Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mass”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

URANIUM HOLDUP MONITORING WITH COMPTON IMAGING AS FUNCTION OF DEPTH AND MASS

Mass quantification using standoff gamma detection is a logical progression for MC&A applications in uranium processing facilities. While obtaining a ground truth from physical collection and weighing of masses is ideal and routine, it poses a logistical problem from both a standpoint of ALARA programs as well as interruptions to operations. The standard approach is the Generalized Geometry in Holdup (GGH) method that can apply for many cases where geometries of the holdup match simulated models; however, there are many cases where a model may not exist or a feature of the holdup geometry is such that it does not match a model particularly well.1 Gamma imaging at standoff distances and outside process equipment has potential to address these shortcomings and improve mass estimations while reducing personnel exposure; however, algorithms still require a significant degree of benchmarking to build sufficient confidence in algorithms before displacing GGH in some procedures. This paper presents the creation of a set of laboratory standards of depleted U3O8 in fixed size containers covering a range of masses and effective thicknesses up to the infinite thickness for the 185-keV line. These blocks are identically sized aluminum boxes loaded such that a thin, flat face is placed towards the imager, while the back side contains closed cell foam to apply pressure to keep the powder in a fixed position at the front face as the sources are manipulated for measurements. Included is an analysis of the mass estimation using a commercially available Compton imaging instrument where multiple geometries are created showing limitations in current methodologies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Search for Low mass Higgs Portal Scalars at the MicroBooNE Detector in the NuMI Beam

The MicroBooNE experiment exploits Liquid Argon Time Projection Chamber (LArTPC) technology to detect neutrinos from two beams at Fermilab, Chicago: on-axis Booster Neutrino Beam (BNB) and the off-axis Neutrinos at the Main Injector (NuMI) beam. While the aim of the experiment is to study the low-energy excess of electron neutrino events observed by the MiniBooNE experiment, to search for eV-scale sterile neutrinos and to characterise neutrino interactions on argon, it could also be exploited to probe Beyond Standard Model (BSM) Physics. This thesis presents a BSM search for low-mass Higgs Portal Scalars at MicroBooNE in the NuMI beam using data collected during the Run 1 and Run 3 data-taking periods with a total exposure corresponding to $7.01 \times 10^{20}$ protons on target (POT). The Higgs Portal Model is an extension to the Standard Model in which a dark-sector scalar, $S$, mixes with the Higgs boson with mixing angle $\theta$ and acquires a coupling to the Standard Model fermions via the Higgs Yukawa coupling. We search for low-mass Higgs Portal scalars, in the mass range $100-200$ MeV, at MicroBooNE via the production channel $K \rightarrow \pi + S$, where scalars are produced from kaons decaying at rest in the NuMI target and beam dump, as well as kaons decaying in flight in the decay pipe of the NuMI beam. In the MicroBooNE detector, we search for the decay channel $S \rightarrow e^+e^-$, which is the only decay channel available to the scalars in the mass range of our search. The results are expressed as limits, at the 95\% confidence level, on the scalar-Higgs mixing angle $\theta$ for scalars in the mass range $100-200$ MeV.Date of Award1 Aug 2023Original languageEnglishAwarding InstitutionThe University of ManchesterSupervisorStefan Soldner-Rembold (Supervisor) & Justin Evans (Supervisor)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Kinematic Sunyaev--Zel'dovich Measurements Across Halo Mass and Redshift with DESI DR2 and ACT DR6: Part II. Bright Galaxy Survey and Emission-Line Galaxies

We present the first high-significance spectroscopic stacked kinetic Sunyaev-Zel'dovich (kSZ) measurements of circumgalactic gas profiles for both Bright Galaxy Survey (BGS) and Emission Line Galaxy (ELG) tracers, combining DESI Data Release 2 with ACT Data Release 6. Using reconstructed line-of-sight velocities from the DESI galaxies and high-resolution ACT temperature maps, we detect the kSZ signal at high significance, reaching signal-to-noise ratios of up to $\sim$9 for BGS and $\sim$7.5 for ELGs in optimal stellar-mass selections. Together with the LRG measurements presented in Paper I, these constitute the most significant kSZ detections from any spectroscopic survey to date. We perform the analysis in both real and harmonic space, obtaining consistent results. By splitting both tracers into stellar-mass bins, we study the scaling of the kSZ amplitude with galaxy properties. Combining the kSZ measurements with ACT Data Release 6 (DR6) CMB lensing maps enables a joint calibration of the galaxy-halo connection and the gas fractions of host halos. For the BGS galaxies, we observe low gas fractions around the virial radius relative to standard expectations, likely attributable to active galactic nuclei (AGN) activity. We find some evidence for higher-mass halos retaining a larger fraction of their baryons, consistent with more efficient feedback in lower-mass systems. For the ELG sample, dominated by blue, star-forming galaxies, we provide the first detection of the gas distribution in ELG host halos. The ELGs appear to exhibit relatively high gas fractions, which points to the possibility of weaker feedback (due to e.g. low AGN and supernova feedback activity) at their mass scale. Finally, we present generalized Navarro-Frenk-White (GNFW) fits to the harmonic-space measurements, providing a compact parametrization of gas profiles for forward modeling in large-scale structure analyses.

Hadzhiyska, B. [Cambridge U.; Cambridge U., Inst. ↗

A Dual-Gated Structures for Lossless Ion Manipulations-Ion Mobility Orbitrap Mass Spectrometry Platform for Combined Ultra-High-Resolution Molecular Analysis

High-resolution ion mobility spectrometry-mass spectrometry (HR-IMS-MS) instruments have enormously advanced the ability to characterize complex biological mixtures. Unfortunately, HR-IMS and HR-MS measurements are typically performed independently due to mismatches in analysis time scales. Here we overcome this limitation by using a dual-gated ion injection approach to couple an 11-meter path length structures for lossless ion manipulations (SLIM) module to a Q-Exactive Plus Orbitrap MS. The dual-gate setup was implemented by placing one ion gate before the SLIM module and a second ion gate after. The dual-gated ion injection approach allowed the new SLIM-Orbitrap platform to simultaneously perform an 11-meter SLIM separation, Orbitrap mass analysis using the highest selectable mass resolution setting (up to 140k), and high-energy collision induced dissociation (HCD) in ~25 minutes over an $m/z$ range of ~1500 amu. The SLIM-Orbitrap was initially characterized using a mixture of standard phosphazene cations and demonstrated an average SLIM CCS resolving power (Rp CCS ) of ~218 and SLIM peak capacity of ~156 while simultaneously obtaining high mass resolutions. SLIM-Orbitrap analysis with fragmentation was then performed on mixtures of standard peptides and two reverse peptides (SDGRG 1+ , GRGDS 1+ , Rp CCS = 305) to demonstrate the utility of combined HR-IMS-MS/MS measurements for peptide identification. Our new HR-IMS-MS/MS capability was further demonstrated by analyzing a complex lipid mixture and showcasing SLIM separations on isobaric lipids. In conclusion, this new SLIM-Orbitrap platform demonstrates a critical new capability for proteomics and lipidomics applications, and the high-resolution multimodal data obtainable with this system establishes the foundation for reference-free identification of unknown ion structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data and scripts associated with a manuscript investigating impacts of solid phase extraction on freshwater organic matter optical signatures and mass spectrometry pairing

This data package is associated with the publication “Investigating the impacts of solid phase extraction on dissolved organic matter optical signatures and the pairing with high-resolution mass spectrometry data in a freshwater system” submitted to “Limnology and Oceanography: Methods.” This data is an extension of the River Corridor and Watershed Biogeochemistry SFA’s Spatial Study 2021 (https://doi.org/10.15485/1898914). Other associated data and field metadata can be found at the link provided. The goal of this manuscript is to assess the impact of solid phase extraction (SPE) on the ability to pair ultra-high resolution mass spectrometry data collected from SPE extracts with optical properties collected on ambient stream samples. Forty-seven samples collected from within the Yakima River Basin, Washington were analyzed dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC), absorbance, and fluorescence. Samples were subsequently concentrated with SPE and reanalyzed for each measurement. The extraction efficiency for the DOC and common optical indices were calculated. In addition, SPE samples were subject to ultra-high resolution mass spectrometry and compared with the ambient and SPE generated optical data. Finally, in addition to this cross-platform inter-comparison, we further performed and intra-comparison among the high-resolution mass spectrometry data to determine the impact of sample preparation on the interpretability of results. Here, the SPE samples were prepared at 40 milligrams per liter (mg/L) based on the known DOC extraction efficiency of the samples (ranging from ~30 to ~75%) compared to the common practice of assuming the DOC extraction efficiency of freshwater samples at 60%. This data package folder consists of one main data folder with one subfolder (Data_Input). The main data folder contains (1) readme; (2) data dictionary (dd); (3) file-level metadata (flmd); (4) final data summary output from processing script; and (5) the processing script. The R-markdown processing script (SPE_Manuscript_Rmarkdown_Data_Package.rmd) contains all code needed to reproduce manuscript statistics and figures (with the exception of that stated below). The Data_Input folder has two subfolders: (1) FTICR and (2) Optics. Additionally, the Data_Input folder contains dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data (SPS_NPOC_Summary.csv) and relevant supporting Solid Phase Extraction Volume information (SPS_SPE_Volumes.csv). Methods information for the optical and FTICR data is embedded in the header rows of SPS_EEMs_Methods.csv and SPS_FTICR_Methods.csv, respectively. In addition, the data dictionary (SPS_SPE_dd.csv), file level metadata (SPS_SPE_flmd.csv), and methods codes (SPS_SPE_Methods_codes.csv) are provided. The FTICR subfolder contains all raw FTICR data as well as instructions for processing. In addition, post processed FTICR molecular information (Processed_FTICRMS_Mol.csv) and sample data (Processed_FTICRMS_Data.csv) is provided that can be directly read into R with the associated R-markdown file. The Optics subfolder contains all Absorbance and Fluorescence Spectra. Fluorescence spectra have been blank corrected, inner filter corrected, and undergone scatter removal. In addition, this folder contains Matlab code used to make a portion of Figure 1 within the manuscript, derive various spectral parameters used within the manuscript, and used for parallel factor analysis (PARAFAC) modeling. Spectral indices (SPS_SpectralIndices.csv) and PARAFAC outputs (SPS_PARAFAC_Model_Loadings.csv and SPS_PARAFAC_Sample_Scores.csv) are directly read into the associated R-markdown file. We acknowledge the Yakama Nation as owners and caretakers of the lands where we collected some of these data. We thank the Confederated Tribes and Bands of the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate sample collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

Statistically-driven Experimental Design to Improve Reference-free Quantification of Small Molecules by Liquid Chromatography-Mass Spectrometry

Non-targeted analysis of small molecules and metabolites in unknown, complex samples using liquid chromatography-tandem mass spectrometry remains challenging. One of the main bottlenecks is the extensive unannotated regions of metabolomics mass spectrometry data, resulting in knowledge gaps. Small molecule annotation in mass spectrometry data has conventionally relied on reference standards and libraries for compound identification and confirmation, which can constrain compound identification to those molecules already known, thus limiting the ability to discover new knowledge and new markers. Retention time prediction can facilitate and expedite unknown compound identification in non-targeted analysis of complex metabolomics samples. Additionally, accurate retention time predictions can also inform sample mixture design for LC-MS/MS analyses. However, current machine learning-based methods for retention time prediction are typically developed for specific chromatographic platforms and are not generalizable across scales. And while technologies and methods to improve reference-free metabolite identification for more comprehensive annotation of unknowns has received much attention, development of the same for quantitation without reference standards has been much more limited, despite its importance in toxicological, environmental, food safety, forensics, and clinical applications. We believe that a reference-free quantitation strategy that exploits mass spectrometry data already collected for reference-free identification can provide much more insight on unknowns, and move the metabolomics field for more complete unknowns characterization. As such, we pursue two efforts to improve upon current state-of-the-art methods in non-targeted analysis: (1) machine learning-based retention time prediction and (2) statistical design of experiments framework for reference-free quantitation. In this work, we develop and demonstrate (1) a generalizable retention time prediction capability across chromatographic conditions and scales, and (2) a statistical design-based framework for response factor contribution elucidation and reference-free quantitation. Evaluation of our retention time prediction model, PrediToR, showed approximately 24% improvement over current models, and we observed approximately 10X improvement in concentration estimation accuracy from our statistical design-based response factor model over a primarily ionization efficiency-based model. We expect that future efforts to improve upon these new capabilities will further advance non-targeted analysis of small molecules towards truly reference-free metabolomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Internal Reaction Mass Taxonomy and Narrow-Down Study

Internal reaction mass (IRM) wave energy converters (WEC) capture wave energy by reacting against a moving mass that is suspended within their hulls. Due to their hermetically sealed Power Take Off (PTO), compact form factor and relatively simple mooring requirements, the National Renewable Energy Laboratory has identified IRM WECs are good candidates for applications such as ocean observation. A literature review of existing IRM mechanisms lead to the classification of IRM WECs based on their principal method of energy capture and principal axes of operation. The IRM categories include sliding mass, pendular and gyroscopic devices. A narrow down study was conducted to ascertain the most promising mechanisms for further investigation; devices were evaluated based on a decision matrix of weighted criteria that included device power output, prototypability and power to mass ratio. The narrow down study identified the issue of achieving resonance with pendulum-based designs, as well as the poor response produced by reaction to long period waves. Chaotic pendula and methods to multiply agitation were identified as a means to increase power output. Alternative methods of power generation, such as triboelectric nanogenerators, were also identified as a technology that would benefit from multiplied agitation and chaotic motion. This work was funded under the U.S. Department of Energy's Water Power Technologies Office's Powering the Blue Economy portfolio.

ENGINEERING,TIDAL AND WAVE POWER↗

Non-Contact Mass Density and Thermal Conductivity Measurements of Organic Thin Films Using Frequency–Domain Thermoreflectance

Thin-film organic materials are broadly used to study amorphous stabilization of active pharmaceuticals, control explosive detonation phenomena, and introduce insulation in novel thermal barriers. Their synthesis, however, introduces defects and thickness variations that warrant careful characterization of local thermophysical properties such as thermal conductivity and mass density. In this study, wide bandwidth (200 Hz to 20 MHz) frequency–domain thermoreflectance (FDTR) is demonstrated to simultaneously extract the thermal conductivity and mass density of 1 μm physical vapor-deposited indomethacin films on Si and SiO 2 substrates, as well as 10 and 100 μm films on Si. By assuming a bulk specific heat capacity, mass densities are determined with FDTR measurements of volumetric heat capacity and are in good agreement with the literature, as well as models based upon a dependence on porosity and the kinetic theory for phonons. Lastly, it is found that for broad-band FDTR measurements, insulating substrates provide improved fidelity for the extraction of thermal conductivity and volumetric heat capacity in organic thin films. Overall, this work demonstrates the potential for FDTR as a non-contact method to determine microscale mass density variations across the surface and thickness of organic thin films.

36 MATERIALS SCIENCE↗

Predicting High‐Resolution Spatial and Spectral Features in Mass Spectrometry Imaging with Machine Learning and Multimodal Data Fusion

Recent advancements in molecular Mass Spectrometry Imaging have sparked interest in integrating high spatial resolution methods with molecular mass-spectrometry-based chemical imaging. Fusion-based algorithms have proven effective in generating high spatial-resolution molecular mass spectra. However, a significant challenge stems from the differing physical mechanisms underlying image generation and data upsampling techniques, potentially leading to discrepancies in integrated information channels. Integrating physical constraints into data processing workflows is essential to tackle this issue. In this study, we propose an innovative approach that merges data from Fourier transform ion cyclotron resonance (FTICR), time-of-flight matrix-assisted laser desorption/ionization, and time-of-flight secondary ion mass spectrometry imaging techniques. By leveraging FT-ICR's unparalleled spectral resolution and ToF-SIMS's exceptional spatial resolution, we achieve submicron spatial resolution, enabling the observation of intact molecular species with remarkable spectral precision. Canonical correlation analysis is employed to incorporate physical constraints. Through sophisticated image processing and machine learning techniques, the results of this fusion hold significant promise for advancing our comprehension of complex systems and unveiling concealed molecular intricacies.

canonical correlation analysis↗

Advanced mass balance characterization and fractionation of algal biomass composition

Abstract Opportunities associated with biomass production and bioproduct isolation from algae-derived feedstocks are plentiful and promising; however, there are challenges associated with realizing these applications. One of the most important, and often overlooked, challenges is the lack of availability of a strong foundation of compositional analysis methods validated on microalgal biomass. Currently, compositional analysis in algae is dominated by the use of interference-prone methods, a lack of full mass balance accounting, and the use of top-down approaches that bin all unaccounted-for mass into a single category, such as carbohydrates. We present here an approach based on a bottom-up algal biomass characterization aimed at moving towards, and highlighting the importance of, full and accurate mass closure to achieve the maximum economic potential from a sustainable and renewable feedstock. Algal biomass representing three genera, Nannochloropsis , Scenedesmus , and Monoraphidium , was subjected to a cell rupture and fractionation process, followed by detailed characterization of each fraction to determine the partitioning of measured and unknown components. The goal of this work is to identify where the missing components partition, and develop a strategy to close the mass balance or identify the unknowns, while utilizing a rigorous characterization approach for characterizing algal biomass. Although only 75–80% of the biomass was accounted for, the fractionation approach utilized here provides key insight into possible chemical components for future investigations.

59 BASIC BIOLOGICAL SCIENCES↗

A mass-transfer particle-tracking method for simulating transport with discontinuous diffusion coefficients

The problem of a spatially discontinuous diffusion coefficient (D(x)) is one that may be encountered in hydrogeologic systems due to natural geological features or as a consequence of numerical discretization of flow properties. To date, mass-transfer particle-tracking (MTPT) methods, a family of Lagrangian methods in which diffusion is jointly simulated by random walk and diffusive mass transfers, have been unable to solve this problem. This manuscript presents a new mass-transfer (MT) algorithm that enables MTPT methods to accurately solve the problem of discontinuous D(x). To achieve this, we derive a semi-analytical solution to the discontinuous D(x) problem by employing a predictor-corrector approach, and we use this semi-analytical solution as the weighting function in a reformulated MT algorithm. Furthermore, this semi-analytical solution is generalized for cases with multiple 1D interfaces as well as for 2D cases, including a 2 × 2 tiling of 4 subdomains that corresponds to a numerically-generated diffusion field. The solutions generated by this new mass-transfer algorithm closely agree with an analytical 1D solution or, in more complicated cases, trusted numerical results, demonstrating the success of our proposed approach.

42 ENGINEERING↗

Mef2c regulates bone mass through Sost -dependent and -independent mechanisms

We report Mef2c is a transcription factor that mediates key cellular behaviors that promote endochondral ossification and bone formation. Previously, Mef2c has been shown to regulate Sost transcription via its osteocyte-specific enhancer, ECR5, and conditional deletions of Mef2 cfl/fl with either Col1-Cre or Dmp1-Cre produced generalized high bone mass (HBM) consistent with Van Buchem Disease phenotypes. However, Sost -/- ; Mef2 cfl/fl ; Dmp1-Cre mice produced a significantly higher bone mass phenotype that Sost-/- alone suggesting that Mef2c modulates bone mass through additional mechanisms, independent of Sost. To identify new Mef2c transcriptional targets important in bone metabolism, we profiled gene expression by single-cell RNA sequencing in subpopulations of cells isolated from Mef2 cfl/fl ; Dmp1-Cre and Mef2 cfl/fl ; Bglap-Cre femurs, both strains exhibiting similar high bone mass phenotypes. However, we found Mef2cfl/fl; Bglap-Cre to also display a growth plate defect characterized by an expansion of several osteoprogenitor subpopulations. Differential gene expression analysis identified a total of 96 up- and 2434 down- regulated genes in Mef2 cfl/fl ; Bglap-Cre and 176 up- and 1041 down- regulated genes in Mef2 cfl/fl ; Dmp1-Cre bone cell subpopulations compared to wildtype mice. Mef2c deletion affected the transcriptomes across several cell types including mesenchymal progenitors (MP), osteoprogenitors (OSP), osteoblast (OB), and osteocyte (OCY) subpopulations. Several energy metabolism genes such as Uqcrb, Ndufv2, Ndufs3, Ndufa13, Ndufb9, Ndufb5, Cox6a1, Cox5a, Atp5o, Atp5g2, Atp5b, Atp5 were significantly down regulated in Mef2c-deficient OBs and OCYs, in both strains. Binding motif analysis of promoter regions of differentially expressed genes identified Mef2c binding in Bone Sialoprotein (BSP/Ibsp), a gene known to cause increased trabecular BV/TV in the femurs of Ibsp -/- mice. Immunohistochemical analysis confirmed the absence of Ibsp protein in OBs and OCYs. These findings suggests that the HBM in Sost -/- ; Mef2 cfl/fl ; Dmp1-Cre is caused by a multitude of transcriptional changes in genes that regulate bone formation, two of which are Sost and Ibsp.

59 BASIC BIOLOGICAL SCIENCES↗

Comparison of thermionic filament and carbon nanotube field emitter-based electron ionization sources in cycloidal coded aperture mass analyzers

This report compares the coded aperture imaging performance of thermionic filament and carbon nanotube (CNT) field emitter-based electron sources in cycloidal-coded aperture mass spectrometers. The use of spatially coded apertures in mass spectrometry enables miniaturization by improving throughput without sacrificing resolution. CNT-based electron ionization sources for mass spectrometers provide several potential benefits over conventional thermionic emitters, including low voltage and low power consumption, room temperature operation, long lifetime, and ability to emit electrons in a pulsed mode. However, spatiotemporal variation in electron emission from CNTs is a major disadvantage. In this study, electron emission stability and spatiotemporal stability of the coded aperture image were compared for coded aperture cycloidal mass analyzers with either a CNT-based ion source or a thermionic filament-based ion source. We found that the thermionic filament-based ion source produced a significantly more stable coded aperture image than the CNT based ion source. The aperture image fluctuations in the CNT-based source are likely a result of adsorption and desorption of molecules on the CNT surface that cause local work function changes and induce spatiotemporal variation in electron emission and subsequent ion generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamic mass accountancy modeling of a molten salt reactor using equilibrium thermodynamics

A mechanistic-based mass accountancy model in the context of liquid-fueled molten salt reactors was implemented in the dynamic systems modeling software library TRANSFORM by way of coupling with the equilibrium thermodynamics code Thermochimica. Liquid-fueled molten salt reactors present new challenges for mass accountancy because of the dissolution of fuel and evolved fission products, which may be soluble in the salt, off-gas, or precipitate. Two cases of mass loss from the molten salt were addressed: off-gassing and precipitation. The software implementation was tested through a series of increasingly complex demonstration problems, culminating in a model of the primary fuel and primary coolant loops of the molten salt demonstration reactor. Analysis shows that negligible mass was lost from the salt under normal operating conditions, but an overheating event caused by partial loss of fuel loop cooling resulted in release of measurable amounts of uranium (among other elements) via off-gassing. The tools developed here are primarily aimed at capability development but are readily available for use in further modeling of molten salt reactor concepts. As a result, these tools have not yet been validated, and future experimental work to perform this validation is recommended.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Insights into the emergence of mass from studies of pion and kaon structure

There are two mass generating mechanisms in the standard model of particle physics (SM). One is related to the Higgs boson and fairly well understood. The other is embedded in quantum chromodynamics (QCD), the SM’s strong interaction piece; and although responsible for emergence of the roughly 1 GeV mass scale that characterises the proton and hence all observable matter, the source and impacts of this emergent hadronic mass (EHM) remain puzzling. As bound states seeded by a valence-quark and -antiquark, pseudoscalar mesons present a simpler problem in quantum field theory than that associated with the nucleon. Consequently, there is a large array of robust predictions for pion and kaon properties whose empirical validation will provide a clear window onto many effects of both mass generating mechanisms and the constructive interference between them. This has now become significant because new-era experimental facilities, in operation, construction, or planning, are capable of conducting such tests and thereby contributing greatly to resolving the puzzles of EHM. These aspects of experiment, phenomenology, and theory, along with contemporary successes and challenges, are reviewed herein. In addition to providing an overview of the experimental status, we focus on recent progress made using continuum Schwinger function methods and lattice-regularised QCD. Further, advances made using other theoretical tools are also sketched. Our primary goal is to highlight the potential gains that can accrue from a coherent effort aimed at finally reaching an understanding of the character and structure of Nature’s Nambu–Goldstone modes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Online detection of airborne nanoparticle composition with mass spectrometry: Recent advances, challenges, and opportunities

Airborne nanoparticles are receiving growing attention due to their impacts on human health, air quality, and climate. Additionally, there are increasing applications of aerosol-based nanotechnology. Real-time measurement of airborne nanoparticle composition is challenging due to their small masses and the difficulties in effectively separating them from larger particles. Custom-built instruments based on mass spectrometry have been developed for nanoparticle composition, including thermal desorption-based, laser-based, and solution-based techniques. They have significantly promoted the understanding of airborne nanoparticles in the last two decades. However, they are affected by molecular fragmentation, lack of mass-resolving power, incomplete species detection, and difficulties in directly comparing to gas-phase measurements. Recent developments in atmospheric mass spectrometry provide possible solutions. Here, this review presents the potential application of these new advances to real-time measurements of the molecular nanoparticle composition and discusses the associated challenges. Such measurements present opportunities for a more comprehensive view of airborne nanoparticles and their impacts.

47 OTHER INSTRUMENTATION↗

Assessing the Impact of Measurement Precision on Metabolite Identification Probability in Multidimensional Mass Spectrometry-Based, Reference-Free Metabolomics

Identification of compounds with minimal ambiguity remains a central challenge in mass spectrometry-based metabolomics. Conventional compound identification relies on comparing analytical signatures (e.g., mass-to-charge ratio, collision cross section, tandem mass spectra) against reference data obtained from measurements of authentic chemical standards. The breadth of annotatable compounds using this approach is necessarily limited by availability of authentic standards, analytical throughput, and resolving power of the separations that underly the measurements. The maturation of computational methods, both theory-driven and artificial intelligence/machine learning-based, for prediction of various molecular properties relevant to multidimensional mass spectrometry measurements has opened the door to a new “reference-free” paradigm of compound annotation. Through augmenting existing reference data for molecular properties with computational predictions, the universe of identifiable chemical species can be expanded significantly beyond its current limits. An unexplored aspect of this novel approach is understanding how to gauge confidence in resulting annotations, especially as the compound search space is expanded. Intuitively, the confidence of a compound annotation is related to the inherent discriminatory power of the molecular properties used for identification, as well as the precision with which the properties are measured or predicted. In this work, we characterize this relationship between measurement precision and identification probability in a systematic and quantitative fashion for a defined region of chemical space that includes organic small molecule metabolites. Importantly, this work establishes a framework for conducting metabolite identification probability analysis that enables others to quantify this relationship for their own compounds and properties of interest.

Metabolite Identification↗

DEIMoS GUI: An Open-Source User Interface for a High-Dimensional Mass Spectrometry Data Processing Tool

In this paper, we report the creation of a graphical user interface (GUI) for the Data Extraction for Integrated Multidimensional Spectrometry (DEIMoS) tool. DEIMoS is a Python package to process data from high-dimensional mass spectrometry measurements. It is divided into several modules, each representing a data processing step, such as peak detection, alignment, and tandem mass spectra extraction and deconvolution. The inputs for and outputs from DEIMoS can include millions of N-dimensional data points, which can be challenging to visualize in a way that is interactive, informative, and responsive. Here, we used the HoloViz Python data stack, including DataShader and Param, to create an interactive visualization of mass spectrometry data. We believe the GUI will increase the accessibility of DEIMoS, and the visualization methods could be useful for other open-source mass spectrometry tools.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗