Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion beam analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Measurement of directed flow in Au + Au collisions at $\sqrt{s{NN}}$ = 19.6 and 27 GeV with the STAR event plane detector

In heavy-ion collision experiments, the global collectivity of final-state particles can be quantified by anisotropic flow coefficients (𝑣 𝑛 ) . The first-order flow coefficient, also referred to as the directed flow (𝑣 1 ), describes the collective sideward motion of produced particles and nuclear fragments in heavy-ion collisions. It carries information on the very early stage of the collision, especially at large pseudorapidity (𝜂), where it is believed to be generated during the nuclear passage time. Directed flow therefore probes the onset of bulk collective dynamics during thermalization, providing valuable experimental guidance to models of the pre-equilibrium stage. In 2018, the Event Plane Detector (EPD) was installed in STAR and used for the Beam Energy Scan phase-II (BES-II) data taking. The combination of EPD (2.1 < |𝜂| < 5.1) and high-statistics BES-II data enables us to extend the 𝑣 1 measurement to the forward and backward 𝜂 regions. In this paper, we present the measurement of 𝑣 1 over a wide 𝜂 range in Au + Au collisions at $\sqrt{s_{NN}}$ = 19.6 and 27 GeV using the STAR EPD. The results of the analysis at $\sqrt{s_{NN}}$ = 19.6 GeV exhibit excellent consistency with the previous PHOBOS measurement, while elevating the precision of the overall measurement. The increased precision of the measurement also revealed finer structures in heavy-ion collisions, including a potential observation of the first-order event-plane decorrelation. Multiple physics models were compared to the experimental results. Only a transport model and a three-fluid hybrid model can reproduce a sizable 𝑣 1 at large 𝜂 as was observed experimentally. The model comparison also indicates 𝑣 1 at large 𝜂 might be sensitive to the QGP phase transition.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fermilab Booster Beam Emittances from Quadrupole Modes Measured BPMs

The measurement of beam emittances by extracting the quadrupole mode signal from a 4 plate beam position monitor (BPM) was published at least 40 years ago. Unfortunately, in practice, this method suffers from poor signal to noise ratio and requires a lot of tuning to extract out the emittances. In this paper, an improved method where multiple BPMs are used together with better mathematical analysis is described. The BPM derived emittances are then compared with those measured by the Ion Profile Monitor (IPM). Surprisingly, the BPM measured emittances behave very well and are more realistic than those measured by the IPM.

43 PARTICLE ACCELERATORS↗

Fermilab Booster Beam Emittances from Quadrupole Modes Measured by BPMs

The measurement of beam emittances by extracting the quadrupole mode signal from a 4 plate beam position monitor (BPM) was published at least 40 years ago. Unfortunately, in practice, this method suffers from poor signal to noise ratio and requires a lot of tuning to extract out the emittances. In this paper, an improved method where multiple BPMs are used together with better mathematical analysis is described. The BPM derived emittances are then compared with those measured by the Ion Profile Monitor (IPM). Surprisingly, the BPM measured emittances behave very well and are more realistic than those measured by the IPM.

43 PARTICLE ACCELERATORS↗

Micrometer to Atomic Scale Characterisation of Primitive Astromaterials Using A Novel Method, Metis-Fa: A Coordinated Atom Probe Tomography, Transmission Electron Microscopy and NanoSIMS Approach

Introduction: Presolar grains preserve isotopic, chemical and microstructural records of physical and chemical processing, and formation mechanisms within a vast range of evolved stellar systems, the interstellar medium, solar nebula and their parent bodies. These evolutionary records are preserved at the micrometric to atomic scale, requiring coordinated studies to expand our understanding of evolutionary processes occurringthroughout ours and external stellar systems [1]. NanoSIMS enabled rapid in situ identification and isotopic characterisation of presolar grains and their stellar origins using 17O/16O and 18O/16O, and 13C/12C isotopic ratios [1]. Coordination with transmission electron microscopy (TEM) revealed crystallographic and localised contextual relationships and quantitively constrained their major and minor compositions [1]. However, trace elements cannot be quantified, the most sensitive geochemical tracers of environmental conditions, essential to unravelling the chemical record of their evolutionary pathway and parent stellar systems [2-3] . Furthermore, owing to the combination of technical limitations (only 5 – 7 isotopes can be measured per NanoSIMS run) and their small grain sizes of 100 nm < 3 μm (with rare exceptions in nanodiamonds (2 nm ≤) and SiC (< 40 μm)), the number of measurable isotopes per grain volume is limited [1,3] . Through more comprehensive isotopic studies of presolar grains, NanoSIMS studies have shown the importance of the latter, identifying Fe and Mg as important indicators of nuclear synthetic processing and their stellar origins, respectively [4- 5]. Coordination of NanoSIMS and Atom Probe Tomography (APT) revealed morphological signatures, and isotopic and chemical signatures at major to trace levels without requirements for preselection of elements [6]. However, crystallographic signatures in localized contextual relationships cannot be measured. Consequently, coordination of NanoSIMS, TEM and APT is essential to gain access to almost all contextual, structural and geochemical signatures within each presolar grain.Transmission electron microscopy requires a 100 nm thin lamella which is unstable in APT and would not produce any viable data. Atom probe tomography requires a needle-shaped specimen which when measured in TEM removes the local context, impacts the quality of the TEM diffraction images due to the shank angle of the needle, and can alter the chemistry of beam sensitive materials from the higher degree of surface exposure at the tip. To address these issues, we developed METIS-Fa (Multi-technical measurements of Electron Transparent materials using an Indium Sandwich - a FIB approach). A novel method which enables coordination of NanoSIMS, TEM and APT for generalized and targeted studies of individual grains, including beam sensitive materials, without compromising sample preparation requirements for TEM and APT. This method requires only indium and a Focus Ion Beam (FIB), minimizing the movement of fragile materials while still enabling preparation of TEM lamella into APT needles. Samples: Initial experimental development and testing of the method occurred at Astromaterials Research and Exploration Science (ARES), Johnson Space Centre (JSC), NASA and APT measurements and needle preparation occurred at JdLC, Curtin University. Synthetic silicate samples were used as analogs for presolar silicates when performing a trial run of the method. Samples were extracted from a polished thin section created at JSC, NASA, comprised of 38 wt.% Si, 17 wt.% FeO, 13 wt.% MgO, 12 wt.% Al, 11 wt.% Ca based on electron microprobe analysis (EMPA) [8] . Experimental details, pressure and temperature conditions were presented in [8] and references therein. Testing of the capability to target individual grains in mineral matrices using this method for acquisition in APT, measured matrix regions in meteoritic thin sections of primitive meteorites. These meteorites and their identified presolar grains for future targeted studies are detailed in [9]. Techniques: The TEM-FIB lamella were prepared using a FIB. An e-beam assisted pt deposition was used as a protective coating for the synthetic and meteoritic samples. When targeting individual grains, a secondary e-beam assisted pt deposition button is placed over the desired grain before the protective coating to denote its location. A JEOL 2500SE field-emission TEM was used for high-resolution imaging, energy-dispersive X-ray (EDX) and electron diffraction data.TheMETIS-Fa method was experimentally designed, tested and executed using a FIB at ARES, JSCNASA. Needles for APT were prepared using the Tescan Lyra3 GM Dual Beam Focus Ion Beam (FIB) Field Emission SEM (FE-SEM) at the JdLC, Curtin University. Atom probe tomography measurements were conducted using a CAMECA Local Electrode Atom Probe, LEAP 4000X HR. Two pure indium needles were analyzed initially to constraining acquisition parameters and stability under the beam. Manual acquisition was required to maintain evaporation of specimen’s at the apex and monitor interactions with measurement parameters. Experimental Design: Indium foil is pressed onto an Al stub with a pneumatic press and mounted into the FIB adjacent to the TEM-FIB lamella of interest. Using a FIB, two indium slices (5 μm x ~300 nm x 3 μm) are extracted from indium foil and aligned with the TEM-FIB lamella before touching the TEM-FIB lamella. Each slice is then attached through cold welding to the FIB-TEM lamella. This approach eliminates the need for chemical treatments and proved effective for aligning the Indium within the region of interest for APT, holding it in place for up to 4 days during testing.Once both indium slices are attached within their pre-determined region per grain targeting requirements, they are gradually melted onto the FIB-TEM lamella.When targeting a specific grain, measurements should be taken of the pt button and its distance from edge to edge of the lamella before and after sandwiching. A secondary button should be placed over the same region after the Indium slices have been attached to improve precision when preparing APT needles. Results: Figure 1 shows two indium slices melted onto a FIB-TEM lamella, adding additional bulk for preparation into APT needles as shown in Figure 2 [7] . The latter was essential so samples could be measured in TEM and APT without compromising sample preparation requirements and consequently data quality and acquisition stability. METIS-Fa proved effective forimproving geometry. Figure 3 shows a successful APTrun of the synthetic silicate. EMPA, TEM and APTshowed no chemical alterations. During targetingtesting, a solar silicate grain was successfully identifiedand measured in TEM, and prepared into an APTneedle. However, the indium was melted too long during sample preparation, causing expansion andformation of internal porosity leading to sample loss.Conclusion: METIS-Fa greatly expands the number of isotopic and chemical signatures measured per grain volume, and enables measurements of contextual, structural, crystallographic, isotopic and geochemical signatures within individual grains. Gaining access to such a vast range of evolutionary signatures required for expanding our understanding of external stellar and planetary systems and the evolution of our solar system. This method was designed for application to a vast range of phases including being sensitive materials and thus provides a way for coordination of NanoSIMS, TEM and APT not just for the study of presolar grains and by extension primitive astromaterials, but studies in a vast range of other fields including the geosciences and material sciences.Acknowledgments: Thankyou to ARES, JSC, NASA; JdLC Curtin University and Space Science Technology Centre for the use of laboratory facilities and funding [confirm].

Nicole D Nevill↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Structural and optical characterization of dilute Bi-doped GaN nanostructures grown by molecular beam epitaxy

We have carried out detailed studies on the epitaxy and characterization of dilute Bi-doped GaN nanostructures. A comprehensive investigation of Bi-doped GaN nanowires and quasi-film epitaxial growth conditions has been performed. Scanning electron microscopy studies show that lowering the GaBiN growth temperature causes gradual changes in top c-plane nanowire morphology due to the incremental incorporation of foreign Bi atoms. This trend is further substantiated by the secondary ion mass spectroscopy analysis of a multi-layer Bi-doped GaN quasi-film. However, it is also found that the amount of Bi incorporation into the GaN lattice is relatively independent of the N2 flow rate variation under the growth conditions investigated. Furthermore, room-temperature micro-Raman spectra show that there are additional peaks near 530, 650, and 729 cm−1 wave numbers in the Bi-doped GaN samples, which can primarily be attributed to Bi local vibrational modes, indicative of a small amount of Bi incorporation in the GaN lattice. Moreover, phonon calculations with density functional theory indicate that Bi replacing the N sites is the likely origin of the experimentally measured Raman modes. X-ray photoelectron spectroscopy measurements have also been obtained to deduce the electronic interaction between the Bi dopant atom and the GaN nanostructure. Such one-dimensional nanowires permit the synthesis of dislocation-free highly mismatched alloys due to strain relaxation, allowing efficient light absorption and charge carrier extraction that is relevant for solar energy harvesting and artificial photosynthesis.

Materials Science↗

Electrostatic propulsion beam divergence effects on spacecraft surfaces, volume 2

The third phase of a program to develop understanding of and tolerance-level criteria for the deleterious effects of electrostatic rocket exhaust (Cs, Cs(+), Hg, Hg(+)) and materials of rocket construction impinging on typical classes of spacecraft (S/C) surfaces was completed. Models of ion engine effluents and models describing the degradation of S/C surfaces by these effluents are presented. Experimental data from previous phases are summarized and Phase 2 data and analysis are presented in detail. The spacecraft design implications of ion engine contaminants are discussed.

Hall, D. F.↗

On Alfvénic turbulence of solar wind streams observed by Solar Orbiter during March 2022 perihelion and their source regions

It has been recently accepted that the standard classification of the solar wind solely according to flow speed is outdated, and particular interest has been devoted to the study of the origin and evolution of so-called Alfvénic slow solar wind streams and to what extent such streams resemble or differ from fast wind. In March 2022, Solar Orbiter completed its first nominal phase perihelion passage. During this interval, it observed several Alfvénic streams, allowing for characterization of fluctuations in three slow wind intervals (AS1-AS3) and comparison with a fast wind stream (F) at almost the same heliocentric distance. This work makes use of Solar Orbiter plasma parameters from the Solar Wind Analyzer (SWA) and magnetic field measurements from the magnetometer (MAG). The magnetic connectivity to the solar sources of selected solar wind intervals was reconstructed using a ballistic extrapolation based on measured solar wind speed down to the (spherical) source surface at 2.5 R s below which a potential field extrapolation was used to map back to the Sun. The source regions were identified using SDO/AIA observations. A spectral analysis of in situ measured magnetic field and velocity fluctuations was performed to characterize correlations, Alfvénicity, normalized cross-helicity, and residual energy in the frequency domain as well as intermittency of the fluctuations and spectral energy transfer rate estimated via mixed third-order moments. A machine learning technique was used to separate proton core, proton beam, and alpha particles and to study v − b correlations for the different ion populations in order to evaluate the role played by each population in determining the Alfvénic content of solar wind fluctuations. The comparison between fast wind and Alfvénic slow wind intervals highlights the differences between the two solar wind regimes: The fast wind is characterized by larger amplitude fluctuations, and magnetic and velocity fluctuations are closer to equipartition of energy. In fact the Alfvénic slow wind streams appear to be on a spectrum of wind types, with AS1, originating from open field lines neighboring active regions and displaying similarities with the fast wind in terms of fluctuation amplitude and turbulence characteristics, but not with respect to the alpha particles and proton beams. The other two slow streams differed both in their sources as well as plasma characteristics, with AS2 coming from the expansion of a narrow coronal hole corridor and AS3 from a region straddling a pseudostreamer. The latter displayed the coldest and highest density but the slowest stream with the smallest fluctuation amplitude and greatest magnetic energy excess. It also showed the largest scatter in proton beam speeds and the greatest difference in speed between proton beam and alpha particles. This study shows how the old fast–slow solar wind dichotomy, already called into question by the observations of slower Alfvénic solar wind streams, should further be refined, as the Alfvénic slow wind, originating in different solar wind regions, show significant differences in density, temperature, and proton and alpha-particle properties in the inner heliosphere. The observations presented here provide the starting point for a better understanding of the origin and evolution of different solar wind streams as well as the evolving turbulence contained within.

magnetohydrodynamics (MHD)↗

The bond energy of UN + : Guided ion beam studies of the reactions of U + with N 2 and NO

In this work, a guided ion beam tandem mass spectrometer was used to study the reactions of U + with N 2 and NO. Reaction cross sections were measured over a wide range of energy for both systems. In each reaction, UN + is formed by an endothermic process, thereby enabling the direct measurement of the threshold energy and determination of the UN + bond dissociation energy. For the reaction of U + + N 2 , a threshold energy (E 0 ) of 4.02 ± 0.11 eV was measured, leading to D 0 (UN + ) = 5.73 ± 0.11 eV. The reaction of U + + NO yields UO + through an exothermic, barrierless process that proceeds with 94 ± 23% efficiency at the lowest energy. Analysis of the endothermic UN + cross section in this reaction provides E 0 = 0.72 ± 0.11 eV and, therefore, D 0 (UN + ) = 5.78 ± 0.11 eV. Averaging the values obtained from both reactions, we report D 0 (UN + ) = 5.76 ± 0.13 eV as our best value (uncertainty of two standard deviations). Combined with precise literature values for the ionization energies of U and UN, we also derive D 0 (UN) = 5.86 ± 0.13 eV. Both bond dissociation energies agree well with high-level theoretical treatments in the literature. The formation of UN + in reaction of U + with NO also exhibits a considerable increase in reaction probability above ~3 eV. Theory suggests that this may be consistent with the formation of UN + in excited quintet spin states, which we hypothesize are dynamically favored because the number of 5f electrons in reactants and products is conserved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Charged particle track reconstruction with SπRIT Time Projection Chamber

In this work, we present a software framework, SπRITROOT, which is capable of track reconstruction and analysis of heavy-ion collision events recorded with the SRIT time projection chamber. The track-fitting toolkit GENFIT and the vertex reconstruction toolkit RAVE are applied to a box-type detector system. A pattern recognition algorithm which performs helix track finding and handles overlapping pulses is described. The performance of the software is investigated using experimental data obtained at the Radioactive Isotope Beam Facility (RIBF) at RIKEN. This work focuses on data from 132 Sn + 124 Sn collision events with beam energy of 270 AMeV. Particle identification is established using < dE/dx >and magnetic rigidity, with pions, hydrogen isotopes, and helium isotopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chromosome Aberrations in Human Epithelial Cells Exposed Los Alamos High-Energy Secondary Neutrons: M-BAND Analysis

High-energy secondary neutrons, produced by the interaction of galactic cosmic rays (GCR) with the atmosphere, spacecraft structure and planetary surfaces, contribute a significant fraction to the dose equivalent radiation measurement in crew members and passengers of commercial aviation travel as well as astronauts in space missions. The Los Alamos Nuclear Science Center (LANSCE) neutron facility's 30L beam line (4FP30L-A/ICE House) is known to generate neutrons that simulate the secondary neutron spectrum of the Earth's atmosphere at high altitude. The neutron spectrum is also similar to that measured onboard spacecrafts like the MIR and the International Space Station (ISS). To evaluate the biological damage, we exposed human epithelial cells in vitro to the LANSCE neutron beams with an entrance dose rate of 2.5 cGy/hr, and studied the induction of chromosome aberrations that were identified with multicolor-banding in situ hybridization (mBAND) technique. With this technique, individually painted chromosomal bands on one chromosome allowed the identification of inter-chromosomal aberrations (translocation to unpainted chromosomes) and intra-chromosomal aberrations (inversions and deletions within a single painted chromosome). Compared to our previous results with gamma-rays and 600 MeV/nucleon Fe ions of high dose rate at NSRL (NASA Space Radiation Laboratory at Brookhaven National Laboratory), the neutron data from the LANSCE experiments showed significantly higher frequency of chromosome aberrations. However, detailed analysis of the inversion type revealed that all of the three radiation types in the study induced a low incidence of simple inversions. Most of the inversions in gamma-ray irradiated samples were accompanied by other types of intrachromosomal aberrations but few inversions were accompanied by interchromosomal aberrations. In contrast, neutrons and Fe ions induced a significant fraction of inversions that involved complex rearrangements of both inter- and intrachromosome exchanges. The distribution of damage sites on chromosome 3 was also compared for different radiation types. The breakpoints were randomly localized on chromosome 3 with neutrons and Fe ions exposure, whereas non-random distribution with clustering breakpoints was observed with gamma-rays exposure. The specific fingerprint of neutron radiations on chromosomal aberrations will be discussed.

Hada, M.↗

Surface recombination velocity and diffusion length of minority carriers in heavily doped silicon layers

Quantitative analysis of the electron beam-induced current and the dependence of the effective diffusion length of the minority carriers on the penetration depth of the electron beam were employed for the analysis of the carrier recombination characteristics in heavily doped silicon layers. The analysis is based on the concept of the effective excitation strength of the carriers which takes into consideration all possible recombination sources. Two dimensional mapping of the surface recombination velocity of P-diffused Si layers will be presented together with a three dimensional mapping of minority carrier lifetime in ion implanted Si. Layers heavily doped with As exhibit improved recombination characteristics as compared to those of the layers doped with P.

Gatos, H. C.↗

Helium Ion Microscopy

Nanotechnology research led to the development of various instruments to be used for imaging or fabrication. The helium ion microscope (HIM) became available in 2006 but quickly gained popularity. Its unique gas field ion source enables high-resolution imaging, nanofabrication, direct write, and the recent combination with a secondary ion mass spectrometer offers chemical imaging with ~15 nm resolution. Particularly attractive are the small interaction volume of He and Ne (the two gases offered), small beam spot size, and a moderate sputtering rate. Additionally, the HIM is an excellent imaging tool for insulating samples in soft, polymeric, and biological materials. It can be expected that helium ion microscopy will continue to have a strong influence on broad range of scientific disciplines, including chemistry, materials science, and biology.This chapter aims at providing an overview of the current status of HIM for imaging, analysis, and nanofabrication. It introduces the reader to key components of the instrument, theoretical background, and latest results in the areas of imaging, material fabrication, and chemical analysis capabilities of helium ion microscopy.

Belianinov, Alex↗

Investigations of nonlinear polarization transfer between obliquely intersecting beams

Electromagnetic waves propagating through plasma can interact nonlinearly through a variety of different mechanisms. The excitation of a plasma beat wave (ions or electrons) can create a refractive index modulation that changes the dispersion of the interacting beams. Alternatively, high-intensity beams can enter the regime where relativistic nonlinearities influence the propagation dynamics. In recent studies [ Opt. Express 29 , 1162 ( 2021 ) OPEXFF 1094-4087 10.1364/OE.413064 ], it was proposed that two beams propagating along the same axis can exchange their polarization state due to nonlinear interaction. Here we present a numerical analysis of two laser beams intersecting in a nonlinear medium at varying angles. Polarization transfer is observed as predicted by analytical theory for a range of angles. For small angles, it is found that filamentation of the interacting beams becomes important. Analytical estimates of the filamentation threshold are presented, and good agreement is found with the simulation data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of plasma measurements for the Geotail mission

The first phase of the Geotail mission, an exploration of the distant magnetotail, was successfully concluded in October 1994. Geotail is currently engaged in a survey of plasmas at distances from Earth approximately 10 to 30 R(sub E). Throughout the mission the Comprehensive Plasma Instrumentation has functioned well with successful return of data. The analysis of the CPI measurements has resulted in a series of publications, and research efforts are ongoing. Research topics include interaction of the magnetotail with the fields and plasmas of the solar wind, steady-state magnetic reconnection in the distant magnetotail at a neutral line bounded by a pair of slow-mode magnetohydrodynamic shocks, development and evolution of plasmoids in magnetotail and magnetospheric substorms, and cold ion beams coexisting as distinct components in the presence of hot plasma-sheet plasmas.

Frank, Louis A.↗

Non-gyrotropic proton and alpha-particle velocity distributions in the solar wind: TAUS observations and stability analysis

Ion velocity distribution functions have been measured with high time resolution by the TAUS plasma instrument on the PHOBOS mission to Mars in 1989. The unambiguous separation of protons and alpha-particles by TAUS enabled us to study the nonthermal features of their distributions separately and to analyze the stability of the distributions against excitation of waves in the cyclotron-frequency domain. Typical nonthermal features include temperature anisotropies, with T(sub perpendicular) larger than T(sub parallel), and ion beam populations drifting along the local magnetic field direction. Also, distinctly non-gyrotropic alpha-particle velocity distributions were sometimes found. Non-gyrotropy strongly changes the wave dispersion and gives rise to new growing modes, related to the coupling of the standard wave modes existing in gyrotropic plasma. It is found that for the measured non-gyrotropic ion distributions the right-hand polarized wave can also be excited by a temperature anistropy instead of the usual beam drift.

Astudillo, H. F.↗

NASA Tech Briefs, May 2008

Topics covered inclde: Deployable Wireless Camera Penetrators; Hand-Held Units for Short-Range Wireless Biotelemetry; Wearable Wireless Telemetry System for Implantable BioMEMS Sensors; Electronic Escape Trails for Firefighters; Architecture for a High-to-Medium-Voltage Power Converter; 24-Way Radial Power Combiner/Divider for 31 to 36 GHz; Three-Stage InP Submillimeter-Wave MMIC Amplifier; Fast Electromechanical Switches Based on Carbon Nanotubes; Solid-State High-Temperature Power Cells; Fast Offset Laser Phase-Locking System; Fabricating High-Resolution X-Ray Collimators; Embossed Teflon AF Laminate Membrane Microfluidic Diaphragm Valves; Flipperons for Improved Aerodynamic Performance; System Estimates Radius of Curvature of a Segmented Mirror; Refractory Ceramic Foams for Novel Applications; Self-Deploying Trusses Containing Shape-Memory Polymers; Fuel-Cell Electrolytes Based on Organosilica Hybrid Proton Conductors; Molecules for Fluorescence Detection of Specific Chemicals; Cell-Detection Technique for Automated Patch Clamping; Redesigned Human Metabolic Simulator; Compact, Highly Stable Ion Atomic Clock; LiGa(OTf)(sub 4) as an Electrolyte Salt for Li-Ion Cells; Compact Dielectric-Rod White-Light Delay Lines; Single-Mode WGM Resonators Fabricated by Diamond Turning; Mitigating Photon Jitter in Optical PPM Communication; MACOS Version 3.31; Fiber-Optic Determination of N2, O2, and Fuel Vapor in the Ullage of Liquid-Fuel Tanks; Spiking Neurons for Analysis of Patterns; Symmetric Phase-Only Filtering in Particle-Image Velocimetry; Efficient Coupler for a Bessel Beam Dispersive Element; and Attitude and Translation Control of a Solar Sail Vehicle.

Source record↗

Characterising Ion-Irradiated FeCr: Hardness, Thermal Diffusivity and Lattice Strain

Ion-irradiated FeCr alloys are useful for understanding and predicting neutron damage in the structural steels of future nuclear reactors. Previous studies have largely focused on the structure of irradiation induced defects, probed by transmission electron microscopy (TEM), as well as changes in mechanical properties. Across these studies, a wide range of irradiation conditions has been employed on samples with different processing histories, which complicates the analysis of the relationship between defect structures and material properties. Furthermore, key properties, such as irradiation-induced changes in thermal transport and lattice strain, are little explored. Here we present a systematic study of Fe3Cr, Fe5Cr and Fe10Cr binary alloys implanted with 20 MeV Fe3+ ions to nominal doses of 0.01 dpa and 0.1 dpa at room temperature. Nanoindentation, transient grating spectroscopy (TGS) and X-ray micro-beam Laue diffraction were used to study the changes in hardness, thermal diffusivity and strain in the material as a function of damage and Cr content. Our results suggest that Cr leads to an increased retention of irradiation-induced defects, causing substantial changes in hardness and lattice strain. However, thermal diffusivity varies little with increasing damage and instead degrades significantly with increasing Cr content in the material. We find significant lattice strains even in samples exposed to a nominal displacement damage of 0.01 dpa. The defect density predicted from the lattice strain measurements is significantly higher than that observed in previous TEM studies, suggesting that TEM may not fully capture the irradiation-induced defect population. (C) 2020 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

FeCr alloys↗