Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Machine learning informed control systems for extrusion printing processes

Systems and methods for controlling a material extrusion device to extrude a filament of an ink are provided. An extrusion printing control system collects from one or more sensors measurements representing an internal state of material extrusion processing during extrusion of the filament. In addition, the system collects an image of the filament as the filament is extruded. The system applies a classifier to the collected image to generate an image-derived state characterizing the filament. Based on the internal state and the image-derived state, the system estimates a derived state using a model. The system determines control parameters using the model to achieve a desired quality of the filament by minimizing a cost function based on the internal state, the image-derived state, the derived state, and constraints of the material extrusion device. Finally, the system provides the control parameters to a controller of the material extrusion device.

Howell, Brian↗

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active‐Source Seismic Imaging of Fault Re‐Activation and Leakage: An Injection Experiment at the Mt Terri Rock Laboratory, Switzerland

Abstract We conducted a time‐lapse seismic experiment utilizing automated active seismic source and sensor arrays to monitor a reactivated fault within the Opalinus clay formation at the Mont Terri Rock Laboratory (Switzerland), an analog caprock for geologic carbon storage. A series of six brine injections were conducted into the so‐called Main Fault to reactivate it. Seismic instrumentation in five monitoring boreholes on either side of the fault was used to continuously probe changes in P‐wave travel‐times associated with fault displacement and leakage. We performed time‐lapse travel‐time tomography on five hundred sequential data sets; this revealed a zone of decreased P‐wave velocity, up to 16 m/s, during each injection cycle, followed by a velocity increase during shut‐in. These results demonstrate varying elastic property perturbations, both spatially and temporally, along the fault plane during reactivation. We then interpreted these velocity changes in terms of fault dilation induced by pressurized fluids along the fault.

58 GEOSCIENCES↗

SpaceNet 9—Cross-Sensor Alignment of Optical and SAR Imagery

Precise registration of high-resolution synthetic aperture radar (SAR) and optical imagery is necessary for realizing the full potential and benefits of multimodal image analysis. However, two significant challenges presently exist. First, there is a lack of annotated datasets and benchmarks available for high-resolution SAR–optical image registration. Second, an assessment of efficient and reliable image registration methods that can precisely align these modalities is lacking. Here, we present a holistic description of the SpaceNet 9 Challenge and its results. We present a description of the dataset and baseline algorithm along with the results of the challenge, including a description of the winning algorithms. We release the SpaceNet 9 dataset along with open-sourcing the winning algorithms and baseline. The objective of SpaceNet 9 was to compute a dense displacement map that indicates the shift needed to align pixels in an optical image to the pixels in a SAR image. The challenge launched in April 2025 and was active for approximately two months. The top five solutions reduced image alignment error from approximately 34 m to under 13 m for public and private test data, with the best results obtaining a registration error of only 8.5 and 6.7 m on the public testing and private testing dataset, respectively. Usage of pretrained image matching models, robust outlier rejection with RANSAC, and estimating local displacement were common among the top solutions. The results of this challenge provide insight into high-resolution SAR–optical image registration and offer opportunities for future benchmarking in this domain. The baseline algorithm, winning solutions, and datasets are available at https://spacenet.ai/sn9-challenge/.

benchmark datasets↗

Development of Lipid-Coated Semiconductor Nanosensors for Recording of Membrane Potential in Neurons

In the past decade, optical imaging methods have significantly improved our understanding of the information processing principles in the brain. Although many promising tools have been designed, sensors of membrane potential are lagging behind the rest. Semiconductor nanoparticles are an attractive alternative to classical voltage indicators, such as voltage-sensitive dyes and proteins. Such nanoparticles exhibit high sensitivity to external electric fields via the quantum-confine Stark effect. Here we report the development of semiconductor voltage-sensitive nanorods (vsNRs) that self-insert into the neuronal membrane. To facilitate interaction of the nanorods with the membrane, we functionalized their surface with the lipid mixture derived from brain extract. We describe a workflow to detect and process the photoluminescent signal of vsNRs after widefield time-lapse recordings. We also present data indicating that vsNRs are feasible for sensing membrane potential in neurons at a single-particle level. This shows the potential of vsNRs for the detection of neuronal activity with unprecedentedly high spatial and temporal resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Functionalization of nitrogen vacancy-containing nanodiamonds with a metal-organic framework for quantum sensing applications

Nitrogen vacancy (NV)-containing nanodiamonds (NDs) are an important material in applications such as biological imaging, catalysis, and, in particular, quantum sensing. Careful manipulation of the surface coating on NV NDs is essential for both enhancing quantum sensor performance and for tuning selectivity towards specific sensing targets. Here, we demonstrate a simple synthetic approach for functionalizing NV NDs with the zeolitic imidazole framework-8 (ZIF-8) metal–organic framework (MOF), providing a well-ordered, porous scaffold for immobilizing target analytes near the NV ND surface. The composites were structurally characterized by x-ray diffraction, electron microscopy, and X-ray photoelectron spectroscopy, and these results were all consistent with NV NDs fully encapsulated by ZIF-8. Critically, the luminescent properties of the NV NDs, which are vital for quantum sensing experiments such as optically detected magnetic resonance (ODMR), are unchanged by the MOF coating. Moreover, spin relaxometry experiments indicate that the ZIF-8 coating significantly enhances the NV ND spin longitudinal relaxation time T1, a critical quantum parameter for sensing applications. Given the tremendous structural diversity of MOFs, the NV ND@MOF composites are an exciting material class with exciting implications for the development of high-performance quantum sensors.

Crawford, Scott↗

Subtask 1.5 – CO2 Injection Monitoring with an Optimized Scalable, Automated, Semipermanent Seismic Array

The scalable, automated, semipermanent seismic array (SASSA) method is a flexible and relatively cost-effective surface geophysical method for regular time-lapse monitoring of the movement of injected carbon dioxide (CO2) in a reservoir for CO2 enhanced oil recovery (EOR) or geologic CO2 storage operations. It has the advantages of a low-environmental-footprint while monitoring regions of a reservoir from the surface without the need for a regular grid distribution of receivers. Automated data collection is possible. As only time-lapse amplitude changes at the reservoir level due to CO2 movement within the reservoir are monitored, the turnaround time to deliver results from the SASSA method can be short, without the need for long, time-consuming data-processing workflows. As data is collected and processed, incremental information can be provided to the field operator. The Energy & Environmental Research Center (EERC) conducted a SASSA field test from September 2018 to November 2020 in a portion of the Bell Creek Field in Montana, which implemented new CO2 EOR field activities during the study period. Lessons learned from a proof-of-concept study were incorporated to improve the data quality of the SASSA method and demonstrate the viability of the technology. The EERC implemented several enhancements to improve data quality, including 1) an iterative survey design, which allowed placing the receivers in strategic locations where the movement of the CO2 in the reservoir could be tracked with minimum interference by the cultural noise in the study area; 2) the use of powerful seismic sources in the form of surface orbital vibrators, and 3) data acquisition during optimal periods. History-matched reservoir simulation was performed to predict gas saturation and pressure response induced by CO2 injection in the study area. The results were compared with the SASSA-measured responses to CO2 injection as a partial validation technique. A match between the two methods was observed for most of the SASSA points predicted to have intersected a CO2 saturation change. The validated results provide confidence that the SASSA method can be used independently as a CO2 saturation monitoring technique. As data are collected and processed, incremental information can be provided to the field operator. The critical components of the SASSA workflow for a successful application of the method are the following: Iterative survey design with information about CO2 injection activities from the oilfield operator. A detailed CO2 injection plan is the key driver to select the strategic monitoring location of the SASSA sensors. After this information is incorporated in the initial distribution of sources and receivers in the study area, high-resolution satellite images are used to identify ground locations not affected by cultural noise sources, such as power lines, pipelines/flow lines, or roadways. In the next iteration of the survey design, a scouting trip to the study area is needed to understand more details of the noise sources identified in the previous step and the intensity of the field activities that can also generate noise during the monitoring. Integrating the information from the scouting trip into the survey design to select the optimum source and receiver locations is the final step. Noise attenuation. The variety of noise types during seismic monitoring of an oil field is enormous. Tailored noise characterization and processing at a node-by-node level can enhance the performance and sensitivity of the SASSA technique. Future advancements that could improve the efficiency and application of the SASSA technology include: Gaining a better understanding of the noise field produced by the seismic source to aid the choice of receiver location. Surface noise from the source can overwhelm the small signal changes due to CO2 that the SASSA method measures. Improved data-processing workflow to automatically analyze and adapt to dynamic noise conditions associated with industrial settings. This subtask was funded through the EERC–DOE Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE- FE0024233.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Quantitative investigation of sooting dynamics in droplet combustion using an automated image analysis algorithm

This paper reports an image analysis approach using a newly-developed open-source program to extract quantitative measurements of soot volume fraction (SVF) from digital video images of burning n-heptane droplets. The automated program developed in this work can analyze images of fixed and untethered droplets to quantify sooting dynamics. The images analyzed in the program were taken from experiments carried out in the Multi-user Droplet Combustion Apparatus (MDCA) onboard the International Space Station (ISS). In these experiments, video imaging of burning droplets was obtained using backlighting by a laser diode with a wavelength of 653 nm. Here, the light was collimated before it passed through the droplet and soot-containing region, after which the light was then attenuated and projected onto the camera’s sensors. This technique facilitates the measurements of SVF based on the principles of the full field light extinction method (FFLEM). The measurements provide quantitative data that reveal the sooting dynamics of liquid fuels during droplet combustion processes. The analyses of a soot-attenuating image (ISS n-heptane, untethered droplet) at an instant during the burning show that the SVF distribution has a peak at the soot shell location. It then decreases due to soot oxidation when the location is further away from the burning droplet. Regarding temporal effects on the maximum SVF (SVF max ), results show that SVF max first increases after the burning is initiated until a peak value is reached, after which SVF max decreases. The SVF max values identified in this study for n-heptane are quantitatively consistent with previously reported values for fiber-supported droplets and are reached relatively early in the burning history. n-Heptane images are also analyzed to show the effects of initial droplet sizes on the maximum soot volume fraction. Results show that SVF max decreases with increasing initial droplet size, which is consistent with visual observations of less soot formed and dimmer flame brightness as Do increases.

42 ENGINEERING↗

Data and scripts associated with the manuscript "A Hydrogeophysical Framework to Assess Infiltration During a Simulated Ecosystem-Scale Flooding Experiment”

This package contains the data and scripts used in "A hydrogeophysical framework to assess infiltration during a simulated ecosystem-scale flooding experiment" (Adebayo et al., 2023). The Geophysics folder contains two subfolders containing Ground Penetrating Radar (GPR) and Electrical Resistivity Imaging (ERI) datasets acquired between August 23 and August 26, 2021. The GPR subfolder contains raw data (Tempest_Project.GPZ) and processed results using the Sensors and Software EKKO Project software. The ERI subfolder contains two additional subfolders named Static and Timelapse. The Static subfolder contains background resistivity datasets acquired before infiltration, both raw and inverted results using the ResIpy code. The Timelapse subfolder contains repeated resistivity datasets acquired during infiltration on two profiles, along with raw and inverted results using the ResIpy code. The Flow model folder contains ATS model simulation files. The Geophysics-informed subfolder contains simulation datasets for two profiles generated using information from the geophysics data. The National_database-informed subfolder contains simulation datasets for two profiles generated using information from a national soil database. Each subfolder contains initial simulation results, multiple ensembles, and final simulation files. The Sensitivity_analysis folder contains the observation files exported from the flow model, notebooks used in running the code, and sensitivity analysis results showing the sensitivity of different parameters over a 48-hour period. We used mutual information-based global sensitivity analysis for the sensitivity analysis, following Jiang et al., 2022. This study shows a novel approach that integrates geophysical data with hydrological modeling to understand subsurface flow during coastal flooding.

54 ENVIRONMENTAL SCIENCES↗

Gain characterization of LGAD sensors with beta particles and 28-MeV protons

Low Gain Avalanche Diodes, also known as LGADs, are widely considered for fast-timing applications in high energy physics, nuclear physics, space science, medical imaging, and precision measurements of rare processes. Such devices are silicon-based and feature an intrinsic gain due to a p + -doped layer that allows the production of a controlled avalanche of carriers, with multiplication on the order of 10–100. This technology can provide time resolution on the order of 20–30 ps, and variants of this technology can provide precision tracking too. The characterization of LGAD performance has so far primarily been focused on the interaction of minimum ionizing particles for high energy and nuclear physics applications. This article expands the study of LGAD performance to highly-ionizing particles, such as 28-MeV protons, which are relevant for several future scientific applications, e.g. in biology and medical physics, among others. These studies were performed with a beam of 28-MeV protons from a tandem Van de Graaff accelerator at Brookhaven National Laboratory and beta particles from a ^90Sr source; these were used to characterize the response and the gain of an LGAD as a function of bias voltage and collected charge. Here, the experimental results are also compared to TCAD simulations.

47 OTHER INSTRUMENTATION↗

Glassy carbon formation from pyrolysis of polymeric coatings on fiber-optic sensors

Deploying fiber-optic sensors in nuclear reactors requires a detailed understanding of radiation effects on the fiber materials and the transmitted signals. Previous work has shown large wavelength shifts in the reflected spectra obtained from polymer-coated fiber-optic temperature sensors exposed to high neutron fluences. The sensor drift resulting from these wavelength shifts cannot be explained by radiation effects on fused silica glass. These shifts are hypothesized to be caused by the conversion of the polymeric fiber coating to a glassy carbon via radiolysis and/or pyrolysis and subsequent radiation-induced compaction. Here, thermal degradation of these polymeric coatings was studied to provide insight into the potential origins of the sensor drift phenomenon. Acrylate- and polyimide-coated fibers were heated under various temperatures (250–1300 °C) and environments (oxidative and inert), and the resulting coating products were characterized via mass-loss data, scanning electron microscope imaging, and Raman spectroscopy. Results suggest that the polymer decomposition product of both coating types, at least under inert conditions, is indeed a glassy carbon. Analytical models that account for radiation-induced glassy carbon coating compaction show significant compressive fiber strains and predicted wavelength shifts that agree well with experimental measurements, providing additional evidence that supports the hypothesized origins of the sensor drift.

36 MATERIALS SCIENCE↗

A globally sampled high-resolution hand-labeled validation dataset for evaluating surface water extent maps

Effective monitoring of global water resources is increasingly critical due to climate change and population growth. Advancements in remote sensing technology, specifically in spatial, spectral, and temporal resolutions, are revolutionizing water resource monitoring, leading to more frequent and high-quality surface water extent maps using various techniques such as traditional image processing and machine learning algorithms. However, satellite imagery datasets contain trade-offs that result in inconsistencies in performance, such as disparities in measurement principles between optical (e.g., Sentinel-2) and radar (e.g., Sentinel-1) sensors and differences in spatial and spectral resolutions among optical sensors. Therefore, developing accurate and robust surface water mapping solutions requires independent validations from multiple datasets to identify potential biases within the imagery and algorithms. However, high-quality validation datasets are expensive to build, and few contain information on water resources. For this purpose, we introduce a globally sampled, high-spatial-resolution dataset labeled using 3 m PlanetScope imagery. Our surface water extent dataset comprises 100 images, each with a size of 1024×1024 pixels, which were sampled using a stratified random sampling strategy covering all 14 biomes. We highlighted urban and rural regions, lakes, and rivers, including braided rivers and coastal regions. We evaluated two surface water extent mapping methods using our dataset – Dynamic World, based on Sentinel-2, and the NASA IMPACT model, based on Sentinel-1. Dynamic World achieved a mean intersection over union (IoU) of 72.16 % and F1 score of 79.70 %, while the NASA IMPACT model had a mean IoU of 57.61 % and F1 score of 65.79 %. Performance varied substantially across biomes, highlighting the importance of evaluating models on diverse landscapes to assess their generalizability and robustness. Our dataset can be used to analyze satellite products and methods, providing insights into their advantages and drawbacks. Our dataset offers a unique tool for analyzing satellite products, aiding the development of more accurate and robust surface water monitoring solutions. The dataset can be accessed via https://doi.org/10.25739/03nt-4f29.

54 ENVIRONMENTAL SCIENCES↗

Miniature fluorescence sensor for quantitative detection of brain tumour

Fluorescence-guided surgery has emerged as a vital tool for tumour resection procedures. As well as intraoperative tumour visualisation, 5-ALA-induced PpIX provides an avenue for quantitative tumour identification based on ratiometric fluorescence measurement. To this end, fluorescence imaging and fibre-based probes have enabled more precise demarcation between the cancerous and healthy tissues. These sensing approaches, which rely on collecting the fluorescence light from the tumour resection site and its “remote” spectral sensing, introduce challenges associated with optical losses. In this work, we demonstrate the viability of tumour detection at the resection site using a miniature fluorescence measurement system. Unlike the current bulky systems, which necessitate remote measurement, we have adopted a millimetre-sized spectral sensor chip for quantitative fluorescence measurements. A reliable measurement at the resection site requires a stable optical window between the tissue and the optoelectronic system. This is achieved using an antifouling diamond window, which provides stable optical transparency. The system achieved a sensitivity of 92.3% and specificity of 98.3% in detecting a surrogate tumour at a resolution of 1 × 1 mm 2 . In conclusion, as well as addressing losses associated with collecting and coupling fluorescence light in the current ‘remote’ sensing approaches, the small size of the system introduced in this work paves the way for its direct integration with the tumour resection tools with the aim of more accurate interoperative tumour identification.

59 BASIC BIOLOGICAL SCIENCES↗

HRPPD photosensors for RICH detectors with a high resolution timing capability

Recently, a new version of DC-coupled High Rate Picosecond Photodetectors (DC-HRPPDs) substantially re-designed for use at the Electron-Ion Collider (EIC) has been developed. A first batch of seven “EIC HRPPDs” was manufactured in early 2024. These HRPPDs are DC-coupled photosensors based on Micro-Channel Plates (MCPs) that have an active area of 104 mm by 104 mm, 32 × 32 direct readout pixel array at a pitch of 3.25 mm, peak quantum efficiency in excess of 30%, exceptionally low dark count rates and timing resolution of 15–20 ps for a single photon detection. As such, these photosensors are very well suited for Ring Imaging CHerenkov (RICH) detectors that can additionally provide high resolution timing capability, especially in a configuration where a detected charged particle passes through the sensor window, which produces a localized flash containing a few dozens of Cherenkov photons in it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spectral Performance of Multilayer Amorphous Selenium and Selenium–Tellurium Photodetectors

The ability to robustly and with scalability detect single photons in the visible spectrum with wavelength resolution would transform many imaging applications. Theoretical studies propose an array of carbon nanotubes (CNTs) functionalized with semiconductor quantum dots (QDs) as a physical realization of such photon sensors. In this work, we report approaches to synthesize these CNT-QD nanostructures using DNA as a smart glue to connect CNTs to QDs.

36 MATERIALS SCIENCE↗

Detecting ionizing radiation using halide perovskite semiconductors processed through solution and alternative methods

We report the direct detection of high-energy radiation such as X-rays and.-rays by semiconductors at room temperature is a challenging proposition that requires remarkably pure and nearly perfect crystals. The emergence of metal halide perovskites, defect-tolerant semiconductors, is reviving hope for new materials in this field after an almost 20 year hiatus. Metal halide perovskites, which combine exceptional optoelectronic properties, versatile chemistry and simple synthesis, are challenging traditional approaches for the development of novel semiconductors for detecting hard radiation. We discuss the relevant physical properties, promising materials, fabrication techniques and device architectures for high-performance, low-cost detectors by targeting next-generation semiconductors for radiation detection. We also present a perspective on the impact of such advances in future medical imaging applications.

36 MATERIALS SCIENCE↗

Upgrade of the gated laser entrance hole imager G-LEH-2 on the National Ignition Facility

A major upgrade has been implemented for the ns-gated laser entrance hole imager on the National Ignition Facility (NIF) to obtain high-quality data for Hohlraum physics study. In this upgrade, the single “Furi” hCMOS sensor (1024 × 448 pixel arrays with two-frame capability) is replaced with dual “Icarus” sensors (1024 × 512 pixel arrays with four-frame capability). Both types of sensors were developed by Sandia National Laboratories for high energy density physics experiments. With the new Icarus sensors, the new diagnostic provides twice the detection area with improved uniformity, wider temporal coverage, flexible timing setup, and greater sensitivity to soft x rays (<2 keV). These features, together with the fact that the diagnostic is radiation hardened and can be operated on the NIF for high neutron yield deuterium–triterium experiments, enable significantly greater return of data per experiment.

47 OTHER INSTRUMENTATION↗

Two 28-nm front-end ASICs for ultra-fine spatial resolution and precision timing to be 3D integrated with 12 LGADs

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (about 10 µm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present two 28 nm CMOS ASIC prototypes, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗