribution. Simulations were completed for the 1,962 ft 2 home in each climate zone for a minimum efficiency ASHP, an AWHP coupled with a fan coil, and an AWHP coupled with TES sized to eliminate summer on-peak compressor operation. To maintain consistency in reporting energy use estimates, all cases were run with a similar indoor thermostat control strategy to pre-cool the house below the nominal 76 degrees Fahrenheit set point prior to the on-peak period and float slightly above the set point during the peak period. The AWHP+TES configuration was controlled to alternately condition the indoor space or to charge the TES tanks prior to the beginning of the on-peak. Three composite TOU rates were developed based on existing TOU rates across the U.S. to provide differing economic scenarios to evaluate customer bill impacts throughout the summer. Two of the TOU rates had short three-hour peak periods, while the third rate had a longer seven-hour duration peak period. AWHP modeling projections were based on the observed field performance of the Chiltrix CX34 variable speed unit. Other products on the market or entering the market in the near term would likely perform differently.

25 ENERGY STORAGE↗

Energy performance analysis of smart wall system with switchable insulation and thermal storage capacity

The ever-increasing global energy demand and the issues caused by population growth and unsustainable energy resource usages have several environmental and economic impacts. The on-demand capability of dynamic wall systems with switchable insulation systems can contribute toward energy efficiency and reduced electric cost using "building-as-a-battery." In this paper, the performance of an exterior envelope system that employs a switchable insulation system is investigated. A COMSOL simulation was used to study the envelope performance under three switchable insulation locations in the wall system. The on and off switching cycle included insulating or conducting the exterior, interior, or both sides of the mass wall system. To validate the simulation work, an experimental test was conducted in climate chamber on a 4 × 8 in. wall system with identical wall components used in the COMSOL simulation. Results show a good agreement between the experiment and simulation results. The wall system with switchable insulation placed on the exterior side provided the highest interior inward heat flux when compared with the interior or split insulation. Also, an exterior switchable insulation system in addition to a thermal mass maintained a positive heat flow for more hours when the outdoor temperature was lower than the interior temperature.

Iffa, Emishaw↗

Empirical Study of the Effect of Thermal Loading on the Heating Efficiency of Variable-Speed Air Source Heat Pumps

Heating buildings with air source heat pumps (ASHPs) has the potential to save energy compared to utilizing conventional heat sources. Accurate understanding of the efficiency of ASHPs is important to maximize the energy savings. While it is well understood that, in general, ASHP efficiency decreases with decreasing outdoor temperature, it is not well understood how the ASHP efficiency changes with different levels of thermal loading, even though it is an important consideration for sizing and controlling ASHPs. The goal of this study was to create an empirical model of the ASHP efficiency as a function of two independent variables–outside temperature and level of thermal loading. Four ductless mini-split ASHPs were evaluated in a cold chamber where the temperature (representing the outdoor temperature) was varied over a wide range. For each temperature, the ASHP performance data were collected at several levels of thermal loading. The data for all four ASHPs were combined and approximated with an analytical function that can be used as a general model for the ASHP steady-state efficiency as a function of the outside temperature and level of thermal loading. To the knowledge of the authors, no such empirical model that is solely based on third-party test data has been published before. While limitations exist, the model can be used to help guide future selection and operation of ASHPs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗