Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microwave sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

ORION: Microwave water vapor radiometer subsystem design

Electrical path delay caused by atmospheric water vapor may be a limiting error source for geodetic measurements made with VLBI. Direct measurement of atmospheric water vapor is necessary to obtain path delay correction required by the ORION project. A dual channel water vapor radiometer is described which operates at frequencies near the 22 GHz water vapor line and is capable of collecting data that permits calculation of path delay within 2 cm accuracy.

Mckinney, R. P.↗

TOPEX microwave radiometer system calibration - Refining the SMMR heritage

A modified version of the Scanning multichannel Microwave Radiometer (SMMR) will be used for wet tropospheric path-delay corrections to the TOPEX/POSEIDON radar altimeter measurements. A number of the sources of calibration problems encountered by SMMR onboard the Seasat and Nimbus-7 platforms have been identified, and appropriate corrections have been attempted. Calibration hardware corrections include a more representative modeling of the microwave losses and reflections, and a reduction in the thermal gradients expected across this hardware through the use of radomes and sun shades and the choice of pertinent orbit parameters. Antenna calibration corrections include a postlaunch fine tuning of the antenna pattern correction algorithm to accommodate small errors in the prelaunch antenna pattern measurements. This is accomplished by overpasses of ground-based, upward-looking water vapor radiometers. An absolute calibration accuracy of 1.0 K or less is anticipated.

Ruf, Christopher S.↗

Ultrahigh-energy neutrino astronomy

High-energy cosmic-ray interactions can produce neutrinos. The neutrino fluxes are calculated over a range of energies. The sources considered (and their ranges of importance) are cosmic-ray interactions in earth's atmosphere (neutrino energies less than 10,000 GeV), cosmic-ray interactions with ambient hydrogen in galaxies (neutrino energies between 10,000 and 1 million GeV), regions of cosmic-ray acceleration - e.g., pulsars - and cosmic-ray interactions with the microwave background radiation (neutrino energies greater than 100 million GeV). In addition, estimates of the flux from compact sources, such as active galaxies, are made. These flux levels, calculated conservatively, may be high enough for practical detection with a 1-cu km seawater detector; i.e., count rates greater than 1 per day. Such observations would provide information mainly about high-energy physics, but also (over long times) about cosmic-ray spectra, composition, and acceleration, as well as supernova and galactic-nucleus explosions.

Margolis, S. H.↗

Ion-implanted high microwave power indium phosphide transistors

Encapsulated rapid thermal annealing (RTA) has been used in the fabrication of InP power MISFETs with ion-implanted source, drain, and active-channel regions. The MISFETs had a gate length of 1.4 microns. Six to ten gate fingers per device, with individual gate finger widths of 100 or 125 microns, were used to make MISFETs with total gate widths of 0.75, 0.8, or 1 mm. The source and drain contact regions and the channel region of the MISFETs were fabricated using Si implants in InP at energies from 60 to 360 keV with doses of (1-560) x 10 to the 12th/sq cm. The implants were activated using RTA at 700 C for 30 sec in N2 or H2 ambients using an Si3N4 encapsulant. The high-power high-efficiency MISFETs were characterized at 9.7 GHz, and the output microwave power density for the RTA conditions used was as high as 2.4 W/mm. For a 1-W input at 9.7 GHz gains up to 3.7 dB were observed, with an associated power-added efficiency of 29 percent and output power density 70 percent greater than that of GaAs MESFETs.

Biedenbender, Michael D.↗

Microwave imaging of a solar limb flare - Comparison of spectra and spatial geometry with hard X-rays

A solar limb flare was mapped using the Very Large Array (VLA) together with hard X-ray (HXR) spectral and spatial observations of the Solar Maximum Mission satellite. Microwave flux records from 2.8 to 19.6 GHz were instrumental in determining the burst spectrum, which has a maximum at 10 GHz. The flux spectrum and area of the burst sources were used to determine the number of electrons producing gyrosynchrotron emission, magnetic field strength, and the energy distribution of gyrosynchrotron-emitting electrons. Applying the thick target model to the HXR spectrum, the number of high energy electrons responsible for the X-ray bursts was found to be 10 to the 36th, and the electron energy distribution was approximately E exp -5, significantly different from the parameters derived from the microwave observations. The HXR imaging observations exhibit some similiarities in size and structure o the first two burst sources mapped with the VLA. However, during the initial burst, the HXR source was single and lower in the corona than the double 6 cm source. The observations are explained in terms of a single loop with an isotropic high-energy electron distribution which produced the microwaves, and a larger beamed component which produced the HXR at the feet of the loop.

Schmahl, E. J.↗

Radiometric Calibration Techniques for Signal-of-Opportunity Reflectometers

Bi-static reflection measurements utilizing global navigation satellite service (GNSS) or other signals of opportunity (SoOp) can be used to sense ocean and terrestrial surface properties. End-to-end calibration of GNSS-R has been performed using well-characterized reflection surface (e.g., water), direct path antenna, and receiver gain characterization. We propose an augmented approach using on-board receiver electronics for radiometric calibration of SoOp reflectometers utilizing direct and reflected signal receiving antennas. The method calibrates receiver and correlator gains and offsets utilizing a reference switch and common noise source. On-board electronic calibration sources, such as reference switches, noise diodes and loop-back circuits, have shown great utility in stabilizing total power and correlation microwave radiometer and scatterometer receiver electronics in L-band spaceborne instruments. Application to SoOp instruments is likely to bring several benefits. For example, application to provide short and long time scale calibration stability of the direct path channel, especially in low signal-to-noise ratio configurations, is directly analogous to the microwave radiometer problem. The direct path channel is analogous to the loopback path in a scatterometer to provide a reference of the transmitted power, although the receiver is independent from the reflected path channel. Thus, a common noise source can be used to measure the gain ratio of the two paths. Using these techniques long-term (days to weeks) calibration stability of spaceborne L-band scatterometer and radiometer has been achieved better than 0.1. Similar long-term stability would likely be needed for a spaceborne reflectometer mission to measure terrestrial properties such as soil moisture.

calibrating↗

Control Design for Inhomogeneous-Broadening Compensation in Single-Photon Transducers

We report a transducer of single photons between microwave and optical frequencies can be used to realize quantum communication over optical fiber links between distant superconducting quantum computers. A promising scalable approach to constructing such a transducer is to use ensembles of quantum emitters interacting simultaneously with electromagnetic fields at optical and microwave frequencies. However, inhomogeneous broadening in the transition frequencies of the emitters can be detrimental to this collective action. In this paper, we utilize a gradient-based optimization strategy to design the temporal shape of the laser field driving the transduction system to mitigate the effects of inhomogeneous broadening. We study the improvement of transduction efficiencies as a function of inhomogeneous broadening in different single-emitter cooperativity regimes and correlate it with a restoration of super-radiance effects in the emitter ensembles. Furthermore, to assess the optimality of our pulse designs, we provide certifiable bounds on the design problem and compare them to the achieved performance.

74 ATOMIC AND MOLECULAR PHYSICS↗

Development program on a Spindt cold-cathode electron gun

A thin film field emission cathode (TFFEC) array and a cold cathode electron gun based on the emitter were developed. A microwave tube gun that uses the thin film field emission cathode as an electron source is produced. State-of-the-art cathodes were fabricated and tested. The tip-packing density of the arrays were increased thereby increasing the cathode's current density capability. The TFFEC is based on the well known field emission effect and was conceived to exploit the advantages of that phenomenon while minimizing the difficulties associated with conventional field emission structures, e.g. limited life and high voltage requirements. Field emission follows the Fowler-Nordheim equation.

Spindt, C. A.↗

The universe between z = 10 and and z = 1000 - Spectral constraints on reheating

The possible thermal histories of the universe during the epoch z = 10-1000 are studied. Expressions for the fractional ionization and electron temperature are given in the case of homogeneous heating as a function of the parameters of arbitrary ionizing sources. It is shown that present and future limits on spectral distortions to the microwave background radiation do not provide very restrictive constraints on possible thermal histories of the universe. If H(0) = 50 km/s Mpc, the universe could have been completely ionized throughout its history with no observable spectral effects even if Omega = 1 and the universe is entirely made of baryons. Heating by cosmic rays and very massive stars is briefly discussed.

Stebbins, A.↗

Propellant combustion response to oscillatory radiant heat flux

An introductory progress report is given on a research project to use the microwave Doppler velocimeter technique to measure the combustion response to an oscillating thermal radiation source (laser). The objective is to relate the measured burning rate response to the thermal radiation to an equivalent oscillation in pressure using existing thermal combustion theory. The test system is described, and the results of an initial test series on the composite propellant A-13 are presented.

Strand, L. D.↗

Solid propellant combustion response to oscillatory radiant heat flux

A progress report is given on a research project to use the microwave Doppler velocimeter technique to measure the combustion response to an oscillating thermal radiation source (CO2 laser). The test technique and supporting analyses are described, and the results are presented for an initial test series on the nonmetallized, composite propellant, Naval Weapons Center formulation A-13. It is concluded that in-depth transmission of radiant heat flux is not a factor at the CO2 laser wave length.

Strand, L. D.↗

Temperature Compensated Sapphire Resonator for Ultrastable Oscillator Operating at Temperatures Near 77 Deg Kelvin

A sapphire resonator for an ultrastable oscillator capable of substantial performance improvements over the best available crystal quartz oscillators in a compact cryogenic package is based on a compensation mechanism enabled by the difference between copper and sapphire thermal expansion coefficients for so tuning the resonator as to cancel the temperature variation of the sapphire's dielectric constant. The sapphire resonator consists of a sapphire ring separated into two parts with webs on the outer end of each to form two re-entrant parts which are separated by a copper post. The re-entrant parts are bonded to the post by indium solder for good thermal conductivity between parts of that subassembly which is supported on the base plate of a closed copper cylinder (rf shielding casing) by a thin stainless steel cylinder. A unit for temperature control is placed in the stainless steel cylinder and is connected to the subassembly of re-entrant parts and copper post by a layer of indium for good thermal conduction. In normal use, the rf shielding casing is placed in a vacuum tank which is in turn placed in a thermos flask of liquid nitrogen. The temperature regulator is controlled from outside the thermos flask to a temperature in a range of about 40K to 150K, such as 87K for the WGH-811, mode of resonance in response to microwave energy inserted into the rf shielding casing through a port from an outside source.

Dick, G. John↗

Technique for Radiometer and Antenna Array Calibration with Two Antenna Noise Diodes

This paper presents a new technique to calibrate a microwave radiometer and phased array antenna system. This calibration technique uses a radiated noise source in addition to an injected noise sources for calibration. The plane of reference for this calibration technique is the face of the antenna and therefore can effectively calibration the gain fluctuations in the active phased array antennas. This paper gives the mathematical formulation for the technique and discusses the improvements brought by the method over the existing calibration techniques.

Srinivasan, Karthik↗

Precise 2D electric field density simulations for superconducting quantum devices

Dielectric loss due to two-level systems is a limiting factor for superconducting qubit relaxation times. These losses arise mostly from nanometer-scale interfacial defect regions in superconducting devices with planar dimensions of microns to millimeters, thus making it resource intensive to accurately simulate the electric field density in these regions with traditional electromagnetic solvers. In this work, we demonstrate a fast boundary integral equation solver that allows precise simulation of electric field density in these thin regions, showing a speedup of around two orders of magnitude over traditional solvers, with relative errors around $10^{-7}$ for a ten-minute solution runtime. By computing participation ratios through Green's first identity without squaring the electric field, our approach is less susceptible to the field singularities near conductor corners. We apply this solver to a basic untrenched coplanar waveguide cross-section, showing that the common assumption of participation ratio linearity with dielectric constant holds well for some interfaces and not others; in particular, while the metal-air (MA) top and corner follow this linear relationship strongly, the MA sidewall does not. We then compare isotropic and anisotropic etching, showing that the MA sidewall and the metal-air-substrate triple junction are the most strongly affected. We are currently leveraging this solver to explore geometries that will uniquely isolate the participation ratios of the different dielectrics. Finally, we are working to combine this solver framework with a full 3D microwave solver to accurately calculate participation ratios for the thin dielectrics that are known sources of loss in superconducting qubits.

Gimbutas, Z. [NIST, Boulder] (ORCID:00000003320982↗

Microwave–photonic low-coherence interferometry for dark zone free distributed optical fiber sensing

A microwave–photonic low-coherence interferometry (MPLCI) system is proposed for fully distributed optical fiber sensing. Assisted by an unbalanced Michelson interferometer, a low-coherence laser source is used to interrogate cascaded Fabry–Perot interferometers along with an optical fiber for a dark zone free (or spatially continuous) distributed measurement. Here, by combining the advantages of microwaves and photonics, the MPLCI system can synergistically achieve high sensitivity and high spatial resolution. Our tests have confirmed a strain resolution of 95 nε at the spatial resolution of 10 cm.

42 ENGINEERING↗

Probing thick vegetation canopies with a field microwave scatterometer

with a narrow-beam field microwave scatterometer having a variable slant range and a small slant-range resolution, investigators can estimate the distribution of backscattering sources in a medium as a function of slant range. From this, they can calculate the backscattering coefficient. With less confidence, they can estimate the volume extinction coefficient, the volume density of backscattering cross sections, the transmittance, and the backscattering coefficient of a semiinfinite medium with the same volumetric microwave properties. These parameters allow one to understand the interactions of microwaves with media such as vegetation canopies with their substrates.

Paris, J. F.↗

Vibration Method for Tracking the Resonant Mode and Impedance of a Microwave Cavity

A vibration technique his been developed to continuously maintain mode resonance and impedance much between a constant frequency magnetron source and resonant cavity. This method uses a vibrating metal rod to modulate the volume of the cavity in a manner equivalent to modulating an adjustable plunger. A similar vibrating metal rod attached to a stub tuner modulates the waveguide volume between the source and cavity. A phase sensitive detection scheme determines the optimum position of the adjustable plunger and stub turner during processing. The improved power transfer during the heating of a 99.8% pure alumina rod was demonstrated using this new technique. Temperature-time and reflected power-time heating curves are presented for the cases of no tracking, impedance tracker only, mode tracker only and simultaneous impedance and mode tracking. Controlled internal melting of an alumina rod near 2000 C using both tracking units was also demonstrated.

Barmatz, M.↗

The Material Plasma Exposure eXperiment: Mission and conceptual design

Mastering Plasma Material Interactions (PMI) is key for obtaining a high performance, high duty-cycle and safe operating fusion reactor. Numerous gaps exist in PMI which have to be addressed before a reactor can be built. In particular the lack of data at high ion fluence, fusion reactor divertor relevant plasma conditions and neutron displacement damage requires new experimental devices to be able to develop plasma facing materials and components. This has been recognized in the community and the U.S. fusion program is addressing this need with a new linear plasma device—the Material Plasma Exposure eXperiment (MPEX). MPEX will be a superconducting linear plasma device with magnetic fields of up to 2.5 T. The plasma source is a high-power helicon source (200 kW, 13.56 MHz). The electrons will be heated via Electron Bernstein Waves with microwaves using multiple 70 GHz gyrotrons (up to 600 kW in total). Ions will be heated via ion cyclotron heating in the so-called “magnetic beach heating” scheme in the frequency range of 6–9 MHz (up to 400 kW in total). An overview of the conceptual design and the project/design requirements is given in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗