Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “meter, test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Membrane Vibration Tests Using Surface-Bonded Piezoelectric Patch Actuation

This paper describes the status of on-going work at the NASA Langley Research Center to measure the dynamics of thin membranes. The test article is a one-meter square pre-tensioned Kapton membrane that incorporates small surface-bonded piezoelectric patches strategically positioned to excite many modes. It is shown that PVDF (polyvinylidene fluoride) and MFC (macro fiber composite) piezoelectric patch actuators provide adequate excitation energy to obtain modal frequencies and mode shapes. Results from modal tests performed on the membrane using piezoelectric patches of different sizes and positions are discussed.

Gasper, James L.↗

Design and test of a 2m x 4m DART system

A 2 meter by 4 meter DART (dual anamorphic reflector telescope) system has been designed and fabricated using thin stretched mesh reflectors. This report documents the structural configuration, test preparation, test results, and analysis correlation.

TPF Terrestrial Planet Finder life detection extra↗

Experimental Investigation of a Phase Change Material Charged Serpentine Heat Exchanger with Louvered Fins

Phase change material heat exchangers (PCM-HX) can be used as a latent heat thermal energy storage (LHTES) component in heat pump applications to further enhance the efficiency of a heat pump as well as to yield financial savings by peak-load shifting. In this paper, a low-cost commercially available aluminum serpentine heat exchanger with louvered fins was experimentally investigated to check its thermal performance as a PCM-HX. A transparent rectangular box fabricated from acrylic plates served as a PCM container. Two cameras were used to capture the phase change process of the PCM on the front and top sides of the container during the experiment. A total of 88 installed temperature sensors throughout the test setup and a mass flow meter enabled a quantitative analysis of the PCM-HX as well. The energy balance deviation between the estimated theoretical and experimentally calculated PCM storage was ±14% considering the often-neglected heat loss and thermal mass of the PCM-HX. PCM temperature profiles, charge and discharge rates, and energy densities under different test conditions were also investigated.

42 ENGINEERING↗

Acoustic performance evaluation of an advanced UH-1 helicopter main rotor system

An experimental investigation of the high-speed impulsive noise characteristics of an advanced main rotor system for the UH-1 helicopter has been conducted. Models of both the advanced main rotor system and the UH-1 main rotor system were tested at one-quarter scale in the Langley 4- by 7-meter (V/STOL) Tunnel using the General Rotor Model System (GRMS). Tests were conducted over a range of simulated flight and descent velocities. The tunnel was operated in the open-throat configuration with acoustic treatment to improve the acoustic characteristics of the test chamber. In-plane acoustic measurements of the high-speed impulsive noise demonstrated a 7 to 8 dB reduction in noise generation is available by using the advanced rotor system on the UH-1 helicopter.

Hoad, D. R.↗

Performance Testing of TRL4-6 LISA Laser System

The Laser Interferometer Space Antenna (LISA) is an ESA-led future mission to measure gravitational waves from astronomical sources in space. LISA has been adopted as a formal mission by ESA in January 2024, and is expected to become a formal project at NASA within 2024. The laser system (LS), which includes four laser heads (LH) each containing a laser optical module (LOM) and laser electronics module (LEM), a frequency reference system (FRS, optical frequency reference) and four power monitor detectors (PMON), is one of the three U.S. contributions to LISA from NASA. The Lasers and Electro-Optics Branch at NASA GSFC has been developing and managing the design of the LISA LS. Currently, the TRL (technology readiness level) of the NASA LISA laser system is transitioning from 4 to 6. TRL 4/5 LISA LOM was sent to ESA in early 2023 and has undergone optical performance testing. [1] By late summer of 2024, NASA plans to deliver the TRL 6 LOM to ESA for performance evaluation. Since the delivery of the TRL4/5 LOM to ESA, we have taken steps to advance the TRL of the overall LS and have also started end-to-end system level testing involving other subsystems. They include 1) optical performance test of TRL6 LOM and TRL 5 LEM under thermal cycling, 2) end-to-end test of the laser head (LH) and the GSE (ground support equipment) FRS, driven by TRL 4 FRS electronics (FRS-E) provided by Ball Aerospace, 3) end-to-end test of the laser head (LH) with the GSE phase meter system (PMS) provided by Albert Einstein Institute, and 4) optical performance test of the LH with the PMON subsystem developed by NASA. The FRS, PMS, and PMON provide necessary frequency stability, relative phase stability between lasers, and output power stability, respectively. Since they are all vital for the sensitive laser interferometry performed in LISA, it is necessary to perform these system level testing by combining the LH and other subsystems, and to prove the optical performance at an early stage during the LS development. Our recent work has successfully demonstrated the intra-connectivity of the LS, as well as critical external interface with the PMS to meet the LISA’s performance requirements. In this talk, we will report on the latest status of the LH testing and system level test. We will also discuss the paths to bring each subsystem to TRL6+ and plans for future system level testing.

LISA↗

Numerical Simulations of Instabilities in Single-Hole Office Elements

An orifice element is commonly used in liquid rocket engine test facilities either as a flow metering device, a damper for acoustic resonance or to provide a large reduction in pressure over a very small distance in the piping system. While the orifice as a device is largely effective in stepping down pressure, it is also susceptible to a wake-vortex type instability that generates pressure fluctuations that propagate downstream and interact with other elements of the test facility resulting in structural vibrations. Furthermore in piping systems an unstable feedback loop can exist between the vortex shedding and acoustic perturbations from upstream components resulting in an amplification of the modes convecting downstream. Such was the case in several tests conducted at NASA as well as in the Ariane 5 strap-on P230 engine in a static firing test where pressure oscillations of 0.5% resulted in 5% thrust oscillations. Exacerbating the situation in cryogenic test facilities, is the possibility of the formation of vapor clouds when the pressure in the wake falls below the vapor pressure leading to a cavitation instability that has a lower frequency than the primary wake-vortex instability. The cavitation instability has the potential for high amplitude fluctuations that can cause catastrophic damage in the facility. In this paper high-fidelity multi-phase numerical simulations of an orifice element are used to characterize the different instabilities, understand the dominant instability mechanisms and identify the tonal content of the instabilities.

Ahuja, Vineet↗

An Aerial Radiological Survey of Selected Areas of Area 18 - Nevada Test Site

As part of the proficiency training for the Radiological Mapping mission of the Aerial Measuring System (AMS), a survey team from the Remote Sensing Laboratory-Nellis (RSL-Nellis) conducted an aerial radiological survey of selected areas of Area 18 of the Nevada Test Site (NTS) for the purpose of mapping man-made radiation deposited as a result of the Johnnie Boy and Little Feller I tests. The survey area centered over the Johnnie Boy ground zero but also included the ground zero and deposition area of the Little Feller I test, approximately 7,000 feet (2133 meters) southeast of the Johnnie Boy site. The survey was conducted in one flight. The completed survey covered a total of 4.0 square miles. The flight lines (with the turns) over the surveyed areas are presented in Figure 1. One 2.5-hour-long flight was performed at an altitude of 100 ft above ground level (AGL) with 200 foot flight-line spacing. A test-line flight was conducted near the Desert Rock Airstrip to ensure quality control of the data. The test line is not shown in Figure 1. However, Figure 1 does include the flight lines for a ''perimeter'' flight. The path traced by the helicopter flying over distinct roads within the survey area can be used to overlay the survey data on a base map or image. The flight survey lines were flown in an east-west orientation perpendicular to the deposition patterns for both sites. This technique provides better spatial resolution when contouring the data. The data were collected by the AMS data acquisition system (REDAR V) using an array of twelve 2-inch x 4-inch x 16-inch sodium iodide (NaI) detectors flown on-board a twin-engine Bell 412 helicopter. Data, in the form of gamma energy spectra, were collected every second over the course of the survey and were geo-referenced using a differential Global Positioning System. Spectral data allows the system to distinguish between ordinary fluctuations in natural background radiation levels and the signature produced by man-made radioisotopes. Spectral data can also identify specific radioactive isotopes. Based on the results of the RSL NTS 1994 surveys, this area was chosen for a resurvey to improve the spatial resolution of the reported depositions for the Johnnie Boy and Little Feller I events. In addition, the survey was expected to confirm the absence of detectable concentrations of Americium-241 (Am-241) at the Johnnie Boy site and attempt to confirm the presence of Uranium-235 (U-235).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vapor Cooling of a Structural Skirt for a Large-Scale Hydrogen Tank

The demonstration of vapor cooling on a structural skirt was one of the main objectives of the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) testing. SHIIVER consisted of a 4-meter diameter stainless steel tank with an aluminum forward skirt. The forward skirt was cooled by directing effluent vapor from the tank through two flow channels that each went 360 degrees around the interior of the skirt in a helical pattern. Flow rates, temperatures, and pressures in the system were measured allowing for the calculation of heat load removed via cooling stream and heat load reduction into the tank. Testing occurred at fill levels between 25% and 90% full using both liquid hydrogen and liquid nitrogen. Boil-off rate was varied independent of the skirt performance by adding multilayer insulation over the spray-on-foam insulation on the tank domes, while leaving the barrel insulated only with spray-on-foam. The results from the testing, which demonstrate vapor cooling reversed heat flow from the skirt into the tank and reduces total propellant heat load by as much as 19%, are analyzed and discussed.

Cryogenic Fluid Management↗

Status of NASA advanced LFC airfoil high-lift study

The design of a high lift system for the NASA advanced LFC airfoil designed by Pfenninger is described. The high lift system consists of both leading and trailing edge flaps. A 3 meter semispan, 1 meter chord wing model using the above airfoil and high lift system is under construction and will be tested in the NASA Langley 4 by 7 meter tunnel. This model will have two separate full span leading edge flaps (0.10c and 0.12c) and one full span trailing edge flap (0.25c). The performance of this high lift system was predicted by the NASA two dimensional viscous multicomponent airfoil program. This program was also used to predict the characteristics of the LFC airfoils developed by the Douglas Aircraft Company and Lockheed-Georgia Aircraft Company.

Applin, Z. T.↗

Helicopter blade-vortex interaction locations: Scale-model acoustics and free-wake analysis results

The results of a model rotor acoustic test in the Langley 4by 7-Meter Tunnel are used to evaluate a free-wake analytical technique. An acoustic triangulation technique is used to locate the position in the rotor disk where the blade-vortex interaction noise originates. These locations, along with results of the rotor free-wake analysis, are used to define the geometry of the blade-vortex interaction noise phenomena as well as to determine if the free-wake analysis is a capable diagnostic tool. Data from tests of two teetering rotor systems are used in these analyses.

Hoad, Danny R.↗

Review of design and operational characteristics of the 0.3-meter transonic cryogenic tunnel

The fundamentals of cryogenic testing are validated both analytically and experimentally employing the 0.3-m transonic cryogenic tunnel. The tunnel with its unique Reynolds number capability has been used for a wide variety of aerodynamic tests. Techniques regarding real-gas effects have been developed and cryogenic tunnel conditions are set and maintained accurately. It is shown that cryogenic cooling, by injecting nitrogen directly into the tunnel circuit, imposes no problems with temperature distribution or dynamic response characteristics.

Ray, E. J.↗

Development of a Testbed for Pipeline Flushing - 19409

Pipelines which carry radioactive waste within the DOE complex should be properly flushed, particularly in the cases where stationary or moving beds of solid sediment occur, or lines are prone to hydrogen gas buildup. Present guidelines establish a minimum for the amount of water used for post-transfer flushing operations to achieve satisfactory cleaning of pipelines. However, further studies are needed to limit the amount of water used for flushing operations, thus minimizing the consequent downstream waste. These efforts are significantly helpful to DOE waste remediation sites by preserving tank storage, preventing additional waste processing, and minimizing dilution and changes in waste chemistry. An experimental pipe loop designed for study of non-Newtonian slurry flushing is currently being developed at the Florida International University (FIU). The testbed is designed to investigate parameters that effect the efficiency of flushing operations. The objective is to find flush velocity values/modes which lead to satisfactory cleaning of transport lines with a minimum amount of water usage. The developed methodologies will be streamlined according to the demands from both Hanford and Savannah River sites. A test matrix containing parameters such as pipeline length, flow rate, and simulant composition (solid concentration, rheology, particle size and density) has been developed. In the initial phase of testing, material composition and loop length will be fixed to a mixture of 17 wt% kaolin in water (to attain density, viscosity, and yield stress in the applicable range to operations at Savannah River and Hanford sites) and 165 feet, respectively. This matrix provides a parametric study on the flush velocity. Prescribed velocities in this test matrix comply with the maximum and minimum recommended flush velocity values by the flushing guidelines for Hanford waste (RPP-RPT-59600, Rev. 0, SRNL-STI-2015-00014, TFC-ENG-STD-26, REV C-1). Efforts will focus on creating repeatable sediment beds inside the pipeline in both fully-flooded and gravity-drained systems. Bed characterization (i.e., measurement of sediment height, solids concentration, and rheology) will be conducted to ensure consistency of initial conditions between tests. A combination of Pulse-Echo technique, Coriolis meter, and optical inspections will be used to accomplish initial bed characterization (ensuring consistency between tests), control/monitor density variations (initial bed creation, flush velocity control, and post-flush evaluations), and serve as reference (validation of PulseEcho and pipe surface cleanness evaluation), respectively. This paper will present the details of the development of the test loop and the test matrix. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Overview of Heatshield for Extreme Entry Environment Technology (HEEET) Project

The objective of the Heatshield for Extreme Entry Environment Technology (HEEET) projects is to mature a 3-D Woven Thermal Protection System (TPS) to Technical Readiness Level (TRL) 6 to support future NASA missions to destinations such as Venus and Saturn. Destinations that have extreme entry environments with heat fluxes up to 5000 watts per square centimeter and pressures up to 5 atmospheres, entry environments that NASA has not flown since Pioneer-Venus and Galileo. The scope of the project is broad and can be split into roughly four areas, Manufacturing/Integration, Structural Testing and Analysis, Thermal Testing and Analysis and Documentation. Manufactruing/Integration covers from raw materials, piece part fabrication to final integration on a 1-meter base diameter 45-degree sphere cone Engineering Test Unit (ETU). A key aspect of the project was to transfer as much of the manufacturing technology to industry in preparation to support future mission infusion. The forming, infusion and machining approaches were transferred to Fiber Materials Inc. and FMI then fabricated the piece parts from which the ETU was manufactured. The base 3D-woven material consists of a dual layer weave with a high density outer layer to manage recession in the system and a lower density, lower thermal conductivity inner layer to manage the heat load. At the start of the project it was understood that due to weaving limitations the heat shield was going to be manufactured from a series of tiles. And it was recognized that the development of a seam solution that met the structural and thermal requirements of the system was going to be the most challenging aspect of the project. It was also recognized that the seam design would drive the final integration approach and therefore the integration of the ETU was kept in-house within NASA. A final seam concept has been successfully developed and implemented on the ETU and will be discussed. The structural testing and analysis covers from characterization of the different layers of the infused material as functions of weave direction and temperature, to sub-component level testing such as 4-pt bend testing at sub-ambient and elevated temperature. ETU test results are used to validate the structural models developed using the element and sub-component level tests. Given the seam has to perform both structurally and aerothermally during entry a novel 4-pt bend test fixture was developed allowing articles to be tested while the front surface is heated with a laser. These tests are intended to establish the system's structural capability during entry. A broad range of aerothermal tests (arcjet tests) are being performed to develop material response models for predicting the required TPS thickness to meet a mission's needs and to evaluate failure modes. These tests establish the capability of the system and assure robustness of the system during entry. The final aspect of the project is to develop a comprehensive Design and Data Book such that a future mission will have the information necessary to adopt the technology. This presentation will provide an overview and status of the project and describe the status of the tehnology maturation level for the inner and outer planet as well as earth entry sample return missions.

Ellerby, Don↗

Overview of Heatshield for Extreme Entry Environment Technology (HEEET)

The objective of the Heatshield for Extreme Entry Environment Technology (HEEET) projects is to mature a 3-D Woven Thermal Protection System (TPS) to Technical Readiness Level (TRL) 6 to support future NASA missions to destinations such as Venus and Saturn. Destinations that have extreme entry environments with heat fluxes > 3500 W/sq cm and pressures up to 5 atmospheres, entry environments that NASA has not flown since Pioneer-Venus and Galileo. The scope of the project is broad and can be split into roughly four areas, Manufacturing/Integration, Structural Testing and Analysis, Thermal Testing and Analysis and Documentation. Manufacturing/Integration covers from raw materials, piece part fabrication to final integration on a 1-meter base diameter 45-degree sphere cone Engineering Test Unit (ETU). A key aspect of the project was to transfer as much of the manufacturing technology to industry in preparation to support future mission infusion. The forming, infusion and machining approaches were transferred to Fiber Materials Inc. and FMI then fabricated the piece parts from which the ETU was manufactured.

Thermal Protection System↗

Overview of Heatshield for Extreme Entry Environment Technology (HEEET)

The objective of the Heatshield for Extreme Entry Environment Technology (HEEET) projects is to mature a 3-D Woven Thermal Protection System (TPS) to Technical Readiness Level (TRL) 6 to support future NASA missions to destinations such as Venus and Saturn. Destinations that have extreme entry environments with heat fluxes > 3500 W/cm2 and pressures up to 5 atmospheres, entry environments that NASA has not flown since Pioneer-Venus and Galileo. The scope of the project is broad and can be split into roughly four areas, Manufacturing/Integration, Structural Testing and Analysis, Thermal Testing and Analysis and Documentation. Manufacturing/Integration covers from raw materials, piece part fabrication to final integration on a 1-meter base diameter 45-degree sphere cone Engineering Test Unit (ETU). A key aspect of the project was to transfer as much of the manufacturing technology to industry in preparation to support future mission infusion. The forming, infusion and machining approaches were transferred to Fiber Materials Inc. and FMI then fabricated the piece parts from which the ETU was manufactured. The base 3D-woven material consists of a dual layer weave with a high-density outer layer to manage recession in the system and a lower density, lower thermal conductivity inner layer to manage the heat load. At the start of the project it was understood that due to weaving limitations the heat shield was going to be manufactured from a series of tiles. And it was recognized that the development of a seam solution that met the structural and thermal requirements of the system was going to be the most challenging aspect of the project. It was also recognized that the seam design would drive the final integration approach and therefore the integration of the ETU was kept in-house within NASA. A final seam concept has been successfully developed and implemented on the ETU. The structural testing and analysis covers from characterization of the different layers of the infused material as functions of weave direction and temperature to sub-component level testing such as 4pt bend testing at sub-ambient and elevated temperature and culminates in testing of the ETU results from which will validate the structural models developed using the element and sub-component level tests. Given the seam has to perform both structurally and aerothermally during entry a novel 4pt bend test fixture was developed allowing articles to be tested while the front surface is heated with a laser. These tests are being utilized to establish the systems structural capability during entry.A broad range of aerothermal tests (arcjet tests) were performed to develop material response models for predicting the required TPS thickness to meet a missions needs and to evaluate failure modes and establish the capability of the system. The final aspect of the project is to develop a comprehensive Design and Data Book such that a future mission will have the information necessary to adopt the technology. This presentation will provide an overview for each of these areas and argue that HEEET has successfully achieved TRL 6.

HEEET↗

Characterization of Superhydrophobic Surfaces for Anti-icing in a Low-Temperature Wind Tunnel

In this study, a closed loop low-temperature wind tunnel was custom-built and uniquely used to investigate the anti-icing mechanism of superhydrophobic surfaces in regulated flow velocities, temperatures, humidity, and water moisture particle sizes. Silica nanoparticle-based hydrophobic coatings were tested as superhydrophobic surface models. During tests, images of ice formation were captured by a camera and used for analysis of ice morphology. Prior to and after wind tunnel testing, apparent contact angles of water sessile droplets on samples were measured by a contact angle meter to check degradation of surface superhydrophobicity. A simple peel test was also performed to estimate adhesion of ice on the surfaces. When compared to an untreated sample, superhydrophobic surfaces inhibited initial ice formation. After a period of time, random droplet strikes attached to the superhydrophobic surfaces and started to coalesce with previously deposited ice droplets. These sites appear as mounds of accreted ice across the surface. The appearance of the ice formations on the superhydrophobic samples is white rather than transparent, and is due to trapped air. These ice formations resemble soft rime ice rather than the transparent glaze ice seen on the untreated sample. Compared to untreated surfaces, the icing film formed on superhydrophobic surfaces was easy to peel off by shear flows.

36 MATERIALS SCIENCE↗

Vortex generators as a means for increasing rotor performance

Field tests on a horizontal axis wind turbine (HAWT) have shown that Vortex Generators (VGs) can increase the efficiency of large propeller type (horizontal axis) wind turbines. VGs are devices which are attached to the surfaces of an aerodynamic body to influence the boundary layer behavior. It is pointed out that VGs were originally developed for delaying stall on aircraft wings. An investigation was conducted regarding the possibility to employ VGs also for the improvement of the performance of an intermediate size HAWT with a diameter in the range from 24 to 46 meters. This investigation included wind tunnel tests involving a rotor blade tip section, and field tests. The wind tunnel tests showed that VGs can improve the peak lift capabilities of the section while only slightly increasing the drag. The field tests showed that VGs can increase the rotor power in winds above 6 m/s.

Corrigan, R. D.↗

Flow visualization in a cryogenic wind tunnel using holography

Results of holographic flow visualization from tests made in the Langley 0.3 meter transonic cryogenic tunnel are presented. The tunnel was operated over a temperature range from 100 to 300 K and a pressure range from 1.1 to 4 atm. Interferometry at the facility may be of limited use at the low temperature high pressure conditions because of the jumbled nature of the reference fringes. The shadowgraph technique appears to be the best means of visualizing shocks at these high density conditions. The spot size at the focus of the reconstructed beams was measured and used as an indicator of density fluctuations in the flow field. These density fluctuations appear to be caused by temperature fluctuations of the test gas which are relatively independent of tunnel conditions.

Burner, A. W.↗