Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “monitoring systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Plasma interactions monitoring system

The plasma environment around the space station is expected to be different from that environment which occurs naturally at these altitudes because of the unprecedented size of the space station, its orbital motion, and its high power distribution system. Although there are models which predict the environment around the station, they do not take into account changes in configuration, changes in the natural and induced environments, nor interactions between the different environments. There will be unique perturbations associated with the space station, which will vary as the space station is being developed. Even after the developed space station has been completed environmental conditions will change as the payloads are changed and as the station systems and materials undergo degradation and modification. Because the space station will be a point of many varied activities the environment will continually undergo perturbations from effluents resulting from operations of the reboost module, EVA, airlock operations, and vacuum venting. The use of the Mobile Service Center will cause disturbances which cannot, at this time, be predicted. Also, the natural environment will be affected by solar flares. In addition, the operations of attached payloads, (e.g., ASTROMAG) themselves will undoubtedly cause perturbations to the ambient environment. Finally, the natural environment will change as a result of natural perturbations such as solar flares and geomagnetic storms.

Roberts, William T.↗

Requirements for particulate monitoring system for Space Station

We recommend that a stereo camera system be utilized as a diagnostic for the particulate environment surrounding the Space Station. This system should have sufficient sensitivity to identify contaminated periods, to isolate the effects of sources and activities and to determine optical clearing times. A reasonable compromise between sensitivity and other operational constraints is recommended. Sensitivity comparable to the film camera systems should suffice, but long periods of unattended operation and remotely controlled exposure sequences are essential requirements.

Green, Byron David↗

Framework for a space shuttle main engine health monitoring system

A framework developed for a health management system (HMS) which is directed at improving the safety of operation of the Space Shuttle Main Engine (SSME) is summarized. An emphasis was placed on near term technology through requirements to use existing SSME instrumentation and to demonstrate the HMS during SSME ground tests within five years. The HMS framework was developed through an analysis of SSME failure modes, fault detection algorithms, sensor technologies, and hardware architectures. A key feature of the HMS framework design is that a clear path from the ground test system to a flight HMS was maintained. Fault detection techniques based on time series, nonlinear regression, and clustering algorithms were developed and demonstrated on data from SSME ground test failures. The fault detection algorithms exhibited 100 percent detection of faults, had an extremely low false alarm rate, and were robust to sensor loss. These algorithms were incorporated into a hierarchical decision making strategy for overall assessment of SSME health. A preliminary design for a hardware architecture capable of supporting real time operation of the HMS functions was developed. Utilizing modular, commercial off-the-shelf components produced a reliable low cost design with the flexibility to incorporate advances in algorithm and sensor technology as they become available.

Hawman, Michael W.↗

Health monitoring system for the SSME - Program overview

This paper considers the design of a health management system (HMS) program for enhancement of the safety of SSME operations during ground tests and space missions. The fault detection techniques based on time series, nonlinear regression, and clustering algorithms were developed and were demonstrated based on data from SSME ground test failures. The fault detection algorithms of the HMS system exhibited 100 percent detection of faults and an extremely low fault alarm rate, and were robust to sensor loss. A preliminary design of hardware architecture capable of supporting real-time operation of the HMS functions is described.

Hawman, Michael W.↗

Nonintrusive fast response oxygen monitoring system for high temperature flows

A new technique has been developed for nonintrusive in situ measurement of oxygen concentration, gas temperature, and flow velocity of the test media in hypersonic wind tunnels. It is based on absorption of near-infrared radiation from inexpensive GaAlAs laser diodes used in optoelectronics industry. It is designed for simultaneous measurements along multiple lines of sight accessed by fiber optics. Molecular oxygen concentration is measured from the magnitude of absorption signals; rotational gas temperature is measured from the intensity ratio of two oxygen absorption lines; and the flow velocity is measured from the Doppler shift of the absorption line positions. This report describes the results of an extensive series of tests of the prototype instrument in laboratory flames emphasizing assessment of the instruments capabilities for quantitative measurement of O2 concentration (mole fraction) and gas temperature.

Oh, Daniel B.↗

End effector monitoring system: An illustrated case of operational prototyping

Operational prototyping is introduced to help developers apply software innovations to real-world problems, to help users articulate requirements, and to help develop more usable software. Operational prototyping has been applied to an expert system development project. The expert system supports fault detection and management during grappling operations of the Space Shuttle payload bay arm. The dynamic exchanges among operational prototyping team members are illustrated in a specific prototyping session. We discuss the requirements for operational prototyping technology, types of projects for which operational prototyping is best suited and when it should be applied to those projects.

Malin, Jane T.↗

Tuning CAS Application using AIMS: An Automated Instrumentation and Monitoring System

To bring together NASA's scientists and engineers and their counterparts in industry, other government agencies, and academia working in the Computational AeroSciences (CAS) field. This workshop is part of the technology transfer plan of the High Performance Computing and Communications Program (HPCCP). Specific objectives of this Workshop are to: (1) communicate the goals and objectives of HPCCP in the area of CAS; (2) promote and disseminate CAS technology within the appropriate technical communities, including NASA, industry, academia, and other government labs; (3) help promote synergy among CAS scientists; and (4) permit feedback from peer researchers in issues pacing the CAS field in general and the HPCCP CAS program in particular.

Mehra, P.↗

Medusa Sea Floor Monitoring System

The objective of the research described in this poster presentation is to develop technologies to enable fundamental research into understanding the potential for and limits to chemolithoautotrophic life. The Medusa Isosampler (isobaric sampler), for sampling fluids eminating from deep sea hydrothermal vents and cold seep sites analogous to extraterrestrial environments, is described by the presentation. The following instruments are integrated with the isosampler, and also described: in situ flow-through chemical sensor, intrinsic fluorescent-based microbial detector, isotope ratio spectral detector.

Flynn, Michael↗

Medusa Sea Floor Monitoring System

This paper presents viewgraphs on the development of an instrument to enable fundamental research into understanding the potential for and limits to chemolithoautrophic life. The topics include: 1) Background; 2) Relevance to NASA Missions; 3) Technology Requirements; 4) Medusa System Description; 5) Medusa Components; 6) Medusa Science Capabilities; 7) Medusa Capabilities; and 8) Schedule

Flynn, Michael↗

A Global Rapid Integrated Monitoring System for Water Cycle and Water Resource Assessment (Global-RIMS)

The main focus of our work was to solidify underlying data sets, the data processing tools and the modeling environment needed to perform a series of long-term global and regional hydrological simulations leading eventually to routine hydrometeorological predictions. A water and energy budget synthesis was developed for the Mississippi River Basin (Roads et al. 2003), in order to understand better what kinds of errors exist in current hydrometeorological data sets. This study is now being extended globally with a larger number of observations and model based data sets under the new NASA NEWS program. A global comparison of a number of precipitation data sets was subsequently carried out (Fekete et al. 2004) in which it was further shown that reanalysis precipitation has substantial problems, which subsequently led us to the development of a precipitation assimilation effort (Nunes and Roads 2005). We believe that with current levels of model skill in predicting precipitation that precipitation assimilation is necessary to get the appropriate land surface forcing.

Roads, John↗

Optimal Sensor Selection for Health Monitoring Systems

Sensor data are the basis for performance and health assessment of most complex systems. Careful selection and implementation of sensors is critical to enable high fidelity system health assessment. A model-based procedure that systematically selects an optimal sensor suite for overall health assessment of a designated host system is described. This procedure, termed the Systematic Sensor Selection Strategy (S4), was developed at NASA John H. Glenn Research Center in order to enhance design phase planning and preparations for in-space propulsion health management systems (HMS). Information and capabilities required to utilize the S4 approach in support of design phase development of robust health diagnostics are outlined. A merit metric that quantifies diagnostic performance and overall risk reduction potential of individual sensor suites is introduced. The conceptual foundation for this merit metric is presented and the algorithmic organization of the S4 optimization process is described. Representative results from S4 analyses of a boost stage rocket engine previously under development as part of NASA's Next Generation Launch Technology (NGLT) program are presented.

Santi, L. Michael↗

Valve-"Health"-Monitoring System

A system that includes sensors and data acquisition, wireless data-communication, and data-processing subsystems has been developed as a means of both real-time and historical tracking of information indicative of deterioration in the mechanical integrity and performance of a highgeared ball valve or a linearly actuated valve that operates at a temperature between cryogenic and ambient.

Jensen, Scott L.↗

Development of a Portable Oxygen Monitoring System for Operations in the International Space Station Airlock

NASA is currently engaged in an activity to facilitate effective operations on the International Space Station (ISS) after the Space Shuttle retires. Currently, the Space Shuttle delivers crew and cargo to and from ISS. The Space Shuttle provides the only large scale method of hardware return from ISS to the ground. Hardware that needs to be periodically repaired, refurbished, or recalibrated must come back from ISS on the Shuttle. One example of NASA flight hardware that is used on ISS and refurbished on the ground is the Compound Specific Analyzer for Oxygen (CSA-O2). The CSA-O2 is an electrochemical sensor that is used on orbit for about 12 months (depending on Shuttle launch schedules), then returned to the ground for sensor replacement. The shuttle is scheduled to retire in 2010, and the ISS is scheduled to operate until 2016. NASA needs a hand held sensor that measures oxygen in the ISS environment and has a 5-10 year service life. After conducting a survey of oxygen sensor systems, NASA selected a Tunable Diode Laser Absorption Spectrometer (TDLAS) as the method of measurement that best addresses the needs for ISS. These systems are compact, meet ISS accuracy requirements, and because they use spectroscopic techniques, the sensors are not consumed or altered after making a measurement. TDLAS systems have service life ratings of 5-10 years, based on the lifetime of the laser. NASA is engaged in modifying a commercially available sensor, the Vaisala OMT 355, for the ISS application. The Vaisala OMT 355 requires three significant modifications to meet ISS needs. The commercial sensor uses a wall mount power supply, and the ISS sensor needs to use a rechargeable battery as its source of power. The commercial sensor has a pressure correction setpoint: the sensor can be adjusted to operate at reduced pressure conditions, but the sensor does not self correct dynamically and automatically. The ISS sensor needs to operate in the airlock, and make accurate measurements in an environment that can change from 14.7 psia to 10.2 psia in 15 minutes. The commercial sensor needs to be repackaged into a configuration that is more compact, and better suited for ISS airlock operations. NASA has recently completed a prototype of the reconfigured system. The unit has been repackaged in a way that the optical path of the spectrometer is unchanged, but the electronics has been integrated into a case measuring 10.7 X 7.2 X 3.0 inches. Two flight qualified rechargeable batteries have been integrated into system. The batteries can power the sensor for 10 hours on a single charge. A pressure sensor has been added to the system. The modified unit automatically compensates for changes in pressure, and meets 0.2% accuracy requirements for oxygen measurements in an environment with 18 to 32% oxygen across a pressure range of 10.0 to 15.0 psia.

Graf, John↗

Evaluation of a Small-Crack Monitoring System

A new system has been developed to obtain fatigue crack growth rate data from a series of images acquired during fatigue testing of specimens containing small surface cracks that initiate at highly-polished notches. The primary benefit associated with replica-based crack growth rate data methods is preserving a record of the crack configuration during the life of the specimen. Additionally, this system has the benefits of both reducing time and labor, and not requiring introduction of surface replica media into the crack. Fatigue crack growth rate data obtained using this new system are found to be in good agreement with similar results obtained from surface replicas.

Newman, John A.↗

Programs for Testing an SSME-Monitoring System

A suite of computer programs has been developed for special test equipment (STE) that is used in verification testing of the Health Management Computer Integrated Rack Assembly (HMCIRA), a ground-based system of analog and digital electronic hardware and software for "flight-like" testing for development of components of an advanced health-management system for the space shuttle main engine (SSME). The STE software enables the STE to simulate the analog input and the data flow of an SSME test firing from start to finish.

Lang, Andre↗