Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical pumping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

A comparison of lidar and balloon-borne particle counter measurements of the stratospheric aerosol 1974-1980

The optical radar measurements considered in the present investigation are those which have been obtained routinely at Hampton, VA (37.1 deg N, 76.3 deg W) since 1974. The dustsonde measurements are those made monthly at Laramie, WY (41.2 deg N, 105 deg W). The extensive data sets acquired with these two instruments during the time period 1974-80 permit a long-term comparison of the two different measurement techniques. The balloon-borne dustsonde pumps ambient air in a well-defined stream through an illuminated chamber where individual aerosol particles scatter light into photodetectors. The optical radar system used in the studies has a ruby laser with a 48-inch Cassegrainian configured telescope mounted on a mobile platform to collect the backscattered laser light. The investigation shows that optical radar measurements, dustsonde measurements, and realistic optical models together give a very consistent picture of stratospheric aerosol behavior.

Swissler, T. J.↗

Internal CW parametric upconversion

A demonstration of CW parametric upconversion of 3.39-micron IR radiation inside a He-Ne laser's optical cavity is reported. The upconversion was achieved with the aid of a 5145-A argon laser pump and a lithium niobate crystal; the circulating power available inside the pump laser's cavity was used to maximize the efficiency of the upconversion process. Losses associated with the pump blocking filters and with the lithium niobate crystal are discussed. It is concluded that despite the high losses (approximately 12%) associated with the lithium niobate, the highest measured power conversion efficiency of 0.0038 compares favorably with the best CW external conversion efficiency reported to date.

Falk, J.↗

Raman Doppler velocimetry - A unified approach for measuring molecular flow velocity, temperature, and pressure

Molecular flow velocity (one component), translational temperature, and static pressure of N2 are measured in a supersonic wind tunnel using inverse Raman spectroscopy. For velocity, the technique employs the large Doppler shift exhibited by the molecules when the pump and probe laser beams are counterpropagating (backward scattering). A retrometer system is employed to yield an optical configuration insensitive to mechanical vibration, which has the additional advantage of simultaneously obtaining both the forward and backward scattered spectra. The forward and backward line breadths and their relative Doppler shift can be used to determine the static pressure, translational temperature, and molecular flow velocity. A demonstration of the technique was performed in a continuous airflow supersonic wind tunnel in which data were obtained under the following conditions: (1) free-stream operation at five set Mach number levels over the 2.50-4.63 range; (2) free-stream operation over a range of Reynolds number (at a fixed Mach number) to vary systematically the static pressure; and (3) operation in the flow field of a simple aerodynamic model to assess beam steering effects in traversing the attached shock layer.

Exton, R. J.↗

Test chamber for low-background IR focal plane testing

A unique and versatile vacuum chamber has been designed for JPL's IR Focal Plane Technology Group. This chamber is equipped with multiple ports for cryogen and electrical vacuum feedthroughs, pumping units, vacuum gages, sources, and detector camera heads. The design incorporates a liquid-nitrogen-cooled optical table and radiation shield for low-background IR detector testing. Focal planes can be tested at temperatures ranging from 300 K to that of liquid helium. This paper describes the design and construction of this low-background IR focal plane test chamber and discusses some of its distinctive features. An analysis of the test chamber's performance is also presented.

Staller, Craig↗

CO2 lasers and applications II; Proceedings of the Third European Congress on Optics, The Hague, Netherlands, Mar. 12-14, 1990

Recent advances in CO2 laser technology and its applications are examined. Topics discussed include the excitation of CO2 lasers by microwave discharge, a compact RF-excited 12-kW CO2 laser, a robotic laser for three-dimensional cutting and welding, three-dimensional CO2-laser material processing with gantry machine systems, and a comparison of hollow metallic waveguides and optical fibers for transmitting CO2-laser radiation. Consideration is given to an aerodynamic window with a pump cavity and a supersonic jet, cutting and welding Al using a high-repetition-rate pulsed CO2 laser, speckle reduction in CO2 heterodyne laser radar systems, high-power-laser float-zone crystal growth, melt dynamics in surface processing with laser radiation, laser hardfacing, surface melting of AlSi10Mg with CO2 laser radiation, material processing with Cu-vapor lasers, light-induced flow at a metal surface, and absorption measurements in high-power CW CO2-laser processing of materials.

Opower, Hans↗

Injection seeded, diode pumped regenerative ring Nd:YAG amplifier for spaceborne laser ranging technology development

A small, all solid state, regenerative ring amplifier designed as a prototype for space application is discussed. Novel features include dual side pumping of the Nd:YAG crystal and a triangular ring cavity design which minimizes the number of optical components and losses. The amplifier is relatively small (3 ns round trip time) even though standard optical elements are employed. The ring regeneratively amplifies a 100 ps single pulse by approximately 10(exp 5) at a repetition rate of 10 to 100 Hz. The amplifier is designed to be injection seeded with a pulsed, 100 ps laser diode at 1.06 microns, but another Nd:YAG laser system supplying higher pulse energies was employed for laboratory experiment. This system is a prototype laser oscillator for the Geoscience Laser Ranging System (GLRS) platform. Results on measurements of beam quality, astigmatism, and gain are given.

Coyle, D. Barry↗

Solid state laser systems for space application

Since the last report several things have happened to effect the research effort. In laser metrology, measurements using Michelson type interferometers with an FM modulated diode laser source have been performed. The discrete Fourier transform technique has been implemented. Problems associated with this technique as well as the overall FM scheme were identified. The accuracy of the technique is not at the level we would expect at this point. We are now investigating the effect of various types of noise on the accuracy as well as making changes to the system. One problem can be addressed by modifying the original optical layout. Our research effort was also expanded to include the assembly and testing of a diode pumped\Nd:YAG laser pumped\Ti sapphire laser for possible use in sounding rocket applications. At this stage, the diode pumped Nd:YAG laser has been assembled and made operational.

Kay, Richard B.↗

Sealing Materials for Use in Vacuum at High Temperatures

Sealing materials that can be applied and left in place in vacuum over a wide range of temperatures (especially temperatures of a few thousand degrees Celsius) have been conceived and investigated for potential utility in repairing thermal-protection tiles on the space shuttles in orbit before returning to Earth. These materials are also adaptable to numerous terrestrial applications that involve vacuum processing and/or repair of structures that must withstand high temperatures. These materials can be formulated to have mechanical handling characteristics ranging from almost freely flowing liquid-like consistency through paste-like consistency to stiff puttylike consistency, and to retain these characteristics in vacuum until heated to high curing temperatures. A sealing material of this type can be formulated to be used in any of several different ways for example, to be impregnated into a high-temperature-fabric patch, impregnated into a high-temperature-fabric gasket for sealing a patch, applied under a patch, or applied alone in the manner of putty or wallboard compound. The sealing material must be formulated to be compatible with, and adhere to, the structural material(s) to be repaired. In general, the material consists of a vacuum-compatible liquid containing one or more dissolved compound(s) and/or mixed with suspended solid particles. Depending on the intended application, the liquid can be chosen to be of a compound that can remain in place in vacuum for a time long enough to be useful, and/or to evaporate or decompose in a controlled way to leave a useful solid residue behind. The evaporation rate is determined by proper choice of vapor pressure, application of heat, and/or application of ultraviolet light or other optical radiation. The liquid chosen for the original space shuttle application is a commercial silicone vacuum-pump oil.

Pettit, Donald R.↗

Real-Time, Non-Intrusive Detection of Liquid Nitrogen in Liquid Oxygen at High Pressure and High Flow

An integrated fiber-optic Raman sensor has been designed for real-time, nonintrusive detection of liquid nitrogen in liquid oxygen (LOX) at high pressures and high flow rates in order to monitor the quality of LOX used during rocket engine ground testing. The integrated sensor employs a high-power (3-W) Melles Griot diode-pumped, solid-state (DPSS), frequency-doubled Nd:YAG 532- nm laser; a modified Raman probe that has built-in Raman signal filter optics; two high-resolution spectrometers; and photomultiplier tubes (PMTs) with selected bandpass filters to collect both N2 and O2 Raman signals. The PMT detection units are interfaced with National Instruments Lab- VIEW for fast data acquisition. Studies of sensor performance with different detection systems (i.e., spectrometer and PMT) were carried out. The concentration ratio of N2 and O2 can be inferred by comparing the intensities of the N2 and O2 Raman signals. The final system was fabricated to measure N2 and O2 gas mixtures as well as mixtures of liquid N2 and LOX

Singh, Jagdish P.↗

SLR 2000

SLR 2000 is a concept for a totally automated subcentimeter SLR system presently being studied at GSFC. If funding permits, a prototype would be installed and tested at the Goddard Geophysical and Astronomical Observatory (GCAO) in FY98 and a small number of automated stations would be fielded by the year 2000. Unlike present systems, the "SLR 2000" system is being designed to: 1) operate autonomously without the need for onsite operators; 2) present no hazards (i.e., optical, electrical, and/or chemical) to personnel in the vicinity or to overflying aircraft; and 3) have a mean time between failures (MTBF) of at least three months. It is assumed that the systems are located at "friendly" sites where some level of security is provided and where certain low level service functions (e.g. commercial power, communications, heat pump service cleaning, etc.) are available or can be contracted for locally on an as-needed basis. The main system consists of two parts - an optical head and electronics rack. The optical head contains the laser transmitter and power supply, transmit/receive switch, optical telescope, tracking angle sensor (intensified CCD camera), detector and power supply, two angular encoders, azimuth and elevation motors, and a protective dome. The optical head mounts directly to the top of a concrete pier which contains the geodetic monument and forms part of the environmental housing for the hardware and servicing personnel. It is equipped with electronic levels for leveling the mount and monitoring its stability.

Degnan, John J.↗

Demonstration of a low bandwidth 1.06-micron optical phase-locked loop for coherent homodyne communication

A type II 1.06-micron optical phase-locked loop (OPLL) for use in a coherent homodyne receiver is discussed. Diode-laser-pumped solid-state lasers are used for both the local oscillator and transmitter, because their phase noise is significantly lower than that of diode lasers. Closed-loop RMS phase noise of less than 12 mrad (0.69 deg) is achieved, and modulation-demodulation in bulk modulators at rates from 20 kHz to 20 MHz with less than 19 deg of modulation depth is demonstrated.

Day, T.↗

Optical communications systems and technology for deep-space exploration

An account is given of architectural and implementational strategies for the creation of planetary and other deep-space optical communications networks, with a view to the developmental requirements of both planetary spacecraft subsystems and an earth-vicinity reception system. Attention is given to prospective technology-development challenges. An open-loop spatial acquisition process is defined, in conjunction with a terrestrial, large-aperture/low-cost 'photon bucket' optical reception telescopic system having an integral, axially-aligned tube-bundle sunshield. An efficient diode-pumped Nd:YAG laser is envisioned as the transmitter.

Lesh, James R.↗

Multiple Stokes wavelength generation in H2, D2, and CH4 for lidar aerosol measurements

Experimental results are reported of multiple Stokes generation of a frequency-doubled Nd:YAG laser in H2, D2, and CH4 in a focusing geometry. The energies at four Stokes orders were measured as functions of pump energy and gas pressure. The characteristics of the Stokes radiation generated in these gases are compared for optical production of multiple wavelengths. The competition between Raman components is analyzed in terms of cascade Raman scattering and four-wave mixing. The results indicate the possibility of using these generation processes for atmospheric aerosol measurements by means of multiwavelength lidar systems. Also, this study distinguishes between the gases, as regards the tendency to produce several wavelengths (H2,D2) versus the preference to produce mainly first Stokes radiation (CH4).

Chu, Zhiping↗

Planar laser-induced fluorescence imaging of OH in the exhaust of a bi-propellant thruster

Planar laser-induced fluorescence imaging of the hydroxyl radical has been performed on the flow produced by the exhaust of a subscale H2/O2 fueled bi-propellant rocket engine. Measurements were made to test the feasibility of OH (0,0) and (3,0) excitation strategies by using injection seeded XeCl and KrF excimer lasers, respectively. The flow is produced with hydrogen and oxygen reacting at a combustor chamber pressure of 5 atm which then exhausts to the ambient. The hydroxyl concentration in the exhaust flow is approximately 8 percent. Fluorescence images obtained by pumping the Q1(3) transition in the (0,0) band exhibited very high signals but also showed the effect of laser beam absorption. To obtain images when pumping the P1(8) transition in the (3,0) band it was necessary to use exceptionally fast imaging optics and unacceptably high intensifier gains. The result was single-shot images which displayed a signal-to-noise ratio of order unity or less when measured on a per pixel basis.

Paul, Phillip H.↗

Fast all-optical switch

An apparatus and method wherein polarization rotation in alkali vapors or other mediums is used for all-optical switching and digital logic and where the rate of operation is proportional to the amplitude of the pump field. High rates of speed are accomplished by Rabi flopping of the atomic states using a continuously operating monochromatic atomic beam as the pump.

Shay, Thomas M.↗

Noncontacting device to indicate deflection of turbopump internal rotating parts

Phase 2 (development) which was concluded for the ultrasonic Doppler device and the light-pipe-reflectance device is reported. An ultrasonic Doppler breadboard system was assembled which accurately measured runout in the J-2 LOX pump impeller during operation. The transducer was mounted on the outside of the pump volute using a C-clamp. Vibration was measured by conducting the ultrasonic wave through the volute housing and through the fluid in the volute to the impeller surface. The impeller vibration was also measured accurately using the light-pipe probe mounted in an elastomeric-gland fitting in the pump case. A special epoxy resin developed for cryogenic applications was forced into the end of the fiber-optic probe to retain the fibers. Subsequently, the probe suffered no damage after simultaneous exposure to 2150 psi and 77 F. Preliminary flash X-radiographs were taken of the turbine wheel and the shaft-bearing-seal assembly, using a 2-megavolt X-ray unit. Reasonable resolution and contrast was obtained. A fast-neutron detector was fabricated and sensitivity was measured. The results demonstrated that the technique is feasible for integrated-time measurements requiring, perhaps, 240 revolutions to obtain sufficient exposure at 35,000 rpm. The experimental verification plans are included.

Hamilton, D. B.↗