Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical elements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

An improved large-field focusing schlieren system

The analysis and performance of a high-brightness large-field focusing schlieren system is described. The system can be used to examine complex two- and three-dimensional flows. Techniques are described to obtain focusing schlieren through distorting optical elements, to use multiple colors in a time multiplexing technique, and to use diffuse screen holography for three-dimensional photographs.

Weinstein, Leonard M.↗

Calibration and operation of a large space-based optical interferometer

The on-orbit calibration of the optics, structure, and control systems of the CSI Focus Mission Interferometer (FMI) is described. The calibration involves the estimation and propagation of both positional and rotational parameters and the propagation of both positional and rotational parameters at the nanometer/nanoradian level. It is shown that, given a nanometer class metrology system to monitor positional changes of critical optical elements, this calibration procedure should enable the FMI to perform 50 picoradian astrometry. The same Kalman filter that implements the initializing calibration of the interferometer baselines and internal pathlengths will also participate in the astrometric measurements of stellar positions.

Laskin, R. A.↗

Large field-of-view KD*P modulator

This paper describes how FOV errors have affected the polarization measurements of the NASA Marshall vector magnetograph and how a polarimeter has been modified to minimize these errors. The design of a large-FOV (LFOV) KD*P modulator is discussed. The Poincare sphere is used to visualize the function of the different optical elements that make up the LFOV modulator.

West, E. A.↗

Holographic instrumentation for monitoring crystal growth in space

Measurement requirements and candidates for measuring crystal growth in space are described, emphasizing holographic instrumentation. Existing instrumentation planned for the IML-1 Spaceflight is described along with advanced concepts for future application which incorporate diode lasers, fiber optics, and holographic optical elements. Particle image displacement velocimetry in crystal growth chambers is described.

Trolinger, James D.↗

Designing Birefringent Filters For Solid-State Lasers

Mathematical model enables design of filter assembly of birefringent plates as integral part of resonator cavity of tunable solid-state laser. Proper design treats polarization eigenstate of entire resonator as function of wavelength. Program includes software modules for variety of optical elements including Pockels cell, laser rod, quarter- and half-wave plates, Faraday rotator, and polarizers.

Monosmith, Bryan↗

SALSA - A Synthesis Array for Lunar Submillimeter Astronomy

A conceptual design is described for a lunar submillimeter wavelength interferometer called SALSA, a Synthesis Array for Lunar Submillimeter Astronomy. Its design is greatly simplified over conventional submillimeter wavelength arrays because it takes advantage of a beam waveguide to relay signals to a centrally-located receiver system. The array is optimized to synthesize images at wavelengths between 60 and 300 microns, and it has an angular resolution of 10 milliarcsecs at 60 microns. Observations in this region provide unique insights into fundamental issues in astrophysics such as star formation, but are impossible from the earth's surface because of atmospheric absorption. The baseline design for SALSA consists of twelve, 3.5-meter diameter antennas arranged in a Y-shaped configuration consisting of three 0.5-km long arms, each with four antennas distributed according to a power-law function of distance. Such a beam-waveguide approach has significant advantages, since all the high-power-consumption items (active cryogenics, correlator) are at a central location and could share a single power source. In addition, the antennas can be quite simple and maintenance is greatly reduced. The primary technology challenges for developing such an array are the coherent detectors (mixers and local oscillator sources), and ensuring the dimensional stability of the optical elements under the extreme lunar thermal environment (85-385 K).

Mahoney, M. J.↗

Surface control techniques for the segmented primary mirror in the large lunar telescope

The large lunar telescope is a proposed moon-based telescope which incorporates a sixteen-meter segmented primary mirror. An error budget is developed for the active control system of the primary mirror. A control methodology for the primary mirror is then described which utilizes piston sensors for measuring the relative piston error between adjacent segments as well as a separate sensor which measures the tilt of each segment with respect to the pointing direction of the telescope. A trade study is conducted in which the following types of tilt sensors are examined to determine their applicability to this program: stellar wavefront sensors, such as a Hartmann-Shack or a shearing interferometer; holographic optical elements; interferometers; scanning systems; and some nonoptical systems which electronically measure the relative tilt between adjacent segments. In addition, two independent methods of quantitatively verifying the performance of the telescope using either a phase retrieval algorithm or an image sharpening technique, both of which are based on the quality of a stellar image, are presented.

Gleckler, Anthony D.↗

Reflection-Type Oil-Film Skin-Friction Meter

Oil-film skin-friction meter for both flight and wind-tunnel applications uses internal reflection and is self-contained, compact unit. Contained in palm-sized housing, in which source of light, mirrors, and sensor mounted rigidly in alignment. Entire unit mounted rigidly under skin of aircraft or wind tunnel, eliminating any relative vibration between optical elements and skin of aircraft or wind tunnel. Meter primarily applicable to flight and wind-tunnel tests, also used in chemical-processing plants.

Bandyopadhyay, Promode R.↗

Injection seeded, diode pumped regenerative ring Nd:YAG amplifier for spaceborne laser ranging technology development

A small, all solid state, regenerative ring amplifier designed as a prototype for space application is discussed. Novel features include dual side pumping of the Nd:YAG crystal and a triangular ring cavity design which minimizes the number of optical components and losses. The amplifier is relatively small (3 ns round trip time) even though standard optical elements are employed. The ring regeneratively amplifies a 100 ps single pulse by approximately 10(exp 5) at a repetition rate of 10 to 100 Hz. The amplifier is designed to be injection seeded with a pulsed, 100 ps laser diode at 1.06 microns, but another Nd:YAG laser system supplying higher pulse energies was employed for laboratory experiment. This system is a prototype laser oscillator for the Geoscience Laser Ranging System (GLRS) platform. Results on measurements of beam quality, astigmatism, and gain are given.

Coyle, D. Barry↗

Harmonic oscillator states in aberration optics

The states of the three-dimensional quantum harmonic oscillator classify optical aberrations of axis-symmetric systems due to the isomorphism between the two mathematical structures. Cartesian quanta and angular momentum classifications have their corresponding aberration classifications. The operation of concatenation of optical elements introduces a new operation between harmonic oscillator states.

Wolf, Kurt Bernardo↗

Compact spaceflight solution crystal-growth system

A versatile, miniaturized, stand alone, crystal solution growth chamber design is presented which is based on fiber optics, diode lasers, and holographic optical elements in conjunction with knowledge gained from previous Spacelab work. Diagnostics instrumentation is based on a crystal growth monitor, a growth/dissolution monitor with feedback, solution diagnostics, multiple wavelength holography, and single wavelength or color Schlieren with video recording.

Trolinger, James D.↗

Solar-Stellar Irradiance Comparison Experiment 1. I - Instrument design and operation

The main objective for the Solar-Stellar Irradiance Comparison Experiment (SOLSTICE) is to accurately measure the full disk solar spectral irradiance in the ultraviolet (UV) spectral region over a long time period. To meet this objective, SOLSTICE has the unique capability of making routine observations of the UV radiation from a set of early-type stars, using the identical optical elements and detectors employed for the solar observations. The stars selected for this calibration are assumed, on the basis of stellar evolution theory, to be extremely stable in the UV spectral region. Moreover, it is the average flux from a number of stars, perhaps from as many as 25, that is assumed to be stable. The SOLSTICE 1 is on the Upper Atmosphere Research Satellite (UARS), and the overall design and operation of the instrument are discussed. The quality of the solar and stellar data is extremely high and preliminary results indicate that the technique is working well.

Rottman, Gary J.↗

Solar-Stellar Irradiance Comparison Experiment 1. II - Instrument calibrations

The science objective for the Solar-Stellar Irradiance Comparison Experiment (SOLSTICE) is to accurately measure the full disk solar spectral irradiance in the ultraviolet (UV) spectral region over a long time period. The SOLSTICE design was driven by the requirement for long-term, precise solar photometry conducted from space. The SOLSTICE 1 is on the Upper Atmosphere Research Satellite (UARS), launched in September 1991 with the possibility for a 10-year operational mission. The in-flight calibration for SOLSTICE to meet its primary objective is the routine measurements of the UV radiation from a set of early-type stars, using the identical optical elements employed for the solar observations. The extensive preflight calibrations of the instrument have yielded a precise characterization of the three SOLSTICE channels. Details of the preflight and in-flight SOLSTICE calibrations are discussed in this paper.

Woods, Thomas N.↗

Wide-Field Retroreflectors

Retroreflectors made of concentric spherical optical elements developed for use in interferometric metrological systems. Used to provide reference point on structure to be aligned precisely in two or three dimensions by use of intersecting laser beams. Acceptance angle much larger than that of cat's-eye or corner-cube retroreflector: Simultaneously reflects laser beams separated by angles as large as 180 degrees.

Page, Norman A.↗

Determination of average refractive index of spin coated DCG films for HOE fabrication

The refractive index of holographic emulsions is an important parameter needed for designing holographic optical elements (HOE's). Theoretical calculations of the accuracy required for the refractive index and thickness of emulsions needed to meet predetermined Bragg angle conditions are presented. A modified interferometric method is used to find average refractive index of the unexposed and the developed dichromated gelatin holographic films. Slanted transmission HOE's are designed considering the index and thickness variations, and used to verify the index measurement results. The Brewster angle method is used to measure surface index of the unexposed and the developed films. The differences between average index and surface index are discussed. Theoretical calculation of the effects of index variation on diffraction efficiency, and experimental results for index modulation variation caused by process changes are also presented.

Kim, T. J.↗

A phase-stepped point diffraction interferometer using liquid crystals

A new instrument, the liquid crystal point diffraction interferometer (LCPDI), has been developed for the measurement of phase objects. This instrument maintains the compact, robust design of Linnik's point diffraction interferometer (PDI) and adds to it phase stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wavefronts with high data density and with automated data reduction. The design of the LCPDI is briefly discussed. An algorithm is presented for eliminating phase measurement error caused by object beam intensity variation from frame-to-frame. The LCPDI is demonstrated by measuring the temperature distribution across a heated chamber filled with silicone oil. The measured results are compared to independently measured results and show excellent agreement with them. It is expected that this instrument will have application in the fluid sciences as a diagnostic tool, particularly in space based applications where autonomy, robustness, and compactness are desirable qualities. It should also be useful for the testing of optical elements, provided a master is available for comparison.

Mercer, Carolyn R.↗

Two-Diffraction-Order, Beam-Splitting, Imaging Spectrometer

Two-octave imaging spectrometer utilizes light of two harmonically related wavelengths diffracted to harmonically related orders at same angles, followed by separation via dichroic beam splitter before final imaging. Conceptual design of spectrometer calls for minimum number of optical elements to achieve coverage of required visible and near-infrared wavelengths in instrument of reduced size, weight, and cost.

Labaw, Clayton C.↗

Schlieren optics for leak detection

The purpose of this research was to develop an optical method of leak detection. Various modifications of schlieren optics were explored with initial emphasis on leak detection of the plumbing within the orbital maneuvering system of the space shuttle (OMS pod). The schlieren scheme envisioned for OMS pod leak detection was that of a high contrast pattern on flexible reflecting material imaged onto a negative of the same pattern. We find that the OMS pod geometry constrains the characteristic length scale of the pattern to the order of 0.001 inch. Our experiments suggest that optical modulation transfer efficiency will be very low for such patterns, which will limit the sensitivity of the technique. Optical elements which allow a negative of the scene to be reversibly recorded using light from the scene itself were explored for their potential in adaptive single-ended schlieren systems. Elements studied include photochromic glass, bacteriorhodopsin, and a transmissive liquid crystal display. The dynamics of writing and reading patterns were studied using intensity profiles from recorded images. Schlieren detection of index gradients in air was demonstrated.

Peale, Robert E.↗