Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Absorber Alignment Measurement Tool for Solar Parabolic Trough Collectors: Preprint

As we pursue efforts to lower the capital and installation costs of parabolic trough solar collectors, it is essential to maintain high optical performance. While there are many optical tools available to measure the reflector slope errors of parabolic trough solar collectors, there are few tools to measure the absorber alignment. A new method is presented here to measure the absorber alignmentin two dimensions to within 0.5 cm. The absorber alignment is measured using a digital camera and four photogrammetric targets. Physical contact with the receiver absorber or glass is not necessary. The alignment of the absorber is measured along its full length so that sagging of the absorber can be quantified with this technique. The resulting absorber alignment measurement provides criticalinformation required to accurately determine the intercept factor of a collector.

14 SOLAR ENERGY↗

Atmospheric Radiation Measurement (ARM) Aerosol Observing Systems (AOS) for Surface-Based In Situ Atmospheric Aerosol and Trace Gas Measurements

Aerosols alter Earth’s radiative budget both directly and indirectly through interaction with clouds. Continuous observations are required to reduce the uncertainties in climate models associated with atmospheric processing and the interactions between aerosols and clouds. Field observations of aerosols are a central component of the Atmospheric Radiation Measurement (ARM) Facility’s global measurements. The ARM mission goal is to “provide the climate research community with strategically located in situ and remote sensing observatories designed to improve the understanding and representation, in climate and earth system models, of clouds and aerosols as well as their interactions and coupling with the Earth’s surface.” Since 1996, ARM has met this goal by operating Aerosol Observing Systems (AOS) for in situ measurement of aerosols. Currently the five ARM AOSs are the most comprehensive field deployable aerosol systems in the United States. The AOS suite includes seven measurement classes: number concentration, size distribution, chemical composition, radiative and optical properties, hygroscopicity, trace gases, and supporting meteorological conditions. AOSs are designed as standardized measurement platforms to enable intercomparison across the ARM Facility for regional process studies within a global context. The instrumentation and measurement capabilities of the ARM AOSs, along with a history of their design and field deployments are presented here.

54 ENVIRONMENTAL SCIENCES↗

Optical depth measurements by shadow-band radiometers and their uncertainties

Shadow-band radiometers in general, and especially the Multi-Filter Rotating Shadow-band Radiometer (MFRSR), are widely used for atmospheric optical depth measurements. The major programs running MFRSR networks in the U.S. include DOE Atmospheric Radiation Measurement (ARM) Program, USDA UV-B Monitoring and Research Program, NOAA Surface Radiation (SURFRAD) Network, and NASA Solar Irradiance Research Network (SIRN). In this paper we discuss a number of technical issues specific for shadow-band radiometers and their impact on the optical depth measurements. These problems include instrument tilt and misalignment, as well as some data processing artifacts. Techniques for data evaluation and automatic detection of some of these problems are described.

47 OTHER INSTRUMENTATION↗

Radiometry and metrology of a phase zone plate measured by extreme ultraviolet synchrotron radiation

The diffraction efficiency, focal length, and other radiometric and metrology properties of a phase zone plate were measured by using monochromatic synchrotron radiation in the 7-18.5 nm wavelength range. The zone plate was composed of molybdenum zones having a 4 mm outer diameter and 70 nm nominal thickness and supported on a 100 nm thick silicon nitride membrane. The diffraction efficiency was enhanced by the phase shift of the radiation passing through the zones. The measured first-order efficiency was in good agreement with the calculated efficiency. The properties of the zone plate, particularly the small variation of the efficiency with off-axis angle, make it suitable for use in a radiometer to accurately measure the absolutely calibrated extreme ultraviolet emission from the Sun.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Analysis of a Halo-Measurement Diagnostics

A large dynamical-range diagnostics (LDRD) design at Jefferson Lab will be used at the FAST-IOTA injector to measure the transverse distribution of halo associated with a high-charge electron beam. One important aspect of this work is to explore the halo distribution when the beam has significant angular momentum (i.e. is magnetized). The beam distribution is measured by recording radiation produced as the beam impinges a YAG:Ce screen. The optical radiation is split with a fraction directed to a charged-couple device (CCD) camera. The other part of the radiation is reflected by a digital micromirror device (DMD) that masks the core of the beam distribution. Combining the images recorded by the two cameras provides a measurement of the transverse distribution with over a large dynamical range. The design and analysis of the optical system will be discussed including optical simulation using SRW and the result of a mockup experiment to test the performances of the system will be presented.

43 PARTICLE ACCELERATORS↗

Final design and first use of in-situ measuring apparatus for measurement of permanent magnet resiliency in CEBAF’s radiation environment

In this work we outline the final design and initial measurement lessons for the holders and measuring apparatus of the permanent magnet resiliency experiment which is a part of the FFA@CEBAF proposed upgrade. The experiment will expose permanent magnets to the radiation environment of CEBAF. Due to safety regulations we need to measure the magnets in the tunnel without bringing them out, so we designed a mobile measuring system as well as a series of protocols to allow us to speedily measure these samples even under adverse conditions. We also designed our system to be capable of taking measurements even with component failures.

Accelerator Physics↗

Measurement of cross section of quark pair production top with the D0 experiment at the Tevatron and determination the top quark mass using this measure

The top quark has been discovered by CDF and D0 experiments in 1995 at the proton-antiproton collider Tevatron. The amount of data recorded by both experiments makes it possible to accurately study the properties of this quark: its mass is now known to better than 1% accuracy. This thesis describes the measurement of the top pair cross section in the electron muon channel with 4, 3 fb -1 recorded data between 2006 and 2009 by the D0 experiment. Since the final state included a muon, improvements of some aspects of its identification have been performed : a study of the contamination of the cosmic muons and a study of the quality of the muon tracks. The cross section measurement is in good agreement with the theoretical calculations and the other experimental measurements. This measurement has been used to extract a value for the top quark mass. This method allows for the extraction of a better defined top mass than direct measurements as it depends less on Monte Carlo simulations. The uncertainty on this extracted mass, dominated by the experimental one, is however larger than for direct measurements. In order to decrease this uncertainty, the ratio of the Z boson and the top pair production cross sections has been studied to look for some possible theoretical correlations. At the Tevatron, the two cross sections are not theoretically correlated: no decrease of the uncertainty on the extracted top mass is therefore possible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NMR Measurements for Solid Polarized Targets at Jefferson Lab

Jefferson Lab's solid polarized targets rely on Nuclear Magnetic Resonance techniques to measure the enhanced polarization provided under Dynamic Nuclear Polarization. Upcoming polarized target experiments in JLab's Hall B present challenging conditions which would benefit from improvements to traditional NMR techniques. For decades, JLab has utilized Liverpool Q Meters for NMR measurements, but these are aging and no longer produced. The polarized target group at Bochum has successfully produced replacement Q Meters with modern components, and we are following their example, exploring new designs for both an analog and a digital Q Meter system. Unlike recent experiments in Halls A and C, the new Hall B target will require external NMR coils, resulting in a weaker signal. In addition, two separate target cells will be utilized, each held at different magnetic fields, allowing them to be polarized in opposing directions, but complicating the NMR measurement. We present the challenges presented by the new Hall B target, lay out plans for improvements to our NMR system, and show results of initial tests of our designs.

Maxwell, James↗

Development of a Wind Plant Large-Eddy Simulation with Measurement-Driven Atmospheric Inflow: Preprint

This paper details the development of an aeroelastic wind plant model with large-eddy simulation (LES). The chosen LES solver is the Simulator for Wind Farm Applications (SOWFA) based on the OpenFOAM framework, coupled to NREL's comprehensive aeroelastic analysis tool, FAST. An atmospheric boundary layer (ABL) precursor simulation was constructed based on assessments of meteorological tower, lidar, and radar data over a 3-hour window. This precursor was tuned to the specific atmospheric conditions that occurred both prior to and during the measurement campaign, enabling capture of a night-to-day transition in the turbulent ABL. In the absence of height-varying temperature measurements, spatially averaged radar data were sufficient to characterize the atmospheric stability of the wind plant in terms of the shear profile, and near-ground temperature sensors provided a reasonable estimate of the ground heating rate describing the morning transition. A full aeroelastic simulation was then performed for a subset of turbines within the wind plant, driven by the precursor. Analysis of two turbines within the array, one directly waked by the other, demonstrated good agreement with measured time-averaged loads.

17 WIND ENERGY↗

X-ray Beam Induced Current Measurements for Multi-Modal X-ray Microscopy of Solar Cells

X-ray beam induced current (XBIC) measurements allow mapping of the nanoscale performance of electronic devices such as solar cells. Ideally, XBIC is employed simultaneously with other techniques within a multi-modal X-ray microscopy approach. An example is given herein combining XBIC with X-ray fluorescence to enable point-by-point correlations of the electrical performance with chemical composition. For the highest signal-to-noise ratio in XBIC measurements, lock-in amplification plays a crucial role. By this approach, the X-ray beam is modulated by an optical chopper upstream of the sample. The modulated X-ray beam induced electrical signal is amplified and demodulated to the chopper frequency using a lock-in amplifier. By optimizing low-pass filter settings, modulation frequency, and amplification amplitudes, noise can efficiently be suppressed for the extraction of a clear XBIC signal. A similar setup can be used to measure the X-ray beam induced voltage (XBIV). Beyond standard XBIC/XBIV measurements, XBIC can be measured with bias light or bias voltage applied such that outdoor working conditions of solar cells can be reproduced during in-situ and operando measurements. Ultimately, the multi-modal and multi-dimensional evaluation of electronic devices at the nanoscale enables new insights into the complex dependencies between composition, structure, and performance, which is an important step towards solving the materials' paradigm.

14 SOLAR ENERGY↗

DYNAMICAL MASS MEASUREMENT OF THE YOUNG SPECTROSCOPIC BINARY V343 NORMAE AaAb RESOLVED WITH THE GEMINI PLANET IMAGER

We present new spatially resolved astrometry and photometry from the Gemini Planet Imager of the inner binary of the young multiple star system V343 Normae, which is a member of the β Pictoris (β Pic) moving group. V343 Normae comprises a K0 and mid-M star in a ∼4.5 year orbit (AaAb) and a wide 10″ M5 companion (B). By combining these data with archival astrometry and radial velocities we fit the orbit and measure individual masses for both components of M{sub Aa}=1.10±0.10 M{sub ⊙} and M{sub Ab}=0.290±0.018 M{sub ⊙}. Comparing to theoretical isochrones, we find good agreement for the measured masses and JHK band magnitudes of the two components consistent with the age of the β Pic moving group. We derive a model-dependent age for the β Pic moving group of 26 ± 3 Myr by combining our results for V343 Normae with literature measurements for GJ 3305, which is another group member with resolved binary components and dynamical masses.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of volatile organic compounds at a suburban ground site (T1) in Mexico City during the MILAGRO 2006 campaign: Measurement comparison, emission ratios, and source attribution

Volatile organic compound (VOC) mixing ratios were measured with two different instruments at the T1 ground site in Mexico City during the Megacity Initiative: Local and Global Research Observations (MILAGRO) campaign in March of 2006. A gas chromatograph with flame ionization detector (GC-FID) quantified 18 light alkanes, alkenes and acetylene while a proton-transfer-reaction ion-trap mass spectrometer (PIT-MS) quantified 12 VOC species including oxygenated VOCs (OVOCs) and aromatics. A GC separation system was used in conjunction with the PIT-MS (GC-PIT-MS) to evaluate PIT-MS measurements and to aid in the identification of unknown VOCs. The VOC measurements are also compared to simultaneous canister samples and to two independent proton-transfer-reaction mass spectrometers (PTR-MS) deployed on a mobile and an airborne platform during MILAGRO. VOC diurnal cycles demonstrate the large influence of vehicle traffic and liquid propane gas (LPG) emissions during the night and photochemical processing during the afternoon. Emission ratios for VOCs and OVOCs relative to CO are derived from early-morning measurements. Average emission ratios for non-oxygenated species relative to CO are on average a factor of {approx}2 higher than measured for US cities. Emission ratios for OVOCs are estimated and compared to literature values the northeastern US and to tunnel studies in California. Positive matrix factorization analysis (PMF) is used to provide insight into VOC sources and processing. Three PMF factors were distinguished by the analysis including the emissions from vehicles, the use of liquid propane gas and the production of secondary VOCs + long-lived species. Emission ratios to CO calculated from the results of PMF analysis are compared to emission ratios calculated directly from measurements. The total PIT-MS signal is summed to estimate the fraction of identified versus unidentified VOC species.

54 ENVIRONMENTAL SCIENCES↗

The measurement of carbon monoxide and methane in the National Capital Air Quality Control Region. I - Measurement systems

The Carbon Monoxide Pollution Experiment (COPE) and the National Capital Air Quality Control Region (NCAQCR) undertook a series of measurements of atmospheric CO and CH4 to determine the accuracy of the airborne COPE Correlation Interfer4meter. The device, a modified Michelson interferometer, measures the atmospheric column density of CO and CH4 at 2.3 microns with tropospheric measurement sensitivities of 70 and 10 PPB, respectively. Data for evaluating the remote measurements included atmospheric column density measurements at a ground truth site using a van-mounted infrared Fourier spectrometer; continuous ground level gas chromatographic measurements; and chromatographic data from atmospheric grab samples collected by aircraft and at ground locations. The instruments and sampling techniques used in the experiment are described in detail.

Lebel, P. J.↗

Satellite and correlative measurements of the stratospheric aerosol. II Comparison of measurements made by SAM II, dustsondes and airborne lidar

Results are shown from the first set of measurements conducted to validate extinction data from the Stratospheric Aerosol Measurement II (SAM II). Dustsonde-measured number density profiles and lidar-measured backscattering profiles for two days are converted to extinction profiles, and are shown to agree within their respective uncertainties at all heights above the tropopause. Near the tropopause, agreement depends on use of model size distributions with larger particles, having radii greater than 0.6 microns. The presence of such large particles is supported by measurements made elsewhere, is suggested by the in situ size distribution measurements reported, and is likely to have an important bearing on the radiative impact of the total stratospheric aerosol. It is concluded that the SAM II extinction data and uncertainty estimates are supported.

Russell, P. B.↗

Measures of measurement adequacy

The adequacy of a measurement instrument is often characterized in terms of the precision, accuracy, and confidence that can be assigned to the measurements that it produces. The accuracy of the measurement may be defined as the size of the difference between the true and measured values. The precision of the system over a large number of measurements may be defined in terms of the sample standarad deviation. The confidence in an interval-values measurement may be defined as the probability that this interval contains the true value. These concepts are discussed in terms of their mathematical solutions.

Source record↗

Determining surface solar absorption from broadband satellite measurements for clear skies - Comparison with surface measurements

Using data from collocated satellite pixel measurements obtained during the Earth Radiation Budget Experiement and near-surface measurements carried out at the Boulder Atmospheric Observatory Tower, the shortwave (SW) surface radiation from broadband satellite measurements for clear-sky conditions was compared with surface measurements. Results demonstrate that the surface-SW absorption is a more meaningful quantity for climate studies than is surface insolation. It is also shown that a direct evaluation of the surface-SW absorption can be more accurately obtained from satellite measurements than can be surface insolation. An algorithm is presented for transferring satellite SW measurements to surface-SW absorption.

Cess, Robert D.↗

Lidar Measurements of Stratospheric Ozone, Temperature and Aerosol During 1992 UARS Correlative Measurement Campaign

Measurements of stratospheric ozone, temperature, and aerosols were made by the NASA/GSFC mobile stratospheric lidar during the UARS (Upper Atmospheric Research Satellite) Correlative Measurement Campaign at the JPL-Table Mountain Facility in Feb. and Mar. 1992. Due to the presence of substantial amounts of residual volcanic aerosol from the eruption of Mt. Pinatubo, the GSFC lidar system was modified for an accurate measurement of ozone concentration in the stratosphere. While designed primarily for the measurement of stratospheric ozone, this lidar system was also used to measure middle atmosphere temperature and density from 30 to 65 km and stratospheric aerosol from 15 to 35 km. In the following sections, we will briefly describe and present some typical measurements made during this campaign. Stratospheric ozone, temperature, and aerosols profiles derived from data taken between 15 Feb. and 20 Mar., 1992 will be presented at the conference.

Mcgee, Thomas J.↗

Results of the second Round Robin on opening-load measurement conducted by ASTM Task Group E24.04.04 on crack closure measurement and analysis

A second experimental Round Robin on the measurement of the crack opening load in fatigue crack growth tests has been completed by the ASTM Task Group E24.04.04 on Crack Closure Measurement and Analysis. Fourteen laboratories participated in the testing of aluminum alloy compact tension specimens. Opening-load measurements were made at three crack lengths during constant Delta K, constant stress ratio tests by most of the participants. Four participants made opening-load measurements during threshold tests. All opening-load measurements were based on the analysis of specimens compliance behavior, where the displacement/strain was measured either at the crack mouth or the mid-height back face location. The Round Robin data were analyzed for opening load using two non-subjective analysis methods: the compliance offset and the correlation coefficient methods. The scatter in the opening load results was significantly reduced when some of the results were excluded from the analysis population based on an accept/reject criterion for raw data quality. The compliance offset and correlation coefficient opening load analysis methods produced similar results for data populations that had been screened to eliminate poor quality data.

Phillips, E. P.↗