Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “home performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Photoproduction of Multiply-Strange Hyperons at CLAS

The activities of the California State University, Dominguez Hills (CSUDH) Hadronic Structure Laboratory, undertaken with the support of the U.S. Department of Energy's Office of Science under grant DE-FG02-07ER41525, are described. This grant was originally awarded in 2007, and then renewed in 2009 and 2012, before it expired in 2015. The work was performed primarily at the home institution on the CSUDH campus in Carson, CA. A significant portion of the work was carried out at the Thomas Jefferson National Accelerator Facility (JLab) in Newport News, VA. The work covered in this award involves the study of the structure of the proton, which is done indirectly by looking at the Ξ particle. This is a particle with a spin and spatial structure similar to that of the proton, but with a different quark structure. Their properties are expected to be related due to SU(3) F symmetry. Additional work performed under this grant involved the construction of the High Threshold Cherenkov Counter, which was done by CSUDH undergraduate students in collaboration with JLab staff scientists.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fort Devens: Cold Climate Market-Rate Townhomes Targeting HERS Index of 40, Harvard, Massachusetts (Fact Sheet)

Achieving aggressive energy efficiency targets requires tight coordination and clear communication among owners, designers, builders, and subcontractors. For this townhome project, MassDevelopment, the quasi-governmental agency owner, selected Metric Development of Boston, teaming with the U.S. Department of Energy (DOE) Consortium for Advanced Residential Buildings (CARB) and Cambridge Seven Architects, to build very high performing market-rate homes. Fort Devens is part of a decommissioned army base in working-class Harvard, Massachusetts, approximately one hour northwest of Boston. The team proposed 12 net zero energy-ready townhomes, meaning that the application of renewable energy systems would result in annual net zero energy use in the homes. The homes were also designed to achieve a Home Energy Rating System (HERS) Index Score of 41 before adding renewables. For this project, CARB drew on its experience working with Rural Development Inc. on a series of affordable townhomes in northern Massachusetts. The team carefully planned the site to maximize solar access, daylighting, and efficient building forms. The basic strategy was to design a very efficient thermal enclosure while minimizing incremental cost increases compared with standard construction. Using BEopt modeling software, the team established the requirements of the enclosure and investigated multiple assembly options. They settled on double-wall construction with dense-pack cellulose fill. High performance vinyl windows (U-0.24, solar heat gain coefficient [SHGC]-0.22), a vented R-59 attic, and exceptional air sealing completed the package.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Systems Evaluation at the Cool Energy House

Steven Winter Associates, Inc. (SWA) monitored several advanced mechanical systems within a 2012 deep energy retrofitted home in the small Orlando suburb of Windermere, FL. This report provides performance results of one of the home's heat pump water heaters (HPWH) and the whole-house dehumidifier (WHD) over a six month period. In addition to assessing the energy performance of these systems,this study sought to quantify potential comfort improvements over traditional systems. This information is applicable to researchers, designers, plumbers, and HVAC contractors. Though builders and homeowners can find useful information within this report, the corresponding case studies are a likely better reference for this audience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Systems Evaluation at the Cool Energy House

Steven Winter Associates, Inc. (SWA) monitored several advanced mechanical systems within a 2012 deep energy retrofitted home in the small Orlando suburb of Windermere, FL. This report provides performance results of one of the home's heat pump water heaters (HPWH) and the whole-house dehumidifier (WHD) over a six month period. In addition to assessing the energy performance of these systems, this study sought to quantify potential comfort improvements over traditional systems. This information is applicable to researchers, designers, plumbers, and HVAC contractors. Though builders and homeowners can find useful information within this report, the corresponding case studies are a likely better reference for this audience.

air conditioning↗

A New Scanning Tunneling Microscope Reactor Used for High Pressure and High Temperature Catalysis Studies

We present the design and performance of a home-built high-pressure and high-temperature reactor equipped with a high-resolution scanning tunneling microscope (STM) for catalytic studies. In this design, the STM body, sample, and tip are placed in a small high pressure reactor ({approx}19 cm{sup 3}) located within an ultrahigh vacuum (UHV) chamber. A sealable port on the wall of the reactor separates the high pressure environment in the reactor from the vacuum environment of the STM chamber and permits sample transfer and tip change in UHV. A combination of a sample transfer arm, wobble stick, and sample load-lock system allows fast transfer of samples and tips between the preparation chamber, high pressure reactor, and ambient environment. This STM reactor can work as a batch or flowing reactor at a pressure range of 10{sup -13} to several bars and a temperature range of 300-700 K. Experiments performed on two samples both in vacuum and in high pressure conditions demonstrate the capability of in situ investigations of heterogeneous catalysis and surface chemistry at atomic resolution at a wide pressure range from UHV to a pressure higher than 1 atm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Final Report: TIP-337 Home Battery System for Cybersecure Energy Efficiency and Demand Response

Many challenges related to energy use and grid participation face the residential building sector and utilities that serve our homes today. To reduce energy consumption, increase grid service participation, and improve homeowner benefits, a solution is needed that can adapt itself to each home and homeowner/occupant, that can deliver both building and grid services with reliability and high availability, that can automate these operations to minimize cost and complexity of deployment, and that can provide both home data privacy and grid cybersecurity. We hypothesize that customer-oriented home automation can mutually satisfy home occupant/owner needs, reduce energy consumption, and deliver reliable grid services. This project seeks to develop innovative technology solutions that prove this hypothesis. The Home Battery System (HBS) is a technology package comprised of connected 'smart' appliances, rooftop solar photovoltaics, a home battery, and a coordinating smart controller. This system is envisioned, developed and demonstrated by the National Renewable Energy Laboratory (NREL), Bosch, ESCRYPT and Colorado State University (CSU). It is the result of three years of research by our diverse team. NREL developed the home automation controller, and performed simulation and laboratory evaluations of the HBS. Bosch developed and delivered most of the connected appliances used in the project, and provided technical and commercialization guidance. ESCRYPT led cybersecurity analysis and developed the cybersecurity layer. CSU provided leadership on preference elicitation methodologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Hydronic System Performance in Residential Applications

Even though new homes constructed with hydronic heat comprise only 3% of the market (US Census Bureau 2009), of the 115 million existing homes in the United States, almost 14 million of those homes (11%) are heated with steam or hot water systems according to 2009 US Census data. Therefore, improvements in hydronic system performance could result in significant energy savings in the US. When operating properly, the combination of a gas-fired condensing boiler with baseboard convectors and an indirect water heater is a viable option for high-efficiency residential space heating in cold climates. Based on previous research efforts, however, it is apparent that these types of systems are typically not designed and installed to achieve maximum efficiency. Furthermore, guidance on proper design and commissioning for heating contractors and energy consultants is hard to find and is not comprehensive. Through modeling and monitoring, CARB sought to determine the optimal combination(s) of components - pumps, high efficiency heat sources, plumbing configurations and controls - that result in the highest overall efficiency for a hydronic system when baseboard convectors are used as the heat emitter. The impact of variable-speed pumps on energy use and system performance was also investigated along with the effects of various control strategies and the introduction of thermal mass.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Hydronic System Performance in Residential Applications

Even though new homes constructed with hydronic heat comprise only 3% of the market (US Census Bureau 2009), of the 115 million existing homes in the United States, almost 14 million of those homes (11%) are heated with steam or hot water systems according to 2009 US Census data. Therefore, improvements in hydronic system performance could result in significant energy savings in the US.

AFUE↗

Furnace and Water Heater Venting Field Demonstration

A field demonstration was performed to evaluate the venting performance of the M&G DuraVent FasNSeal 80/90 venting system. The venting system uses a unique pipe within a pipe design to vent a condensing furnace and an natural-draft water heater, and can enable a condensing furnace to be installed in a home in which a condensing furnace could not otherwise be installed due to venting constraints. The field demonstration found that the FasNSeal 80/90 venting system successfully vented the orphaned water heater in each of the 16 demonstration homes and that the venting performance of the FasNSeal 80/90 venting system is generally comparable to the performance of venting systems initially installed in the 16 homes.

42 ENGINEERING↗

Verification and Validation of EnergyPlus Phase Change Material Model for Opaque Wall Assemblies

Phase change materials (PCMs) represent a technology that may reduce peak loads and HVAC energy consumption in buildings. A few building energy simulation programs have the capability to simulate PCMs, but their accuracy has not been completely tested. This study shows the procedure used to verify and validate the PCM model in EnergyPlus using a similar approach as dictated by ASHRAE Standard 140, which consists of analytical verification, comparative testing, and empirical validation. This process was valuable, as two bugs were identified and fixed in the PCM model, and version 7.1 of EnergyPlus will have a validated PCM model. Preliminary results using whole-building energy analysis show that careful analysis should be done when designing PCMs in homes, as their thermal performance depends on several variables such as PCM properties and location in the building envelope.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Polycrystalline VO{sub 2} film characterization by quantum capacitance measurement

Capacitance measurement is performed using a home-built bridge on quasi two-dimensional vanadium dioxide films grown on silicon-dioxide/p-doped silicon substrates. Correlated effects appearing in the quantum capacitance are obtained as a function of temperature at low frequencies. The thermodynamic density of states reveals the opening band gap in the insulating monoclinic phase.

36 MATERIALS SCIENCE↗

Weatherization Innovation Pilot Program: Program Overview and Philadelphia Project Highlight [Fact Sheet]

The Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE) recently launched the Weatherization Innovation Pilot Program (WIPP) to accelerate innovations in whole-house weatherization and advance DOE’s goal of increasing the energy efficiency and health and safety of homes of low-income families. Since 2010, WIPP has helped weatherization service providers as well as new and nontraditional partners leverage non-federal financial resources to supplement federal grants, saving taxpayer money. WIPP complements the Weatherization Assistance program (WAP), which operates nation-wide, in U.S. territories and in three Native American tribes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-Efficient Management of Mechanical Ventilation and Relative Humidity in Hot-Humid Climates

In hot and humid climates, it is challenging to energy-efficiently maintain indoor RH at acceptable levels while simultaneously providing required ventilation, particularly in high performance low cooling load homes. The fundamental problem with solely relying on fixed capacity central cooling systems to manage moisture during low sensible load periods is that they are oversized for cooler periods of the year despite being 'properly sized' for a very hot design cooling day. The primary goals of this project were to determine the impact of supplementing a central space conditioning system with 1) a supplemental dehumidifier and 2) a ductless mini-split on seasonal energy use and summer peak power use as well as the impact on thermal distribution and humidity control inside a completely furnished lab home that was continuously ventilated in accordance with ASHRAE 62.2-2013.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-Efficient Management of Mechanical Ventilation and Relative Humidity in Hot-Humid Climates

In hot and humid climates, it is challenging to energy-efficiently maintain indoor RH at acceptable levels while simultaneously providing required ventilation, particularly in high performance low cooling load homes. The fundamental problem with solely relying on fixed capacity central cooling systems to manage moisture during low sensible load periods is that they are oversized for cooler periods of the year despite being 'properly sized' for a very hot design cooling day. The primary goals of this project were to determine the impact of supplementing a central space conditioning system with 1) a supplemental dehumidifier and 2) a ductless mini-split on seasonal energy use and summer peak power use as well as the impact on thermal distribution and humidity control inside a completely furnished lab home that was continuously ventilated in accordance with ASHRAE 62.2-2013.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Construction Guide to Next-Generation High-Performance Walls in Climate Zones 3-5 - Part 1: 2x6 Walls

Part 1 of this Construction Guide to High-Performance Walls in Climate Zones 3-5 provides time-proven, practical, and cost-effective strategies for constructing durable, energy-efficient walls. It addresses walls constructed with 2x6 wood frame studs, wood structural panel (WSP) exterior sheathing, and a cladding system installed over WSP sheathing in low-rise residential buildings up to three stories high.

2x6 wood frame studs↗

Construction Guide to Next-Generation High-Performance Walls in Climate Zones 3-5 - Part 2: 2x4 Walls

Part 2 of this Construction Guide to High-Performance Walls in Climate Zones 3-5 provides straightforward and cost-effective strategies to construct durable, energy-efficient walls. It addresses walls constructed with 2x4 wood frame studs, wood structural panel (WSP) sheathing as wall bracing and added backing for foam sheathing, a layer of rigid foam sheathing insulation up to 1.5 inches thick over the WSP, and a cladding system installed over the foam sheathing in low-rise residential buildings up to three stories high. Walls with 2x6 framing are addressed in Part 1 of the Guide.

2x4 wood frame studs↗

Construction Guide to Next-Generation High-Performance Walls in Climate Zones 3-5 - Part 1: 2x6 Walls

Part 1 of this Construction Guide to High-Performance Walls in Climate Zones 3-5 provides time-proven, practical, and cost-effective strategies for constructing durable, energy-efficient walls. It addresses walls constructed with 2x6 wood frame studs, wood structural panel (WSP) exterior sheathing, and a cladding system installed over WSP sheathing in low-rise residential buildings up to three stories high.

2x6 wood frame studs↗

Construction Guide to Next-Generation High-Performance Walls in Climate Zones 3-5 - Part 2: 2x4 Walls

Part 2 of this Construction Guide to High-Performance Walls in Climate Zones 3-5 provides straightforward and cost-effective strategies to construct durable, energy-efficient walls. It addresses walls constructed with 2x4 wood frame studs, wood structural panel (WSP) sheathing as wall bracing and added backing for foam sheathing, a layer of rigid foam sheathing insulation up to 1.5 inches thick over the WSP, and a cladding system installed over the foam sheathing in low-rise residential buildings up to three stories high. Walls with 2x6 framing are addressed in Part 1 of the Guide.

2x4 wood frame studs↗