Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Advances in solar forecasting: Computer vision with deep learning

Renewable energy forecasting is crucial for integrating variable energy sources into the grid. It allows power systems to address the intermittency of the energy supply at different spatiotemporal scales. To anticipate the future impact of cloud displacements on the energy generated by solar facilities, conventional modeling methods rely on numerical weather prediction or physical models, which have difficulties in assimilating cloud information and learning systematic biases. Augmenting computer vision with machine learning overcomes some of these limitations by fusing real-time cloud cover observations with surface measurements acquired from multiple sources. This Review summarizes recent progress in solar forecasting from multisensor Earth observations with a focus on deep learning, which provides the necessary theoretical framework to develop architectures capable of extracting relevant information from data generated by ground-level sky cameras, satellites, weather stations, and sensor networks. Overall, machine learning has the potential to significantly improve the accuracy and robustness of solar energy meteorology; however, more research is necessary to realize this potential and address its limitations.

14 SOLAR ENERGY↗

Spectroscopic performance of Low-Gain Avalanche Diodes for different types of radiation

LGADs (Low-Gain Avalanche Diodes or Detectors) are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the LGAD paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance is due to a thin substrate and the presence of a moderate signal gain. This internal gain of a few tens is enough to compensate for the reduced charge deposition in the thinner substrate and the noise of fast read-out systems. While LGADs are optimized for the detection of minimum ionizing particles for high-energy particle detectors, it is critical to study their performance for the detection of different types of particle, such as X-rays, gamma-rays, or alphas. In this paper, we evaluate the gain of three types of LGADs: two devices with different geometries and doping profiles fabricated by Brookhaven National Laboratory, and one fabricated by Hamamatsu Photonics with a different process. Since the gain in LGADs depends on the bias voltage applied to the sensor, pulse-height spectra have been acquired for bias voltages spanning from the depletion voltage up to the breakdown voltage. Finally, the signal-to-noise ratio of the generated signals and the shape of their spectra allow us to probe the underlying physics of the multiplication process.

47 OTHER INSTRUMENTATION↗

Nuclear data uncertainty propagation applied to the versatile test reactor conceptual design

We report the Versatile Test Reactor (VTR) currently under development is a 300 MWth sodium-cooled fast reactor (SFR) fueled with ternary metal alloy fuel, which aims to accelerate the testing of advanced nuclear fuels, materials, instrumentation, and sensors in high flux environments that are necessary to license the next generation of advanced reactor concepts. To support the VTR design process, uncertainties associated with the nuclear data has been propagated through the reactor core neutronics calculation to global parameters of interest, such as the core multiplication factor, kinetic parameters, and various reactivity feedback coefficients, following the sensitivity based uncertainty propagation approach. By folding the sensitivity coefficients, separately computed by the generalized perturbation theory code PERSENT and Monte Carlo code Serpent 2, with the variance-covariance matrices from COMMARA-2.0, we obtain the reaction-wise, isotope-wise, and overall uncertainties for each response of interest due to nuclear data uncertainty. With Serpent 2, the statistical error of the uncertainty is obtained by propagating the statistical error of the sensitivity coefficients through the same process using a newly developed uncertainty propagation method. From both codes, the overall top uncertainty contributors are found to be the cross section of Fe-56 elastic scattering, Na-23 elastic scattering, and U 238 inelastic scattering. The large contributions of the Fe-56 elastic scattering cross sections to global parameters are due to its relatively large relative uncertainty of 5–10% in nuclear data and the large volume of Fe-containing reflector assemblies in the fairly compact VTR core design. Both codes agreed well for the overall uncertainty estimates of all responses of interest, except the delayed neutron fraction, prompt neutron generation time, and the coolant density feedback coefficient, where Serpent 2 yielded a much larger value than PERSENT due to the large statistical error of sensitivity coefficients. The calculated uncertainties are also compared to those associated with other SFR cores. Another outcome of this study is a variance-covariance matrix of reactivity coefficients, which can be used in the subsequent uncertainty propagation to the system level to investigate the impact of identified uncertainties on system responses in the safety analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sensor and Actuator Attacks on Hierarchical Control Systems with Domain-Aware Operator Theory

Cyber-Physical Systems (CPSs) provide opportunities for cyber attacks to have physical impacts. Advanced Persistent Threats (APTs) are a subclass of cyber threats that act stealthily to avoid detection and enable long-term attacks. Here, we build on our past work in APT modelling to combine deception-based sensor bias attacks and direct actuator manipulations in attacks against a hierarchical control system. That past work used the Koopman operator to develop a data-driven, domain-aware, optimization-based attacker model. Using an expansion of this model, we compute several different attacks, including multiple simultaneous attacks, against a high-fidelity commercial building emulator and compare the impacts of those attacks to each other. One next step of interest is to construct a defender system, built on the same modelling approach, designed to detect and mitigate such attacks.

koopman operator, Cyber-Physical Security, machine↗

Test of Harmonic Coil Accuracy Using a Multi Vertex Probe

Magnets are integral components of particle accelerators, with different multipoles used to perform various beam conditioning functions, like steering and focusing. Testing accelerator magnets to ensure compliance with specification is a crucial step of fabrication. One of the most popular techniques for verifying magnetic field strength and integrity is the harmonic coil probe. Harmonic coil probes are comprised of passive loops that are rotated around the aperture of a magnet and are used to measure magnetic flux. Oftentimes the measurements of the harmonic coil probe are affected by transverse vibrations along the axis of rotation and torsional vibrations of the position closure sensor, both causing spurious harmonics. To make matters challenging, it is difficult to distinguish between the real harmonics of the magnet and the spurious harmonics during analysis. This research explores the use of a novel configuration of harmonic coil probe, Multi-Vertex Probe (MVP), to address multiple factors that affect the accuracy and repeatability of harmonic coil probe measurement. Most of the results are based on simulation data, in which artificial torsional distortions are introduced and removed with the proposed processing method. In addition to implementing torsional vibration removal in simulation, laboratory analysis regarding the source of vibrations was performed using a pre-fabricated MVP. More specifically, various mechanical conditions were used to explore the standard deviation of main harmonic’s flux amplitude. The conditions included: coupling type (rigid or soft), rotation speed, probe starting position within magnetic field, and cabling location inside the magnetic field. Along with this, the MVP’s measured noise floor in and outside a magnetic field was quantified.

Lofquist, Claire [Northern Illinois U.]↗

Cascaded Sapphire Fiber Bragg Gratings Inscribed by Femtosecond Laser for Molten Steel Studies

This research reports a distributed fiber optic high-temperature sensing system tailored for applications in the steel industry and various other sectors. Recent advancements in optical sensor technology have led to the exploration of sapphire crystal fibers as a solution for sensing in harsh environments. Utilizing a femtosecond (fs) laser, cascaded fiber Bragg gratings (FBGs) were meticulously fabricated within a multimode sapphire optical fiber. These FBGs endowed the system with distributed sensing capabilities and underwent rigorous testing under extreme temperatures, reaching up to 1800 °C. Here, the study delves into the investigation of the FBG reflection spectrum, facilitated by the development of a sophisticated multimode demodulation system, which contributed to the attainment of precise temperature measurements with a performance accuracy of 99.9%. Demonstrating exceptional thermal stability, the sapphire FBGs endured temperatures of 1600 °C for a sustained duration of 22 h. Furthermore, this article explores the application of distributed temperature sensing employing multiple sapphire FBGs, showcasing their utility in temperature measurements related to molten steel studies.

47 OTHER INSTRUMENTATION↗

Gain characterization of LGAD sensors with beta particles and 28-MeV protons

Low Gain Avalanche Diodes, also known as LGADs, are widely considered for fast-timing applications in high energy physics, nuclear physics, space science, medical imaging, and precision measurements of rare processes. Such devices are silicon-based and feature an intrinsic gain due to a p + -doped layer that allows the production of a controlled avalanche of carriers, with multiplication on the order of 10–100. This technology can provide time resolution on the order of 20–30 ps, and variants of this technology can provide precision tracking too. The characterization of LGAD performance has so far primarily been focused on the interaction of minimum ionizing particles for high energy and nuclear physics applications. This article expands the study of LGAD performance to highly-ionizing particles, such as 28-MeV protons, which are relevant for several future scientific applications, e.g. in biology and medical physics, among others. These studies were performed with a beam of 28-MeV protons from a tandem Van de Graaff accelerator at Brookhaven National Laboratory and beta particles from a ^90Sr source; these were used to characterize the response and the gain of an LGAD as a function of bias voltage and collected charge. Here, the experimental results are also compared to TCAD simulations.

47 OTHER INSTRUMENTATION↗

Sub-Doppler Cooling of a Trapped Ion in a Phase-Stable Polarization Gradient

Trapped ions provide a highly controlled platform for quantum sensors, clocks, simulators, and computers, all of which depend on cooling ions close to their motional ground state. Existing methods like Doppler, resolved sideband, and dark resonance cooling balance trade-offs between the final temperature and cooling rate. A traveling polarization gradient has been shown to cool multiple modes quickly and in parallel, but utilizing a stable polarization gradient can achieve lower ion energies, while also allowing tailorable light-matter interactions in the sub-wavelength regime. In this Letter, we demonstrate cooling of a trapped ion below the Doppler limit using a phase-stable polarization gradient created using trap-integrated photonic devices. At an axial frequency of 2⁢𝜋×1.45 MHz we achieve ⟨𝑛⟩=1.56±0.07 in 150 μ⁢s and cooling rates of ∼0.3 quanta/μ⁢s. Here, we examine ion dynamics under different polarization gradient phases, detunings, and intensities, showing reasonable agreement between experimental results and a multilevel model. Cooling is fast and power efficient, with lower average motional Fock state occupation when compared to simulated operation under the corresponding running wave configuration. Our results demonstrate a well-controlled test bed for studying the dynamics of multilevel atomic systems in a phase-stable polarization gradient.

Atom & ion cooling↗

Tardigrade: Summary (LL20-AM-sensor)

Tardigrade is an effort to create small, passive remote sensor for material detection and identification. The microbolometer based sensor design uses custom bandpass filter bands combined with tuned thermal expansion materials in a ruggedized lens housing to provide passive mechanical correction for optical changes across a wide temperature range. This requires developing computational tools to model and predict thermal performance of meta-materials composed of multiple structured base materials and void-space, along with matching and developing 3D print technology to demonstrate the housing. Current efforts in the project are in 3 areas: material design algorithm development (transitioning into full 3D material design space), multi-material additive manufacturing process exploration, and sensor/optics design and engineering.

42 ENGINEERING↗

Status Update on the Development of Transducers and Bonding Techniques for Enabling Acoustic Measurements of Damage in Microreactor Components

This report provides an overview of potential sensors and sensor-bonding techniques to enable the online acoustic interrogation of microreactor components and enhance structural health monitoring capabilities. The report focuses primarily on optical fiber–based acoustic sensors and describes initial experimental progress toward the deployment of these sensors for microreactor applications. The general approach is to monitor the resonant frequencies of microreactor components and search for evidence of structural defects that could indicate imminent failure. If properly identified, then the components could be repaired during the next reactor outage to prevent costly unplanned shutdowns. The ability to monitor the structural health of components could also reduce the need for time-consuming visual inspections and reduce staffing to improve microreactor economic viability. Increased sensor density is also one of the first steps to moving toward eventual semiautonomous operation. The expected microreactor conditions in which acoustic sensors must survive are characterized, including temperatures, neutron fluences, thermomechanical strains, and vibrational frequencies. Optical fiber–based acoustic sensors are identified as an attractive candidate for acoustic monitoring because of their high accuracy, immunity to electromagnetic interference, and resiliency in high-temperature, high-radiation environments. Optical fiber–based intrinsic sensors, such as type-II fiber-Bragg gratings and Fabry-Pérot Cavities (FPCs), are particularly attractive for a microreactor environment because of their high temperature stability, and FPCs also enable higher frequency interrogation with a lower sensitivity to radiation-induced drift. This report describes multiple interrogation systems, but the best interrogation system for a given situation will depend on the specific microreactor application, including the desired acoustic vibrational amplitudes, modes, and resonant frequencies. Initial experiments included fabricating three FPCs, tack-welding these FPCs to stainless-steel pipes or rods and performing room-temperature acoustic sensing tests to capture the vibrational frequency content. Peaks were identified in the measured frequency spectra and compared with the theoretical fundamental frequencies obtained from Euler-Bernoulli beam theory. Two of the three FPCs measured vibrational frequencies that generally matched those obtained from theory. Future work will include similar testing on pipes or other microreactor components with intentional flaws to evaluate the ability to determine changes in resonant frequencies. Finally, these tests will be repeated at high temperatures, potentially with an applied thermomechanical stress, to include environmental conditions similar to those for a microreactor application.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Microbial potentiometric sensor technology for real-time detecting and monitoring of toxic metals in aquatic matrices

Considering that toxic metals can affect metabolic processes in microorganisms adversely, it can be hypothesized that these metals in water matrices would induce a decrease in metabolic activity of the biofilm microorganisms populating the surface of a sensing electrode, which could be registered as a change in the open-circuit potential (OCP) generated by the biofilm microorganisms. The goal of this study was to test this hypothesis and demonstrate the underlying principle that microbial potentiometric sensor (MPS) technology could be used for long-term and real-time monitoring and detection of rapid changes in metal concentrations in realistic aquatic environments. To address the goal, four objective were addressed: (1) a batch reactor with three graphite-based MPS electrodes was fabricated; (2) a set of single-ion solutions and one multiple ion solution were prepared reflecting realistic concentrations of metals found in electroplating wastewaters; (3) the responses of the MPS to the simultaneous presence of multiple toxic metal ions in a single solution were measured; and (4) the changes of the MPS signals to the presence of individual metal ion solutions were examined. While the hypothesis was validated, the study also revealed that the MPS was sufficiently sensitive to not only detect, but also quantify, toxic metal ion concentrations in aqueous solutions. The coefficients of determination, which were R 2 > 0.995, and responsiveness of <1 μmol/L for some toxic metal cations, strongly support the performance of MPS technology in the echelons of expensive analytical tools capable detecting and measuring trace elements.The magnitude of the MPS response was toxic metal specific. When the molar concertation normalizes the inhibition portion of the signal area, the assessed sensitivity order was: Se>Cd>Pb>Ag>Ni> Zn. The study provides valuable information for enforcement agents, environmental professionals, and wastewater treatment operators, so toxic metal pollution and its detrimental impacts can be prevented and mitigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using Dissipative Particle Dynamics to Model Effects of Chemical Reactions Occurring within Hydrogels

Computational models that reveal the structural response of polymer gels to changing, dissolved reactive chemical species would provide useful information about dynamically evolving environments. However, it remains challenging to devise one computational approach that can capture all the interconnected chemical events and responsive structural changes involved in this multi-stage, multi-component process. Here, we augment the dissipative particle dynamics (DPD) method to simulate the reaction of a gel with diffusing, dissolved chemicals to form kinetically stable complexes, which in turn cause concentration-dependent deformation of the gel. Using this model, we also examine how the addition of new chemical stimuli and subsequent reactions cause the gel to exhibit additional concentration-dependent structural changes. Through these DPD simulations, we show that the gel forms multiple latent states (not just the “on/off”) that indicate changes in the chemical composition of the fluidic environment. Hence, the gel can actuate a range of motion within the system, not just movements corresponding to the equilibrated swollen or collapsed states. Moreover, the system can be used as a sensor, since the structure of the layer effectively indicates the presence of chemical stimuli.

36 MATERIALS SCIENCE↗

Time-Lapse Gravity Monitoring of CO2 Migration Based on Numerical Modeling of a Faulted Storage Complex

In this study, the performance of both surface and borehole time-lapse gravity monitoring to detect CO2 leakage from a carbon storage site is evaluated. Several hypothetical scenarios of CO2 migration in a leaky fault, and thief zones at different depths at the Kimberlina site (California, USA) constitute the basis of the approach. The CO2 displacement is simulated using the TOUGH2 simulator applied to a detailed geological model of the site. The gravity responses to these CO2 plumes are simulated using forward modeling with sensors at ground surface and in vertical boreholes. Results of inversion on one scenario are also presented. The surface-based gravity responses obtained for the different leakage scenarios demonstrate that leakage can be detected at the surface in all the scenarios but the time to detection is highly variable (10 to 40 years) and dependent on the detection threshold considered. Borehole measurements of the vertical component of gravity provide excellent constrains in depth when they are located in proximity of the density anomaly associated with the presence of CO2, thus discriminating multiple leaks in different thief zones. Joint inversion of surface and borehole data can bring valuable information of the occurrence of leakages and their importance by providing a reasonable estimate of mass of displaced fluids. This study demonstrates the importance of combining multiphase flow simulations with gravity modeling in order to define if and when gravity monitoring would be applicable at a given storage site.

Time-lapse gravity monitoring, leak detection, CCS↗

Cyber-Secure and Safe Operation of Solar Photovoltaic Power Distribution Systems

Solar photovoltaic (PV)-rich power distribution systems are networked Cyber-Physical Systems (CPS). These are control systems where multiple computing nodes and diverse intelligent agents interact with the physical world in real-time. However, the presence of networked components renders them vulnerable to potential cyber-attacks, cyber-intrusions, and other malicious events. This is because these systems depend on the measurements reported from their heterogeneous sensors. This makes them vulnerable to potential cyber-attacks where malicious agents can compromise the sensors or the communication networks carrying the sensor measurements. This paper proposes a novel methodology for enhancing the cyber-security and cyber-resilient post-attack safe operation of solar PV-rich power distribution systems against potential cyber-attacks through the Dynamic Watermarking (DW), using online system identification. The resiliency of the proposed technique is tested and validated with several attack scenarios on both a lab-scale 3kW grid-connected PV inverter and a Hardware-in-the-Loop (HiL) system. The proposed approach can be applied to other types of power distribution systems to enhance their cyber-secure and cyber-resilient safe operation. This paper thereby contributes to the field of cyber-security of Cyber-Physical Energy Systems (CPES).

Kim, Jaewon↗

High-bandwidth CMOS-voltage-level electro-optic modulation of 780 nm light in thin-film lithium niobate

Integrated photonics operating at visible-near-infrared (VNIR) wavelengths offer scalable platforms for advancing optical systems for addressing atomic clocks, sensors, and quantum computers. The complexity of free-space control optics causes limited addressability of atoms and ions, and this remains an impediment on scalability and cost. Networks of Mach-Zehnder interferometers can overcome challenges in addressing atoms by providing high-bandwidth electro-optic control of multiple output beams. Here, we demonstrate a VNIR Mach-Zehnder interferometer on lithium niobate on sapphire with a CMOS voltage-level compatible full-swing voltage of 4.2 V and an electro-optic bandwidth of 2.7 GHz occupying only 0.35 mm 2 . Our waveguides exhibit 1.6 dB/cm propagation loss and our microring resonators have intrinsic quality factors of 4.4 × 10 5 . This specialized platform for VNIR integrated photonics can open new avenues for addressing large arrays of qubits with high precision and negligible cross-talk.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Study on Application of Distributed Network of Sensors with List Mode for NMAC Literature Review

Nuclear material accounting and control (NMAC) for nuclear security detects, deters, and resolves questions related to unauthorized removal (i.e. theft) or misuse of nuclear material. NMAC also serves as a key insider threat mitigation measure and aids in recovery of nuclear material that is missing. Effective nuclear security depends on NMAC for timely and accurate information about nuclear material types, quantities, and locations. Bulk nuclear material processing facilities, however, present unique challenges for effective NMAC due to the presence of large quantities of material in-process and the accumulation of residual material holdup within process equipment. These holdup accumulations can obscure accurate physical inventory taking and complicate efforts to resolve NMAC irregularities at the facility level. Bulk material monitoring systems often rely on material balance calculations and indirect measurement techniques, which may mask protracted theft of smaller amounts of nuclear material. These monitoring limitations have generated increased interest in continuous monitoring technologies, including distributed non-destructive assay (NDA) sensor networks capable of providing real-time or near-real-time measurement of material movement and accumulation within bulk processing environments. Recent advancements in distributed networks of NDA radiation detectors and sensing technologies provide an opportunity to address these limitations. Although such distributed sensor networks have been implemented in select facilities for IAEA Safeguards applications, their potential for supporting NMAC functions specifically tailored to nuclear security objectives remains largely unexplored. Furthermore, emerging list-mode data acquisition technologies have reached high technology readiness levels, enabling time-correlated detection of nuclear events across multiple temporal scales. These capabilities provide enhanced opportunities for accurate holdup measurement, continuous process monitoring, and improved detection of material theft or misuse over time. The increasing global expansion of civil nuclear power and development of related bulk material processing facilities, including those supporting high-assay low-enriched uranium (HALEU) and other advanced reactor fuel fabrication, further increases the need for advanced measurement and monitoring strategies for NMAC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of blended cements and carbonation on chloride-induced corrosion propagation

Highlights: • Corrosion propagation of blended cements was investigated for 1 year. • Carbonated and non‑carbonated mortars were evaluated. • Galvanostatic pulse and ER sensors were used to monitor corrosion. • Mortar properties were correlated with corrosion rates and corrosion damage. • Relationships between mortar properties and corrosion behaviour were established. Supplementary cementitious materials are known to refine the pore structure of concrete and accelerate the carbonation progress. The combination of the two processes can have both beneficial and disadvantageous effects on corrosion, especially when chlorides are also involved. In this study the corrosion properties of multiple blended cements were evaluated in carbonated and non‑carbonated states, with chlorides introduced through cyclic ponding. The examination involved monitoring the propagation phase, determining the microstructural properties of cements, and assessing the final corrosion damage. The results showed that the steel in the blended cements initially had a relatively high corrosion activity, which later decreased compared to the OPC. This stabilisation was presumably due to the beneficial changes to the pore structure. Carbonation had a significant impact on the corrosion, with carbonated mortars revealing shallower damage over a larger surface area. This effect was more pronounced for blended cements that exhibited greater susceptibility to carbonation.

36 MATERIALS SCIENCE↗

Laser-spectroscopy testbed for impurity monitoring in liquid metal-cooled fast reactors

A significant challenge in sodium-cooled fast reactors is controlling impurities, in particular oxygen impurities, within the sodium coolant, as they can accelerate corrosion and indicate leaks. Optical methods offer the potential to rapidly detect small concentrations of both gaseous and metal impurities that accelerate corrosion, plug coolant channels, and lead to increased activation of isotopes in the coolant. We present the design and performance of an apparatus designed to enable the application of multiple optical analytical techniques, such as laser-induced breakdown spectroscopy, to detect elemental impurities in the sodium melt with high sensitivity. Here, we experimentally demonstrate the detection of characteristic sodium and oxygen spectral lines in liquid sodium, which sets the stage for the optimization of its analytical sensitivity. A robust sensor of this type integrated with the sodium cooling loop has the potential to significantly improve the safety and operational efficiency of generation IV nuclear reactors.

47 OTHER INSTRUMENTATION↗