Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

A method to determine the electric field of liquid argon time projection chambers using a UV laser system and its application in MicroBooNE

Liquid argon time projection chambers (LArTPCs) are now a standard detector technology for making accelerator neutrino measurements, due to their high material density, precise tracking, and calorimetric capabilities. An electric field (E-field) is required in such detectors to 2020 JINST 15 P07010 drift ionization electrons to the anode where they are collected. The E-field of a TPC is often approximated to be uniform between the anode and the cathode planes. However, significant distortions can appear from effects such as mechanical deformations, electrode failures, or the accumulation of space charge generated by cosmic rays. The latter effect is particularly relevant for detectors placed near the Earth’s surface and with large drift distances and long drift time. To determine the E-field in situ, an ultraviolet (UV) laser system is installed in the MicroBooNE experiment at Fermi National Accelerator Laboratory. The purpose of this system is to provide precise measurements of the E-field, and to make it possible to correct for 3D spatial distortions due to E-field non-uniformities. Here we describe the methodology developed for deriving spatial distortions, the drift velocity and the E-field from UV-laser measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatiotemporal control of laser intensity through cross-phase modulation

Spatiotemporal pulse shaping provides control over the trajectory and range of an intensity peak. While this control can enhance laser-based applications, the optical configurations required for shaping the pulse can constrain the transverse or temporal profile, duration, or orbital angular momentum (OAM). Here we present a novel technique for spatiotemporal control that mitigates these constraints by using a "stencil" pulse to spatiotemporally structure a second, primary pulse through cross-phase modulation (XPM) in a Kerr lens. The temporally shaped stencil pulse induces a time-dependent focusing phase within the primary pulse. This technique, the "flying focus X," allows the primary pulse to have any profile or OAM, expanding the flexibility of spatiotemporal pulse shaping for laser-based applications. As an example, simulations show that the flying focus X can deliver an arbitrary-velocity, variable-duration intensity peak with OAM over distances much longer than a Rayleigh range.

47 OTHER INSTRUMENTATION↗

"Application of Tunable Diode Laser Spectrometry to Isotopic Studies for Exobiology"

Computer-controlled electrically-activated valves for rapid gas-handling have been incorporated into the Stable Isotope Laser Spectrometer (SILS) which now permits rapid filling and evacuating of the sample and reference gas cells, Experimental protocols have been developed to take advantage of the fast gas handling capabilities of the instrument and to achieve increased accuracy which results from reduced instrumental drift during rapid isotopic ratio measurements. Using these protocols' accuracies of 0.5 del (0.05%) have been achieved in measurements of 13C/12C in carbon dioxide. Using the small stable isotope laser spectrometer developed in a related PIDDP project of the Co-I, protocols for acquisition of rapid sequential calibration spectra were developed which resulted in 0.5 del accuracy also being achieved in this less complex instrument. An initial version of software for automatic characterization of tunable diode lasers has been developed and diodes have been characterized in order to establish their spectral output properties. A new state-of-the-art high operating temperature (200 K) mid infrared diode laser was purchased (through NASA procurement) and characterized. A thermo-electrically cooled mid infrared tunable diode laser system for use with high temperature operation lasers was developed. In addition to isotopic ratio measurements of carbon and oxygen, measurements of a third biologically important element (15N/14N in N2O gas) have been achieved to a preliminary accuracy of about 0.2%. Transfer of the basic SILS technology to the commercial sector is proceeding under an unfunded Space Act Agreement between NASA and SpiraMed, a medical diagnostic instrument company. Two patents have been issued. Foreign patents based on these two US patents have been applied for and are expected to be issued. A preliminary design was developed for a thermo-electrically cooled SILS instruments for application to planetary space flight exploration missions.

Sauke, Todd B.↗

Demonstration of full-scale spatiotemporal diagnostics of solid-density plasmas driven by an ultra-short relativistic laser pulse using an X-ray free-electron laser

Understanding the complex plasma dynamics in ultra-intense relativistic laser–solid interactions is of fundamental importance for applications of laser–plasma-based particle accelerators, the creation of high-energy-density matter, understanding planetary science, and laser-driven fusion energy. However, experimental efforts in this regime have been limited by the lack of accessibility of over-critical densities and the poor spatiotemporal resolution of conventional diagnostics. Over the last decade, the advent of femtosecond brilliant hard X-ray free-electron lasers (XFELs) has opened new horizons to overcome these limitations. Here, for the first time, we present full-scale spatiotemporal measurements of solid-density plasma dynamics, including preplasma generation with tens of nanometer scale length driven by the leading edge of a relativistic laser pulse, ultrafast heating and ionization at the main pulse arrival, the laser-driven blast wave, and transient surface return current-induced compression dynamics up to hundreds of picoseconds after interaction. These observations are enabled by utilizing a novel combination of advanced X-ray diagnostics including small-angle X-ray scattering, resonant X-ray emission spectroscopy, and propagation-based X-ray phase-contrast imaging simultaneously at the European XFEL-HED beamline station.

Huang, Lingen [Helmholtz-Zentrum Dresden-Rossendor↗

Controllable X-ray Pulse Trains from Enhanced Self-Amplified Spontaneous Emission

We report the demonstration of optical compression of an electron beam and the production of controllable trains of femtosecond, soft x-ray pulses with the Linac Coherent Light Source (LCLS) freeelectron laser (FEL). This is achieved by enhanced self-amplified spontaneous emission with a 2 μm laser and a dechirper device. Optical compression was achieved by modulating the energy of an electron beam with the laser and then compressing with a chicane, resulting in high current spikes on the beam which we observe to lase. A dechirper was then used to selectively control the lasing region of the electron beam. Field autocorrelation measurements indicate a train of pulses, and we find that the number of pulses within the train can be controlled (from 1 to 5 pulses) by varying the dechirper position and undulator taper. These results are a step toward attosecond spectroscopy with x-ray FELs as well as future FEL schemes relying on optical compression of an electron beam.

Duris, Joseph P↗

Physics and applications of quantum dot lasers for silicon photonics

Abstract Photonic integrated circuits (PICs) have enabled numerous high performance, energy efficient, and compact technologies for optical communications, sensing, and metrology. One of the biggest challenges in scaling PICs comes from the parasitic reflections that feed light back into the laser source. These reflections increase noise and may cause laser destabilization. To avoid parasitic reflections, expensive and bulky optical isolators have been placed between the laser and the rest of the PIC leading to large increases in device footprint for on-chip integration schemes and significant increases in packaging complexity and cost for lasers co-packaged with passive PICs. This review article reports new findings on epitaxial quantum dot lasers on silicon and studies both theoretically and experimentally the connection between the material properties and the ultra-low reflection sensitivity that is achieved. Our results show that such quantum dot lasers on silicon exhibit much lower linewidth enhancement factors than any quantum well lasers. Together with the large damping factor, we show that the quantum dot gain medium is fundamentally dependent on dot uniformity, but through careful optimization, even epitaxial lasers on silicon can operate without an optical isolator, which is of paramount importance for the future high-speed silicon photonic systems.

36 MATERIALS SCIENCE↗

The application of far IR lasers to the investigation of the optical properties of materials

The effect of diffusion on the saturation and absorption properties of molecular gases is considered. The analysis starts with a simple derivation of the multi-level rate equations. Incorporating the diffusion term, calculations are carried out both for the homogeneous and inhomogeneous broadening cases. Both graphical and analytical solutions are obtained for the absorption coefficient and the saturation intensity. It is shown that the effect of diffusion is characterized by a diffusion function, which varies inversely with the radius of the beam at low pressures and small beam sizes. The analysis is done in terms of two parameters k1a and k2a, which are simple functions of the intensity of the beam I, the effective relaxation rate w, and the effective diffusion constant D the a is designated as the radius of the beam.

Stafsudd, O. M.↗

Application of a pulsed laser for measurements of bathymetry and algal fluorescence.

The technique of measuring water depths with an airborne pulsed dye laser is studied, with emphasis on the degrading effect of some environmental and operational parameters on the transmitted and reflected laser signals. Extrapolation of measurements of laser stimulated fluorescence, performed as a function of both the algal cell concentration and the distance between the algae and the laser/receiver, indicate that a laser system operating from a height of 500 m should be capable of detecting chlorophyll concentrations as low as 1.0 mg/cu m.-

Hickman, G. D.↗

Application of a single laser Doppler system to the measurement of atmospheric winds

The feasibility of employing a single laser Doppler velocimeter (LDV) system to remotely measure one-, two-, and three-dimensional velocity components in atmospheric flow fields is presented. A focused continuous wave CO2 laser emitting at the 10.6 mu wavelength is used as the laser source. Scan configurations employed by the LDV system were single-point, two-point, conical, and spiral conical. Test results are presented, which include favorable comparisons of velocity components measured by conventional anemometry and the LDV system. The feasibility using a single-beam LDV employing a conical scan technique for measuring two- and three-dimensional mean winds. Measurements to 300 m in dense fogs showed the ability of the LDV system to operate in dense fogs.

Cliff, W. C.↗

A microprocessor application to a strapdown laser gyro navigator

The replacement of analog circuit control loops for laser gyros (path length control, cross axis temperature compensation loops, dither servo and current regulators) with digital filters residing in microcomputers is addressed. In addition to the control loops, a discussion is given on applying the microprocessor hardware to compensation for coning and skulling motion where simple algorithms are processed at high speeds to compensate component output data (digital pulses) for linear and angular vibration motions. Highlights are given on the methodology and system approaches used in replacing differential equations describing the analog system in terms of the mechanized difference equations of the microprocessor. Standard one for one frequency domain techniques are employed in replacing analog transfer functions by their transform counterparts. Direct digital design techniques are also discussed along with their associated benefits. Time and memory loading analyses are also summarized, as well as signal and microprocessor architecture. Trade offs in algorithm, mechanization, time/memory loading, accuracy, and microprocessor architecture are also given.

Giardina, C.↗

GaInAsSb/AlGaAsSb injection lasers for remote sensing applications

Double heterostructures of InGaAsSb/AlGaAsSb quaternary alloys on (100) GaSb substrates were grown by the liquid phase epitaxy (LPE) technique. Room temperature operation near 2.1 micron wavelength has been achieved under pulsed conditions with pulsed threshold current density of 7kA/sq cm.

Forouhar, Siamak↗