Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement bandwidth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Optimal filtering and generation of entangled photons for quantum applications in the presence of noise

Filtering is commonly used in quantum optics to reject noise photons, and also to enable interference between independent photons. However, filtering the joint spectrum of photon pairs can reduce the inherent coincidence probability or loss-independent heralding efficiency. Here we investigate filtering for multiphoton applications based on entanglement and interference (e.g., quantum teleportation). We multiplex C-band entangled photons and C-band classical communications into the same long-distance fibers, which enables scalable low-loss quantum networking but requires filtering of spontaneous Raman scattering noise from classical light. Using tunable-bandwidth filters, low-jitter detectors, and polarization filters, we distribute wavelength-degenerate time-bin entangled photons in the C band (1536.5 nm) over 25 km/25 km standard fibers (50 km) each carrying 10 Gbit/s C-band classical data signals. Narrow filtering enables milliwatt-level C-band power, which exceeds the power achieved by comparable studies by roughly an order of magnitude and could feasibly support terabit per second classical rates. We evaluate how performance depends on pump and filter bandwidths, multipair emission, filter shapes, loss, phase matching, and how quantum information is measured. We find a trade-off between reducing noise impact and increasing single-mode purity, and discuss mitigation methods toward optimal multiphoton applications. Importantly, these results apply to noise in free space and in quantum devices (sources, frequency converters, switches, detectors, etc.) and provide insight into filter-induced degradation of single-photon purity and rates even in noise-free environments.

Thomas, Jordan M. [Fermilab; Northwestern U.]↗

Observations of six flat spectrum sources from the 5 GHz survey

Observations at radio, optical, and X-ray wavelengths of six sources from the Bonn-NRAO 5 GHz survey are reported. The sources were selected on the basis of their flux densities and spectral indices at 5 GHz. All have been shown to contain compact radio cores and to emit strongly at X-ray wavelengths; five are strongly polarized at optical wavelengths. The measured flux densities suggest that the sources are of comparable luminosity (per fractional bandwidth) in the X-ray and optical regions. The interpretation of these results in terms of a synchrotron-self-Compton mechanism is briefly discussed.

Biermann, P.↗

Simplified Laser Tuning

Tuning arrangement employs single grating and two planar mirrors. Arrangement of front-surface mirrors and single holographic grating significantly reduces spectral bandwidth and simplified tuning of laser output. Laser used to induce fluorescence in measuring concentrations of trace species, such as OH radical, in atmosphere.

Mcdermid, I. S.↗

Superconducting Nbti and Pb(cu) Bandpass Filters

Superconducting Nb0.45Ti0.55 and Pb electroplated on Cu bandpass microwave filtes were constructed to investigate their low loss properties at 4.7 K. An interdigital stripline filter configuration was selected as the optimum structure for future applications. The filter was designed to operate at 8.45 GHz with an equal ripple bandwidth of 0.15 GHz. The insertion loss and the noise temperature contribution were measured at 4.7 K. In addition, the insertion loss was studied as a function of out of band power (up to 1 watt) and temperature (4.7 K up to T(c)). Results of an oxygen free high conductivity Cu filter are included for comparison.

Bautista, J. J.↗

Superconducting NbTi and Pb(Cu) bandpass filters

Superconducting NbO.45Ti0.55 and Pb electroplated on Cu bandpass microwave filters were constructed to investigate their low loss properties at 4.7 K. An interdigital stripline filter configuration was selected as the optimum structure for future applications. The filter was designed to operate at 8.45 GHz with an equal ripple bandwidth of 0.15 GHz. The insertion loss and the noise temperature contribution were measured at 4.7 K. In addition, the insertion loss was studied as a function of out of band power (up to 1 watt) and temperature (4.7 K up to Tc). Results of an oxygen free high conductivity Cu filter are included for comparison.

Bautista, J. J.↗

Nonradiative relaxation and laser action in tunable solid state laser crystals

Room-temperature pulsed laser action was obtained in chromium-activated forsterite (Cr:Mg2SiO4) for both 532 and 1064 nm pumping. Free running laser emission in both cases is centered at 1235 nm and has a bandwidth of approximately 30 nm. Slope efficiency as high as 22 percent was measured. Using different sets of output mirrors and a single birefrigent plate as the intracavity wavelength selecting element tunability over the 1167 to 1268 nm spectral range was demonstrated. Continuous wave laser operation at room temperature was obtained for 1064 nm pumping from a CW Nd:YAG laser. The output power slope efficiency is 6.8 percent. The gain cross section is estimated to be 1.1 x 10 to the 19th sq cm. Spectroscopic studies suggest that the laser action is due to a center other than the trivalent chromium (Cr 3+), presumably the tetravalent chromium (Cr 4+) in a tetrahedrally coordinated site.

Petricevic, V.↗

A sophisticated, multi-channel data acquisition and processing system for high frequency noise research

A sophisticated, multi-channel computerized data acquisition and processing system was developed at the NASA LeRC for use in noise experiments. This technology, which is available for transfer to industry, provides a convenient, cost-effective alternative to analog tape recording for high frequency acoustic measurements. This system provides 32-channel acquisition of microphone signals with an analysis bandwidth up to 100 kHz per channel. Cost was minimized through the use of off-the-shelf components. Requirements to allow for future expansion were met by choosing equipment which adheres to established industry standards for hardware and software. Data processing capabilities include narrow band and 1/3 octave spectral analysis, compensation for microphone frequency response/directivity, and correction of acoustic data to standard day conditions. The system was used successfully in a major wind tunnel test program at NASA LeRC to acquire and analyze jet noise data in support of the High Speed Civil Transport (HSCT) program.

Hall, David G.↗

Characterization of resonant tunneling diodes for microwave and millimeter-wave detection

The authors report on the direct detection capabilities of resonant tunneling diodes in the 10-100 GHz range. An open circuit voltage sensitivity of 1750 mV/mW (in Ka-band) was measured. This is higher than the sensitivity of comparatively based commercially available solid-state detectors. The detector properties are a strong function of diode bias and the measured tangential signal sensitivity (-32 dBm at Ka-band with 1-MHz bandwidth) and the dynamic range (25 dB) of the diode are smaller compared to other solid-state detectors.

Mehdi, I.↗

Coplanar Waveguide Aperture Coupled Patch Antennas with Ground Plane/Substrate of Finite Extent

Coplanar waveguide (CPW)/aperture coupled microstrip patch antennas constructed with ground coplanar waveguide (GCPW), finite coplanar waveguide (FCPW) and channelized coplanar waveguide (CCPW) are demonstrated. The measured characteristics show that the CCPW/aperture coupled microstrip patch antenna has the largest bandwidth, whereas the GCPW/aperture coupled microstrip patch antenna has the best front-to-back ratio.

Simons, R. N.↗

Suspended Patch Antenna Array With Electromagnetically Coupled Inverted Microstrip Feed

The paper demonstrates a four-element suspended patch antenna array, with a parasitic patch layer and an electromagnetically coupled inverted microstrip feed, for linear polarization at K-Band frequencies. This antenna has the following advantages over conventional microstrip antennas: First, the inverted microstrip has lower attenuation than conventional microstrip; hence, conductor loss associated with the antenna corporate feed is lower resulting in higher gain and efficiency. Second, conventional proximity coupled patch antennas require a substrate for the feed and a superstrate for the patch. However, the inverted microstrip fed patch antenna makes use of a single substrate, and hence, is lightweight and low cost. Third, electromagnetic coupling results in wider bandwidth. Details regarding the design and fabrication will be presented as well as measured results including return loss, radiation patterns and cross-polarization levels.

Simons, Rainee N.↗

Applications Performance on NAS Intel Paragon XP/S - 15#

The Numerical Aerodynamic Simulation (NAS) Systems Division received an Intel Touchstone Sigma prototype model Paragon XP/S- 15 in February, 1993. The i860 XP microprocessor with an integrated floating point unit and operating in dual -instruction mode gives peak performance of 75 million floating point operations (NIFLOPS) per second for 64 bit floating point arithmetic. It is used in the Paragon XP/S-15 which has been installed at NAS, NASA Ames Research Center. The NAS Paragon has 208 nodes and its peak performance is 15.6 GFLOPS. Here, we will report on early experience using the Paragon XP/S- 15. We have tested its performance using both kernels and applications of interest to NAS. We have measured the performance of BLAS 1, 2 and 3 both assembly-coded and Fortran coded on NAS Paragon XP/S- 15. Furthermore, we have investigated the performance of a single node one-dimensional FFT, a distributed two-dimensional FFT and a distributed three-dimensional FFT Finally, we measured the performance of NAS Parallel Benchmarks (NPB) on the Paragon and compare it with the performance obtained on other highly parallel machines, such as CM-5, CRAY T3D, IBM SP I, etc. In particular, we investigated the following issues, which can strongly affect the performance of the Paragon: a. Impact of the operating system: Intel currently uses as a default an operating system OSF/1 AD from the Open Software Foundation. The paging of Open Software Foundation (OSF) server at 22 MB to make more memory available for the application degrades the performance. We found that when the limit of 26 NIB per node out of 32 MB available is reached, the application is paged out of main memory using virtual memory. When the application starts paging, the performance is considerably reduced. We found that dynamic memory allocation can help applications performance under certain circumstances. b. Impact of data cache on the i860/XP: We measured the performance of the BLAS both assembly coded and Fortran coded. We found that the measured performance of assembly-coded BLAS is much less than what memory bandwidth limitation would predict. The influence of data cache on different sizes of vectors is also investigated using one-dimensional FFTs. c. Impact of processor layout: There are several different ways processors can be laid out within the two-dimensional grid of processors on the Paragon. We have used the FFT example to investigate performance differences based on processors layout.

Saini, Subhash↗

Sideband-Separating, Millimeter-Wave Heterodyne Receiver

Researchers have demonstrated a submillimeter-wave spectrometer that combines extremely broad bandwidth with extremely high sensitivity and spectral resolution to enable future spacecraft to measure the composition of the Earth s troposphere in three dimensions many times per day at spatial resolutions as high as a few kilometers. Microwave limb sounding is a proven remote-sensing technique that measures thermal emission spectra from molecular gases along limb views of the Earth s atmosphere against a cold space background.

Ward, John S.↗

Balanced light detector

A system and method with AC coupling that reserves photodiode bandwidth in a biased configuration, allows optimal transimpedance amplifier performance, retains DC signal measurement capability, and does not introduce noise into the balanced detection signal.

Williams, Brian P.↗

Balanced light detector

A system and method with AC coupling that reserves photodiode bandwidth in a biased configuration, allows optimal transimpedance amplifier performance, retains DC signal measurement capability, and does not introduce noise into the balanced detection signal.

Williams, Brian P.↗

Gain-Compensating Circuit For NDE and Ultrasonics

High-frequency gain-compensating circuit designed for general use in nondestructive evaluation and ultrasonic measurements. Controls gain of ultrasonic receiver as function of time to aid in measuring attenuation of samples with high losses; for example, human skin and graphite/epoxy composites. Features high signal-to-noise ratio, large signal bandwidth and large dynamic range. Control bandwidth of 5 MHz ensures accuracy of control signal. Currently being used for retrieval of more information from ultrasonic signals sent through composite materials that have high losses, and to measure skin-burn depth in humans.

Kushnick, Peter W.↗

Monochromatic Measurements of the JPSS-1 VIIRS Polarization Sensitivity

Polarization sensitivity is a critical property that must be characterized for spaceborne remote sensing instruments designed to measure reflected solar radiation. Broadband testing of the first Joint Polar-orbiting Satellite System (JPSS-1) Visible Infrared Imaging Radiometer Suite (VIIRS) showed unexpectedly large polarization sensitivities for the bluest bands on VIIRS (centered between 400 and 600 nm). Subsequent ray trace modeling indicated that large diattenuation on the edges of the bandpass for these spectral bands was the driver behind these large sensitivities. Additional testing using the National Institute of Standards and Technologies Traveling Spectral Irradiance and Radiance Responsivity Calibrations Using Uniform Sources was added to the test program to verify and enhance the model. The testing was limited in scope to two spectral bands at two scan angles; nonetheless, this additional testing provided valuable insight into the polarization sensitivity. Analysis has shown that the derived diattenuation agreed with the broadband measurements to within an absolute difference of about0.4 and that the ray trace model reproduced the general features of the measured data. Additionally, by deriving the spectral responsivity, the linear diattenuation is shown to be explicitly dependent on the changes in bandwidth with polarization state.

Monochromatic↗

Infrared Imagery of Shuttle (IRIS). Task 2

An opto-electronic breadboard of 10 channels of the IR temperature measuring system was produced as well as a scaled up portion of the tracking system reticle in order to verify Task 1 assumptions. The breadboards and the tests performed on them are described and both raw and reduced data are presented. Tests show that the electronics portion of the imaging system will provide a dc to 10,000 Hz bandwidth that is flat and contributes no more than 0.4% of full-scale uncertainty to the measurement. Conventional packaging is adequate for the transresistance amplifier design. Measurement errors expected from all sources tested are discussed.

Chocol, C. J.↗

Predicting the Seawater Chemistry of an Ocean World Using Machine Learning on Isotopic Measurements of Volatile CO2

Introduction: Given the long time intervals required for data transmission to and from ocean worlds targets, low bandwidth for data transmission, time required for data processing and analysis, and potentially extreme radiation environments (e.g., Europa), it is clear that ocean worlds missions will need more autonomous flight instruments and software in order to achieve established science goals. Protracted time intervals for data analysis (e.g., Europa Lander) strongly motivates the development of rapid, consistent and streamlined methods for interpreting data from flight mass spectrometers to e.g., determine how mass spectra from a plume or surface liquid/ice relates to the surface/subsurface. Since mass spectrometry also has the potential to correctly identify biosignatures[1], it is imperative that such methods for interpreting data are consistent and accurate. We used 848 isotope ratio mass spectra from laboratory analyses of CO2 that interacted with ocean worlds-relevant seawaters as a ‘training’ dataset for ‘unsupervised’ machine learning. In unsupervised learning, characteristics of the data are not labeled or linked, and any similarities found only result from the neural network. CO2 isotopologues analyzed for this dataset mimic the remote measurements of CO2 by a flight mass spectrometer, and are detailed in Theiling [2]. From this dataset, we used measured features of the spectra, such as retention time, intensity, and (isotopologue) mass ratios as inputs for our autoencoder neural network. Our neural network was trained to find similarities in these and other spectral features for seawaters of a particular composition and amount of initial CO2. Successful training then created an output of these similarities for various seawaters, which included MgSO4, Na2SO4, NaCl, MgCl2, KCl, and NaHCO3, and combinations of these salts. We then applied dimensionality reduction techniques such as Principal Component Analysis (PCA), T-Distributed Stochastic Neighbor Embedding (TSNE), and Uniform Manifold Approximation and Projection (UMAP) to demonstrate latent data features as a two-dimensional projection in a unitless, high-dimensional space. In this projection, a data point represents the combined effect of spectral features such as intensity, retention time, and isotope ratio. Our initial UMAP demonstrates data clustering (organization of the data by the neural network) based on the amount of CO2 that had initially interacted with each seawater. Further training using more ‘supervised’ learning techniques demonstrate strong clustering of preliminary data based on initial CO2 concentration, seawater chemical composition, and ionic strength (salinity). Our preliminary work therefore suggests that machine learning has the potential to identify compositional variants of an ocean world seawater based on mass spectra from volatile CO2 measurements. Acknowledgments: This work was funded through a Strategic Task Group at NASA Goddard Space Flight Center. The training dataset was collected through funding from the Oklahoma Space Grant Consortium. References: [1] Pappalardo, R. et al. (2013) Astrobiology, 13, 740–773. [2] Theiling (2020) Icarus, 114216.

Europa↗