Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Cleaning Images with Gaussian Process Regression

Many approaches to astronomical data reduction and analysis cannot tolerate missing data: corrupted pixels must first have their values imputed. This paper presents astrofix, a robust and flexible image imputation algorithm based on Gaussian process regression. Through an optimization process, astrofix chooses and applies a different interpolation kernel to each image, using a training set extracted automatically from that image. It naturally handles clusters of bad pixels and image edges and adapts to various instruments and image types. For bright pixels, the mean absolute error of astrofix is several times smaller than that of median replacement and interpolation by a Gaussian kernel. We demonstrate good performance on both imaging and spectroscopic data, including the SBIG 6303 0.4 m telescope and the FLOYDS spectrograph of Las Cumbres Observatory and the CHARIS integral-field spectrograph on the Subaru Telescope.

42 ENGINEERING↗

IMAGING HIGH SPEED PARTICLES IN EXPLOSIVE DRIVEN BLAST WAVES

This research describes a new application of a commercially available particle image velocimetry (PIV) instrument adapted for imaging particles in a blast wave. Powder was dispersed through the PIV light sheet using a right circular cylindrical charge containing aluminum powder filled in the annular space between the explosive core and exterior paper tube wall of the charge. Images acquired from each shot showed particle agglomeration and unique structures with the smaller particle diameters having developed structured appearances.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectrally and Radiometrically Stable Wide-Band on Board Calibration Source for In-Flight Data Validation in Imaging Spectroscopy Applications

The quality of the quantitative spectral data collected by an imaging spectrometer instrument is critically dependent upon the accuracy of the spectral and radiometric calibration of the system. In order for the collected spectra to be scientifically useful, the calibration of the instrument must be precisely known not only prior to but during data collection. Thus, in addition to a rigorous in-lab calibration procedure, the airborne instruments designed and built by the NASA/JPL Imaging Spectroscopy Group incorporate an on board calibrator (OBC) system with the instrument to provide auxiliary in-use system calibration data. The output of the OBC source illuminates a target panel on the backside of the foreoptics shutter both before and after data collection. The OBC and in-lab calibration data sets are then used to validate and post-process the collected spectral image data. The resulting accuracy of the spectrometer output data is therefore integrally dependent upon the stability of the OBC source. In this paper we describe the design and application of the latest iteration of this novel device developed at NASA/JPL which integrates a halogen-cycle source with a precisely designed fiber coupling system and a fiber-based intensity monitoring feedback loop. The OBC source in this Airborne Testbed Spectrometer was run over a period of 15 hours while both the radiometric and spectral stabilities of the output were measured and demonstrated stability to within 1% of nominal.

visible spectrometers↗

A poloidal high- k scattering system for NSTX-U

A previous 5-channel tangential high-k scattering system is being replaced by an 8-channel, poloidal high-k scattering system on the National Spherical Torus eXperiment Upgrade (NSTX-U) device located in Princeton, NJ, USA. The 693 GHz poloidal scattering system replaces a 280 GHz tangential scattering system to study high-k electron density fluctuations on NSTX-U, thereby considerably enhancing planned turbulence physics studies by providing a measurement of the k θ -spectrum of both electron temperature gradient (ETG) and ion temperature gradient (ITG) modes. Two approaches to generating the 693 GHz probe beam are under development: an optically-pumped far-infrared (FIR) laser that generates ~50 mW, and a compact gyrotron that can potentially generate in excess of 5 W. Large aperture optics collect radiation scattered from density fluctuations in the plasma core at 8 simultaneous scattering angles ranging from 2 to 15° corresponding to poloidal wavenumbers that extend to >40 cm -1 . Finally, steerable launch optics coupled with receiver optics mounted on a 5-axis receiver carriage allow the scattering volume to be placed radially from r/a = 0.3 out to the pedestal region (r/a ~ 0.99) and translated horizontally as needed to satisfy wavenumber matching.

47 OTHER INSTRUMENTATION↗

Mining for Strong Gravitational Lenses with Self-supervised Learning

We employ self-supervised representation learning to distill information from 76 million galaxy images from the Dark Energy Spectroscopic Instrument Legacy Imaging Surveys’ Data Release 9. Targeting the identification of new strong gravitational lens candidates, we first create a rapid similarity search tool to discover new strong lenses given only a single labeled example. We then show how training a simple linear classifier on the self-supervised representations, requiring only a few minutes on a CPU, can automatically classify strong lenses with great efficiency. We present 1192 new strong lens candidates that we identified through a brief visual identification campaign and release an interactive web-based similarity search tool and the top network predictions to facilitate crowd-sourcing rapid discovery of additional strong gravitational lenses and other rare objects: github.com/georgestein/ssl-legacysurvey.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of spin-scan imaging for outer planets missions: Executive summary

The development and characteristics of spin-scan imagers for interplanetary exploration are discussed. The spin-scan imaging photopolarimeter instruments of Pioneer 10 and 11 are described. In addition to the imaging function, the instruments are also used in a faint-light mode to take sky maps in both radiance and polarization. The performance of a visible-infrared spin-scan radiometer (VISSR), which operates in both visible and infrared wavelengths, is reported.

Russell, E. E.↗

Backscatter measurements for NIF ignition targets (invited)

Backscattered light via laser-plasma instabilities has been measured in early NIF hohlraum experiments on two beam quads using a suite of detectors. A full aperture backscatter system and near backscatter imager (NBI) instrument separately measure the stimulated Brillouin and stimulated Raman scattered light. Both instruments work in conjunction to determine the total backscattered power to an accuracy of ~15%. In order to achieve the power accuracy we have added time-resolution to the NBI for the first time. This capability provides a temporally resolved spatial image of the backscatter which can be viewed as a movie.

42 ENGINEERING↗

AVIRIS onboard data handling and control

The timing and flow of detector and ancillary data for the Airborne Visible/Infrared imaging spectrometer (AVIRIS) are controlled within the instrument by its digital electronics assembly. In addition to providing detector and signal chain timing, the digital electronics receives, formats, and rate-buffers digitized science data; collects and formats ancillary (calibration and engineering) data; and merges both into a single tape record. Overall AVIRIS data handling is effected by a combination of dedicated digital electronics to control instrument timing, image data flow, and data rate buffering and a microcomputer programmed to handle real-time control of instrument mechanisms and the coordinated preparation of ancillary data.

Steinkraus, Ronald E.↗

AVIRIS onboard data handling and control

The timing and flow of detector and ancillary data for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are controlled within the instrument by its digital electronics assembly. In addition to providing detector and signal chain timing, the digital electronics receives, formats, and rate-buffers digitized science data; collects and formats ancillary (calibration and engineering) data; and merges both into a single tape record. Overall AVIRIS data handling is effected by a combination of dedicated digital electronics to control instrument timing, image data flow, and data rate buffering and a microcomputer programmed to handle real-time control of instrument mechanisms and the coordinated preparation of ancillary data.

Steinkraus, Ronald E.↗

Pre-Launch Calibration and Validation of the Airborne Hyper-Angular Rainbow Polarimeter (AirHARP) Instrument

The Airborne Hyper-Angular Rainbow Polarimeter (AirHARP) is a new imaging polarimeter instrument capable of sampling a single Earth target from up to 120 viewing angles, in four spectral channels, and in three linear polarization states across a 114° field of view (FOV). AirHARP is telecentric in the image space and simultaneously images three linear polarization states with no moving parts. These two aspects of the design allow for a simple and efficient quantitative calibration. Using coefficients derived at the center of the lens and the detector flatfields, we can calibrate the entire AirHARP sensor in a variety of laboratory, field, and space environments. We show that this telecentric calibration technique yields a 1σ absolute uncertainty of 0.25 % in degree of linear polarization (DOLP) in the laboratory for all channels and for pixels around the optical axis. To validate across the FOV, we compare our multi-angle reflectance and polarization data with the Research Scanning Polarimeter (RSP) over targets sampled during the NASA Aerosol Characterization from Polarimeter and Lidar (ACEPOL) campaign. We use the error-normalized difference technique to estimate how well the instruments compare relative to their error models. We find that AirHARP and the RSP reasonably agree for reflectance and DOLP within 2 standard deviations of their mutual uncertainty at 550, 670, and 870 nm and over a limited set of ocean and desert scenes. This calibration technique makes the Hyper-Angular Rainbow Polarimeter (HARP) design attractive for new spaceborne climate missions: HARP CubeSat (2020–2022), HARP2 (2024–) on the NASA Plankton, Aerosol, Cloud, ocean Ecosystem (PACE), and beyond.

Airborne Hyper-Angular Rainbow Polarimeter↗

Far Ultraviolet Imaging from the Image Spacecraft: System Design - 1

Direct imaging of the magnetosphere by the IMAGE spacecraft A,ill be supplemented by observation of the global aurora, the footprint of magnetospheric regions. To assure the simultaneity of these observations and tile measurement of the magnetospheric back-round neutral gas density, the IMAGE satellite instrument complement includes three Far Ultraviolet (FUV) instruments. In tile wavelength region 120-1 90 nm. a downward-viewing aurora imager is only minimally contaminated sunlight, scattered from clouds and ground, and radiance of the aurora observed in a nadir viewing geometry can be observed in the presence of the high-latitude day-low. Tile Wideband Imaging Camera (WIC) will provide broadband ultraviolet images of the aurora for maximum spatial and temporal resolution by imaging the LBH N2 bands of the aurora. The Spectrographic Imager (SI), a monochromatic imager, will image different types of aurora, filtered by wavelength. By measuring the Doppler-shifted Lyman-alpha, the proton-induced component of the aurora will be imaged separately. Finally, the GEO instrument will observe the distribution of the geocoronal emission, which is a measure of the neutral background density source of the charge exchange in the magnetosphere. The FUV instrument complement looks radially outward from the rotating IMAGE satellite and, therefore, it spends only a short time observing tile aurora and the Earth during, each spin. Detailed descriptions of the WIC, Si, GEO, and their individual performance validations are discussed in companion papers. This paper summarizes the system requirements and system design approach taken to satisfy the science requirements. One primary requirement is to maximize photon collection efficiency and use efficiently tile short time available foe exposures. The FUV auroral imagers WIC and SI both have wide fields of view and take data continuously as the auroral region proceeds through the field of view. To minimize data volume, multiple images are taken and electronically co-added by suitably shifting each image to compensate for the spacecraft rotation. In order to minimize resolution loss, the images have to be distortion-corrected in real time foe both WIC and Si prior to co-adding. The distortion correction is accomplished using high-speed look Lip tables that are pre-generated by least square fitting to polynomial functions by the on-orbit processor. The instruments were calibrated individually while on stationary platforms, mostly in vacuum chambers as described in the companion papers. Extensive -round-based testing was performed with visible and near UV simulators mounted oil a rotating platform to estimate their on-orbit performance. The predicted instrument system performance is summarized and some of the preliminary data formats are shown.

Mende, S. B.↗

System-on-chip integrated circuit technology applications on the DIII-D tokamak for multi-field measurements

Several mm-wave diagnostics on the DIII-D tokamak provide multi-scale and multi-dimensional measurements of plasma profile evolution and turbulence fluctuations. Mm-wave fusion plasma diagnostics that adopt system-on-chip integrated circuit technology can provide better space utilization, flexible installation, and improved sensitivity. In order to further extend this technology for additional fusion facilities with a higher toroidal magnetic field, V-band (55–75 GHz) and F-band (90–140 GHz) chips for Microwave Imaging Reflectometer (MIR) and Electron Cyclotron Emission Imaging (ECEI) instruments are developed and tested in the Davis Millimeter Wave Research Center (DMRC). Current measurement data show that correlation between these SoC-based diagnostic instruments with other state-of-the-art diagnostics enables co-located multi-field turbulence fluctuation measurement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatial resolution measurements of the advanced radiographic capability x-ray imaging system at energies relevant to Compton radiography

Compton radiography provides a means to measure the integrity, ρR and symmetry of the DT fuel in an inertial confinement fusion implosion near peak compression. Upcoming experiments at the National Ignition Facility will use the ARC (Advanced Radiography Capability) laser to drive backlighter sources for Compton radiography experiments and will use the newly commissioned AXIS (ARC X-ray Imaging System) instrument as the detector. AXIS uses a dual-MCP (micro-channel plate) to provide gating and high DQE at the 40–200 keV x-ray range required for Compton radiography, but introduces many effects that contribute to the spatial resolution. Experiments were performed at energies relevant to Compton radiography to begin characterization of the spatial resolution of the AXIS diagnostic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydroscanner: Instrumentation for Water Ingress Imaging in Photovoltaic Module Packaging Materials

A new iteration of the Hydroscanner prototype was designed and built during the execution of the contract. Compared to the previous designs, the communication port was changed from ethernet to USB C, since it provides a more seamless integration as a peripheral unit. An additional advantage is that one single port can be used for both communication and power up of the infrared camera. Although the power requirements are higher than the typical amount provided by a laptop computer, the camera can be run as a peripheral from a docking station when connected to a thunderbolt charging port. The software interface was modified to accommodate two imaging modes, an 8-bit and 14-bit image display. The 8-bit images use a custom colorization scheme that divides all pixels in the image into bins of equal width, such that images containing a wide range of brightness display the intermediate pixel intensities in greyscale values that enhance the contrast. The 14-bit images provide the direct readout from the focal plane array of the camera and can be saved as a text file for later processing in other software packages (MATLAB, Python).

47 OTHER INSTRUMENTATION↗

Correlation Between Low Frequency Auroral Kilometric Radiation (AKR) and Auroral Structures

Auroral Kilometric Radiation (AKR) is a radio wave emission that has long been associated with auroral activity. AKR is normally observed in the frequency range from -60 - 600 kHz. Low frequency AKR (or LF-AKR) events are characterized as a rapid extension of AKR related emissions to 30 kHz or lower in frequency for typically much less than 10 minutes. LF-AKR emissions predominantly occur within a frequency range of 20 kHz - 30 kHz, but there are LF-AKR related emissions that reach to a frequency of 5 kHz. This study correlates all instances of LF-AKR events during the first four years of observations from the IMAGE spacecraft's Radio Plasma Imager (WI) instrument with auroral observations from the wideband imaging camera (WIC) onboard IMAGE. The correlation between LF-AKR occurrence and WIC auroral observations shows that in the 295 confirmed cases of LF-AKR emissions, bifurcation of the aurora is seen in 74% of the cases. The bifurcation is seen in the dusk and midnight sectors of the auroral oval, where AKR is believed to be generated. The polarization of these LF-AKR emissions has yet to be identified. Although LF-AKR may not be the only phenomena correlated with bifurcated auroral structures, bifurcation will occur in most instances when LF-AKR is observed. The LF-AKR emissions may be an indicator of specific auroral processes sometimes occurring during storm-time conditions in which field-aligned density cavities extend a distance of perhaps 5-6 RE tailward from the Earth for a period of 10 minutes or less.

Paxamickas, Katherine A.↗

Analysing the Advantages of High Temporal Resolution Geostationary MSG SEVIRI Data Compared to Polar Operational Environmental Satellite Data for Land Surface Monitoring in Africa

Since 1972, satellite remote sensing of the environment has been dominated by polar-orbiting sensors providing useful data for monitoring the earth s natural resources. However their observation and monitoring capacity are inhibited by daily to monthly looks for any given ground surface which often is obscured by frequent and persistent cloud cover creating large gaps in time series measurements. The launch of the Meteosat Second Generation (MSG) satellite into geostationary orbit has opened new opportunities for land surface monitoring. The Spinning Enhanced Visible and Infrared Imager (SEVIRI) instrument on-board MSG with an imaging capability every 15 minutes which is substantially greater than any temporal resolution that can be obtained from existing polar operational environmental satellites (POES) systems currently in use for environmental monitoring. Different areas of the African continent were affected by droughts and floods in 2008 caused by periods of abnormally low and high rainfall, respectively. Based on the effectiveness of monitoring these events from Earth Observation (EO) data the current analyses show that the new generation of geostationary remote sensing data can provide higher temporal resolution cloud-free (less than 5 days) measurements of the environment as compared to existing POES systems. SEVIRI MSG 5-day continental scale composites will enable rapid assessment of environmental conditions and improved early warning of disasters for the African continent such as flooding or droughts. The high temporal resolution geostationary data will complement existing higher spatial resolution polar-orbiting satellite data for various dynamic environmental and natural resource applications of terrestrial ecosystems.

Fensholt, R.↗

Planning In-Flight Calibration for XRISM

The XRISM X-ray observatory will fly two advanced instruments, the Resolve high-resolution spectrometer and the Xtend wide-field imager. These instruments, particularly Resolve, pose calibration challenges due to the unprecedented combination of spectral resolution, spectral coverage, and effective area, combined with a need to characterize the imaging fidelity of the full instrument system to realize the mission’s ambitious science goals. We present the status of the XRISM in-flight calibration plan, building on lessons from Hitomi and other X-ray missions. We present a discussion of targets and observing strategies to address the needed calibration measurements, with a focus on developing methodologies to plan a thorough and flexible calibration campaign and provide insight on calibration systematic error. We also discuss observations that exploit Resolve’s spectral resolution to calibrate atomic codes, and cross-calibration between the XRISM instruments and with other observatories.

Eric D Miller↗

Advanced X-ray Astrophysics Facility (AXAF) instrumentation

The instrumentation planned for the Advanced X-ray Astrophysics Facility (AXAF), a space-based observation platform for the 1990s, is described. The AXAF will feature a grazing incidence telescope at the end of the observatory and four independently selected instruments at the other end, including: a CCD imaging spectrometer; a Bragg crystal spectrometer; and two transmission grating spectrometers located directly behind the telescope to detect first order spectral images. The instruments are currently in the definition phase to be followed by design and development starting in the late 1980s. A detailed schematic diagram of the Bragg crystal imaging spectrometer is provided.

Winkler, C. E.↗