Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

A Region-Growing Segmentation Approach to Delineating Timberline from Satellite-Derived Tree Fractional Cover Products

Timberline marks the transitions from continuous forests to sparse forests and tundra landscapes. As the spatial distribution and dynamics of timberline are closely associated with regional energy and carbon balance, mapping timberline is important to a wide range of environmental and ecological studies. However, current timberline delineation approaches remain under-developed. We proposed an automatic timberline delineation method based on a seeded region-growing segmentation technique and satellite-derived products of tree fractional cover. We applied our approach to the West Siberian Plain and Alaska treeline regions as defined by the Circumpolar Arctic Vegetation Map. The results demonstrate the effectiveness of the proposed method for the accurate delineation of the timberlines that spatially align well with very-high-resolution satellite images. Based on the delineated timberlines, we find regional-scale tree encroachment to be not as substantial as previously reported. The proposed approach can be applied to understanding climate-induced forest responses and inform forest management practices.

Circumpolar Arctic Vegetation Map↗

THE SUBARCSECOND MID-INFRARED VIEW OF LOCAL ACTIVE GALACTIC NUCLEI. III. POLAR DUST EMISSION

Recent mid-infrared (MIR) interferometric observations have shown that in a few active galactic nuclei (AGNs) the bulk of the infrared emission originates from the polar region above the putative torus, where only a little dust should be present. Here, we investigate whether such strong polar dust emission is common in AGNs. Out of 149 Seyferts in the MIR atlas of local AGNs, 21 show extended MIR emission on single-dish images. In 18 objects, the extended MIR emission aligns with the position angle (PA) of the system axis, established by [O iii], radio, polarization, and maser-based PA measurements. The relative amount of resolved MIR emission is at least 40% and scales with the [O iv] fluxes, implying a strong connection between the extended continuum and [O iv] emitters. These results together with the radio-quiet nature of the Seyferts support the scenario that the bulk of MIR emission is emitted by dust in the polar region and not by the torus, which would demand a new paradigm for the infrared emission structure in AGNs. The current low detection rate of polar dust in the AGNs of the MIR atlas is explained by the lack of sufficient high-quality MIR data and the requirements on the orientation, strength of narrow-line region, and distance of the AGNs. The James Webb Space Telescope will enable much deeper nuclear MIR studies with comparable angular resolution, allowing us to resolve the polar emission and surroundings in most of the nearby AGNs.

79 ASTRONOMY AND ASTROPHYSICS↗

The size evolution of star-forming galaxies since z ∼ 7 using ZFOURGE

For the first time, we present the size evolution of a mass-complete (log(M{sub *}/M{sub ⊙}) > 10) sample of star-forming galaxies over redshifts z = 1–7, selected from the FourStar Galaxy Evolution Survey. Observed H-band sizes are measured from the Cosmic Assembly Near-infrared Deep Extragalactic Legacy Survey (CANDELS) Hubble Space Telescope (HST)/F160W imaging. Distributions of individual galaxy masses and sizes illustrate that a clear mass−size relation exists up to z ∼ 7. At z ∼ 7, we find that the average galaxy size from the mass−size relation is more compact at a fixed mass of log(M{sub *}/M{sub ⊙}) = 10.1, with r{sub 1/2,maj}=1.02±0.29 kpc, than at lower redshifts. This is consistent with our results from stacking the same CANDELS HST/F160W imaging, when we correct for galaxy position angle alignment. We find that the size evolution of star-forming galaxies is well fit by a power law of the form r{sub e}=7.07(1+z){sup −0.89} kpc, which is consistent with previous works for normal star-formers at 1 < z < 4. In order to compare our slope with those derived Lyman break galaxy studies, we correct for different IMFs and methodology and find a slope of −0.97 ± 0.02, which is shallower than that reported for the evolution of Lyman break galaxies (LBGs) at z > 4 (r{sub e}∝(1+z){sup −1.2±0.06}). Therefore, we conclude the LBGs likely represent a subset of highly star-forming galaxies that exhibit rapid size growth at z > 4.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutron Capture and Transmission Measurements and Evaluation of 54 Fe at the RPI LINAC [Slides]

This presentation covers neutron capture and transmission measurements and evaluation of 54 Fe (Iron) at the Rensselaer Polytechnic Insitute (RPI) Linear Accelerator (LINAC). Presentation conclusions find that 54 Fe is near its conclusion, covariance matrix generation is needed for both experiments before data is made available and released (Completion by April 2023). RPI will be conducting a full Resolved Resonance Region (RRR) evaluation following release of data (Completion by September 2023). Additionally, the neutron beam imager shows promise in providing an easy way to align samples in the most intense part of the neutron beam and there will be a new evaluation that will offer improvements in crit safety, shielding, and stellar applications.

07 ISOTOPE AND RADIATION SOURCES↗

Design of the polar neutron-imaging aperture for use at the National Ignition Facility

The installation of a neutron imaging diagnostic with a polar view at the National Ignition Facility (NIF) required design of a new aperture, an extended pinhole array (PHA). This PHA is different from the pinhole array for the existing equatorial system due to significant changes in the alignment and recording systems. The complex set of component requirements, as well as significant space constraints in its intended location, makes the design of this aperture challenging. In addition, lessons learned from development of prior apertures mandate careful aperture metrology prior to first use. This paper discusses the PHA requirements, constraints, and the final design. The PHA design is complex due to size constraints, machining precision, assembly tolerances, and design requirements. When fully assembled, the aperture is a 15 mm × 15 mm × 200 mm tungsten and gold assembly. The PHA body is made from 2 layers of tungsten and 11 layers of gold. The gold layers include 4 layers containing penumbral openings, 4 layers containing pinholes and 3 spacer layers. In total, there are 64 individual, triangular pinholes with a field of view (FOV) of 200 μm and 6 penumbral apertures. Each pinhole is pointed to a slightly different location in the target plane, making the effective FOV of this PHA a 700 μm square in the target plane. The large FOV of the PHA reduces the alignment requirements both for the PHA and the target, allowing for alignment with a laser tracking system at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anisotropic seismic-waveform inversion: Application to a seismic velocity model from Eleven-Mile Canyon in Nevada

Accurate imaging and characterization of fracture zones is crucial for geothermal energy exploration. Aligned fractures within fracture zones behave as anisotropic media for seismic-wave propagation. The anisotropic properties in fracture zones introduce extra difficulties for seismic imaging and waveform inversion. We have recently developed a new anisotropic elastic-waveform inversion method using a modified total-variation regularization scheme and a wave-energy-base preconditioning technique. Our new inversion method uses the parameterization of elasticity constants to describe anisotropic media, and hence it can properly handle arbitrary anisotropy. We apply our new inversion method to a seismic velocity model along a 2D-line seismic data acquired at Eleven-Mile Canyon located at the Southern Dixie Valley in Nevada for geothermal energy exploration. Our inversion results show that anisotropic elastic-waveform inversion has potential to reconstruct subsurface anisotropic elastic parameters for imaging and characterization of fracture zones.

15 GEOTHERMAL ENERGY↗

Influence of orbital symmetry on diffraction imaging with rescattering electron wave packets

The ability to directly follow and time-resolve the rearrangement of the nuclei within molecules is a frontier of science that requires atomic spatial and few-femtosecond temporal resolutions. While laser-induced electron diffraction can meet these requirements, it was recently concluded that molecules with particular orbital symmetries (such as pg) cannot be imaged using purely backscattering electron wave packets without molecular alignment. Here, we demonstrate, in direct contradiction to these findings, that the orientation and shape of molecular orbitals presents no impediment for retrieving molecular structure with adequate sampling of the momentum transfer space. We overcome previous issues by showcasing retrieval of the structure of randomly oriented O 2 and C 2 H 2 molecules, with π g and π u symmetries, respectively, and where their ionization probabilities do not maximize along their molecular axes. As a result, while this removes a serious bottleneck for laser-induced diffraction imaging, we find unexpectedly strong backscattering contributions from low-Z atoms.

74 ATOMIC AND MOLECULAR PHYSICS↗

Real-Time Target Position Estimation Using Stereoscopic Kilovoltage/Megavoltage Imaging and External Respiratory Monitoring for Dynamic Multileaf Collimator Tracking

Purpose: To develop a real-time target position estimation method using stereoscopic kilovoltage (kV)/megavoltage (MV) imaging and external respiratory monitoring, and to investigate the performance of a dynamic multileaf collimator tracking system using this method. Methods and Materials: The real-time three-dimensional internal target position estimation was established by creating a time-varying correlation model that connected the external respiratory signals with the internal target motion measured intermittently using kV/MV imaging. The method was integrated into a dynamic multileaf collimator tracking system. Tracking experiments were performed for 10 thoracic/abdominal traces. A three-dimensional motion platform carrying a gold marker and a separate one-dimensional motion platform were used to reproduce the target and external respiratory motion, respectively. The target positions were detected by kV (1 Hz) and MV (5.2 Hz) imaging, and external respiratory motion was captured by an optical system (30 Hz). The beam-target alignment error was quantified as the positional difference between the target and circular beam center on the MV images acquired during tracking. The correlation model error was quantified by comparing a model estimate and measured target positions. Results: The root-mean-square errors in the beam-target alignment that had ranged from 3.1 to 7.6 mm without tracking were reduced to <1.5 mm with tracking, except during the model building period (6 s). The root-mean-square error in the correlation model was submillimeters in all directions. Conclusion: A novel real-time target position estimation method was developed and integrated into a dynamic multileaf collimator tracking system and demonstrated an average submillimeter geometric accuracy after initializing the internal/external correlation model. The method used hardware tools available on linear accelerators and therefore shows promise for clinical implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-181: An Alternative Patient Alignment Tool On TomoTherapy: The First In- Human Megavoltage-Topogram Acquisition

Purpose: To show the first in-human Megavoltage (MV)-Topogram acquisition for the evaluation of the potential for MV-Topogram-based alignment as an alternative to MVCT for reducing dose and imaging time. Methods: A lung cancer patient was enrolled in an ongoing IRB-approved clinical trial at our institute. The patient was set up using the clinical protocol employing positioning lasers. 3.2mm diameter tungsten spheres were placed on the patient’s skin at their alignment tattoos to check surface-based marker concordance between topograms and MVCT. Anterior-Posterior (AP) and lateral (LAT) MV-Topograms were acquired using gantry angles of 0°/90° with a 1mm collimator opening, all MLC leafs open, 4cm/s couch speed, and 12.5s scanning time. The topogram acquisition was immediately followed by the normal MVCT scan acquisition. MV-Topograms were reconstructed from the detector exit-data using in-house developed software. The topograms were also enhanced using contrast-limited adaptive histogram equalization (CLAHE). The MV-Topograms were registered to reference kV-based digitally reconstructed topograms. The localization results were compared against results obtained comparing the clinical MVCT to the kVCT simulation. Results: The shifts using the unenhanced Topograms, enhanced Topograms, and MVCT were (LAT, LONG, VERT, ROLL) (5.8mm, 2.6mm, −5.6mm, 0.34°), (3.9mm, 2.5mm, −2.2mm, 0.65°) and (2.4mm, 1.5mm, −3.0mm, 0.5°), respectively. The magnitude alignment differences between the enhanced Topograms and MVCT were within 1.5 mm and 0.15°. The average MVCT and total Topogram acquisition times were 272.9s ± 31.5s and 46s, respectively. Conclusion: MV-Topograms have the potential for providing equivalent performance with less dose and acquisition time than the traditional MVCT technique. We are evaluating other sites as well as adding patients to develop statistically significant analyses regarding the alignment quality differences. MV-Topograms are likely to be most clinically useful for bony anatomy and radiopaque marker-based alignments. The study was supported by an Accuray Grant.

60 APPLIED LIFE SCIENCES↗

Alignment of sample position and rotation during in situ synchrotron X-ray micro-diffraction experiments using a Laue cross-correlation approach

Laue micro-diffraction has proven to be able to reveal material properties at the sub-grain scale for many polycrystalline materials and is now routinely available at several synchrotron facilities, providing an approach for nondestructive three-dimensional probing of the microstructures and mechanical states of materials. However, for in situ experiments, maintaining the positioning of the sample throughout the experiment, to achieve a good alignment of the characterized volumes, is a challenging issue. The aim of the present work is to address this problem by developing an approach based on digital image correlation of focused-beam Laue diffraction patterns. The method uses small changes in the diffraction signal as a focused X-ray beam is scanned over a surface region to allow corrections to be made for both sample lateral movement and rotation. The method is demonstrated using a tensile deformation experiment on an Al sample with 2.5 µm average grain size. The results demonstrate an accuracy of 0.5 µm for sample position registration and a precision in sample rotation of ~0.01°. Finally, the proposed method is fast to implement and does not require the use of additional surface markers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-237: Deformable Image Registration and Deformed Dose Composite for Volumetric Evaluation of Multimodal Gynecological Cancer Treatments

Purpose: Radiotherapy plans for patients with cervical cancer treated with EBRT followed by HDR brachytherapy are optimized by constraining dose to organs at risk (OARs). Risk of treatment related toxicities is estimated based on the dose received to the hottest 2cc (D2cc) of the bladder, bowel, rectum, and sigmoid. To account for intrafractional variation in OAR volume and positioning, a dose deformation method is proposed for more accurate evaluation of dose distribution for these patients. Methods: Radiotherapy plans from five patients who received 50.4Gy pelvic EBRT followed by 30Gy in five fractions of HDR brachytherapy, using split-ring and tandem applicators, were retrospectively evaluated using MIM Software version 6.0. Dose accumulation workflows were used for initial deformation of EBRT and HDR planning CTs onto a common HDR planning CT. The Reg Refine tool was applied with user-specified local alignments to refine the deformation. Doses from the deformed images were transferred to the common planning CT. Deformed doses were scaled to the EQD2, following the linear-quadratic BED model (considered α/β ratio for tumor as 10, and 3 for rest of the tissues), and then combined to create the dose composite. MIM composite doses were compared to the clinically-reported plan assessments based upon the American Brachytherapy Society (ABS) guidelines for cervical HDR brachytherapy treatment. Results: Bladder D2cc exhibited significant reduction (−11.4%±3.85%, p< 0.02) when evaluated using MIM deformable dose composition. Differences observed for bowel, rectum, and sigmoid D2cc were not significant (−0.58±7.37%, −4.13%±13.7%, and 8.58%±4.71%, respectively and p>0.05 for all) relative to the calculated values used clinically. Conclusion: Application of deformable dose composite techniques may lead to more accurate total dose reporting and can allow for elevated dose to target structures with the assurance of not exceeding dose to OARs. Further study into deformable dose composition and correlation with clinical outcomes is warranted.

60 APPLIED LIFE SCIENCES↗

Giant terahertz polarization rotation in ultrathin films of aligned carbon nanotubes

For easy manipulation of polarization states of light for applications in communications, imaging, and information processing, an efficient mechanism is desired for rotating light polarization with a minimum interaction length. Here, we report giant polarization rotations for terahertz (THz) electromagnetic waves in ultrathin ( ∼ <#comment/> 45 n m ), high-density films of aligned carbon nanotubes. We observed polarization rotations of up to ∼ <#comment/> 20 ∘ <#comment/> and ∼ <#comment/> 110 ∘ <#comment/> for transmitted and reflected THz pulses, respectively. The amount of polarization rotation was a sensitive function of the angle between the incident THz polarization and the nanotube alignment direction, exhibiting a “magic” angle at which the total rotation through transmission and reflection becomes exactly 90°. Our model quantitatively explains these giant rotations as a result of extremely anisotropic optical constants, demonstrating that aligned carbon nanotubes promise ultrathin, broadband, and tunable THz polarization devices.

Baydin, Andrey (ORCID:0000000225673506)↗

Controlled epitaxial graphene growth within removable amorphous carbon corrals

We address the question of control of the silicon carbide (SiC) steps and terraces under epitaxial graphene on SiC and demonstrate amorphous carbon (aC) corrals as an ideal method to pin SiC surface steps. aC is compatible with graphene growth, structurally stable at high temperatures, and can be removed after graphene growth. For this, aC is first evaporated and patterned on SiC, then annealed in the graphene growth furnace. There at temperatures above 1200 °C, mobile SiC steps accumulate at the aC corral that provide effective step flow barriers. Aligned step free regions are thereby formed for subsequent graphene growth at temperatures above 1330 °C. Atomic force microscopy imaging supports the formation of step-free terraces on SiC with the step morphology aligned to the aC corrals. Raman spectroscopy indicates the presence of good graphene sheets on the step-free terraces.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The geometry of signal space: a case study of direct mapping between seismic signals and event distribution

SUMMARY Under favourable circumstances, seismic waveforms corresponding to an ensemble of events related by a common, spatially distributed process collectively exhibit a regular, signal-space geometry. When events in the ensemble have a common, or nearly common, source mechanism, this geometry is a distorted image of the distribution of events in the source region. The signal-space image can be visualized using a relatively simple waveform alignment and projection operation. Ensemble waveform correlation measurements can be inverted to estimate the distribution of the events in the source region, up to an arbitrary rotation, reflection and scaling, with residual distortion. We demonstrate these concepts with synthetic waveforms and with observations of long-wall mining induced seismicity for which substantial ground truth information is available. Our experience with these data has implications for location, correlation detection and machine learning and possible application to studies of repeating events in induced, volcanic and glacial seismicity. Our results place limits on the widely held assumption that waveform correlation is a useful measure of event separation. We suggest that the constraints on event separation need to be evaluated in the context of a population of related events, whose waveforms sample the signal space image of the source region. A better indicator of event separation is the length of the shortest path in signal space along the image.

58 GEOSCIENCES↗

LL18-Signal Analysis-NDD2Ad (Final Report)

Under favorable circumstances, seismic waveforms corresponding to an ensemble of events related by a common, spatially-distributed process collectively exhibit a regular, signal-space geometry. When events in the ensemble have a common, or nearly common, source mechanism, this geometry is a distorted image of the distribution of events in the source region. The signal space image can be visualized using a relatively simple waveform alignment and projection operation. Ensemble waveform correlation measurements can be inverted to estimate the distribution of the events in the source region, up to an arbitrary rotation, reflection, and scaling with residual distortion. We demonstrate these concepts with synthetic waveforms and with observations of long-wall mining induced seismicity for which substantial ground truth information is available. Our experience with these data has implications for location, correlation detection and machine learning, and possible application to studies of repeating events in induced, volcanic, and glacial seismicity. Our results place limits on the widely-held assumption that waveform correlation is a useful measure of event separation. We suggest that the constraints on event separation need to be evaluated in the context of a population of related events, whose waveforms sample the signal space image of the source region. A better indicator of event separation is the length of the shortest path in signal space along the image.

58 GEOSCIENCES↗

Femtosecond X-ray coherent diffraction of aligned amyloid fibrils on low background graphene

Here we present a new approach to diffraction imaging of amyloid fibrils, combining a free-standing graphene support and single nanofocused X-ray pulses of femtosecond duration from an X-ray free-electron laser. Due to the very low background scattering from the graphene support and mutual alignment of filaments, diffraction from tobacco mosaic virus (TMV) filaments and amyloid protofibrils is obtained to 2.7 Å and 2.4 Å resolution in single diffraction patterns, respectively. Some TMV diffraction patterns exhibit asymmetry that indicates the presence of a limited number of axial rotations in the XFEL focus. Signal-to-noise levels from individual diffraction patterns are enhanced using computational alignment and merging, giving patterns that are superior to those obtainable from synchrotron radiation sources. In conclusion, we anticipate that our approach will be a starting point for further investigations into unsolved structures of filaments and other weakly scattering objects.

47 OTHER INSTRUMENTATION↗

Joint high temperature observation of a small C6.5 solar flare with IRIS/EIS/AIA

We present the observation of a C6.5 class flare on 2014 February 3, obtained with the Interface Region Imaging Spectrograph (IRIS) and the EUV Imaging Spectrometer (EIS) on board HINODE. We follow the details of the impulsive phase with IRIS and the gradual decay phase with both IRIS and EIS. The IRIS Slit-Jaw Imager and Atmospheric Imaging Assembly (AIA) are used to precisely co-align the two sets of spectroscopic observations. Of particular interest is the Fe xxi 1354.08 Å spectral line, which is the highest temperature emission (∼10 MK) observed in the IRIS wavelength range. We show the evolution of the Fe xxi profiles during the impulsive phase of the flare at the same ribbon location with a 75 s temporal cadence. Totally blueshifted (∼82 km s{sup −1}) profiles are found at the very early phase of the flare and gradually decrease in about 6 minutes. This result is consistent with 1D model predictions during chromospheric evaporation in flares. The blueshifted components also exhibit large non-thermal broadening, which decreases simultaneously with the blueshifted velocity. After the evaporation first occurs, the Fe xxi intensity progressively moves from the footpoints to the top of the hot flare loops seen in the AIA 131 Å images, where the emission is observed to be at rest and thermal. Emission measure estimates from IRIS/EIS/AIA observations during the gradual phase show isothermal loop top structures cooling from about 13.5 to 12 MK with electron densities of the order of ∼5−6×10{sup 10} cm{sup −3}.

79 ASTRONOMY AND ASTROPHYSICS↗

Time-Resolved Molecular Frame Dynamics of Fixed-in-Space CS2 Molecules

Random orientation of molecules within a sample leads to blurred observationsof chemical reactions studied from the laboratory perspective. Methodsdeveloped for the dynamic imaging of molecular structures and processesstruggle with this, as measurements are optimally made in the molecular frame.Here we uselaser alignment to transiently fix CS2 molecules in space longenough to elucidate, in the molecular reference frame, details of ultrafast electronic vibrationaldynamics during a photochemical reaction. These three-dimensional photoelectron imaging results, combined with ongoing efforts in molecular alignment and orientation, presage a wide range of insights obtainable fromtime-resolved studies in the molecular frame.

74 ATOMIC AND MOLECULAR PHYSICS↗