Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “installed base”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

2020 Cost of Wind Energy Review

This report uses representative utility-scale and distributed wind energy projects to estimate the levelized cost of energy (LCOE) for land-based and offshore wind power plants in the United States. Data and results detailed here are derived from 2020 commissioned plants and representative industry data as well as state-of-the-art modeling capabilities. Modeling is conducted to provide more granular detail on specific cost categories. This report represents the tenth annual installment and is intended to provide insight into current component-level costs as well as a basis for understanding variability in wind energy LCOE across the country.

17 WIND ENERGY↗

Unified Universal Control and Coordination of Inverter-Based Resources, and Validation for a PV + Battery Hybrid Plant

As renewable energy deployment grows, hybrid power plants (HPPs) combining photovoltaic (PV) and battery systems must evolve to offer both energy and grid stability services. These systems typically include a mix of grid-following (GFL) and grid-forming (GFM) inverters, presenting unique coordination and control challenges. This Department of Energy–funded project developed and validated a Unified Universal Control and Coordination (UUCC) framework for such PV + battery hybrid plants, enabling seamless and stable operation, including ultrafast black start, autonomous synchronization, and robust frequency and voltage regulation, under different grid conditions. The project significantly advanced the understanding of inverter-based resource (IBR) control by developing and validating three complementary system-level approaches for hybrid GFL/GFM operation: 1. A combined Virtual Resistance (VR)-based GFL and Virtual Oscillator Control (VOC)-based GFM method, where each inverter type is governed by a specialized control strategy. Together, these achieve stable, fast-response coordination, eliminating inrush current and enabling smooth black start and grid synchronization across a wide range of grid strengths. 2. A Deadbeat-based UUCC strategy, which uses discrete-time, switching-cycle-level control for both GFL and GFM inverters. This approach replaces traditional PI/PLL control with a control parameter-free, high-bandwidth framework that supports stable LVRT and instantaneous synchronization under all conditions. 3. A benchmark comparison with Siemens’ commercial GFM microgrid controller, which provided a fast baseline platform. The commercial approach decoupled v & f control was implemented on a commercial microgrid controller.The baseline commercial benchmark helped highlight superior transient response and black start performance offered by the deadbeat and VOC approaches. These technical contributions offer substantial improvements over conventional inverter control schemes, which often rely on slow phase-locked loop (PLL)-based synchronization, require careful control parameters tuning, and prone to unstable in weak grids with GFL inverters and in stiff grid with GFM inverters therefore challenging for hybrid GFL+GFM under all grid conditions. The deadbeat-based UUCC framework enables simpler, faster, and more robust operation of hybrid IBR systems using wide-bandgap (WBG) devices such as SiC power semiconductors. The rapid expansion of hybrid distributed energy resources (DERs), including residential and commercial PV-BESS installations such as Tesla Powerwall, PV with vehicle-to-grid (V2G) capability, and other integrated configurations, presents complex operational challenges for medium-voltage radial distribution feeders. These networks are subject to frequent disturbances such as faults, switching operations, rapid reclosing sequences, and feeder reconfigurations, all of which introduce dynamic stress on IBRs. In addition, planned feeder segmentation and deliberate islanding for resilience will require DERs that can autonomously perform blackstart, establish voltage and frequency references, and resynchronize with the main grid. The advanced deadbeat-based UUCC control and blackstart functionalities developed in this project directly address these requirements, enabling decentralized and autonomous operation of inverter-dominated DERs in distribution systems under a wide range of fault and reconfiguration scenarios. From a public benefit perspective, these innovations enable more reliable and cost-effective integration of renewable energy into distribution networks. The ability to autonomously black start and stabilize grids under varying grid conditions support accelerates recovery from outages and support decentralized resilient energy systems. By reducing system complexity and improving performance, this project lays critical groundwork for future inverter-dominated power grids that are clean, reliable, and accessible to all.

14 SOLAR ENERGY↗

Development of Wireless Power Technology for Use in Electrochromic Window Retrofit Applications

Electrochromic (EC) windows, often referred to as smart windows, have the ability to adjust their tint in response to electrical signals, thereby controlling the amount of sunlight and heat entering a building. This dynamic modulation can lead to significant energy savings by reducing the reliance on artificial lighting and minimizing the load on heating, ventilation, and air conditioning (HVAC) systems. However, the widespread adoption of electrochromic window technology, especially in existing buildings, faces challenges, particularly concerning the installation cost associated with the need for electrical wiring to power and control the EC glass (tinting). In this project, GuRu Wireless demonstrated that it’s mmWave-based wireless power energy transfer technology can provide the necessary power for operation of electrochromic windows, wirelessly, and address the wiring challenges of electrochromic windows in retrofit applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The EGS Collab Project: Learnings from Experiment 1

The primary objective of the EGS Collab Project sponsored by DOE is to increase the understanding needed to efficiently implement enhanced geothermal systems (EGS). One goal of the EGS Collab project is to create a collaborative research environment in which to study stimulation of crystalline rock at the 10 meter scale. Key to this effort is the collection of high quality data to allow comparison to numerical coupled process models in an effort to build confidence in the codes and modeling techniques used. In response to this, the EGS Collab team has created an underground test bed at the Sanford Underground Research Facility (SURF) in Lead SD at a depth of approximately 1.5 km to examine hydraulic fracturing (Experiment 1). We are currently designing a second test bed aimed at investigating shear stimulation (Experiment 2). At the Experiment 1 location, we have characterized our host rock using laboratory testing and numerous field-based geophysical and geological techniques, and created a well-instrumented test bed to allow us to carefully monitor stimulation events and flow tests. In addition to the installed geophysical sensors, we have used tracer tests, differences in the ambient microbial communities at flow collection locations, and cold water injection to inform us about dynamic flow pathways. In Experiment 1, we have hydraulically stimulated the host rock in a number times at several locations in one well, creating new fractures that connect to existing fractures between the injection and production boreholes. We have performed long-term ambient and chilled water injection tests as an analog to EGS, and have monitored system changes resulting from these water injections through geophysical monitoring, flow and pressure measurements, tracer tests, and microbiology. Here, we summarize the tests performed, issues identified including poroelastic and thermoelastic effects, Joule-Thomson effects, restarting effects, indications of flow channeling, and the primary learnings from Experiment 1.

Enhanced Geothermal Systems, EGS Collab, stimulati↗

Distributed Coaxial Cable Sensors for In-Situ Condition Based Monitoring of Coal-Fired Boiler Tubes

The increasing contributions of renewable energy sources present new challenges to the operation and maintenance of the existing coal-fired power plants. One of the major operational risks is the unexpected failure of superheater boiler tubes, leading to the most unplanned power plant outrages. The boiler tube failure is difficult to predict due to the harsh operating environments. Therefore, condition-based monitoring (CBM) with a reliable high temperature sensor becomes necessary to produce a meaningful assessment of the health condition of boiler tubes and their remaining lifetime. In this work, the stainless-steel and quartz coaxial cable sensor (SSQ-CCS) is proposed for in-situ distributed monitoring of the boiler tube temperatures in existing coal-fired power plants. Comprehensive tests have been conducted with an in-house testing facility at Clemson University to study and evaluate the sensors’ performance in the temperature range of 100℃ to 600℃. The results indicated that the measurement resolution of the SSQ-CCS sensor is better than 1℃, and the drift is less than 2% over long-period testing. Meanwhile, multi-physics finite element analysis has been conducted to optimize the design and evaluate the safety of the SSQ-CCS temperature sensor under various operational conditions. Based on the performance obtained in the laboratory-scale testing, a field test has been implemented at a power plant. Four SSQ-CCS temperature sensors were installed for in-situ monitoring of the temperatures of a power plant’s superheat tube assembles. The data acquisition system has been successfully set up and collected sensing signals for more than three months. The sensing signals have been post-processed, and the monitored temperature history through the SSQ-CCS temperature sensor has been validated and compared with the conventional high temperature thermal couple data.

Jiao, Xinyu↗

Hub and Spoke Modeling to support Agile Combat Employment

Here, the 2022 National Defense Strategy (NDS) shifts focus primarily to the People’s Republic of China (PRC) as the pacing challenge, with acknowledgement of the other threats. President Joe Biden introduced the updated version by stating the U.S. is living in a decisive decade. While the country does not know when the next conflict will happen, leadership believes it will happen soon and the DoD is preparing for this eventuality in the Indo-Pacific region by rethinking operations and concepts. Traditionally, large, fixed installations have been the primary means of operating and generating airpower for the United States Air Force (USAF). Additionally, the service has the capabilities to establish contingency locations based on two primary criteria: a runway and a water source. However, policies and strategy must be updated to create a more agile and dispersed force.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Smart Refractory Sensors Development for Corrosion and Erosion Monitoring in High Temperature Systems

To optimize the operation and functioning of high temperature systems such as slagging gasifiers, coal boilers and glass/steel melters, it is important to monitor corrosion and erosion of refractory used in such systems. Corrosion test strategies are generally based on continuous gravimetric and chemical reactivity monitoring at operational temperatures (750°-1500°C). Both thermocouples and failure sensors and arrays would be useful to monitor the health of any refractory or coatings in these systems. Many of such type of sensors are installed into the systems through open access ports within the refractory; however, there are some disadvantages of this approach where corrosive/erosive gas and molten materials can penetrate and compromise the system. The current work presents the development and performance demonstration of smart refractory with embedded high temperature sensors such as thermocouples, thermistors, and various spallation/crack monitoring sensors, which may be used within a variety of refractory brick in different high temperature processes and applications. The main feature of this technology is that electroceramic based sensors are embedded into smart refractory without significantly impact to the intrinsic properties of the refractory. This technology circumvents the need to insert an isolated monolithic, stand-alone sensor into the refractory via an access port. This technological approach guarantees the integrity and the chemical stability of the materials used in the sensor fabrication within the harsh environment and does not introduce molten material (such as slag) penetration pathways within the refractory. One interesting and important aspect of this innovation is that these embedded sensors can be used to in situ monitoring processes such as chemical reactions and at the same time give information and a deeper understanding of the corrosion and erosion process of the refractory within the system. As stated above, the objective of our work is to develop high-temperature sensors composed of electroceramic materials that are chemically stable at high temperatures (750°-1500°C) and high pressures (up to 1000 psi) that can be used in monitoring corrosion and erosion process in refractory used in high energy systems. The high-temperature sensors investigated in this work were composed of various oxide composites directly embedded into the refractory oxides. The composites used for this work were synthesized by a mixed-oxide route. Metal oxides were inserted within a matrix material composed of refractory oxides (Al2O3, ZrO2, etc.). The physical and electrical properties were specifically manipulated by altering the level of percolation of the conductive species (metal oxides) within the refractory constituent (refractory oxide). Prior to the development of the high-temperature sensors, the oxides composites developed in this study were sintered up to 1600°C under oxidizing atmosphere in order to investigate densification, microstructural evolution, phase development, and their thermoelectrical performance as a function of the composition. The 4-point DC conductivity measurements were performed between 100°-1500°C. The sensors were fabricated from the composite materials by 3D-printing or screen-printing methods into the refractory brick during the consolidation process. An example of one of these embedded sensors consisted of an electroceramic-based thermocouple fabricated with two separate oxide composite compositions which were patterned to produce a couple within the interior of a refractory matrix. The thermocouple successfully displayed thermoelectric voltage trend (as a function of temperature), and the voltage was 220.0 mV around 1400 °C. Corrosion tests on the refractory embedded sensors were performed. To evaluate corrosion in the refractory brick an in-house glass composition was prepared and pressed into pellets and delivered into a pre-cut cavity in the brick. Corrosion experiments results showed the glass penetrated the brick over a 90 h period, and the penetration of the glass through the brick could be monitored by both an amperometric and voltametric based sensor. With this experiment, it was demonstrated that the embedded sensor could dynamically monitor the corrosion process.

20 FOSSIL-FUELED POWER PLANTS↗

Bi-Level Adaptive Storage Expansion Strategy for Microgrids Using Deep Reinforcement Learning

Battery energy storage (BES) is a versatile resource for the secure and economic operation of microgrids (MGs). Prevailing stochastic optimization-based approaches for BES expansion planning for MGs are computationally complicated. This work proposes a data-driven bi-level multi-period BES expansion planning framework to determine the siting, sizing, and timing of BES installations. The proposed planning framework unifies deep reinforcement learning (DRL) and linear programming, thereby decoupling the determinations for the integer and continuous decision variables in two time scales, respectively. In the upper level, a rainbow DRL agent with quantile regression is trained to provide dynamic planning policies to accommodate stochastic renewable energy resources (RESs), load, and battery price changes efficiently. Further, the lower level computes the optimal operation of MGs with frequency constraints to hedge the islanding contingency. The two levels communicate with one another by exchanging storage configuration and operating expenses in order to accomplish the shared goal of minimizing investment and operation costs. Comparative case studies on an MG are carried out to demonstrate the superiority of the proposed DRL-based solution to the mixed-integer linear programming counterpart on efficiency, scalability, and adaptability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EVI-LOCATE User Manual

One of the longest stages in the deployment of electric vehicle supply equipment (EVSE) is the initial planning of the infrastructure itself. Engineers and fleet experts from the National Renewable Energy Laboratory (NREL) have supported dozens of charging infrastructure site plans over the past couple decades, including the generation of site schematics, determinations of electric capacity, and estimates for likely costs. As the market for electric vehicles (EVs) has matured, this approach should no longer require a time and personnel intensive process. In order to shorten the time taken to develop site plans and cost estimates, NREL developed a tool that fleet managers, facility managers, electricians, EVSE installers, and members of the public can use to develop initial schematics and ballpark pricing for charging station installations. The Electric Vehicle Infrastructure - Locally Optimized Charger Assessment Tool and Estimator (EVI-LOCATE) provides a structured and consistent way for users to enter information about their planned EVSE project in a relatively simple web-based format. EVI-LOCATE then calculates electrical equipment capacity, wiring runs, and project costs. It produces a site diagram optimized around surface characteristics with differential trenching costs for softscape such as grass compared to hardscape such as asphalt that can be adjusted by users in the tool. It also stores the resulting site plans and costs in a dashboard for access at a later date, including plan revisions if necessary. This document guides users through the EVI-LOCATE screens and associated questions. It contains tip text boxes throughout on how best to interface with the tool and find additional information or context. The appendices contain the assumptions and calculations underpinning the tool. Much of the information for EVI-LOCATE was gathered through industry engagements with EVSE installers, invoices from completed EVSE installations, Gordian's RS Means construction data, and the General Services Administration blanket purchase agreement for EVSE. For a visual tutorial of the tool, users can watch EVI-LOCATE Step-by-Step Video. The tool itself is available at https://evi-locate.nrel.gov.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Time calibration and synchronization of the scintillation light detection system in ICARUS-T600

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently taking data in the Short Baseline Neutrino (SBN) program at Fermilab (U.S.A.) to search for a possible LSND-like sterile neutrino signal at Δm 2 ≈ 1 eV 2 with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced by the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths installation, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of genuine neutrino interactions. The correct time reconstruction of events requires the precise knowledge of the delay of each PMT channel and a good synchronization of recording electronics, this last based on fast sampling digitizers. To achieve a time resolution better than 1 ns, we perform three consecutive timing corrections deployed at different stages of the optical data flow. Results demonstrate the capability of the ICARUS-T600 light detection system to allow a precise reconstruction of the temporal evolution of each event occurring in the detector and the association of neutrino events with the bunched structure of BNB.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microcam: A Low Power and Privacy Preserving Multi-modal Platform for Occupancy Detection (Final Report)

Heating, ventilation, and air conditioning (HVAC) consumes a significant portion of the energy used in buildings. Much of this is wasted energy, used when buildings are either not occupied at all, or occupied well under their maximum design conditions. This project has focused on residential occupancy detection to autonomously control HVAC systems and save energy. Limitations of existing occupancy sensors include one or more of the following: (i) they employ sensors or algorithms that are not able to detect stationary occupants; (ii) they cannot classify the source of the motion (such as a pet); (iii) depending on the camera resolution and employed algorithms, they do not allow for embedded or onboard computation, and require external or cloud-based processing; (iv) many algorithms developed for camera-based systems are sensitive to lighting changes, and thus prone to missed detections or false alarms; (v) Most existing systems depend on adjustment of settings for different scenarios, complicating self-commissioning; (vi) they cannot provide high enough accuracy; (vii) they are costly; (viii) they are not battery-powered, thus limiting ease of use and installation. In this project, Syracuse University and its partner SRI have developed a low-cost, high accuracy, standalone residential occupancy sensing platform, referred to as the MicroCam, to address all of the aforementioned challenges. MicroCam can operate on typical alkaline batteries without relying on the “cloud” or external computing resources, and consists of low-power, Artificial Intelligence (AI)-based, IoT platforms. Each platform has multi-modal sensors and can process motion, audio and video data, and send binary occupancy result to a lead platform. All sensor data is processed locally on platforms, and the only transmitted data is the binary occupancy state. In addition, preliminary work has been done on images wherein occupants are not discernable. Thus, MicroCam is a standalone solution preserving privacy of the occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Error field correction strategies in preparation to MAST-U operation

In magnetic fusion devices, unwanted non-axisymmetric magnetic field perturbations, known as error fields (EF), can have detrimental effects on plasma stability and confinement. Such EFs may originate from several sources, such as axi-symmetric coil misalignments, coil feeds, 3D structures in the wall surrounding the plasma, presence of ferromagnetic materials near the plasma surface, blanket materials in future devices. To minimize their impact on plasma performance and on the available operational space, it is important to identify the EF sources and develop EF control strategies. MAST Upgrade (MAST-U) is a spherical tokamak which will operate in the near future after a series of enhancements from the previous MAST experiment. To deliver a machine with EF amplitude low enough to allow a high quality experimental programme, systematic analysis of the intrinsic EF sources has been carried out for poloidal eld (P) and divertor (D) coils. To deliver a machine with EF amplitude low enough to allow a high quality experimental programme, systematic analysis of the intrinsic EF sources has been carried out for poloidal field (P) and divertor (D) coils, whose magnetic eld measurements were available when writing this paper. Such measurements reveal that P and D coils are 3D deformed and thus are responsible for intrinsic EFs, with mainly n=1 and n=2 toroidal mode numbers. In preparation to MAST-U operation, both passive and active EF control strategies have been adopted for n=1 and n=2 EFs compensation. Passive EF control consisted of installing finely each D and P coil within MAST-U device so as to minimize the intrinsic n=1 EF amplitude. The optimal coil alignment has been determined based on magnetic eld measurements and the corresponding 3D electro-magnetic modelling, and envisaged coil shift and tilt of 3.2 mm and 0.7 mrad, respectively, in the case of P coil named P4. Conversely, active control will be use during MAST-U operation to reduce the n=2 EF which is associated mainly with P4 and P5, as well. Since these coils have been re-used from the MAST device, studies attempting n=2 EF control, based on MAST plasmas, have been modelled utilizing the MARS-F code to interpret experimental results in MAST and to give hints for future n=2 EF control studies in MAST-U. Here, a model-based control set for n=2 EF control has been identified which would allow for the minimization of rotation braking, of the resonant magnetic field at the q=2 and of the plasma displacement in MAST-U, simultaneously.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Environmental and economic optima of solar home systems design: A combined LCA and LCC approach

Here, we compare the economic and environmental optimal design of Solar Home Systems (SHSs) and explore the role of economic incentives (such as tariffs and technology costs) in approximating the two optima. To achieve that, we present a methodology for the environmental and economic evaluation of grid-connected SHSs: user-scale electric systems involving a photovoltaic (PV) power system and a battery energy storage system. The proposed methodology is based on a mixed integer linear programming (MILP) optimization, life cycle assessment and life cycle costing. This methodological framework is applied to a case study involving a typical SHS installation in Italy. The results of the environmental optimal design brought to the evaluation of a 3.25 kW PV assisted by 8.66 kWh of nickel cobalt manganese batteries, whereas the costs of the SHS are minimized by a small PV system (less than 1 kW). Results underline that the environmental optimal configurations rely on battery technologies, which entails a significant cost compared to the grid connection. In contrast, the economic optimal design solutions is less impactful than the grid mix both from an environmental and economic points of view. Thanks to a reduction of batteries and PV costs, the environmental impact of the economic optimal design is expected to decrease in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Versatile, Full-featured Search Functionality for Indico

Indico, CERN’s popular open-source tool for event management, is in widespread use among facilities that make up the HEP community. It is extensible through a robust plugin architecture that provides features such as search and video conferencing integration. In 2018, Indico version 2 was released with many notable improvements, but without a full-featured search functionality that could be implemented easily outside of CERN. At both Fermi and Brookhaven National Laboratories, the user community viewed the lack of this popular feature as a significant impediment to deployment of the new software. In the meantime, CERN embarked upon a major redesign of their core search service, one that would also necessitate a rewrite of the Indico search interface. Seeing this pressing need, the two US labs decided to collaborate, with assistance from the CERN development team, on a project to develop the requisite search functionality for the larger user community. The resulting design exploits the simplified schema defined in the new CERN Search micro-service, based on Invenio and Elasticsearch, while still providing a flexible path to implementation for alternative backend search services. It is intended to provide a software package that can be installed easily and used out of the box, by anyone at any site. This paper will discuss the design choices and architectural challenges, and provide an overview of the deployment and use of these new plugins.

Constanta, Penelope↗

First degraded beams in the CEBAF injector

The electron beam degrader in the Continuous Electron Beam Accelerator Facility (CEBAF) injector at Jefferson Lab serves to generate electron beams with transverse emittance over 10x the nominal values, with the ultimate goal of using degraded electron beams to measure machine acceptance. Electron beams are degraded through multiple scattering in thin carbon foils, and maximum transverse emittance is defined through two collimating apertures. The degrader device was installed in late 2024, with commissioning and first beams on degrader targets during the 2025 physics run. We report on first operation of the degrader device. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under contract DE-AC05-06OR23177.

Sy, A. [Thomas Jefferson National Accelerator Faci↗

Alpha Spectrometry Results for Groundwater Samples Collected in Northern Iraq and a Summary of the Environmental Setting of the Adaya Burial Site

The Radiation Protection Center (RPC) of the Iraqi Ministry of Environment continues to evaluate the potential health impacts associated with the Adaya Burial Site, which is located 33 kilometers (20.5 miles) southwest of Mosul. This report documents the radiological analyses of 16 groundwater samples collected from wells located in the vicinity of the Adaya Burial Site and at other sites in northern Iraq. The Adaya Burial Site is a high-risk dump site because a large volume of radioactive material and contaminated soil is located on an unsecure hillside above the village of Tall ar Ragrag. The uranium activities for the 16 water samples in northern Iraq are considered to be naturally occurring and do not indicate artificial (man-made) contamination. With one exception, the alpha spectrometry results for the 16 wells that were sampled in 2019 indicate that the water quality concerning the three uranium isotopes (Uranium-233/234, Uranium-235/236, and Uranium-238) was acceptable for potable purposes (drinking and cooking). However, Well 7 in Mosul had a Uranium-233/234 activity concentration that slightly exceeded the World Health Organization guidance level. Eight of the 16 wells are located in the villages of Tall ar Ragrag and Adaya and had naturally occurring uranium concentrations. Wells in the villages of Tall ar Ragrag and Adaya are located near the Adaya Burial Site and should be sampled on an annual schedule. The list of groundwater analytes should include metals, total uranium, isotopic uranium, gross alpha/beta, gamma spectroscopy, organic compounds, and standard water quality parameters. Our current understanding of the hydrogeologic setting in the vicinity of the Adaya Burial Site is solely based on villager's domestic wells, topographic maps, and satellite imagery. To better understand the hydrogeologic setting, a Groundwater Monitoring Program needs to be developed and should include the installation of twelve groundwater monitoring wells in the vicinity of Tall ar Ragrag and the Adaya Burial Site. Characterization of the limestone aquifer and overlying alluvium is needed. RPC should continue to support health assessments for the villagers in Tall ar Ragrag and Adaya. Collecting samples for surface water (storm water), airborne dust, vegetation, and washway sediment should be conducted on a routine basis. Human access to the Adaya Burial Site needs to be strictly limited. Livestock access on or near the burial site needs to be eliminated. The surface-water exposure pathway is likely a greater threat than the groundwater exposure pathway. Installation of a surface-water diversion or collection system is recommended in order to reduce the potential for humans and livestock to come in contact with contaminated water and sediment. To reduce exposure to villagers, groundwater treatment should be considered if elevated uranium or other contaminants are detected in drinking water. Installing water-treatment systems would likely be quicker to accomplish than remediation and excavation of the Adaya Burial Site. The known potential for human exposure to uranium and metals (such as arsenic, chromium, selenium, and strontium) at the Adaya Burial Site is serious. Additional characterization , mitigation, and remediation efforts should be given a high priority.

54 ENVIRONMENTAL SCIENCES↗

Solar Automated Permit Processing Software for Distributed PV (Cooperative Research and Development Final Report, CRADA Number CRD-19-00825)

NREL and its project partners built and commercialized the novel Solar Automated Permitting Processing Plus (SolarAPP+) software platform that delivers instant residential rooftop solar permits. The tool provides installers with a standard portal for entering permit information for residential solar systems across all Authorities Having Jurisdiction (AHJs) using SolarAPP+, thereby providing a streamlined plan review form, transparency into permitting timelines, and required specifications. The project has proven to reduce permitting timelines from as many as 20 business days to zero, delivering solar projects faster in the four participating AHJs using the platform. Streamlining permitting timelines, all else equal, results in consumers installing their systems and reducing their electricity bills faster. The continued expansion of SolarAPP+ features and adoption nationwide will expand the benefits of the SolarAPP+ beyond the current user base.

14 SOLAR ENERGY↗

Understanding neutrinos with accelerator beams and liquid argon time-projection chambers: ICARUS and DUNE

A global program of experiments has worked towards characterizing neutrino oscillation over the past few decades. However, important parameters remain to be measured, and mysteries remain to be elucidated. Current and upcoming experiments are targeting the open questions and probing the consistency of the neutrino oscillation paradigm. Likewise, the liquid argon (LAr) time-projection chamber (TPC) has emerged as a sensitive particle detection technology for neutrino experiments. A current generation of LAr TPC detectors are being used to study neutrinos while also gaining important experience in operating and analyzing with this technology. SBND, MicroBooNE, and ICARUS have collected or are collecting data from beams at Fermilab (near Chicago) to explore the possibility of a sterile neutrino and/or other beyond Standard Model (BSM) physics. SBND and ICARUS will be used to conduct a two-detector analysis as part of the Short Baseline Neutrino (SBN) Program. Additionally, these detectors are enabling important neutrino interaction studies necessary to prepare for the next generation of oscillation experiments. One such oscillation experiment that will come online over the next years is the Deep Underground Neutrino Experiment (DUNE), which will install multiple 10 kiloton LAr TPCs underground in South Dakota (south of Saskatchewan) to conduct oscillation measurements with neutrinos originating in a beamline at Fermilab. A detector complex will be installed at Fermilab as well, to study the beam before the expected flavour oscillations. This “near detector” will also employ a LAr TPC, with a segmented and pixel-based design, as well as other technologies to constrain uncertainties in the oscillation measurement by characterizing the beam and neutrino interactions. This talk will discuss the ICARUS and DUNE experiments, the LAr TPC detector technology, and the efforts to realize and leverage these experiments to better understand the properties of neutrinos.