Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

The CO Emission in the Taffy Galaxies (UGC 12914/15) at 60 pc Resolution. I. The Battle for Star Formation in the Turbulent Taffy Bridge

We present Atacama Large Millimeter/submillimeter Array observations at a spatial resolution of $0^{"}_{.}2$ (60 pc) of CO emission from the Taffy galaxies (UGC 12914/5). The observations are compared with narrowband Paα, mid-IR, radio continuum and X-ray imaging, plus optical spectroscopy. The galaxies have undergone a recent head-on collision, creating a massive gaseous bridge that is known to be highly turbulent. The bridge contains a complex web of narrow molecular filaments and clumps. The majority of the filaments are devoid of star formation, and fall significantly below the Kennicutt–Schmidt relationship for normal galaxies, especially for the numerous regions undetected in Paα emission. Within the loosely connected filaments and clumps of gas we find regions of high velocity dispersion that appear gravitationally unbound for a wide range of likely values of X CO . Like the "Firecracker" region in the Antennae system, they would require extremely high external dynamical or thermal pressure to stop them dissipating rapidly on short crossing timescales of 2–5 Myr. We suggest that the clouds may be transient structures within a highly turbulent multiphase medium that is strongly suppressing star formation. Despite the overall turbulence in the system, stars seem to have formed in compact hotspots within a kiloparsec-sized extragalactic H ii region, where the molecular gas has a lower velocity dispersion than elsewhere, and shows evidence for a collision with an ionized gas cloud. Like the shocked gas in the Stephan's Quintet group, the conditions in the Taffy bridge shows how difficult it is to form stars within a turbulent, multiphase, gas.

79 ASTRONOMY AND ASTROPHYSICS↗

Transient Radio Emission from Low-redshift Galaxies at z < 0.3 Revealed by the VLASS and FIRST Surveys

We present the discovery of a sample of 18 low-redshift (z < 0.3) galaxies with transient nuclear radio emission. These galaxies are not detected or are weakly detected in the Faint Images of the Radio Sky at Twenty cm survey, performed from 1993–2009, but have brightened significantly in radio flux (by a factor of ≳5) in the epoch I (2017–2019) observations of the Very Large Array Sky Survey (VLASS). All 18 galaxies have been detected in VLASS epoch II observations, from 2020–2021, from which the radio flux has been found to evolve slowly (with variability amplitudes of ≳40%) over a period of about 3 yr. 15 galaxies have been observed in the Rapid ASKAP Continuum Survey, and a flat or inverted spectral slope between 888 MHz and 3 GHz is found. Based on the Sloan Digital Sky Survey spectra taken before the radio brightening, 14 of the 18 galaxies can be classified as LINERs or normal galaxies with weak or no nuclear activity. Most galaxies are red and massive, with more than half having central black hole masses above 10 8 M ⊙ . We find that only one galaxy in our sample displays an optical flare lasting for at least two months, with a long decay in the infrared light curve that can be explained as the dust-heated echo emission of a central optical flare, such as a stellar tidal disruption event. We discuss several possibilities for the transient radio emission and conclude that it is likely associated with a newborn radio jet triggered by short sporadic fueling of a supermassive black hole. Such a scenario can be tested with further multifrequency radio observations of these sources, via measuring their radio flux variability and spectral evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark Energy Survey Year 6 Results: MagLim++ Lens Sample Selection and Measurements of Galaxy Clustering

Galaxy clustering is a sensitive probe of the expansion history and growth of structure of the universe, and key degeneracies can be broken by combining these data with measurements of cosmic shear and galaxy-galaxy lensing (a so-called 3$\times$2pt analysis). The largest and least biased statistical samples of galaxies for use in clustering analyses can be collected photometrically through large imaging surveys. However, selecting clean photometric subsamples for cosmology are crucial for avoiding contamination that can bias cosmological constraints. Here we present the MagLim++ galaxy sample, selected to optimize for cosmological constraining power and incorporating an array of novel quality cuts to identify and remove residual contamination. This sample comes from the full six years of observations from the Dark Energy Survey. We present measurements of the two-point angular clustering ($w(θ)$) of 9,186,205 galaxies distributed over 4031 sq. degrees and in six tomographic redshift bins centered at $\bar{z}\approx$ [0.31, 0.44, 0.62, 0.78, 0.90, 1.01]. These measurements are used as part of the 3$\times$2pt and other DES Y6 legacy cosmological analyses in companion works. We describe the battery of null tests and mitigation schemes implemented to address observational, astrophysical, and methodological systematics in the analysis. The resulting $w(θ)$ measurements have a S/N = 149 (90.2 for linear scales only), which we use to place galaxy-clustering-only constraints on the matter density of the Universe, $Ω_m=0.311^{+0.023}_{-0.035}$, and amplitude of galaxy clustering in each redshift bin, $b_iσ_8=[1.16^{+0.04}_{-0.06},\ 1.40^{+0.04}_{-0.06},\ 1.57^{+0.04}_{-0.06},\ 1.59^{+0.04}_{-0.05},\ 1.50^{+0.04}_{-0.05},\ 1.74^{+0.06}_{-0.08}]$.

Weaverdyck, N. [BCCP, Berkeley; UC, Berkeley; LBL,↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Low latency optical-based mode tracking with machine learning deployed on FPGAs on a tokamak

Active feedback control in magnetic confinement fusion devices is desirable to mitigate plasma instabilities and enable robust operation. Optical high-speed cameras provide a powerful, non-invasive diagnostic and can be suitable for these applications. Here, in this study, we process high-speed camera data, at rates exceeding 100 kfps, on in situ field-programmable gate array (FPGA) hardware to track magnetohydrodynamic (MHD) mode evolution and generate control signals in real time. Our system utilizes a convolutional neural network (CNN) model, which predicts the n = 1 MHD mode amplitude and phase using camera images with better accuracy than other tested non-deep-learning-based methods. By implementing this model directly within the standard FPGA readout hardware of the high-speed camera diagnostic, our mode tracking system achieves a total trigger-to-output latency of 17.6 μs and a throughput of up to 120 kfps. This study at the High Beta Tokamak-Extended Pulse (HBT-EP) experiment demonstrates an FPGA-based high-speed camera data acquisition and processing system, enabling application in real-time machine-learning-based tokamak diagnostic and control as well as potential applications in other scientific domains.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ionizing radiation effects in SONOS-based neuromorphic inference accelerators

Here, we evaluate the sensitivity of neuromorphic inference accelerators based on Silicon-Oxide-Nitride-Oxide-Silicon (SONOS) charge trap memory arrays to total ionizing dose (TID) effects. Data retention statistics were collected for 16 Mbit of 40 nm SONOS digital memory exposed to ionizing radiation from a Co-60 source, showing good retention of the bits up to the maximum dose of 500 krad(Si). Using this data, we formulate a rate-equation-based model for the TID response of trapped charge carriers in the ONO stack, and predict the effect of TID on intermediate device states between ‘program’ and ‘erase’. This model is then used to simulate arrays of low-power, analog SONOS devices that store 8-bit neural network weights and support in situ matrix-vector multiplication. We evaluate the accuracy of the irradiated SONOS-based inference accelerator on two image recognition tasks – CIFAR-10 and the challenging ImageNet dataset – using state-of-the-art convolutional neural networks, such as ResNet-50. We find that across the datasets and neural networks evaluated, the accelerator tolerates a maximum TID between 10 krad(Si) and 100 krad(Si), with deeper networks being more susceptible to accuracy losses due to TID.

43 PARTICLE ACCELERATORS↗

Operation of a Modular 3D-Pixelated Liquid Argon Time-Projection Chamber in a Neutrino Beam

The 2x2 Demonstrator, a prototype for the Deep Underground Neutrino Experiment (DUNE) liquid argon (LAr) Near Detector, was exposed to the Neutrinos from the Main Injector (NuMI) neutrino beam at Fermi National Accelerator Laboratory (Fermilab). This detector is a prototype of a new modular design for a liquid argon time-projection chamber (LArTPC), comprising a two-by-two array of four modules, each further segmented into two optically isolated LArTPCs. The 2x2 Demonstrator features a number of pioneering technologies, including a low-profile resistive field shell to establish drift fields, native 3D ionization pixelated imaging, and a high-coverage dielectric light readout system. The 2.4-tonne active mass detector is flanked upstream and downstream by supplemental solid-scintillator tracking planes, repurposed from the MINERvA experiment, which track ionizing particles exiting the argon volume. The antineutrino beam data collected by the detector over a 4.5 day period in 2024 include over 30,000 neutrino interactions in the LAr active volume—the first neutrino interactions reported by a DUNE detector prototype. During its physics-quality run, the 2x2 Demonstrator operated at a nominal drift field of 500 V/cm and maintained good LAr purity, with a stable electron lifetime of approximately 1.25 ms. This paper describes the detector and supporting systems, summarizes the installation and commissioning, and presents the initial validation of collected NuMI beam and off-beam self-triggers. In addition, it highlights observed interactions in the detector volume, including candidate muon antineutrino events.

47 OTHER INSTRUMENTATION↗

Uncovering surface plasmon optical resonances in nanohole arrays through interferometric photoemission electron microscopy

In this work, the role of surface plasmon polaritons (SPPs) in nanohole array optical extinction spectra is explored using a time-resolved technique capable of isolating the air/metal interfacial SPP contribution to the typical Fano profile in optical transmission curves. A pair of interferometrically locked broad-band femtosecond pulses is used to launch SPPs from lithographically patterned plasmonic nanohole arrays. SPPs launched in the co- and counter-propagating directions are probed using a third probe pulse in a photoemission electron microscope. Using this approach, we record interferometric SPP–SPP linear autocorrelations that selectively report on the resonances of SPPs launched from arrays of varying pitches and hole diameters. Aside from advancing an approach to selective SPP spectroscopy, we illustrate that resonant coupling in the counter-propagating direction may be exploited to control the spatial, temporal, and spectral characteristics of SPPs. For the counter-propagating direction, we show that tuning the array pitch near the fundamental plasmon resonance generates color-tuned (~770–820 nm), narrow bandwidth SPPs, and the bandwidth may be controlled by changing the ratio of pitch to hole diameter. The SPP resonances we recover through Fourier transforms of the interferometric autocorrelations shed light on the classical problem of Fano interference in nanohole array extinction spectra.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Super-Resolution Ptychography with Small Segmented Detectors

To overcome the spatial resolution limit set by aperture-limited diffraction in traditional scanning transmission electron microscopy, microscopists have developed ptychography enabled by iterative phase retrieval algorithms and high-dynamic-range pixel array detectors. Current detector designs are limited by the data rate off chip, so a high-pixel-count detector has a proportionally lower frame rate than the few-segment detectors used for differential phase contrast (DPC) imaging. This slower acquisition speed leads to heightened vulnerability to scan noise, drift, and potential sample damage. This creates opportunities for repurposing fast segmented detectors for ptychography by trading a reduction in reciprocal space pixels for an increase in real space pixels. Here, we explore a strategy of oversampling in real space and instead apply detector pixel upsampling during the reconstruction process. Further, we demonstrate the viability of achieving super-resolution ptychography on thin objects using only 2 × 2 detector pixels, surpassing the resolution of integrated DPC (iDPC) imaging. With optimization using simulated datasets and experiments on MoTe 2 /WSe 2 bilayer moiré superlattices, we achieved super-resolution ptychography reconstructions under rapid acquisition conditions (37.5 pA, 1 μs dwell time), yielding over 50% improvements in contrast and information limit compared to annular dark field and iDPC imaging on the same detectors.

2D materials↗

A Cryogenic Readout IC with 100 KSPS in-Pixel ADC for Skipper CCD-in-CMOS Sensors

The Skipper CCD-in-CMOS Parallel Read-Out Circuit (SPROCKET) is a mixed-signal front-end design for the readout of Skipper CCD-in-CMOS image sensors. SPROCKET is fabricated in a 65 nm CMOS process and each pixel occupies a 50$\mu$m $\times$ 50$\mu$m footprint. SPROCKET is intended to be heterogeneously integrated with a Skipper-in-CMOS sensor array, such that one readout pixel is connected to a multiplexed array of nine Skipper-in-CMOS pixels to enable massively parallel readout. The front-end includes a variable gain preamplifier, a correlated double sampling circuit, and a 10-bit serial successive approximation register (SAR) ADC. The circuit achieves a sample rate of 100 ksps with 0.48 $\mathrm{e^-_{rms}}$ equivalent noise at the input to the ADC. SPROCKET achieves a maximum dynamic range of 9,000 $e^-$ at the lowest gain setting (or 900 $e^-$ at the lowest noise setting). The circuit operates at 100 Kelvin with a power consumption of 40 $\mu W$ per pixel. A SPROCKET test chip was submitted in September 2022, and test results will be presented at the conference.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solution processed high aspect ratio ultra-long vertically well-aligned ZnO nano scintillators for potential X-ray imaging applications

We report the photon (PL), electron (CL) and X-ray (XEL) induced luminescence characteristics of high aspect ratio ultra-long (~ 50 µm) ZnO nanorods (NRs) and discuss the potential for fast X-ray detection based on the consistent and efficient visible emission (~ 580 nm) from ZnO NRs. Nanostructured ZnO scintillators were rearranged to form a vertically well-aligned NR design in order to help light absorption and coupling resulting in luminescent and fast scintillation properties. The design of the nanorod array combines the key advantages of a low-cost growth technique together with environmentally friendly and widely available materials. A low temperature hydrothermal method was adopted to grow ZnO NRs in one cycle growth and their structural, optical and X-ray scintillation properties were investigated. The relatively short (~ 10 µm) ZnO NRs emitting in the near-band-edge region were found to be almost insensitive to X-rays. On the other hand, the higher XEL response of long ZnO NRs, which is a key parameter for evaluation of materials to be used as scintillators for high quality X-ray detection and imaging, along with a decay time response in the order of ns confirmed promising scintillation properties for fast and high-resolution X-ray detector applications.

47 OTHER INSTRUMENTATION↗

W-band system-on-chip electron cyclotron emission imaging system on DIII-D

Monolithic, millimeter wave “system-on-chip” (SoC) technology has been employed in heterodyne receiver integrated circuit radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature profile and fluctuation evolution diagnostics. Here, a prototype module operating in E-band (72-80 GHz) was first employed in a 2 x 10 element array that demonstrated significant improvements over the previous quasi-optical Schottky diode mixer arrays during the 2018 operational campaign of the DIII-D tokamak. For compatibility with International Thermonuclear Experimental Reactor (ITER) relevant scenarios on DIII-D, the SoC ECEI system was upgraded with 20 horn-waveguide receiver modules. Each individual module contains a University of California at Davis designed W-band (75 -110 GHz) receiver die that integrates a broadband low noise amplifier (LNA), a double balanced down-converting mixer, and a x4 multiplier on the local oscillator (LO) chain. A x2 multiplier and two IF amplifiers are packaged and selected to further boost the signal strength as well as downconvert the signal frequency. The upgraded W-band array exhibits > 30 dB additional gain and 20x improvement in noise temperature comparing with the previous Schottky diode radio frequency (RF) mixer input systems; an internal 8 times multiplier chain is used to bring down the LO frequency below 12 GHz, thereby obviating the need for a large aperture for quasi-optical LO coupling and replacing it with coaxial connectors. The horn-waveguide shielding housing avoids out-of-band noise interference on each individual module. The upgraded ECEI system plays an important role for absolute electron temperature evolution and fluctuation measurements for edge and core region transport physics studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution multicontrast tomography with an X-ray microarray anode–structured target source

Multicontrast X-ray imaging with high resolution and sensitivity using Talbot–Lau interferometry (TLI) offers unique imaging capabilities that are important to a wide range of applications, including the study of morphological features with different physical properties in biological specimens. The conventional X-ray TLI approach relies on an absorption grating to create an array of micrometer-sized X-ray sources, posing numerous limitations, including technical challenges associated with grating fabrication for high-energy operations. We overcome these limitations by developing a TLI system with a microarray anode–structured target (MAAST) source. The MAAST features an array of precisely controlled microstructured metal inserts embedded in a diamond substrate. Using this TLI system, tomography of a Drum fish tooth with high resolution and tri-contrast (absorption, phase, and scattering) reveals useful complementary structural information that is inaccessible otherwise. The results highlight the exceptional capability of high-resolution multicontrast X-ray tomography empowered by the MAAST-based TLI method in biomedical applications.

47 OTHER INSTRUMENTATION↗

Automatic Determination of the Weak-Beam Condition in Dark Field X-ray Microscopy

Mechanical properties in crystals are strongly correlated to the arrangement of 1D line defects, termed dislocations. Recently, Dark field X-ray Microscopy (DFXM) has emerged as a new tool to image and interpret dislocations within crystals using multidimensional scans. However, the methods required to reconstruct meaningful dislocation information from high-dimensional DFXM scans are still nascent and require significant manual oversight (i.e. supervision). In this work, we present a new relatively unsupervised method that extracts dislocation-specific information (features) from a 3D dataset (x, y, Φ) using Gram-Schmidt orthogonalization to represent the large dataset as an array of 3-component feature vectors for each position, corresponding to the weak-beam conditions and the strong-beam condition. Finally, this method offers key opportunities to significantly reduce dataset size while preserving only the crystallographic information that is important for data reconstruction.

36 MATERIALS SCIENCE↗

3D tracking of particles in a dusty plasma by laser sheet tomography

The collective behavior of levitated particles in a weakly ionized plasma (dusty plasma) has raised significant scientific interest. This is due to the complex array of forces acting on the particles and their potential to act as in situ diagnostics of the plasma environment. Ideally, the three-dimensional (3D) motion of many particles should be tracked for long periods of time. Typically, stereoscopic imaging using multiple cameras combined with particle image velocimetry is used to obtain a velocity field of many particles, yet this method is limited by its sample volume and short time scales. Here, we demonstrate a different, high-speed tomographic imaging method capable of tracking individual particles. We use a scanning laser sheet coupled to a single high-speed camera. We are able to identify and track tens of individual particles over centimeter length scales for several minutes, corresponding to more than 10 000 frames.

Physics↗

Plasma flows during the ablation stage of an over-massed pulsed-power-driven exploding planar wire array

We characterize the plasma flows generated during the ablation stage of an over-massed exploding planar wire array, fielded on the COBRA pulsed-power facility (1 MA peak current, 250 ns rise time). The planar wire array is designed to provide a driving magnetic field (80–100 T) and current per wire distribution (about 60 kA), similar to that in a 10 MA cylindrical exploding wire array fielded on the Z machine. Over-massing the arrays enables continuous plasma ablation over the duration of the experiment without implosion. The requirement to over-mass on the Z machine necessitates wires with diameters of 75–100μm, which are thicker than wires usually fielded on wire array experiments. To test ablation with thicker wires, we perform a parametric study by varying the initial wire diameter between 33 and 100 μm. The largest wire diameter (100 μm) array exhibits early closure of the cathode-wire gap, while the gap remains open over the duration of the experiment for wire diameters between 33 and 75 μm. Laser plasma interferometry and time-gated extreme-ultraviolet (XUV) imaging are used to probe the plasma flows ablating from the wires. The plasma flows from the wires converge to generate a pinch, which appears as a fast-moving (V≈100kms−1) column of increased plasma density (n¯e≈2×1018cm−3) and strong XUV emission. Finally, we compare the results with three-dimensional resistive-magnetohydrodynamic (MHD) simulations performed using the code GORGON, the results of which reproduce the dynamics of the experiment reasonably well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wide‐Field Bond Quality Evaluation Using Frequency Domain Thermoreflectance with Deep Neural Network Feature Reconstruction

Heterogeneous integration of microelectronic components provides a pathway to improve circuit/component performance; however, this comes with assembly challenges, in particular due to complex interfaces via subsurface bump bonds. The ability of these bonds to transmit electrical signals and conduct heat to the carrier substrate limits component performance. In this work, hyperspectral frequency‐domain thermoreflectance (FDTR) imaging is demonstrated as a robust technique for evaluating the quality of subsurface indium bump bonds in a surrogate microelectronic sample. By performing microscale FDTR imaging with coarse motion image stitching, thermal phase maps that cover a 4 mm by 4 mm field‐of‐view with subsurface feature sensitivity at depths greater than 50 µm are obtained. The resulting FDTR hyperspectral data contains more than three million pixels and reveal the quality of subsurface microbump arrays. Wide‐field analysis of bonded versus gap regions is enabled by deep neural network feature reconstruction, that after training, rapidly provides an interpretable representation of bond quality. Utility of noisy higher frequency FDTR phase maps, i.e., near the computationally predicted sensing depth limit, results in an average prediction error of 11%. Taken together, FDTR with neural network‐based analysis demonstrates subsurface bond monitoring at length scales relevant for heterogeneously integrated microelectronics.

FDTR↗