Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loading frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder

Owing to the increased use of power electronic based appliances and energy-efficient home equipment such as modern lighting loads, the percentage of nonlinear loads has increased in the distribution system, which can impact system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determination of possible interactions at harmonic frequencies, protection planning, and the effect of system impedance. This paper focuses on harmonic load flow analysis for multiple residential load types to determine the expected impacts on an modeled distribution secondary. For this study, the household appliances include lighting, power electronic, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split phase at a nominal frequency of 60 Hz. The harmonic spectrums, as obtained from the experimental evaluation of real loads, are used to inform the harmonic load flow for a detailed secondary network, including the distribution service transformer extracted from a real distribution feeder's model. Additionally, the impact of voltage harmonics on a three-phase test load is presented with experimental results. The harmonic data of the transformer terminal voltage, as obtained from the former load flow study, are scaled to generate the source voltage for the three-phase configuration of the grid simulator to make the test setup very similar to a typical secondary design in the U.S.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Ultrasonic measurement of axial stress

The theory of acoustic propagation in strained media is examined, with particular emphasis on rod (bolt) geometries. The continuous wave (CW) approach is the basis of the study, and the theory is developed from a frequency domain analysis standpoint in order to obtain an applied stress/normalized frequency shift relationship. CW measurements may be influenced by such factors as propagation effects, mode conversion, frequency, material properties, and geometry. After the first loading cycle, axial stress measurements for a preloading with an initial frequency of 4.995 36 MHz dropped to 4.989 19 MHz, indicating a 6.17 kHz change. CW and pseudo-CW ultrasonic techniques are found to be reliable for axial stress measurements, and acoustic attenuation measurements correlated to residual stress fields may possibly involve transducer phase cancellation. It is thus concluded that signal drop is an artifact of the transducer directivity, rather than an actual acoustic power decrease.

Heyman, J. S.↗

Stability, vibration and passive damping of partially restrained imperfect columns

A theoretical and experimental study of slender tubular columns for possible use in space structures is conducted in the presence of partial rotational end restraints. Explicit formulas are derived for computing the buckling load and the lowest natural frequency of perfectly straight uniform elastic members with rotational end restraints possessing linear moment-rotation characteristics. An exact solution in the form of a transcendental equation, and a numerical solution using second-order finite-differences are also presented. The presence of an initial imperfection is also incorporated into the numerical procedure. Vibration tests are conducted on an imperfect tubular steel member in the absence of an axial load. A damping concept consisting of a string-mass assembly is explored. Three passive damping configurations involving combinations of three lead shots were investigated. The three lead shot configurations provided considerably greater damping than the single lead shot.

Razzaq, Z.↗

Flight Test Identification and Simulation of a UH-60A Helicopter and Slung Load

Helicopter slung-load operations are common in both military and civil contexts. Helicopters and loads are often qualified for these operations by means of flight tests, which can be expensive and time consuming. There is significant potential to reduce such costs both through revisions in flight-test methods and by using validated simulation models. To these ends, flight tests were conducted at Moffett Field to demonstrate the identification of key dynamic parameters during flight tests (aircraft stability margins and handling-qualities parameters, and load pendulum stability), and to accumulate a data base for simulation development and validation. The test aircraft was a UH-60A Black Hawk, and the primary test load was an instrumented 8- by 6- by 6-ft cargo container. Tests were focused on the lateral and longitudinal axes, which are the axes most affected by the load pendulum modes in the frequency range of interest for handling qualities; tests were conducted at airspeeds from hover to 80 knots. Using telemetered data, the dynamic parameters were evaluated in near real time after each test airspeed and before clearing the aircraft to the next test point. These computations were completed in under 1 min. A simulation model was implemented by integrating an advanced model of the UH-60A aerodynamics, dynamic equations for the two-body slung-load system, and load static aerodynamics obtained from wind-tunnel measurements. Comparisons with flight data for the helicopter alone and with a slung load showed good overall agreement for all parameters and test points; however, unmodeled secondary dynamic losses around 2 Hz were found in the helicopter model and they resulted in conservative stability margin estimates.

Cicolani, Luigi S.↗

Distributed Automatic Generation Control Considering DPV Using T&D Dynamic Co-Simulation

The increasing adoption of distributed energy resources (DERs) over the last decade warrants a reconsideration of control of generation resources. This paper proposes a distributed Automatic Generation Control (AGC) using transmission-and-distribution (T&D) dynamic co-simulation framework for the efficient DPV frequency regulation services. The co-simulation framework allows AGC units to exchange the information for distributed AGC, based on their adopted communication network topology. As a result, a cost-effective automatic generation control is achieved with DPV and conventional generators. The proposed distributed AGC is based on the gossip algorithm in which the neighboring AGC units share the relevant local information with each other and updates their share of AGC regulation signal. Distributed photovoltaics (DPV) unit contribute to AGC response based on their headroom capacity via DER aggregators. The algorithm is tested on IEEE-14 bus transmission system under conditions of generation failure and random load variation to observe effective frequency regulations service offered by DPVs and other AGC units. The study shows that DPV can effectively participate in AGC with the proposed distributed control framework.

automatic generation control↗

Ultra-stable oscillator with complementary transistors

A high frequency oscillator, having both good short and long term stability, is formed by including a piezoelectric crystal in the base circuit of a first bi-polar transistor circuit, the bi-polar transistor itself operated below its transitional frequency and having its emitter load chosen so that the input impedance, looking into the base thereof, exhibits a negative resistance in parallel with a capacitive reactance. Combined with this basic circuit is an auxiliary, complementary, second bi-polar transistor circuit of the same form with the piezoelectric crystal being common to both circuits. By this configuration small changes in quiescent current are substantially cancelled by opposite variations in the second bi-polar transistor circuit, thereby achieving from the oscillator a signal having its frequency of oscillation stable over long time periods as well as short time periods.

Kleinberg, L. L.↗

Improved estimation of random vibration loads in launch vehicles

Random vibration induced load is an important component of the total design load environment for payload and launch vehicle components and their support structures. The current approach to random vibration load estimation is based, particularly at the preliminary design stage, on the use of Miles' equation which assumes a single degree-of-freedom (DOF) system and white noise excitation. This paper examines the implications of the use of multi-DOF system models and response calculation based on numerical integration using the actual excitation spectra for random vibration load estimation. The analytical study presented considers a two-DOF system and brings out the effects of modal mass, damping and frequency ratios on the random vibration load factor. The results indicate that load estimates based on the Miles' equation can be significantly different from the more accurate estimates based on multi-DOF models.

Mehta, R.↗

Analysis of 7- X 10-foot high speed wind tunnel shaft loads in support of fan blade failure investigation

This is a report of the investigation of the High-Speed 7- X 10-Foot Wind Tunnel at NASA Langley Research Center, which experienced a catastrophic failure of all 18 Sitka spruce fan blades during operation at 0.8 Mach number on 2 July 1985. The High-Speed Tunnel, a closed-circuit/single-return atmospheric wind tunnel, had been operated since 1945 to support a wide range of subsonic aerodynamic tests and studies. The failed blade set had been in use since 1975. In addition to blade loss, the most significant damage was a bent main drive shaft for a total estimated damage loss of 1.7 million dollars. An analysis of the natural frequency characteristics as well as loads, reactions, stresses, and deflections of the fan drive system resulting from steady-state and dynamic loads due to unbalance was performed. Transient load cases were simulated by step input and ramp input loading functions intended to simulate the loss of one to nine blades (maximum unbalance forces).

Faison, Richard W.↗

A novel post-processing method for progressive failure analysis of brittle composite compression

Finite element analysis of brittle materials in axial compression typically uses element deletion to allow continued global deformation post-element-failure. However, element deletion produces cyclic load-displacement curves that underestimate energy absorption and are not representative of a continuum system. Two key observations support the conclusion that results from an appropriately discretized model can be an adequate representation of a continuum system. Specifically, the frequency of the oscillations in the load-displacement curve is directly dependent upon element length in the loading direction, and the peak amplitudes of oscillations are mesh size independent. A method of post-processing the analysis results, by connecting the peak amplitudes of oscillations, is proposed and applied to a series of continuous carbon fiber composite crush tubes. The load-displacement curve, stable crushing load, and specific energy absorption of the post-processed results compare well to an experimental study of crush tubes with similar layups.

Materials Science↗

Unijunction frequency divider.

Frequency divider using unijunction transistors, each stage relaxation oscillator designed to reduce backward loading to minimum

UNIPOLAR TRANSISTOR↗

Proactive Frequency Stability Scheme via Bayesian Filters and Synchrophasors

Underfrequency (UF) load shedding schemes are traditionally implemented in two ways: One approach is based on manual load shedding, with system operators requesting loads to be shed ahead of anticipated stressful operating conditions. Manual load shedding is usually done through phone calls. The second method is automatic load shedding via underfrequency relays. Using static static settings, these schemes can be designed to operate in stages and drop previously identified loads. The main limitation of traditional load shedding schemes is that they are reactive and leave little room for optimized corrective actions. This work presents a proactive and automatic underfrequency load shedding solution for power systems. Measurements are captured via phasor measurement units (PMUs) at relatively low sampling rates of 30 Hz. These measurements are then processed by particle filters who predict the future state of the system's frequency. Based on these predictions excess load is determined and shed. Comparative case studies are performed in simulated environments. Easy-to-implement models, without hard-to-derive parameters, highlight potential aspects for real-life implementation.

Paramo, Gian↗

Analysis of Exercise Loads to Inform Vibration Isolation System Design

BACKGROUND: This study was conducted with the primary interest of providing data that would inform Vibration Isolation and Stabilization (VIS) system design and performance for the European Enhanced Exploration Exercise Device (E4D). In preparation for the International Space Station (ISS) in-flight demonstration, a list of critical Human Health Countermeasures (HHC) exercises was compiled [1]. The goal of this study was to assess the ground reaction forces and moments imposed by an exercising subject in each of the six VIS Degrees of Freedom (DOFs) during a comprehensive set of these critical exercises performed on the E4D. METHODS AND RESULTS: The ISS in-flight demonstration list of critical exercises included seated aerobic rowing, bent-over rowing, cycling, front squats, back squats, conventional deadlifts, Romanian deadlifts, heel raises, overhead presses, reverse chops, and power clean presses. At the NASA Johnson Space Center (JSC) Prototype Immersive Technology (PIT) laboratory, motion capture data were collected on critical E4D exercises for six subjects. At the NASA JSC Active Response Gravity Offload System (ARGOS) facility, additional motion capture and load cell data were collected on offloaded trials for four subjects. Select data were extrapolated to represent a 5th percentile female subject and a 95th percentile male subject. A previous investigation comparing the forces obtained from the load cell and from motion capture based data found a satisfactory level of agreement between the two measurements [2]. The motion capture based data were analyzed for this study since it is driven by the subject’s trajectory alone, automatically excluding any forces exerted on the subject by the ARGOS offloading harness. The OpenSim [3, 4] biomechanical simulation inverse kinematics tool was used to calculate the joint angles based on the locations of motion capture markers placed at key positions on the subject’s body. An OpenSim plugin was then used to obtain the forces and moments generated by the subject during each trial, with the moments computed relative to the equilibrium location of the subject’s feet [5]. The force of gravity was also removed to simulate the loads generated by the exercise when performed in microgravity. The load plots for each trial were generated and visually analyzed to obtain the magnitudes of the peak loads for each exercise in each DOF. The typical period of exercise for each trial was also estimated and used to calculate the frequency for each trial. The exercise loads data was then organized in multiple ways to capture different aspects of the data. As a result of this study, we present a summary of the load magnitudes observed during these critical exercises utilizing the E4D.

C A Bell↗

Effect of airfoil mean loading on convected gust interaction noise

The present theoretical model for noise generation when a convected vortical or entropic gust encounters an airfoil at a nonzero angle-of-attack is based on a linearization of the Euler equations for the steady, subsonic flow past the airfoil. Noise generation is found to be concentrated at local regions which scale on the gust wavelength and are present at airfoil leading and trailing edges. Steady loading of the airfoil affects noise generation at the leading and trailing edges in significantly different ways. Parametric calculations are presented which illustrate that, at high frequencies, moderate levels of airfoil steady loading can drastically increase the noise level produced by airfoil-convected gust interactions.

Myers, M. R.↗

Harmonic Modeling, Data Generation and Analysis of Power Electronics-Interfaced Residential Loads

The share of electronics-based residential load is expected to rise as devices such as variable frequency drives (VFDs), electric vehicle chargers, and inverter-based distributed energy resources (DERs), e.g., photovoltaic (PV) systems become more common. These loads may introduce significant harmonics into power networks that need to be closely studied in order to perform accurate load modeling and forecasting. However, it can be difficult to obtain harmonic-rich voltage and current data - necessary for identifying accurate load models - for residential electrical loads. Recognizing this need, we identify and model a set of electronics-based end-use loads and DERs in an electromagnetic transients program (EMTP) tool for a residence with a single- phase split-phase supply. Further, a procedure is developed to model harmonic interactions between end-use loads connected to the same non-ideal supply voltage in a residential setting. Finally, a harmonic-rich dataset produced via the proposed procedure is utilized to identify frequency coupling matrix (FCM) based load model. Numerical results demonstrate the accuracy of the model, and explore model identifiability with limited data points.

harmonics, power quality, load modeling↗

Capability of Impedance Measurement Using Spread Spectrum Time-Domain Reflectometry

Spread spectrum time-domain reflectometry (SSTDR) has been proposed for measuring electrical impedance on live, energized systems, in electrically noisy environments, or for measuring multiple channels simultaneously. Here we evaluate the capability of SSTDR for impedance measurement from near dc to 96 MHz and find that they agree very well with measurements from a vector network analyzer (VNA). Time gating is used to remove (calibrate out) transmission line effects. We evaluate the frequency ranges over which SSTDR at different modulation frequencies is accurate for the measurement of series resistive–capacitive ( RC ) loads and observe that fusing measurements from multiple modulation frequencies can broaden the effective measurement bandwidth.

14 SOLAR ENERGY↗

Scaling up carboxylic acid production from cheese whey and brewery wastewater via methane-arrested anaerobic digestion

In a circular economy, organic waste streams are valuable resources for sustainably producing chemicals and fuels. This study investigates a new methane-arrested anaerobic digestion (MAAD) process that converts high-strength cheese whey and brewery wastewater into carboxylic acids. The process was developed and optimized under various bench-scale semi-continuous (fed-batch) operating conditions (e.g., retention time, organic loading rate, pH, and feed/harvest frequency). The MAAD responses to various control-failure scenarios were also systematically investigated. The highest total acid productivity was 26g/(L liq ·d) with a substrate conversion of 0.79g COD digested /g COD fed at a hydraulic retention time (HRT) of approximately 2 d in a 14-L digester. The most stable conditions for digester operation (HRT 3 d at pH 6.0 and 40°C) were selected for process scale-up to 100gal (~380 L). Semi-continuous, pilot-scale MAAD successfully produced a total acid concentration of 40.6+/-1.1 g/L with 8.1% acetic acid, 45.1% butyric acid, and 44.5% lactic acid. The links between wastewater characteristics, operation mode, digester scale, and microbial community structure were statistically analyzed. The results show genera Sporolactobacillus and Clostridium positively correlate with butyric acid production (Pearson correlation coefficient>0.5). Moreover, four kinetic models were developed and fit to batch MAAD experimental datasets (R 2 >95%) and were successfully applied to predict the total acid production in both bench-and pilot-scale semi-continuous MAADs. In conclusion, this study shows MAAD has the potential for industrial-scale applications and is a robust platform to valorize low- or negative-value waste streams into high-value bioproducts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the fatigue crack growth behavior of Ti–10V–2Fe–3Al in gaseous hydrogen

Here, the fatigue crack growth behavior of Ti–10V–2Fe–3Al in gaseous hydrogen (H 2 ) was assessed through comparative experiments conducted in laboratory air and 8.3 MPa H 2 . The measured fatigue crack growth rate (da/dN) versus applied stress intensity factor range (ΔK) relationships and observed fracture morphologies for laboratory air and H 2 were comparable up to ΔK ≈ 6.9 MPa√m, when tested at a load ratio of 0.1 and frequency of 10 Hz. At higher ΔK values, significant crack deflection and subsequent catastrophic failure occurred in the specimen tested in H 2 . This degradation was not observed in a specimen pre-exposed to 8.3 MPa H 2 for 96 h and then immediately tested in laboratory air. X-ray diffraction of the failed H 2 -tested specimen revealed that the material remnants were predominantly composed of TiH 2 , suggesting that hydride formation was the catalyst for catastrophic failure in H 2 . The mechanistic implications of these results and their impact on current material compatibility assessments for Ti alloys in hydrogen service are then discussed.

08 HYDROGEN↗

A Comparison of PV Resource Modeling for Sizing Microgrid Components

Microgrid systems are being deployed with increased frequency to meet critical building loads during unplanned power outages. Determining the appropriate type and size of components that make up a microgrid can greatly affect its ability to meet this need. This paper presents a new tool to appropriately size PV, battery, and generator capacities to meet all site loads, given a resilience goal. It uses a statistical model to simulate microgrid behavior under a large range of solar resource conditions, providing resilience planners with confidence that critical loads will be met even under extreme weather conditions. We compare this model with one that uses typical weather data for sizing microgrids, and quantify the resilience effects of using these different methods. Our method produces more conservative generator capacities and fuel requirements in an outage, predicting up to 30% more fuel required in the most extreme case. Microgrid systems that are designed using more conservative estimates are more likely to continue to serve load during emergency outages under a large range of conditions.

Newman, Sarah F.↗