High-Temperature Optical Characterization of GaN-Based LEDs for Future Power Electronic Modules.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
The solar photovoltaic (PV) industry often experiences module damage during transportation. PV modules stacked horizontally and strapped on wooden pallets may develop failures impacting their efficiency (glass shattering, cracks, frame indentation, etc.), especially when modules are not packed by professionals. The appearance of failures during the shipment from one laboratory to another can be detrimental to research studies. In this study, we tested a reusable plastic pallet designed to ship modules vertically. Five technologies of commercial PV modules were shipped together from Arizona to Florida including: glass/glass bifacial modules (framed and frameless), glass/transparent backsheet bifacial modules and glass/white backsheet modules (framed). Each module technology has a different physical size. Some modules had pre-existing cell-cracks allowing for the study of cell-crack formation and propagation during shipment. Dark current-voltage (I-V), light I-V and electroluminescence characterization were performed before and after shipment. A datalogger was used to monitor shocks and ambient temperature throughout the shipment and identify when the modules were more susceptible to damage. The modules were tilted upon receipt and the pallet were damaged but with no shattered modules. Time series shock data provided by the datalogger were used to determine potential responsible events. Our results reveal a few new post-transportation cracks for some modules. Modules parameters before and after shipment are also compared regarding the module constructions and their position in the pallet.
The PASP PLUS (Photovoltaic Array Space Power Plus Diagnostics) program is a photovoltaic experiment which will be flown on the Air Force satellite APEX (Advanced Photovoltaic And Electronic Experiment). APEX will be launched with a Pegasus during the summer of 1993. There are two other small experiments on APEX but PASP+ is the largest, uses the most power, and accounts for over 90 percent of the data requirements. The orbit is elliptical with apogee and perigee of 1050 and 190 nautical miles respectively. The inclination is 70 deg. The two main objectives of PASP+ are to determine the interactions between high voltage arrays and the space plasma environment and to determine the radiation damage characteristics of several newer types of solar cells. In order to determine the interactions with the space plasma, several of the individual cell strings will be biased to voltages up to plus or minus 500 V, and leakage currents and arcing rates will be measured. The radiation degradation characteristics will be determined by the continuous monitoring of I-V data for all of the cell strings. As part of an overall testing program, the PASP+ panels and controller were put through a thermal vacuum test in order to check the thermal analysis, obtain temperature coefficients for the individual modules, and have an end-to-end test of the entire PASP+ experiment. This thermal vacuum test is described briefly and the results obtained during that testing are discussed.
Topologically protected surface current is highly promising for next-generation low-dissipation and disorder-tolerant quantum electronics and computing. Yet, electric transport from the co-existing bulk state dominates the responses of the Dirac surface state, especially at elevated temperatures relevant to technological applications. Here, we present an approach that convincingly showcases the generation, disentanglement, and precise control of enduring surface charge carriers on a topological insulator, Bi 2 Se 3 , with high bulk conductivity, all achieved at room temperature. By using pump–probe modulation spectroscopy under ultrabroadband driving tunable from 4 meV to 1.55 eV, we show the terahertz (THz) field-induced surface carriers by discovering their initial temporal responses dominant over high density trivial bulk carriers. Strikingly, the response of the induced surface carrier responses persists for more than ~5 ps and is enhanced by reducing pump photon energy. The dynamics and lifetime of the distinct surface response manifest themselves as the enhanced THz pump-induced THz transmission, which directly correlates with the transient negative THz conductivity. Increasing the THz driving field reduces the induced surface carrier lifetime and identifies, particularly, an optimal pump field of E s ~ 224 kV cm -1 for generating the dominant surface response relative to the bulk. This surface carrier dominant regime is suppressed by a joint effect of enhanced surface-bulk scattering and a more rapid saturation of surface excitation compared to the bulk that sets in above E s . The controllability of room temperature topologically surface carriers through pump photon energy offer compelling possibilities for extending this approach to other topological complex materials.
Concentrating Solar Power (CSP) generation is an attractive option for low-emission power generation; however, the high costs of thermal storage associated with concentrating solar create a large barrier for their use and adaptation into modern life. Lowering their operation costs, while maintaining high thermal storage and transfer performance is essential. Solid particle-based heat exchange systems can reduce CSP cost but are often less efficient. Efforts to increase their performance have led to use of binary size particle mixes. Presented is an optical-based thermal analysis technique used to measure near-wall thermal conductivity of particle beds essential in determining their heat exchanger efficiency. Modulated Photothermal Radiometry is used to make dynamic temperature measurements, allowing for the extraction of the most relevant thermal properties like thermal conductivity, specific heat, and effusivity. The system uses a modulated laser source causing a damped periodic heat flux, resulting in a frequency and thermal property dependent surface temperature, of which is measured using radiometry. Lock-In techniques are used to extrapolate the amplitude of the signal. Plotting the amplitude against the root angular frequency allows for effusivity measurement by ratio to a known sample. Using specific heat measurements from literature and density measurements, the thermal conductivity of the particle mixes can be calculated. The simplicity of MPTR to probe through the depth of the bed is ideal for use in CSP for dynamic thermal performance monitoring.
Utilizing variable-frequency channels, e.g., yttrium iron garnet (YIG) bandpass filters, in the intermediate frequency (IF) section of an electron cyclotron emission (ECE) radiometer facilitates flexibility in the volume viewed by the ECE channels as well as high resolution electron temperature and temperature fluctuation measurements in tokamaks. Fast modulating electron cyclotron emission (FMECE), a stand-alone IF section with eight channels, is a novel application of YIG filters for real-time electron temperature gradient and gradient scale length measurements. Key to FMECE is a simultaneous input/output data acquisition unit, as well as a modified type of YIG filters, which is capable of fast switching of their center (set) frequencies with a frequency slew rate of 600 μs/GHz. A new FMECE has been implemented and tested on the DIII-D tokamak, demonstrating its capability in real-time gradient measurements. Here, the data presented here shows that FMECE can identify flattening in the electron temperature profile; the latter can be used as a sensor for real time monitoring and control of plasma instabilities. Implementation and application are planned for the EAST tokamak.
In this part of the report, a first-principles based model is developed to predict the overpressure and temperature effects of a perforating orbital debris particle impact within a pressurized habitable module. While the effects of a perforating debris particles on crew and equipment can be severe, only a limited number of empirical studies focusing on space vehicles have been performed to date. Traditionally, crew loss or incapacitation due to a perforating impact has primarily been of interest to military organizations and as such have focused on military vehicles and systems. The module wall considered in this study is initially assumed to be a standard Whippletype dual-wall system in which the outer wall protects the module and its inhabitants by disrupting impacting particles. The model is developed in a way such that it sequentially characterizes the phenomena comprising the impact event, including the initial impact, the creation and motion of a debris cloud within the dual-wall system, the impact of the debris cloud on the inner wall, the creation and motion of the debris cloud that enters the module interior, and the effects of the debris cloud within the module on module pressure and temperature levels. This is accomplished through the application of elementary shock physics and thermodynamic theory.
A thermoelectric power generator consists of an oven box and a solar cooker/solar reflector unit. The solar reflector concentrates sunlight into heat and transfers the heat into the oven box via a heat pipe. The oven box unit is surrounded by five thermoelectric modules and is located at the bottom end of the solar reflector. When the heat is pumped into one side of the thermoelectric module and ejected from the opposite side at ambient temperatures, an electrical current is produced. Typical temperature accumulation in the solar reflector is approximately 200 C (392 F). The heat pipe then transfers heat into the oven box with a loss of about 40 percent. At the ambient temperature of about 20 C (68 F), the temperature differential is about 100 C (180 F) apart. Each thermoelectric module, generates about 6 watts of power. One oven box with five thermoelectric modules produces about 30 watts. The system provides power for unattended instruments in remote areas, such as space colonies and space vehicles, and in polar and other remote regions on Earth.
Over the past five years (June 2017-current), the vertical electric field (E z ) as well as numerous cloud, precipitation and radiation properties have been monitored at the Department of Energy-Atmospheric Radiation Measurement (DOE ARM) North Slope of Alaska (NSA) field site. Comparisons between the composite diurnal averaged fair-weather E z , and composite ceilometer derived cloud base height during the polar night, reveal a significant correlation between the parameters (r = 0.62), supporting previous studies that there is high correlation between local electric field and cloud properties. With the use of extensive instrumentation at the site, such as the Micro Pulse Lidar (MPL), Ka-band Zenith Radar (KAZR), ceilometer, SKYRAD, Precipitation Imaging Package (PIP), among others, this study provides a more comprehensive examination of the diurnal cycle of cloud and precipitation properties along with the localized fair-weather return current of the larger Global Electric Circuit (GEC) system. Comparisons between the composite diurnal averaged fair-weather E z , and cloud thickness, maximum column backscatter, and precipitation particle counts all show similar diurnal variability during the polar night, indicating that during the largest magnitude fair weather E z time periods, clouds bases tend to be higher, clouds are thicker, have a larger column backscatter, and display more precipitating particles. Furthermore, a slight diurnal variability in the polar night surface temperature was found to be highly correlated (r = 0.87) to the longwave downwelling irradiance measured by SKYRAD, indicating that the variations in the physical properties of local clouds could modulate the diurnal polar night surface temperature variability on the order of 0.5 °C/day. In conclusion, these findings emphasize the importance and global nature of the GEC system, with the global aggregate of thunderstorms and electrified clouds potentially influencing polar night cloud properties as well as diurnal wintertime polar surface temperature variation.
Size effects of mesoscale ferroelectric domains on the macroscopic dielectric and piezoelectric responses in domain-engineered bulk piezocrystals have been extensively studied for more than two decades. However, less is known about the domain size effects in ferroelectric epitaxial thin films, especially for films consisting of low-symmetry ferroelectric phases and exhibits hierarchical superdomain structures. Herein, using phase-field simulations, we systemically evaluate the effective out-of-plane dielectric and piezoelectric coefficients, κ$^{*}_{33}$ and d$^{*}_{33}$, as a function of the domain periods for two types of superdomain structures in ferroelectric K 0.5 Na 0.5 NbO 3 epitaxial thin films. In one type of the superdomain structures, we find that more than 70% increase of κ$^{*}_{33}$ and nearly 20% increase of d$^{*}_{33}$ can be achieved by tuning the domain period by a few tens of nanometers. Dissimilar behaviors are found when the domain period varies along different lateral directions, suggesting anisotropic domain size effects in thin films. By analyzing the local dielectric and piezoelectric responses from each domain variants and domain walls, we reveal that the domain size effect is governed by the variation of out-of-plane polarization inside the domains. Moreover, we also demonstrate enhanced domain size effects by modulating the misfit strains and temperature to approach the polymorphic phase boundaries, suggesting tunability of the size effect by doping and strain engineering. Furthermore, our results reveal multimodal domain size dependence of dielectric and piezoelectric responses in low-symmetry ferroelectric epitaxial thin films, implying that domain size engineering can be used to tune macroscopic properties of thin-film ferroelectrics, similar to their bulk counterparts.
Magic-size metal chalcogenide clusters of molecular size exhibit well-defined structure and unique properties that might be further expanded with the incorporation or substitution of a second metal. Here, we report the postmodification of magic-size clusters synthesized in polymer thin films via exposure to volatile metal organic precursors commonly utilized for atomic layer deposition. Exposure of In 6 S 6 (CH 3 ) 6 clusters to dimethylcadmium results in exposure-dependent incorporation of Cd 2+ , which extends the optical absorbance of the clusters into the visible spectrum. The mechanism for Cd 2+ incorporation is consistent with Cd 2+ replacement of In 3+ that includes methyl ligand removal to maintain charge neutrality. Even for clusters embedded in a polymer matrix, ligand loss leads to sintering and transformation into larger nanoscale aggregates with zinc blende-type structure. The extent of Cd incorporation can be modulated by varying the process temperature and volatile metal organic exposure as well as the choice of volatile metal organic precursor. A computational thermodynamic analysis of heteroatom incorporation for several metals and chemistries reveals that both the stability of the substituted cluster and the favorability of reaction byproducts jointly determine the favorability of cation incorporation.
Microwave heat pulse propagation experiments have demonstrated a correlation between millimeter-scale turbulence and deposition profile broadening of electron cyclotron (EC) waves on the DIII-D tokamak. In a set of discharges in DIII-D, a variation in edge density fluctuations on the mm-scale is associated with 40%–150% broader deposition profiles, expressed in terms of normalized minor radius, as compared with equilibrium ray tracing. The 1D power profile is determined from transport analysis of the electron temperature response to EC power modulation using perturbative analysis with a square wave power modulation at 20–70 Hz, producing a series of Fourier harmonics that are fit collectively to resolve transport. Fitting an integrated heat flux expressed in the Fourier basis of the modulation to diffusive, convective, and coupled transport terms in a linear model can resolve the broadened EC deposition width from the power perturbation to resolve a broadening in each case. The best fit degree of beam broadening observed scales approximately linearly with the Doppler backscattering measured fluctuation level in the steep gradient region. Quantifying the effect of edge fluctuation broadening on EC current drive power needs of future devices will require 3D full-wave codes that can be validated on the current generation of machines. These DIII-D experiments provide a quantitative measure of fluctuation effects and a dataset to benchmark full-wave simulations that can model and eventually predict nonlinear effects neglected by 1D equilibrium beam and ray tracing.
Abstract We have performed hybrid kinetic-fluid simulations of a positive column in alternating current (AC) argon discharges over a range of driving frequencies f and gas pressure p for the conditions when the spatial nonlocality of the electron energy distribution function (EEDF) is substantial. Our simulations confirmed that the most efficient conditions of plasma maintenance are observed in the dynamic regime when time modulations of mean electron energy (temperature) are substantial. The minimal values of the root mean square electric field and the electron temperature have been observed at f/p values of about 3 kHz Torr −1 in a tube of radius R = 1 cm. The ionization rate and plasma density reached maximal values under these conditions. The numerical solution of a kinetic equation allowed accounting for the kinetic effects associated with spatial and temporal nonlocality of the EEDF. Using the kinetic energy of electrons as an independent variable, we solved an anisotropic tensor diffusion equation in phase space. We clarified the role of different flux components during electron diffusion in phase space over surfaces of constant total energy. We have shown that the kinetic theory uncovers a more exciting and rich physics than the classical ambipolar diffusion (Schottky) model. Non-monotonic radial distributions of excitation rates, metastable densities, and plasma density have been observed in our simulations at pR > 6 Torr cm. The predicted off-axis plasma density peak in the dynamic regime has never been observed in experiments so far. We hope our results stimulate further experimental studies of the AC positive column. The kinetic analysis could help uncover new physics even for such a well-known plasma object as a positive column in noble gases.
Here, we report on the temperature dependence of the spatially modulated spin-polarization amplitude ΔK spin , which is a hallmark of the superconducting Fulde-Ferrell-Larkin-Ovchinnikov (FFLO) state. For that, we use 13 C nuclear magnetic resonance (NMR) spectroscopy performed on the organic conductor β" -(ET) 2 SF 5 CH 2 CF 2 SO 3 . From a comparison of our experimental results to a comprehensive modeling of the 13 C NMR spectra, we determine the evolution of ΔK spin upon condensation of the FFLO state. Further, the modeling of the spectra in the superconducting phase allows to quantify the decrease of the average spin susceptibility, stemming from the spin-singlet coupling of the superconducting electron pairs in the FFLO state of β" -(ET) 2 SF 5 CH 2 CF 2 SO 3 .
As a key feature of modular multilevel converters (MMCs), a large number of semiconductor devices are employed in the converter and distributed over a stack of submodules. Each submodule has a strict temperature limit that imposes constraints on the operating range of the converter. Different loading conditions/losses in the submodules lead to unavoidable temperature variations inside the MMC, which consequently affect the system-level performance and reliability. This paper is focused on the electrothermal analysis and design of a medium-voltage silicon carbide (SiC)-based MMC system, from submodule power semiconductors to the overall MMC system integration of multiple submodules. Loss calculations are performed to estimate the cooling requirements and aid thermal design at different levels. The performance of forced-air cooling approach is analyzed within a numerical modeling framework. Maximum temperature of the SiC power modules is predicted using numerical tools. Thermal design of the MMC cabinet with various arrangement of air inlet(s) and outlet(s) is investigated and compared from a cooling performance perspective.
We examine the hypothesis that the observed connection between the stratospheric quasi-biennial oscillation (QBO) and the strength of the Madden–Julian oscillation (MJO) is modulated by the sea surface temperature (SST)—for example, by El Niño–Southern Oscillation (ENSO). A composite analysis shows that, globally, La Niña SSTs are remarkably similar to those that occur during the easterly phase of the QBO. A maximum covariance analysis suggests that MJO power and SST are strongly linked on both the ENSO time scale and the QBO time scale. We analyze simulations with a modified configuration of version 2 of the Community Earth System Model, with a high top and fine vertical resolution. The model is able to simulate ENSO, the QBO, and the MJO. The ocean-coupled version of the model simulates the QBO, ENSO, and MJO, but does not simulate the observed QBO–MJO connection. When driven with prescribed observed SST anomalies based on composites for QBO east and QBO west (QBOE and QBOW), however, the same atmospheric model produces a modest enhancement of MJO power during QBOE relative to QBOW, as observed. We explore the possibility that the SST anomalies are forced by the QBO itself. Indeed, composite Hovmöller diagrams based on observations show the propagation of QBO zonal wind anomalies all the way from the upper stratosphere to the surface. Also, subsurface ocean temperature composites reveal a similarity between the western Pacific and Indian Ocean subsurface signal between La Niña and QBOE.
The purpose of this study is to experimentally investigate the thermal performance of an innovative thermal energy storage (TES) system that combines the advantages of the phase-change material (PCM)/graphite foam latent heat TES medium developed at Argonne National Laboratory (Argonne) and the internally supported plate-fin (ISPE) cell architecture heat transfer fluid (HTF) flow channels developed at Brayton Energy (Brayton). Several essential tasks were accomplished: (1) Thermal property characterization. Thermal properties of the graphite foam were characterized, providing necessary data for experimental result analysis and numerical simulation. (2) Design and optimization of lab-scale test module. Based on Brayton’s full-scale heat exchanger (HX)-TES system, the experimental test module was designed, optimized, and fabricated. (3) Thermal performance testing and data analysis. Five cycle tests were successfully conducted—including one with approximately 3.5 psig of pressure applied to the diaphragms—to investigate the thermal performance of the experimental test module for charging and discharging. Temperature profiles were generated for each charging test and discharging test as a function of time. The temperature profiles clearly show three TES stages: sensible heat (temperature increase), latent heat (melting), and sensible heat (temperature increase) for the charging process. Similarly, the temperature profiles clearly show three thermal energy release stages: sensible heat (temperature decrease), latent heat (solidification), and sensible heat (temperature decrease). Melting and solidification of the PCM generally occurred in relatively narrow temperature ranges, indicated by the flattened temperature regions in the temperature profiles. These phase changes ranged approximately 3°C for melting and 3.5°C for solidification. The charging and discharging temperature profiles were similar for similar experimental parameter tests whether or not pressure was applied to the diaphragm to eliminate the gap between the HX surface and the TES subsystem. This indicates that the effect of a small gap between the HX surface and the TES subsystem is insignificant for charging and discharging. (4) Comparison of experimental data and simulation results. We compared the experimental data to the numerical simulation results. Numerical simulations were conducted by using the ANSYS FLUENT 2019 R3 commercial computational fluid dynamics software. The predicted phase-change times agreed reasonably well with those from the experimental data. In most cases, the estimated time differences between the relative phase changes were within 16%. The predicted start and end times for the charging process agreed well with those from the experimental data. However, the simulation results showed earlier start and end times than the experimental data for the discharging process. Overall, the experimental data and its comparison with the simulation predictions verified the technical viability of the integrated ISPF HX-PCM/graphite foam latent-heat TES system.
This presentation will first describe the design of a novel modular residential cold-climate heat pump for both space conditioning and water heating that can be coupled with thermal energy storage (TES) to maximize system efficiency and load flexibility. Among some of the novel operating modes of the proposed design include: 1) simultaneous outdoor coil defrost while still providing space heating or water heating; 2) simultaneous water heating and space cooling 3) using the TES as the heat source during cold climate operation to improve efficiency and 4) compressorless charging of the TES module during days with high temperature swings between night and day. Then, initial simulation results will be presented describing system performance in key operating modes in climate region 5.