Solar Resource and Infrastructure Assessment for the Town of Westhampton

This report is a solar resource and infrastructure assessment for the town of Westhampton, Massachusetts. The assessment was funded through the National Renewable Energy Laboratory, Solar Energy Innovation Network (NREL SEIN) Solar in Rural Communities Program, as part of a project to develop a Community-Informed Proactive Solar Siting and Financing Model. As a first step, the project lead organization, UMass Clean Energy Extension prepared an assessment of existing infrastructure, resources, and potential solar development opportunities in participating municipalities, including Westhampton. This assessment was designed to describe relevant bylaws and infrastructure within the town, identify the types of solar facilities that could be developed, and quantify the total space available for each type of facility. In this report, we reviewed existing electricity grid infrastructure, and the potential to interconnect additional solar facilities. At the present time, both distribution lines providing electricity to Westhampton are oversaturated with authorized and proposed solar projects, and cannot accommodate additional solar projects to interconnect to the grid. Future upgrades could potentially free up additional capacity for new, large projects. Meanwhile, most three-phase lines could likely accommodate additional small-to-medium scale projects (under 200 kW), and most single-phase lines could likely accommodate additional projects under 50 kW in size. This description represents the local grid infrastructure as it is - planning for future scenarios of development could include recommendations for areas of grid infrastructure improvement to allow siting of distributed generation in locations preferred by the community. Future scenarios may also include the addition energy storage and other "non-wires alternatives."

14 SOLAR ENERGY↗

Caldera_Grid

Caldera Grid is part of Caldera software platform, a suite of collective, open-source tools that was developed to improve the state of the art in modeling the impacts of Electric Vehicle (EV) charging on the grid. Caldera Grid is a co-simulation framework implemented using Hierarchical Engine for Large scale Infrastructure Co-Simulation (HELICS). The framework facilitates the co-simulation of EV charging and Smart Charge Management (SCM) strategies in Caldera Infrastructure Charge Model (ICM) with distribution level grid models in OpenDSS. Vehicle energy needs and charge session requirements generated using Caldera Charge Decision Module (CDM) are fed in as input to Caldera Grid. The EV charging models in Caldera ICM simulates both the uncontrolled charging loads as well as loads modified by the SCM strategies to develop distributed load profiles for each grid node hosting an Electric Vehicle Supply Equipment (EVSE) – also known as chargers. These loads were simulated in OpenDSS alongside existing distribution feeder loads. Each of these models are co-simulated in a HELICS federate. The HELICS co-simulation framework facilitates communication and synchronization between the federates. By co-simulating EV loads and distribution feeder loads, Caldera Grid can assess the potential grid impacts of EV charging on distribution feeders under various grid conditions. A control strategy federate is implemented with an interface where control strategies based on feedback from EV charging status and grid conditions can be developed and implemented. The platform can also support multiple control strategies in a single co-simulation.

Sundarrajan, ManojKumar Cebol↗

Efficiency and Demand Flexibility in Large Office Buildings: The Potential for Cost Savings and CO 2 Reductions from Lighting and Cooling Measures

This report presents the estimated impact of lighting and cooling efficiency and demand flexibility measures in large office buildings in each state in the contiguous United States. It provides modeled results for three different metrics: bill savings, regional grid operational costs savings, and carbon dioxide (CO 2 ) emissions reductions. Lighting efficiency and demand flexibility are estimated to reduce load by up to 80 MWh/yr in a single large office building. These load reductions result in customer bill savings of up to $8,800/yr per building, with the highest savings in southern and midwestern states. Grid operating cost savings are estimated at up to $3,240/yr/building, with greatest benefit in southern and northeastern states. CO 2 emissions reduction potential is highest in the Dakotas, Nebraska, across the Midwest, in West Virginia, and in Mississippi (<48,200 kg/yr/building). Comparatively, cooling measures are found to have less load reduction potential (<28.5 MWh/yr/building), with the greatest potential in southern states including Texas, which ranks top of the list across several of the metrics studied. In numerous states, shifting cooling load to off-peak hours is found to increase costs and CO 2 emissions because precooling results in increased load during high-cost or high-CO 2 emissions periods. In general, focusing on cooling efficiency and load shedding has the potential for more savings. In all cases, the specific rate structure is a significant determinant in actual bill savings, which are up to $4,000/yr/building. To realize the full potential for bill savings through an energy measure, building operators must identify how the measure will change the building load pattern and the interaction of this load change with the applicable rate tariff. To realize CO 2 emissions reductions, industry and state coordination is needed to verify which fuel source is on the margin and then to create incentives for end users to reduce load during high-CO 2 emissions hours. Regular updates to data sets and analyses are critical. Regulators and policymakers are well positioned to facilitate the necessary coordination between the electric industry and building energy managers to develop appropriate price signals and incentives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Subsetted model output for meteorology-related variables on staggered grids from a LASSO-CACTI WRF simulation

Meteorology-related model output for variables on staggered grids from a Weather Research and Forecasting (WRF) simulation from the Large-Eddy Simulation (LES) Atmospheric Radiation Measurement (ARM) Symbiotic Simulation and Observation (LASSO) deep-convection scenario for the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign. The LASSO-CACTI simulations span grid spacings from 7.5 km to 100 m through the use of four nested domains, labeled d1 through d4. The simulations are of convection near the Sierras de Córdoba mountain range, roughly centered on the ARM Mobile Facility. More information can be found at https://www.arm.gov/capabilities/modeling/lasso. This version of the output is a collection of variables subsetted from the raw WRF output to reduce the file overhead for users not needing the full raw dataset. The subset files are in netCDF format with the height-based variables on the raw, model eta levels.

54 ENVIRONMENTAL SCIENCES↗

A Fast‐Charging and High‐Temperature All‐Organic Rechargeable Potassium Battery

Abstract Developing fast‐charging, high‐temperature, and sustainable batteries is critical for the large‐scale deployment of energy storage devices in electric vehicles, grid‐scale electrical energy storage, and high temperature regions. Here, a transition metal‐free all‐organic rechargeable potassium battery (RPB) based on abundant and sustainable organic electrode materials (OEMs) and potassium resources for fast‐charging and high‐temperature applications is demonstrated. N‐doped graphene and a 2.8 m potassium hexafluorophosphate (KPF 6 ) in diethylene glycol dimethyl ether (DEGDME) electrolyte are employed to mitigate the dissolution of OEMs, enhance the electrode conductivity, accommodate large volume change, and form stable solid electrolyte interphase in the all‐organic RPB. At room temperature, the RPB delivers a high specific capacity of 188.1 mAh g −1 at 50 mA g −1 and superior cycle life of 6000 and 50000 cycles at 1 and 5 A g −1 , respectively, demonstrating an ultra‐stable and fast‐charging all‐organic battery. The impressive performance at room temperature is extended to high temperatures, where the high‐mass‐loading (6.5 mg cm −2 ) all‐organic RPB exhibits high‐rate capability up to 2 A g −1 and a long lifetime of 500 cycles at 70–100 °C, demonstrating a superb fast‐charging and high‐temperature battery. The cell configuration demonstrated in this work shows great promise for practical applications of sustainable batteries at extreme conditions.

25 ENERGY STORAGE↗

Inrush Current Mitigation for Grid-Forming Inverters in Islanded Microgrids

Virtual-inertia and droop control methods are commonly used for grid-forming inverters. While the virtual inertia is used to emulate the equation of motion/frequency, if the inverter output voltage is emulated as in synchronous generators, then the method is known as the virtual synchronous generator. An inductive pulse-load, e.g., a relatively large induction motor, connection to a microgrid fed only by grid-forming inverters may lead to blackout due to high inrush currents. This article presents virtual reactance techniques to mitigate the inrush current effects and enhance the inverter’s robustness for the safe connection of inductive and dynamic loads. This article also compares the virtual inertia and droop control methods under switching inductive-dynamic loads while the proposed techniques are implemented. Experimental tests are performed considering the linear and nonlinear virtual reactance techniques, and the findings are discussed. The mitigation significantly suppresses the inrush currents while the inverters can perform a normal operation. Furthermore, the frequency and power response of the virtual inertia control with different inertia settings to a sudden change in the load is analyzed. The virtual reactance technique is tested in a laboratory-scale hardware setup of a 208V microgrid fed by 5kVA and 10kVA inverters, and the results are presented in this article.

Gursoy, Mehmetcan↗

Evaluating performance of different generative adversarial networks for large-scale building power demand prediction

We report as an unsupervised-learning data-driven model, Generative Adversarial Networks (GANs) have recently attracted a lot of attention for various applications. There is potential to apply GANs for large-scale building power demand prediction, which is needed for power grid operation. However, there are many GAN variations and it is unclear which GAN is suitable for this application. To answer this question, this paper identifies five promising GANs (Original GAN, cGAN, SGAN, InfoGAN, and ACGAN) and evaluates their performance for predicting building power demand at a large scale. Physics-based building energy models are developed to generate training and reference data. A new evaluation indicator that combines accuracy and reproducibility is proposed to evaluate the performance of different GANs in predicting building power demand. The results show that SGAN and InfoGAN are not suitable because they cannot control the number of generated building samples for different building types. The prediction performance among the Original GAN, cGAN, and ACGAN can vary depending on training sample sizes and number of building types. If the training sample size is sufficiently large, Original GAN and cGAN can predict building power demand more accurately than ACGAN with the same number of samples. If training samples are limited, Original GAN provides better accuracy than cGAN and ACGAN. When the number of building types increase, the prediction accuracy increases for cGAN, decreases for ACGAN, and remains the same for Original GAN. As a result, cGAN and Original GAN are recommended for large-scale building power demand prediction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Economics-by-Design Approach Applied to a Heat Pipe Microreactor Concept

Microreactors present a potential paradigm shift in the nuclear industry. Emphasis thus far has been on large-scale multi-billion-dollar projects that cater solely to grid electricity market. These projects can be challenging to finance and execute. On the other hand, microreactors are intended to target a wide variety of smaller niche markets and are expected to be factory-fabricated and more readily deployable. While diseconomies of scale for microreactors may tend to raise their costs per energy output (MWh) relative to large nuclear plants, offsetting gains can be expected from standardization, simplification, passive safety, lower radionuclide inventories, factory fabrication, fast installation, and low financing costs. To adequately assess these contributions, designers should have a different perspective on cost drivers than for large nuclear plants and can utilize novel approaches for systematic cost reduction. To account for these important aspects of microreactors, this report proposes an economics-by-design approach that places economic considerations at the center of the design process. The methodology builds on existing frameworks such as design-to-cost and value engineering, expanding them to new markets (beyond the grid), new attributes (beyond costs alone), and introducing the approach at earlier points in the design cycle. Design parameters and technical specifications are systematically evaluated until costs meet market entry points, while also providing the high-priority performance attributes of the particular use case. Determining first-order estimates for different components early in the process enables designers to focus R&D efforts on the biggest overall cost contributors and components with the most cost uncertainty. The analysis is always guided by market needs and threshold prices. In addition to microreactors, the approach is expected to be useful for other classes of nuclear reactors as well. The analysis was applied to a concept found in the open literature (the Design A heat-pipe reactor). A comprehensive bottom-up estimate was generated by leveraging a new microreactor-specific code of accounts and a range of cost equations. The initial estimate for levelized cost of electricity (LCOE) unsurprisingly exceeded market ranges since the use case had prioritized technological readiness over economic considerations in design choices. An alternate concept was then proposed, with various assumptions/targets made to reduce the largest cost contributors. Changes in the neutron spectrum, the power output, and building structures were found to make even the first-of-a-kind of this modified concept competitive with diesel generation in some remote communities. Learning rate (LR) assumptions indicated cost reductions achieved from sequential unit deployments could expand the range of competitiveness to include additional markets as deployments proceed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A review of machine learning in building load prediction

The surge of machine learning in recent years has been empowering engineer modeling in various fields. The decreasing hardware cost, increasing data accessibility, and advances of building automation system (BAS) allow the collection and storage of a significant amount of building operation data. The two facts provide great opportunities of applying machine learning to building energy systems modeling and analysis. There are a great number of research papers on this topic but there lacks a comprehensive and general review to summarize the current development, limitations, gaps and future trend. In this review paper series, machine learning techniques in building energy system modeling and analysis are reviewed under the organization and logic of the machine learning definition by Tom M. Mitchell: a computer program is said to learn from experience E with respect to some class of tasks T and performance measure P if its performance at tasks in T, as measured by P, improves with experience E. This paper is the first part of the review paper series, which focuses on building load prediction. First, the applications of building load prediction model (task T) are reviewed. Then, the modeling algorithms improving machine learning performance and accuracy (performance P) are reviewed. At the same time, the literature on the data perspective for modeling (experience E), including data engineering from sensors level to data level, pre-processing, feature extraction and selection, is reviewed. Finally, what is well-studied and what is lacking but with great potential are concluded; the gaps between present and future utilization of machine learning techniques are identified; the future trend and development are also predicted. The target readers of this paper are not only researchers from the building side who can get exposed to cutting edge machine learning tools, but also those from machine learning side who can understand the potential and challenge to apply machine learning in buildings.

Liang, Zhang↗

FlowPM: Distributed TensorFlow implementation of the FastPM cosmological N-body solver

Here, we present FlowPM, a Particle-Mesh (PM) cosmological N-body code implemented in Mesh-TensorFlow for GPU-accelerated, distributed, and differentiable simulations. We implement and validate the accuracy of a novel multi-grid scheme based on multiresolution pyramids to compute large-scale forces efficiently on distributed platforms. We explore the scaling of the simulation on large-scale supercomputers and compare it with corresponding Python based PM code, finding on an average 10x speed-up in terms of wallclock time. We also demonstrate how this novel tool can be used for efficiently solving large scale cosmological inference problems, in particular reconstruction of cosmological fields in a forward model Bayesian framework with hybrid PM and neural network forward model. We provide skeleton code for these examples and the entire code is publicly available at https://github.com/modichirag/flowpm[Formula presented].

79 ASTRONOMY AND ASTROPHYSICS↗

A reduced order sulfuric acid decomposition model for a nuclear-powered hybrid sulfur cycle

A reduced order model of sulfuric acid decomposition within a bayonet chemical reactor was developed to support the U. S. Department of Energy Integrated Energy System program, and address the lack of knowledge in scaling and integration for joint chemical and nuclear processes. Sulfuric acid decomposition within a bayonet reactor was modeled to provide chemical and thermodynamic data relevant to advanced nuclear reactor-driven integrated energy systems based on desired operational scale and operational conditions. The temperature range required for high-temperature advanced nuclear reactor integrated energy systems, 750-850 °C, was shown to produce reasonable agreement (within a few percent relative error) with past models and experimental data, and yielded good efficiency results for bayonet reactor operations. The results of the reduced order model agreed with previous work from Savannah River National Labs within a maximum of 3.4% error on the decomposition of sulfur trioxide, and on previous Hybrid Sulfur flowsheets from Gorensek and Summers that showed operational temperature, pressure, and composition ranges for efficiency which made the Hybrid Sulfur cycle competitive with water electrolysis. Here, the agreement with previous high-fidelity models provided a framework for future Integrated Energy System grid evaluations with an advanced nuclear reactor and large-scale hydrogen production using a mathematical model to represent chemical operations.

08 HYDROGEN↗

Toward prediction of turbulent atmospheric flows over propagating oceanic waves via machine-learning augmented large-eddy simulation

Wind-wave interactions have important effects on the energy harvesting of offshore wind farms. High-fidelity large-eddy simulation (LES) is a powerful approach for investigating wind-wave interactions in turbulent oceanic environments. Due to the large scale of the flow domain and the high grid resolution required to resolve multi-scale flow motions, however, brute-force LES of wind-wave interactions is computationally very expensive. We propose augmenting brute-force LES via machine-learning data-driven modeling (ML-LES) to dramatically reduce the computational time required to obtain converged turbulence statistics when the brute-force approach is employed. Namely, we employ a convolutional neural network (CNN) autoencoder trained and validated with LES data sets to develop a highly efficient ML-LES approach for computing turbulence statistics from just a few snapshots of instantaneous LES flow fields. Further, our results demonstrate the accuracy and efficiency of ML-LES in predicting the mean velocity, velocity fluctuations, and turbulence kinetic energy in highly stretched computational grid systems required to carry out simulations in real-life oceanic environments.

42 ENGINEERING↗

Exploring the First High-Entropy Thin Film Libraries: Composition Spread-Controlled Crystalline Structure

Thin films of two types of high-entropy oxides (HEOs) have been deposited on 76.2 mm Si wafers using combinatorial sputter deposition. In one type of the oxides, (MgZnMnCoNi)O x , all the metals have a stable divalent oxidation state and similar cationic radii. In the second type of oxides, (CrFeMnCoNi)O x , the metals are more diverse in the atomic radius and valence state, and have good solubility in their sub-binary and ternary oxide systems. Therefore, the resulting HEO thin films were characterized using several high-throughput analytical techniques. The microstructure, composition, and electrical conductivity obtained on defined grid maps were obtained for the first time across large compositional ranges. The crystalline structure of the films was observed as a function of the metallic elements in the composition spreads, that is, the Mn and Zn in (MgZnMnCoNi)O x and Mn and Ni in (CrFeMnCoNi)O x . The (MgZnMnCoNi)O x sample was observed to form two-phase structures, except single spinel structure was found in (MgZnMnCoNi)O x over a range of Mn > 12 at. % and Zn < 44 at. %, while (CrFeMnCoNi)O x was always observed to form two-phase structures. Composition-controlled crystalline structure is not only experimentally demonstrated but also supported by density function theory calculation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-channel front-end ASIC for a 3D position-sensitive detector

Arrays of 3D position-sensitive detectors (3DPSD), operating at room temperature and using cadmium zinc telluride (CZT) and thallium bromide (TIBr) sensors, are suitable for gamma-ray spectrometry in many applications. One detector configuration, the 3D position-sensitive Virtual Frisch-Grid detector (VFG), is particularly advantageous for integrating into large area arrays. The signals generated inside each detector of the array are captured with the anode, cathode and four pads that enable the reconstruction of the position and energy of the ionizing interaction by measurements of amplitude and timing of the signals. For these applications, a low-noise front-end ASIC has been developed, capable of processing bipolar signals (needed because of AC-coupling of certain electrodes). The ASIC can be coupled to an ADC in order to form a compound “waveform digitizer” capable of post-processing the analog signals and determining amplitude and timing information. This paper describes a 32-channel front-end ASIC that is suitable for reading out a 3 × 3 or 4 × 4 element matrix in the VFG configuration. Each channel is composed of a low-noise charge amplifier with an adaptive continuous reset feedback circuit suitable for both positive and negative charge, a first order shaper and a single-to-differential converter output stage. Voltage and current references are all internally generated by 10-bit DACs and the chip is fully controllable with the I 2 C communication protocol. The readout channel response has been verified using the implemented injection circuit. Linear behavior up to ~75 ke ± with the gain of ~80 mV/fC, and up to ~200 ke ± with the gain of ~30 mV/fC was demonstrated. In conclusion, the first test result waveforms using a 137 Cs radioactive source on a 5 × 5 × 12 mm 3 TIBr crystal are reported.

47 OTHER INSTRUMENTATION↗

Development of an Encoding Method on an Co-simulation Platform for Mitigating the Impact of Unreliable Communication

This report presents a hardware-in-the-loop (HIL) based modeling approach for simulating impacts of unreliable communication on the performance of centralized volt-var control and for developing an encoding method to mitigate the impacts. First, an asynchronous real-time HIL simulation platform is introduced to enable multi-rate co-simulation of a distribution system with many inverter-based distributed energy resources (DERs). The distribution system is modeled by milliseconds phasor-based models and the DERs are modeled by micro-seconds power electronic models. Communication connections between a centralized volt-var controller (modeled externally to the HIL testbed) and smart inverters are built by implementing Modbus links and the Long Term Evolution network. On this co-simulation platform, an enhanced, augmented Lagrangian multiplier based encoded data recovery (EALM-EDR) algorithm for mitigating the impact of unreliable communication is developed and validated. Simulation results demonstrate the efficacy of using the HIL-based co-simulation platform as a power grid digital twin for developing algorithms that coordinate a large number of heterogeneous control systems through wired and wireless communication links.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrolyte Takeover Strategy for Performance Recovery in Polysulfide-Permanganate Flow Batteries

The abundance of active material precursors for a polysulfide-permanganate flow battery makes it a compelling chemistry for large-scale, and potentially long-duration (>10 h), grid electricity storage. Precipitation, arising from either reactant crossover or electrolyte side reactions, decrease cell efficiencies during charge/discharge cycling. Regardless of the abundance and low cost of active materials, a system without high cyclability cannot meet grid electricity storage economic targets for applications that cycle regularly. Precipitated species can be removed, and reactor efficiency performance restored, by using an electrolyte takeover process, or ETP. Two ETP methods are investigated. One ETP uses the negative electrolyte, an alkaline polysulfide (pS) solution, as takeover solution, and another uses dilute acidic peroxide (DAP) as the takeover solution. Both ETPs maintain functional cell operation within an acceptable performance range over >1000 h and >200 cycles, a duration over which cells that do not undergo ETPs clog and fail. The DAP ETP proves especially effective and limits irrecoverable voltage efficiency fade below 0.02%/cycle. These ETPs, either individually, or in combination, can enable the requisite cyclability for practical polysulfide-permanganate flow battery systems.

25 ENERGY STORAGE↗

On the Effectiveness of Neural Operators at Zero-Shot Weather Downscaling [SWR-25-20]

Code repository for the experiments performed in the paper: On the Effectiveness of Neural Operators at Zero-Shot Weather Downscaling (https://doi.org/10.1017/eds.2025.11) Overall, our work investigates the zero-shot downscaling potential of neural operators. To summarize, our contributions are: 1. We provide a comparative analysis based on two challenging weather downscaling problems, between various neural operator and non-neural-operator methods with large upsampling factors (e.g., 8x and 15x) and fine grid resolutions (e.g., 2 km × 2 km wind speed). 2. We examine whether neural operator layers provide unique advantages when testing downscaling models on upsampling factors higher than those seen during training, i.e., zero-shot downscaling. Our results instead show the surprising success of an approach that combines a powerful transformer-based model with a parameter-free interpolation step at zero-shot weather downscaling. 3. We find that this Swin-Transformer-based approach mostly outperforms all neural operator models in terms of average error metrics, whereas an enhanced super-resolution generative adversarial network (ESRGAN)-based approach is better than most models in capturing the physics of the system, and suggests their use in future work as strong baselines. However, these approaches still do not capture variations at smaller spatial scales well, including the physical characteristics of turbulence in the HR data. This suggests a potential for improvement in transformer or GAN-based methods and neural-operator-based methods for zero-shot weather downscaling.

Sinha, Saumya [National Renewable Energy Laborator↗

A Review of Sandia Energy Storage Research Capabilities and Opportunities (2020 to 2030)

Large-scale integration of energy storage on the electric grid will be essential to enabling greater penetration of intermittent renewable energy sources, modernizing the grid for increased flexibility security, reliability, and resilience, and enabling cleaner forms of transportation. The purpose of this report is to summarize Sandia's research and capabilities in energy storage and to provide a preliminary roadmap for future efforts in this area that can address the ongoing program needs of DOE and the nation. Mission and vision statements are first presented followed by an overview of the organizational structure at Sandia that provides support and activities in energy storage. Then, a summary of Sandia's energy storage capabilities is presented by technology, including battery storage and materials, power conversion and electronics, subsurface-based energy storage, thermal/thermochemical energy storage, hydrogen storage, data analytics/systems optimization/controls, safety of energy storage systems, and testing/demonstrations/model validation. A summary of identified gaps and needs is also presented for each technology and capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗