Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lasers sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Spatially resolved measurements of electron density of a magnetically confined split-ring resonator source

Laser-collisional induced fluorescence is used to study the plasma generated by a split-ring resonator discharge under an external cusp shaped magnetic field created by permanent magnets. The electron density and electron temperature are measured for a helium plasma at different pressures, powers, and magnet field strengths. It is found that the magnetic fields produce higher electron temperatures with peak temperatures of ∼3 eV, while the no magnet case has peak temperatures of ∼0.8 eV. Conversely, the peak electron density is obtained in the no magnet case at a value of ∼1.9 × 1011 cm−3. This indicates that the cusp-field did magnetize the electrons, but contrary to expectations, it resulted in a decrease in electron density. This is believed to be due to the magnetic field having negative effects on the resonance of the plasma source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a bright MeV photon source with compound parabolic concentrator targets on the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser

Compound parabolic concentrator (CPC) targets are utilized at the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser to enhance the acceleration of electrons and production of high energy photons, for laser durations of 10 ps and energies up to 2.4 kJ. A large enhancement of mean electron energy (>2 ×) and photon brightness (>10×) is found with CPC targets compared to flat targets. Using multiple diagnostic techniques at different spatial locations and scaling by gold activation spatial data, photon spectra are characterized for E photon = 0.5-30 MeV. Beam width and pointing variations are given. The efficient production of MeV photons at I laser ≈ 2 x 10 18 W/cm 2 with CPCs is observed, with doses of >10 rad in air at 1 m for E photon > 0.5 MeV; these exceed those previously reported with laser-driven sources. Using this source, sub-mm resolution radiographs are generated through large areal density radiograph objects. Hence these results are promising for the development of bright MeV x-ray and particle sources on Petawatt class laser systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical Profilometers Using Adaptive Signal Processing

A method of adaptive signal processing has been proposed as the basis of a new generation of interferometric optical profilometers for measuring surfaces. The proposed profilometers would be portable, hand-held units. Sizes could be thus reduced because the adaptive-signal-processing method would make it possible to substitute lower-power coherent light sources (e.g., laser diodes) for white light sources and would eliminate the need for most of the optical components of current white-light profilometers. The adaptive-signal-processing method would make it possible to attain scanning ranges of the order of decimeters in the proposed profilometers.

Hall, Gregory A.↗

Diffraction enhanced imaging utilizing a laser produced x-ray source

Image formation by Fresnel diffraction utilizes both absorption and phase-contrast to measure electron density profiles. The low spatial and spectral coherence requirements allow the technique to be performed with a laser-produced x-ray source coupled with a narrow slit. This makes it an excellent candidate for probing interfaces between materials at extreme conditions, which can only be generated at large-scale laser or pulsed power facilities. Here, we present the results from a proof-of-principle experiment demonstrating an effective ~2 μm laser-generated source at the OMEGA Laser Facility. This was achieved using slits of 1 × 30 μm 2 and 2 × 40 μm 2 geometry, which were milled into 30 μm thick Ta plates. Combining these slits with a vanadium He-like 5.2 keV source created a 1D imaging system capable of micrometer-scale resolution. The principal obstacles to achieving an effective 1 μm source are the slit tilt and taper—where the use of a tapered slit is necessary to increase the alignment tolerance. We demonstrate an effective source size by imaging a 2 ± 0.2 μm radius tungsten wire.

3D printing↗

Gamma-ray spectroscopy using angular distribution of Compton scattering

We present a novel method to perform gamma-ray spectroscopy suitable for extreme pileup situations, wherein traditional pulse-height spectroscopy is infeasible or impractical. One example of such application is spectral characterization of intense laser-based radiation sources that employ laser wakefield acceleration, in which a large number of photons can be produced in a well-collimated beam on a picosecond or shorter timescale. The method relies on the angularly-resolved calorimetric measurement of Compton scattering. The probability for a photon to undergo Compton scattering into a given solid angle is a function of its energy and is described by the Klein–Nishina formula. By first Compton scattering the incident beam and then measuring the total energies deposited in multiple detectors placed at various scattering angles, the incident beam energy spectrum can be reconstructed without resolving the individual events in detectors. Here, we compare the performance of an maximum likelihood expectation maximization algorithm with that of an artificial neural network to measure the energy spectrum of a beam of monoenergetic gamma rays from 137Cs decay. We demonstrate that the method can be used to reconstruct the characteristic inverse Compton scattering spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High precision real-time insertion device and monochromator synchronization at NSLS-II

We report that insertion devices have become the dominant photon source at synchrotron and free electron laser light source facilities the world over. Undulators, characterized by their small deflection parameter, exhibit a high degree of constructive interference in photon production from high energy charged particle beams leading to very high photon rates at specific harmonics of the fundamental frequency with relatively narrow spectral widths. Spectroscopic measurements of interest typically span several of these harmonic widths, which requires precision adjustment of an undulator’s magnetic gap to maintain peak flux within the much narrower bandwidth of a beamline monochromator at the desired energy. High precision insertion device controls are developed at NSLS-II including real-time linked control of monochromator hardware allowing for fast, high precision, hardware triggered, spectroscopic measurements. Furthermore, this fast fly scan method is described, compared statistically for self consistency, and shown to be far superior in both efficiency and accuracy as compared to standard step scan measurements.

36 MATERIALS SCIENCE↗

Shock compression experiments using the DiPOLE 100-X laser on the high energy density instrument at the European x-ray free electron laser: Quantitative structural analysis of liquid Sn

X-ray free electron laser (XFEL) sources coupled to high-power laser systems offer an avenue to study the structural dynamics of materials at extreme pressures and temperatures. The recent commissioning of the DiPOLE 100-X laser on the high energy density (HED) instrument at the European XFEL represents the state-of-the-art in combining x-ray diffraction with laser compression, allowing for compressed materials to be probed in unprecedented detail. Here, we report quantitative structural measurements of molten Sn compressed to 85(5) GPa and ~3500 K. The capabilities of the HED instrument enable liquid density measurements with an uncertainty of ~1% at conditions which are extremely challenging to reach via static compression methods. We discuss best practices for conducting liquid diffraction dynamic compression experiments and the necessary intensity corrections which allow for accurate quantitative analysis. We also provide a polyimide ablation pressure vs input laser energy for the DiPOLE 100-X drive laser which will serve future users of the HED instrument.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study on ion current density of different species in laser produced plasma in a solenoid magnet

A solenoid magnetic field along the expanding laser-produced plasma is an essential technique of the laser ion source. The solenoid field can increase ion beam current at beam extraction point by a factor of 2 to over 100 by confining moving laser produced plasma in transverse direction. This technique is used everywhere from development lab to operational machine for user operation. However, the motion of ions in laser produced plasma is not fully understood. In this study, we experimentally investigated the motion of ions in a solenoid magnet (inner diameter 102 mm, coil length 1980 mm) for Al, Fe, and Ta targets. Using the following three conditions: full solenoid bore, a φ51 mm collimator on the solenoid axis, and a thin-wall φ51 mm tube at the bottom of the solenoid, we found that extracting ions at off-axis position (20~30 mm from the solenoid axis in this study) can enhance ion intensity by a factor of three or more. We continue to investigate ion motion in a solenoid field to develop better laser ion source design.

43 PARTICLE ACCELERATORS↗

Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter

Measurements are presented of the reduction of signal output due to radiation damage for two types of plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb−1. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: a laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using 60Co sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved electro-optical tracking system

Electro-optical tracking system employs a laser beam illuminating source, an electronic laser beam deflector, and an image dissector photomultiplier. An electronic scanning transmitter and receiver follows rapid movements or accelerations of the target.

Johnson, R. E.↗

CO2 laser annealing of 50-microns-thick silicon solar cells

A test program is conducted to determine thin solar cell annealing effects using a laser energy source. A CO2 continuous-wave laser was used in annealing experiments on 50 micrometers-thick silicon solar cells after proton irradiation. Test cells were irradiated to a fluence of 1.0 x 10 to the 12th power protons/sq cm with 1.9 MeV protons. After irradiation, those cells receiving full proton dosage were degraded by an average of 30% in output power. In annealing tests laser beam exposure times on the solar cell varied from 2 seconds to 16 seconds reaching cell temperatures of from 400 C to 500 C. Under those conditions annealing test results showed recovery in cell output power of from 33% to 90%.

Walker, F. E.↗

First Results from Laser-Based Spectral Characterization of Landsat 9 Operational Land Imager-2

Landsat 9 will continue the Landsat data record into its fifth decade with launch scheduled for December 2020. The two instruments on Landsat 9 are Thermal Infrared Sensor-2 (TIRS-2) and Operational Land Imager-2 (OLI-2). OLI-2 is a nine-channel pushbroom imager with a 15-degree field of view that will have a 16-day measurement cadence from its nominal 705-km orbit altitude. A key aspect of the data that will be produced by OLI-2 is its spectral fidelity which enables countless science applications. The prelaunch test campaign for spectral characterization of OLI-2 was substantially improved relative to the methodology used for OLI: the full spectral response of every detector was characterized with greater accuracy, sampling, and precision. This paper will describe how this was accomplished with a tunable laser-based light source called Goddard Laser for Absolute Measurement of Radiance (GLAMR).

tunable laser↗

A Bezier Curve Informed Melt Pool Geometry to Model Additive Manufacturing Microstructures Using SPPARKS

Additive manufacturing is a transformative technology with the potential to manufacture designs which traditional subtractive machining methods cannot. Additive manufacturing offers fast builds at near final desired geometry; however, material properties and variability from part to part remain a challenge for certification and qualification of metallic components. AM induced metallic microstructures are spatially heterogeneous and highly process dependent. Engineering properties such as strength and toughness are significantly affected by microstructure morphologies resulting from the manufacturing process Linking process parameters to microstructures and ultimately to the dynamic response of AM materials is critical to certifying and qualifying AM built parts and components and improving the performance of AM materials. The AM fabrication process is characterized by building parts layer by layer using a selective laser melt process guided by a computer. A laser selectively scans and melts metal according to a designated geometry. As the laser scans, metal melts, fuses, and solidifies forming the final geometry in a layerwise fashion. As the laser heat source moves away, the metal cools and solidifies forming metallic microstructures. This work describes a microstructure modeling application implemented in the SPPARKS kinetic Monte Carlo computational framework for simulating the resulting microstructures. The application uses Bzier curves and surfaces to model the melt pool surface and spatial temperature profile induced by moving the laser heat source; it simulates the melting and fusing of metal at the laser hot spot and microstructure formation and evolution when the laser moves away. The geometry of the melt pool is quite flexible and we explore effects of variances in model parameters on simulated microstructures.

36 MATERIALS SCIENCE↗

Referenceless, grating-based, single shot X-ray phase contrast imaging with optimized laser-driven K-α sources

With its ability to efficiently probe low-Z materials, X-ray phase imaging methods have recently raised high interest in multiple fields from biology and medical applications to high energy density (HED) physics. Initially developed with synchrotron light and X-ray tubes, we present a novel grating based Talbot X-ray deflectometer (TXD) diagnostic that was coupled with laser-generated K-α X-ray sources. The multi-terawatt laser (I > 1 × 10 14 W cm -2 ) was used as a testbed for diagnostic development. It was found that X-ray source chromaticity plays an important role in TXD. Indeed, the broadband spectrum of laser-generated X-ray sources may strongly impact image quality and thus diagnostic performance. We qualified X-ray emission from different laser-produced sources and determined laser, target, and deflectometer parameters that optimize TXD performance. We present the first results of referenceless grating-based X-ray imaging at high-power laser facilities and discuss the implications of this new development in HED research.

47 OTHER INSTRUMENTATION↗

457-nm radiation source based on a diode laser for precision spectroscopy of magnesium atoms

We report on the development of a highly stable source of 457-nm radiation based on a diode laser and a tapered amplifier operating in a double-pass scheme. The diode laser frequency was stabilised by a high-Q reference Fabry – Perot interferometer and doubled in a PPSLT nonlinear crystal placed in an enhancement cavity. At a maximum output power of 200 mW at a wavelength of 457 nm, the laser linewidth was less than 5 kHz. The radiation source operation was demonstrated in experiments on precision spectroscopy of cold magnesium atoms in a magneto-optical trap. (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of 369.4 nm Radiation by Efficient Doubling of a Diode Laser

A resonant cavity second harmonic generation system has been developed to produce 369.4 nm radiation from a 738.8 nm diode laser with 10 mW nominal output power. This system utilizes a polarization technique to lock the cavity to the laser frequency. In this paper we report on an evaluation of the system using a Titanium:Sapphire laser as the input source, and preliminary results with a diode laser source. To our knowledge, this is the deepest uv light ever produced by frequency-doubling a diode laser.

Williams, A.↗