Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Development of Packaging and Modular Control of Thermoelectric Clothes Dryer, With Performance Evaluation

This paper provides an overview of a thermoelectric heat pump clothes dryer which was developed with the aim of reducing the significant primary energy consumption attributed to residential electric clothes drying in the United States (623 TBtu/yr). The use of thermoelectric modules in place of the conventional electric resistance heater resulted in a 40% reduction in the energy consumption of the system, compared to the minimum energy efficiency standard. This was achieved for the first time for a standard test load of 8.45 lb, using a clothes dryer prototype with a thermoelectric heat pump module as the sole heating mechanism. The current experimental prototype was developed after extensive modeling, system design and control optimization, and experimental system-level evaluation of control parameters. The demonstration of improved energy consumption has laid the foundation for future development of this technology.

Patel, Viral↗

Design of a Transport System for the PIP-II HB650 Cryomodule

The PIP-II Project at FNAL requires the assembly of 3 high-beta 650MHz cryomodules at STFC Daresbury (DL) in the UK. These modules must be safely transported from DL to FNAL in the USA. Previous experience with cryomodule transport was leveraged at both labs to design a transport system to protect the cryomodules during transit. Requirements for the system included mitigation of shocks, drops, and vibrations, and acting as a lifting fixture. It is comprised of a tessellated steel frame which encompasses the module with a wire rope isolator arrangement which the module mounts to. The frame was designed to withstand the weight of the 12.5 tonne cryomodule in various load cases. Details of shock and vibration profiles were obtained from MIL-STD-810H and were used to guide the sizing of the isolators. The frame and the isolation system were analysed via FEA using the shock and vibration profiles as an input. The transport system was found to be suitable for the given isolation, frame stiffness, and lifting code requirements. The frame has been fabricated and successfully load tested at FNAL. It will now be road tested with a dummy cryomodule before undergoing a trial run to DL.

43 PARTICLE ACCELERATORS↗

Crack-Free Joining of High-Strength AA7055 Sheets by Friction Based Self-Piercing Riveting with the Aid of Numerical Design

Unique friction-based self-piercing riveting (F-SPR) was employed to join high-strength, low-ductility aluminum alloy 7055 for lightweight vehicle applications. This study aimed to maximize the joint strength of the AA7055 F-SPR joint while avoiding cracking issues due to low ductility at room temperature. A fully coupled Eulerian–Lagrangian (CEL) model was employed to predict the process temperature during F-SPR, and the temperature field was then mapped onto a 2D axisymmetric equivalent model for accelerated numerical analysis. The geometry, dimensions, and material strength of the rivet, as well as the depth of the die cavity and plunging depth, were investigated to enhance joint formation. Also, a static finite-element analysis model was developed to predict and analyze the stress distribution in the rivet under different mechanical testing loading conditions. Overall, the numerical model showed good agreement with the experiment results, such as joint formation and mechanical joint strength. With the aid of virtual fabrication through numerical modeling, the joint design iterations and process development time of F-SPR were greatly reduced regarding the goal of lightweight, high-strength aluminum joining.

36 MATERIALS SCIENCE↗

Effect of lubricant oil properties on the performance of gasoline particulate filter (GPF)

Mobile source emissions standards are becoming more stringent and particulate emissions from gasoline direct injection (GDI) engines represent a particular challenge. Gasoline particulate filter (GPF) is deemed as one possible technical solution for particulate emissions reduction. In this work, a study was conducted on eight formulations of lubricants to determine their effect on GDI engine particulate emissions and GPF performance. Accelerated ash loading tests were conducted on a 2.4L GDI engine with engine oil injection in gasoline fuel by 2%. The matrix of eight formulations was designed with changing levels of sulfated ash (SASH) level, Zinc dialkyldithiophosphates (ZDDP) level and detergent type. Comprehensive evaluations of particulates included mass, number, size distribution, composition, morphology and soot oxidation properties. GPF performance was assessed through filtration efficiency, back pressure and morphology. It was determined that oil formulation affects the particulate emission characteristics and subsequent GPF performance.

Shao, Huifang↗

Performance, Combustion and Emissions Evaluation of Liquid Phase Port-Injected LPG on a Single Cylinder Heavy-Duty Spark Ignited Engine

Liquefied petroleum gas (LPG), like many other alternative fuels, has witnessed increased adoption in the last decade, and its use is projected to rise as stricter emissions regulations continue to be applied. However, much of its use is limited to dual fuel applications, gaseous phase injection, light-duty passenger vehicle applications, or scenarios that require conversion from gasoline engines. Therefore, to address these limitations and discover the most efficient means of harnessing its full potential, more research is required in the development of optimized fuel injection equipment for liquid port and direct injection, along with the implementation of advanced combustion strategies that will improve its thermal efficiency to the levels of conventional fuels. This paper focuses on the development of a liquid phase port-injection system for LPG, the design of a reference piston, and the baseline evaluation of the performance, combustion, and emissions characteristics of a single cylinder research engine to establish a benchmark comparable to existing LPG engines. A sweep of start of injection (SOI) timing is performed by injecting liquid LPG at several closed and open intake valve timings, which demonstrates no significant variation in engine performance, but accounts for a 10% reduction in bsCO with the optimal SOI timing. Spark timing sweep demonstrates the 50% burn crank angle location related to maximum brake torque (MBT) point with a brake thermal efficiency (BTE) of ~34% for the tested load case. The effect of equivalence ratio is also presented with optimal SOI timing at MBT condition. The engine starts exhibiting knocking combustion at 140kPa intake manifold air pressure (IMAP) with a peak torque of 253Nm and a 5% reduction in brake specific fuel consumption compared to the naturally aspirated scenario.

Fosudo, Toluwalase↗

Flaw Growth of 6Al-4V Titanium in a Freon TF Environment

The plane strain threshold stress intensity and sustained stress flaw growth rates were experimentally determined for 6AI-4V S.T.A. titanium forging and weldments in environments of Freon TF at room temperature. Sustained load tests of surface flawed specimens were conducted with the experimental approach based on linear elastic fracture mechanics. It was concluded that sustained stress flaw growth rates, in conjunction with threshold stress intensities, can be used in assessing the service life of pressure vessels.

Tiffany, C. F.↗

Cable insulation cut-through tester

Device accurately measures cut-through load within specified time or time when cut-through occurs at specific load. Tests are performed at ambient conditions or in an environmental chamber.

Campbell, E. C.↗

Use of thin plastic films at cryogenic temperatures

Commercially available plastic film materials that remain flexible at cryogenic temperatures and resist failures caused by folds and wrinkles created during expulsion were investigated for use in expulsion bladders for liquefied gases. Compatible adhesive systems, fabrication techniques, and results of impact and dynamic loading tests are summarized.

Lark, R. F.↗

Comparison of NASTRAN and STARDYNE static analysis of a graphite fiber reinforced plastic truss structure

A static and buckling analysis of the ATS-F&G spacecraft reflector support truss (RST) and bridge truss assembly using NASTRAN was conducted. The RST is fabricated from a new material, graphite fiber reinforced plastic. A comparison is made with the NASTRAN results and the results of a similar analysis conducted using the stardyne program. The results of an actual static load test are also compared.

Honeycutt, G. H.↗