Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nv”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

WHOLESCALE - Water & Hole Observations Leverage Effective Stress Calculations And Lessen Expenses (Final Technical Report 2020 - 2024)

The WHOLESCALE acronym stands for Water & Hole Observations Leverage Effective Stress Calculations and Lessen Expenses. The goal of the WHOLESCALE project is to simulate the spatial distribution and temporal evolution of stress in the geothermal system at San Emidio in Nevada, United States. To reach this goal, the WHOLESCALE team has developed a methodology to incorporate and interpret data from four methods of measurement into a multi-physics model that couples thermal, hydrological, and mechanical (T H-M) processes. The WHOLESCALE team has applied this methodology at the San Emidio geothermal field, located ~100 km north of Reno, Nevada in the northwestern Basin and Range province. The WHOLESCALE team includes 30 individuals working at two universities, two national laboratories, and one industry partner. Two master-degree students and five post-doctoral researchers have gained professional experience and earned partial financial support via the WHOLESCALE project. The WHOLESCALE team has taken advantage of the perturbations created by changes in pumping operations during planned shutdowns in 2016, 2021, and 2022 to infer temporal changes in the state of stress in the geothermal system at San Emidio, Nevada, U.S. The WHOLESCALE results support the working hypothesis that increasing pore-fluid pressure reduces the effective normal stress acting across fault zones. During normal operations, pumping in deep production wells decreases fluid pressures and thus increases the effective normal stresses on faults, reducing microseismicity. During planned shutdowns, the cessation of production increases pore-fluid pressure and reduces effective normal stress. The WHOLESCALE products generated during the 4-year period between 2020 and 2024 include: three articles published in the open-access, peer-reviewed scientific literature, two master’s theses, 20 presentations or papers at scientific conferences, and 17 data sets available on public repositories. The WHOLESCALE project has been completed in two phases that included three performance periods separated by two Go/No-go Stage Gate Reviews. Tasks were classified by data type (i.e., Geologic Structure, Borehole, Geodesy, Hydrology, Seismology, and Modeling). The first phase of the project started July 31, 2020 and included ongoing project coordination (Task 1), a project kickoff (Task 2), analysis of existing data (Task 3), development of the initial stress model & deployment design (Task 4), and Go/No-go Decision Point #1 (Task 5). Phase II began with implementing the 2022 deployment (Task 6), followed by Go/No-go Decision Point #2 (Task 7) The remainder of Phase II consisted of analyzing data collected during deployment (Task 8), calibration of the stress model on all observations (Task 9), and the Final Review (August 23, 2024) & Reporting (Task 10).

15 GEOTHERMAL ENERGY↗

Seismic DAS observations of a large underground chemical explosion in dry tuff

On 18 October 2023 a 16.3-ton TNT equivalent chemical explosion was detonated underground at the Nevada National Security Site, generating a seismic event with a magnitude of 1.7 (Meyers et al., 2024). The associated seismic wavefield was measured on a Distributed Acoustic Sensing (DAS) array with slant range distances from 27 m – 1123 m. The first arriving phase traveled at an apparent velocity of about 2640 m s -1 from 27 m to 420 m slant range and about 2470 m s -1 from 505 m to 1123 m slant range according to the first arrival moveouts on the DAS data. The first arrival from the explosion temporarily saturated the cable from a slant range of 27 m – 186 m and 0.009 s to 0.084 s post detonation. From 186 m slant range to 420 m slant range, peak strain rates of 5.6 x 10 6 nm m -1 s -1 were observed for the first arrival phase. For the first arrival from 505 m slant range to 1123 m slant range, peak strain rates reduced to 8.0 x 104 nm m -1 s -1 . A comparison of the scaled accelerations computed from DAS, the geophone pairs, and the measurements of co-located accelerometer pairs show common agreement at the scaled ranges of the single point sensors. This study adds to the body of work reporting near-source DAS observations of the seismic wavefields generated by underground chemical explosions. These results indicate that near-source DAS observations can refine interpretations of phase identification from single-point sensor observations. Phase identification could be one mechanism that contributes scatter to single point seismic measurements which would confound the performance of empirical relationships for small explosions. Removing that mechanism may therefore reduce interstation variability and increase empirical relationship performance for small explosions.

58 GEOSCIENCES↗

In-situ characterization of a background calibration line for east coast aerial measuring

Report outlines the methodology used to establish a background calibration line for AMS-East operations at Joint Base Andrews. The results provide a general isotopic characterization of the soil within the calibration line at Joint Base Andrews, and the expected terrestrial exposure rate which can be used to aerial measuring.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-Ray and Electron Spectroscopy of the CdS/(Ag,Cu)(In,Ga)Se 2 Interface With RbF Treatment

The chemical and electronic structure of the CdS/(Ag,Cu)(In,Ga)Se 2 (CdS/ACIGSe) interface for thin-film solar cells, involving an absorber with a bulk [Ag]/([Ag]+[Cu]) (AAC) ratio of 0.06, a state-of-the-art RbF post-deposition treatment (PDT), and a chemical-bath deposited CdS buffer layer, is studied. To gain a detailed and depth-resolved picture of the CdS/ACIGSe interface, synchrotron- and laboratory-based hard X-ray, soft X-ray, and UV photoelectron spectroscopy, inverse photoemission spectroscopy, and X-ray emission spectroscopy are combined. Compared to the bulk of the absorber, a Cu- and Ga-poor ACIGSe surface is found, with a slightly increased AAC ratio. Strong evidence of a Rb–In–Se species (possibly with some Ag) at the absorber surface is compiled, with a corresponding band gap of 2.79 ± 0.12 eV. This finding is in clear contrast to comparable Ag-free Cu(In,Ga)Se 2 absorbers with RbF-PDT. The Rb–In–Se surface species is not removed by the (wet-chemical) CdS deposition process, while some Se diffuses into the CdS layer and segregates at its surface. The CdS buffer layer shows a band gap of 2.48 ± 0.12 eV, and a cliff (≈ -0.4 eV) is determined in the conduction band alignment at the interface between the Rb–In–Se species and the CdS buffer.

36 MATERIALS SCIENCE↗

Evaluation of Iron‐Phosphate Glass–Ceramic Waste Form for Electrorefiner Salt Waste Simulant Dechlorinated With Phosphoric Acid

The importance of glass and glass–ceramic nuclear waste forms has been reaffirmed in recent years by the growing interest in nuclear power as a reliable energy source. Determination of processing methods for the disposal of halide-containing wastes will be essential for the advancement of nuclear technologies such as non-aqueous fuel reprocessing. Phosphate-based dechlorination and subsequent vitrification of radioactive salt waste into an iron-phosphate waste form have been identified as a potential processing scheme for electrochemical processing waste. The impact of H 3 PO 4 -based dechlorination of complex salt mixtures on the vitrification process and structure of the final iron-phosphate waste form has not yet been investigated. In this work, iron-phosphate glass–ceramics were made from simulant salt waste (48LiCl–33KCl–19NaCl mol%) dechlorinated with the H3PO4-based method. The glass-forming region was compared to that of traditionally prepared Na 2 O–Fe 2 O 3 –P 2 O 5 systems. For a candidate glass-forming composition, the processing scheme presented here was determined to favor Fe 3+ species. The O/P molar ratio was consistent for the candidate composition when dechlorinated at 400°C and 600°C in air and argon environments, indicating glass network connectivity was maintained despite variations in processing parameters. The results presented here validate processing schemes requiring iron-phosphate waste form synthesis following H 3 PO 4 -based dechlorination.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Feasibility of Metal Oxide Glasses and Polymer Membranes as Sorbents for Gaseous Oxidized Mercury

Mass spectrometry methods are currently under development by the atmospheric mercury (Hg) research community to elucidate the identity of atmospheric oxidized mercury (Hg II ) compounds. Due to high instrument detection limits, materials that can quantitatively preconcentrate atmospheric Hg II without facilitating compound-altering chemical reactions are needed to support these methods. Cation exchange membranes (CEM) and nylon membranes are currently used to preconcentrate ambient Hg II for concentration measurements and Hg II compound estimation, respectively. However, CEM and nylon membranes are poor candidates for observations by mass spectrometry methods due to release of interfering compounds upon heating; glasses do not have this problem. Here, three metal oxide glasses were explored as potential alternatives for Hg II preconcentration for future use with mass spectrometry methods: calcium phosphate (CaP), iron phosphate (FeP), and calcium aluminate (CaAl). The glasses demonstrated quantitative selective capture of HgBr 2 without capture of Hg 0 . Under ambient conditions, the CaP, FeP, and CaAl sorbed 36.4 ± 12.6% of the total HgII as the CEM. However, when Hg concentrations were normalized to surface area, CaP, FeP, and CaAl sorbed more HgBr 2 in the laboratory and ambient HgII compared to CEM. The CEM and CaP retained similar concentrations of HgBr 2 when preloaded samples were deployed in the field. Additionally, a permeation tube-based calibrator was used to load sorbents with HgBr 2 for investigation of HgII retention on CEM and thermal desorption profile changes on nylon membranes during active sampling. Nylon membranes were purchased from three vendors and used to compare HgBr 2 retention; a different HgBr 2 thermal desorption profile was achieved for each vendor’s nylon membrane.

Amides↗

Development of a broadband hard x-ray radiography platform for pulsed-power experiments

In this article, we develop and demonstrate a broadband hard x-ray radiography platform at the Zebra Pulsed Power Laboratory that integrates point-projection radiography, bremsstrahlung measurements, and hard x-ray pinhole imaging, designed to diagnose current-driven, cylindrically compressed matter. Initial laser-pulsed-power coupled experiments revealed that intense background radiation generated during 1 MA Zebra current shots overwhelmed laser-produced hard x-rays, obscuring radiographic images. Using combined spectral and spatial diagnostics, we identify energetic electrons accelerated by return currents as the dominant source of background hard x-rays, with electron energies inferred to be 3–4 MeV based on Monte Carlo simulations, and demonstrate mitigation through modifications to the radiation shielding and return-current configuration. The diagnostic platform was validated using a wire-pinch hard x-ray source, allowing radiographs of static 1-mm-diameter aluminum wires to be obtained while simultaneously measuring x-ray source spectra and spatial emission distributions within a single shot. Measured wire transmission profiles were quantitatively reconstructed using radiation transport simulations that incorporate an experimentally inferred two-temperature exponential x-ray spectrum from bremsstrahlung signal analysis and spatially distributed emission sources identified by pinhole imaging. Agreement between measured and simulated transmission profiles demonstrates the validity of the radiographic and x-ray source characterization approach, establishing this diagnostic platform as a promising tool for diagnosing magnetically driven, high-density plasmas relevant to warm dense matter and inertial fusion energy research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modification of Fractured Rock Permeability Field Using Polymer Foam to Improve Geothermal System Efficiency

The project aims at developing novel methods for blocking high-permeability pathways in geothermal reservoirs to improve heat exchange efficiency. While the project was at DRI, and now when it has been transferred to UNR, the goal of blocking high-permeability pathways is achieved through targeted injection of heat-sensitive polymer foams, particularly foamed epoxy resins, whose activation and curing are triggered by the ambient thermal field.

15 GEOTHERMAL ENERGY↗

Developments in Processing Criteria for Iron Phosphate Waste Form Design for Treating Electrorefiner Salt Wastes

This report describes work done under a Nuclear Energy University Partnership (NEUP) project that included a collaborative effort between Pacific Northwest National laboratory, University of Nevada Reno, University to Utah, and Missouri University of Science and Technology. In this project, the main goals were the following: (1) to assess H3PO4 dechlorination parameters for halide removal from salt simulants, (2) to evaluate crucible compatibility with iron phosphate glass melts, and (3) to evaluate waste form properties within a ternary system of P2O5 (added as H3PO4), Fe2O3 and fission product simulants.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗