Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating and cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Smart Houses

GWS takes plans for a new home and subjects them to intensive computerized analysis that does 10,000 calculations relative to expected heat loss and heat gain, then provides specifications designed specifically for each structure as to heating, cooling, ventilation and insulation. As construction progresses, GWS inspects the work of the electrical, plumbing and insulation contractors and installs its own Smart House Radiant Barrier. On completion of the home, GWS technicians use a machine that creates a vacuum in the house and enables computer calculation of the air exchanged, a measure of energy efficiency. Key factor is the radiant barrier, borrowed from the Apollo program. This is an adaptation of a highly effective aluminized heat shield as a radiation barrier holding in or keeping out heat, cold air and water vapor.

Source record↗

Doppler-Lidar Evaluation of HRRR-Model Skill at Simulating Summertime Wind Regimes in the Columbia River Basin during WFIP2

Complex-terrain locations often have repeatable near-surface wind patterns, such as synoptic gap flows and local thermally forced flows. An example is the Columbia River Valley in east-central Oregon-Washington, a significant wind-energy-generation region and the site of the Second Wind-Forecast Improvement Project (WFIP2). Data from three Doppler lidars deployed during WFIP2 define and characterize summertime wind regimes and their large-scale contexts, and provide insight into NWP model errors by examining differences in the ability of a model [NOAA’s High-Resolution Rapid-Refresh (HRRR-version1)] to forecast wind-speed profiles for different regimes. Seven regimes were identified based on daily time series of the lidar-measured rotor-layer winds, which then suggested two broad categories. First, in three regimes the primary dynamic forcing was the large-scale pressure gradient. Second, in two regimes the dominant forcing was the diurnal heating-cooling cycle (regional sea-breeze-type dynamics), including the marine intrusion previously described, which generates strong nocturnal winds over the region. The other two included a hybrid regime and a non-conforming regime. For the large-scale pressure-gradient regimes, HRRR had wind-speed biases of ~1 m s -1 and RMSEs of 2-3 m s -1 . Errors were much larger for the thermally forced regimes, owing to the premature demise of the strong nocturnal flow in HRRR. Thus, the more dominant the role of surface heating in generating the flow, the larger the errors. Major errors could result from surface heating of the atmosphere, boundary-layer responses to that heating, and associated terrain interactions. Finally, measurement/modeling research programs should be aimed at determining which modeled processes produce the largest errors, so those processes can be improved and errors reduced.

17 WIND ENERGY↗

In-situ Characterizations of Microstructural Degradation of Perovskite Solar Cells

Rapid progress has been achieved in perovskite solar cells (PSCs), and their efficiencies have improved from 3.8 % to 24.2 % in less than a decade. With low-cost processing, PSCs have shown exciting photovoltaic (PV) properties, such as effective optical absorption, a long carrier lifetime, and unique defect tolerance. While recent studies demonstrated improved stability up to 100 days, PSC technology is still challenged to meet the stringent industry requirements for commercialization. Despite considerable efforts, the underlying physical mechanisms for the inferior stability of PSCs are not well understood. One reason for this divergence is that many established measurement techniques (e.g., quantum efficiency, photoluminescence) probe the properties on length scales far greater than that of electronic and/or structural inhomogeneity (i.e., < 1 μm near grain boundaries) and therefore characterize convoluted and/or averaged properties. Ion/electron beam-based techniques have been extensively used to access the microstructures of PSCs, enabling atomic/nanoscale structural, chemical, optical, and electrical characterizations. For example, focused ion beam (FIB) milling produces an atomically smooth surface that minimizes the artifacts attributed to the surface roughness. FIB techniques can also create a well-defined cross-section of PSCs without mechanical damage in a physical cleaving sample preparation. While powerful, there are some concerns about possible beam damage of inorganic-organic perovskites via chemical-bond breakage and local heating. This project aims to comprehensively understand how the microstructural/interfacial properties of PSCs (e.g., Methylammonium Lead Iodide [MAPbI 3 ]) are modified under the irradiating ion beams. Specifically, we investigate the sub-surface properties of PSCs before and after Ar-ion beam injections. Kelvin probe force microscopy (KPFM) measures the contact potential differences (CPDs). Photoluminescence (PL) microscopy in conjunction with Finite-Difference Time-Domain (FDTD) simulations infers the formation of a “dead layer” (< 15 nm) on the subsurface of MAPbI 3 during Ar+ milling processes while preserving the initial bulk properties. The x-ray photoemission spectroscopy (XPS) confirms this modified surface is a lead-rich and iodine-deficient surface. We initiate customizing in-situ measurement setup while measuring the local optical and electrical properties of PSC under thermal (cooling, heating) and light stressors. Our results provide in-depth knowledge of the ion-beam impact on metal-halide perovskites and how this modified sub-surface impacts their properties under accelerated stressors of light and heat. Intensive Monte Carlo simulations of an electron beam interacting with PSCs provide the beam energy distribution in PSCs, proposing possible measurement conditions of using e-beam with minimizing beam damage. Our in-situ measurement platform can accommodate the diverse architecture of PSC devices for studying deterioration mechanisms under mixed environmental stressors.

14 SOLAR ENERGY↗

Simulations of radiatively cooled magnetic reconnection driven by pulsed power

Magnetic reconnection is an important process in astrophysical environments, as it reconfigures magnetic field topology and converts magnetic energy into thermal and kinetic energy. In extreme astrophysical systems, such as black hole coronae and pulsar magnetospheres, radiative cooling modifies the energy partition by radiating away internal energy, which can lead to the radiative collapse of the reconnection layer. In this paper, we perform two- and three-dimensional simulations to model the MARZ (Magnetic Reconnection on Z) experiments, which are designed to access cooling rates in the laboratory necessary to investigate reconnection in a previously unexplored radiatively cooled regime. These simulations are performed in GORGON, an Eulerian two-temperature resistive magnetohydrodynamic code, which models the experimental geometry comprising two exploding wire arrays driven by 20 MA of current on the Z machine (Sandia National Laboratories). Radiative losses are implemented using non-local thermodynamic equilibrium tables computed using the atomic code Spk, and we probe the effects of radiation transport by implementing both a local radiation loss model and P 1/3 multi-group radiation transport. The load produces highly collisional, super-Alfvénic (Alfvén Mach number M A ≈ 1.5), supersonic (Sonic Mach number M S ≈ 4–5) strongly driven plasma flows which generate an elongated reconnection layer (Aspect Ratio L/δ≈100 , Lundquist number S L ≈ 400). The reconnection layer undergoes radiative collapse when the radiative losses exceed the rates of ohmic and compressional heating (cooling rate/hydrodynamic transit rate = τ$^{–1}_{cool}$/τ$^{–1}_{H}$ ≈100); this generates a cold strongly compressed current sheet, leading to an accelerated reconnection rate, consistent with theoretical predictions. Lastly, the current sheet is also unstable to the plasmoid instability, but the magnetic islands are extinguished by strong radiative cooling before ejection from the layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Water cycles in closed ecological systems: effects of atmospheric pressure

In bioregenerative life support systems that use plants to generate food and oxygen, the largest mass flux between the plants and their surrounding environment will be water. This water cycle is a consequence of the continuous change of state (evaporation-condensation) from liquid to gas through the process of transpiration and the need to transfer heat (cool) and dehumidify the plant growth chamber. Evapotranspiration rates for full plant canopies can range from ~1 to 10 L m-2 d-1 (~1 to 10 mm m-2 d-1), with the rates depending primarily on the vapor pressure deficit (VPD) between the leaves and the air inside the plant growth chamber. VPD in turn is dependent on the air temperature, leaf temperature, and current value of relative humidity (RH). Concepts for developing closed plant growth systems, such as greenhouses for Mars, have been discussed for many years and the feasibility of such systems will depend on the overall system costs and reliability. One approach for reducing system costs would be to reduce the operating pressure within the greenhouse to reduce structural mass and gas leakage. But managing plant growth environments at low pressures (e.g., controlling humidity and heat exchange) may be difficult, and the effects of low-pressure environments on plant growth and system water cycling need further study. We present experimental evidence to show that water saturation pressures in air under isothermal conditions are only slightly affected by total pressure, but the overall water flux from evaporating surfaces can increase as pressure decreases. Mathematical models describing these observations are presented, along with discussion of the importance for considering "water cycles" in closed bioregenerative life support systems.

NASA Center KSC↗

Integrated Dynamic Facade Control with an Agent-based Architecture for Commercial Buildings

Dynamic façades have significant technical potential to minimize heating, cooling, and lighting energy use and peak electric demand in the perimeter zone of commercial buildings, but the performance of these systems is reliant on being able to balance complex trade-offs between solar control, daylight admission, comfort, and view over the life of the installation. As the context for controllable energy-efficiency technologies grows more complex with the increased use of intermittent renewable energy resources on the grid, it has become increasingly important to look ahead towards more advanced approaches to integrated systems control in order to achieve optimum life-cycle performance at a lower cost. This study examines the feasibility of a model predictive control system for low-cost autonomous dynamic façades. A system architecture designed around lightweight, simple agents is proposed. The architecture accommodates whole building and grid level demands through its modular, hierarchical approach. Automatically-generated models for computing window heat gains, daylight illuminance, and discomfort glare are described. The open source Modelica and JModelica software tools were used to determine the optimum state of control given inputs of window heat gains and lighting loads for a 24-hour optimization horizon. Penalty functions for glare and view/ daylight quality were implemented as constraints. The control system was tested on a low-power controller (1.4 GHz single core with 2 GB of RAM) to evaluate feasibility. The target platform is a low-cost ($35/unit) embedded controller with 1.2 GHz dual-core cpu and 1 GB of RAM. Configuration and commissioning of the curtainwall unit was designed to be largely plug and play with minimal inputs required by the manufacturer through a web-based user interface. An example application was used to demonstrate optimal control of a three-zone electrochromic window for a south-facing zone. The overall approach was deemed to be promising. Further engineering is required to enable scalable, turnkey solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Response Testing in an Electrically Heated Reactor Test Facility

Non-nuclear testing can be a valuable tool in development of a space nuclear power or propulsion system. In a non-nuclear test bed, electric heaters are used to simulate the heat from nuclear fuel. Standard testing allows one to fully assess thermal, heat transfer, and stress related attributes of a given system, but fails to demonstrate the dynamic response that would be present in an integrated, fueled reactor system. The integration of thermal hydraulic hardware tests with simulated neutronic response provides a bridge between electrically heated testing and full nuclear testing. By implementing a neutronic response model to simulate the dynamic response that would be expected in a fueled reactor system, one can better understand system integration issues, characterize integrated system response times and response characteristics, and assess potential design improvements at a relatively small fiscal investment. Initial system dynamic response testing was demonstrated on the integrated SAFE-100a heat pipe cooled, electrically heated reactor and heat exchanger hardware, utilizing a one-group solution to the point kinetics equations to simulate the expected neutronic response of the system (Bragg-Sitton, 2005). The current paper applies the same testing methodology to a direct drive gas cooled reactor system, demonstrating the applicability of the testing methodology to any reactor type and demonstrating the variation in system response characteristics in different reactor concepts. In each testing application, core power transients were controlled by a point kinetics model with reactivity feedback based on core average temperature; the neutron generation time and the temperature feedback coefficient are provided as model inputs. Although both system designs utilize a fast spectrum reactor, the method of cooling the reactor differs significantly, leading to a variable system response that can be demonstrated and assessed in a non-nuclear test facility.

Bragg-Sitton, Shannon M.↗

Retrofittable Thermal Switches for Dynamic Building Envelopes Integrated with Thermal Energy Storage: Preprint

Buildings in the United States consume about 40 quadrillion BTU of primary energy annually, which accounts for the nation's 40% of total energy use, 75% of all electricity use, and 35% of the net carbon emissions. Deploying thermal energy storage in the form of phase change material (PCM) in building envelopes is an effective method to reduce space heating/cooling loads, provide load shedding, and shift demand to periods of lower energy cost. However, the full potential of PCM-integrated envelopes can only be realized if the PCM undergoes complete phase change using free ambient heating/cooling, and the stored energy is effectively transferred between the exterior and the interior environments. Conventional thermal insulation (with a fixed thermal resistance) limits PCM utilization, particularly with the increasing emphasis on higher R-value in building envelopes, which negatively affects the energy-saving potential of a PCM-integrated envelope. In contrast, dynamic building envelopes integrated with PCMs provide the option of varying the thermal resistance based on the indoor and outdoor conditions, thereby enhancing utilization of free ambient cooling and heating to charge/discharge the PCM thermal storage, reducing the buildings' heating and cooling load, and shifting the peak energy demand. In this study, we demonstrate innovative retrofittable thermal switches in the form of the insertable plugs inside an insulation to provide variable thermal resistance depending on the operating temperature and direction of temperature gradient, thus allowing preferential directional heat flow. Notably, they are passive in nature, requiring no external power, and work solely based on the ambient temperature.

buildings↗

Carbon dioxide catastrophes: Past and future menace

Carbon dioxide is important in its role as coupler of the terrestrial biosphere to inorganic chemical processes and as the principal greenhouse gas controlling Earth's surface temperature. The hypothesis that atmospheric CO2 levels have diminished with time, with the resulting cooling effect offsetting an increase in the solar constant, seems firmly established, and it is shown that feedback mechanisms exist which can maintain the terrestrial surface in a relatively narrow temperature range over geological time. Of the factors involved in such CO2 variation, the oceanic reservoir appears the most important. Surface waters are probably in approximate equilibrium with regard to CO2 exchange with the ambient atmosphere in most regions, but data from deep-ocean water sampling indicates that such waters are somewhat undersaturated in the sense that they would tend to absorb CO2 from the atmosphere if brought to the surface without change in composition or temperature. If major impacts into the ocean can result in loss of a substantial portion of the atmospheric CO2 reservoir, then any such future event could imperil the continuation of most higher forms of life on Earth. The most likely candidate for an inverse Nyos global event in previous Earth history is the Cretaceous-Tertiary terminal extinction event. The Cretaceous was characterized by warm, equable temperatures presumably indicative of relatively high CO2 levels and an intense greenhouse heating. Cooling of the oceans in absence of massive transfer of CO2 to the oceanic reservoir in itself would promote a condition of CO2 undersaturation in abyssal waters, and this is made even more extreme by the pattern of ocean water circulation. It is possible to envision a situation in which deep ocean waters were at least occasionally profoundly undersaturated with regard to CO2. Turnover of a major fraction of such an ocean would then remove, on a very short time scale, as much as 90 percent of the atmospheric CO2 inventory.

Baur, Mario E.↗

Community Geothermal: Soil Conductivity, Borehole Design, Energy Models, and Load Data for a Residential System Development - Hinesburg, VT

This dataset contains materials from the Coalition for Community-Supported Affordable Geothermal Energy Systems (C2SAGES) project, which evaluated the techno-economic feasibility of a community geothermal system for a residential development in Hinesburg, VT. The dataset includes detailed soil conductivity test reports, energy models, borehole design reports, hourly energy loads for heating, cooling, and hot water, and design layouts. EnergyPlus was used to model building energy loads, and Modelica software was applied for geothermal loop sizing based on these loads and soil conductivity results. Python scripts for network design further refined the models. Key files include PDF reports on borehole design (with projections for 1-year, 15-year, and 30-year systems), soil conductivity test results, EnergyPlus modeling outputs, and 2D/3D design drawings in PDF, DWG, and DXF formats. Python notebooks for network design and OnePipe model files are also provided, with Modelica required for viewing certain files. Outputs and modeling data are in various formats including CSV, JPG, HTML, and IDF, with units and data clearly labeled to support understanding of system design and performance for the proposed geothermal solution.

15 GEOTHERMAL ENERGY↗

Development of Integrated Mechanical Pods

This presentation highlights early wins, updated progress, and upcoming developments on ‘national-scale shared development platform’ for rapid prototyping, testing and validation of various integrated Mechanical Pod solutions and form factors. Such pod solutions consist of a set of all-electric heat pump mechanical equipment that have integrated functionalities through built-in controls, with heating, cooling, hot water, ventilation (including energy recovery), electrical management, and battery storage within a single package. The presentation draws inspiration from the success of bathroom pods in the US modular construction industry, UK’s efforts with unitizing mechanical systems as ‘utility cupboards’, and VEIC’s early wins in design-build of all-electric Mechanical Pod solutions in Vermont. The presentation includes researchers and partners involved with NREL in Design for Manufacturing and Assembly (DfMA), Virtual Design and Construction (VDC), and digital twin based process optimization modeling of integrated Mechanical Pod solutions. The presentation aims to highlight early wins from such a platform and how various physical and virtual tools are currently being employed as part of NREL’s ongoing multi-year project funded by US DOE. Streamlined procurement, coordination, installation, and O&M of Mechanical Pods such that the majority of work is delegated to the off-site modular factory implies monetary savings. Such a seemingly basic shift in location of the construction process leads to great reduction in complexity, first cost, lead time, and waste, and greater opportunities for innovative compartmentalization and integration of mechanical systems appropriately sized for each apartment or hotel guest room. However, past studies on unitized combination systems show that high installation costs, maintenance issues, challenges with system integration, limitations in existing electrical infrastructure, and lack of architecturally appealing solutions are key barriers. NREL and partners aim to address key barriers through DfMA approach, rapid prototyping and testing, and digital twin process optimization modeling. The presentation is also a call for interested entities to partner with NREL as part of the national-scale development platform, help drive both product and process innovation, and encourage open source sharing of learnings. Learning objectives include (1) learn about the vision of national-scale shared development platform for process-product innovation on integrated mechanical pod solutions and how to get involved, (2) gain an understanding of the components of an all-electric, high performance home, design characteristics and equipment included in an all-electric mechanical pod, integration of mechanical systems within a modular factories’ assembly line, and the system’s commissioning, operation and maintenance. The pre-planning and coordination with the factory and sub-contractors are also highlighted, (3) gain an understanding of using process modeling tools to quantify resource-constrained performance of operations (such as integration of energy efficiency strategies) to manufacture modules of varying design, (4) gain insights on virtual design, rapid prototyping, and emulated testing of various form factors across different climatic conditions. The need for such preliminary testing with open source sharing of learnings will also be highlighted.

30 DIRECT ENERGY CONVERSION↗

Field validation of data-driven BSDF and peak extraction models for light-scattering fabric shades

Shading and daylighting systems affect cooling, heating, and lighting energy use by modulating solar radiation through the building façade. Characterizing shading systems holistically and accurately helps designers and engineers evaluate shading systems to achieve energy and non-energy performance goals. These complex fenestration systems can be modeled using Bidirectional Scattering Distribution Functions (BSDF), which map incident radiation to hemispherical distributions of outgoing radiation. Data-driven, tabulated BSDFs are derived from interpolated goniophotometer measured data, then sampled during the raytracing calculation. A peak extraction (PE) algorithm was developed to circumvent limits in BSDF angular resolution, where the specular peak is extracted during simulation by evaluating the BSDF in the through direction and surrounding region. The objective of this study was to validate this measurement and modeling workflow using field monitored data from a full scale testbed with eleven installed fabrics of different weaves, openness factors, and colors and assess the accuracy of the workflow under different adaptation and contrast conditions. Test conditions were limited to clear sky conditions with the sun in the field of view. Results showed that, for tensor tree datasets, vertical illuminance, solar luminance (2.5° apex), and daylight glare probability (DGP) were predicted to within a mean bias error (MBE) error of -456 lx (-12.3%), -3.46e5 (-38.4%), and -0.042 (-7.8%) when full PE occurred. With a binary classification of glare/ no glare, DGP was predicted accurately with a true positive rate of 0.98 and true negative rate of 1.0 using tensor tree data and less accurately with Klems BSDF data, particularly for cases of no glare. The workflow may be of insufficient accuracy to distinguish borderline performance between fabrics using the four-point glare scale, particularly under low adaptation, high contrast daylit conditions. Errors were due to reductions in peak shape and intensity across the BSDF interpolation and data reduction workflow. Future work is needed to better preserve measurement fidelity during interpolation and sampling, which in turn will improve PE performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conditional distribution estimation of building characteristics with diffusion models for urban energy modeling

Understanding current energy consumption behavior in communities is critical for informing future energy use decisions and enabling efficient energy management. Urban energy models, which are used to simulate these energy use patterns, require large datasets with detailed building characteristics for accurate outcomes. However, such detailed characteristics at the individual building level are often unknown and costly to acquire, or unavailable. Through this work, we propose using a generative modeling approach to generate realistic building attributes to fill in the data gaps and finally provide complete characteristics as inputs to energy models. Our model learns complex, building-level patterns from training on a large-scale residential building stock model containing 2.2 million buildings. We employ a tabular diffusion-based framework that is designed to handle heterogeneous (discrete and continuous) features in tabular building data, such as occupancy, floor area, heating, cooling, and other equipment details. We develop a capability for conditional diffusion, enabling the imputation of missing building characteristics conditioned on known attributes. We conduct a comprehensive validation of our conditional diffusion model, firstly by comparing the generated conditional distributions against the underlying data distribution, and secondly, by performing a case study for a Baltimore residential region, showing the practical utility of our approach. Our work is one of the first to demonstrate the potential of generative modeling to accelerate building energy modeling workflows.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strength and ductility of additively manufactured 316L stainless steel: Impact of neutron irradiation and data variability

Here, this article presents the mechanical properties of additively manufactured (AM) 316L stainless steel processed via the laser powder bed fusion (LPBF) method, focusing on the effects of neutron irradiation on mechanical properties and the variability in strength and ductility data. The rapid melting-solidification process and multiple heating-cooling cycles inherent in LPBF typically result in a fine, metastable microstructure with significant local variability. AM 316L builds of varying thicknesses were fabricated, and SS-J3 miniature tensile specimens were machined from six different locations. These specimens were irradiated with fast neutrons to doses of 2 and 10 dpa at target temperatures of 300 °C and 600 °C. Post-irradiation tensile tests were conducted at room temperature, 300 °C, and 600 °C. Compared to conventional 316L stainless steel, AM 316L exhibited higher initial strength but lower ductility. Irradiation at 300 °C caused significant hardening and prompt necking at yield, with limited uniform ductility, although embrittlement was not observed up to 10 dpa. While neutron irradiation, particularly at 600 °C, increased the variability in strength and ductility data, no clear dependence of mechanical properties on build thickness or sampling location was found—contrary to the conventional perception that AM materials may exhibit high property variability. Furthermore, we observed that the variability in property data for LPBF-processed 316L was relatively low compared to that of wrought 316L stainless steel. This reduced variability in AM 316L steel may be attributed to its highly metastable, stress-containing microstructure, which is discussed in the context of general tensile property variations.

Additively manufactured 316L stainless steel↗

Energy savings and life cycle cost analysis of advanced double skin facade system applied to old apartments in South Korea

South Korea is one of the most densely populated countries in the world, and the population density in urban areas is much higher among others. Apartments are the most common form of residential buildings due to their high population density. More than 60% of domestic residential buildings are apartments, with more than 10 million households. The high population density is a problem that has long plagued South Korea because more than 45% of apartments are old apartments that are more than 20 years old. Old apartment buildings have low thermal performance that results in lots of energy consumption. Balconies, which worked as a thermal buffer, are also being removed by residents to expand indoor space. According to the green remodeling project supported by the Korean government, the typical retrofitting method is replacing external windows with the high-efficiency window in old apartments in South Korea. Here, this paper proposes a retrofitting method using an extended double-skin façade (DSF) system that replaces exterior windows and acts as a thermal buffer. The simulation model is developed with the EnergyPlus simulation program to conduct energy performance analyses. The simulation model has been calibrated using actual experimental data collected between October 1, 2019, and January 15, 2020. Results show that the cooling, heating, and lighting energy can be reduced up to 44.1% by fully utilizing electric energy generated by solar PV panels integrated with the DSF system. The payback period is about 15 years based on the energy price provided by the utility company. Although the payback period is long, it has great potential of energy savings and CO 2 emission reductions. The DSF system should be considered as a way of renovation, considering other factors such as increased real estate values and energy cost increases in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Near-field passive sensor for the monitoring of high-temperature oxidative corrosion of metals

This study reports on the development and testing of a passive wireless device designed to track temperature and corrosion behavior in SS304H stainless steel under elevated temperatures. The ANSYS HFSS software was utilized to model and optimize the design of an inductor-capacitor (LC) resonator passive wireless sensors fabricated using platinum designs printed onto an aluminum oxide support operating at frequencies between (50–190 MHz). The optimal LC wireless sensor designs were then fabricated using screen-printing and sintering methods. Here, the sensors were tested by placing the sensor onto polished SS304H flat substrates and heated to 900–1050 °C in air. Wireless acquisition of sensor data during heating, cooling, and isothermal stages was achieved through a Pt loop antenna connected to an RF signal generator and a network analyzer.

20 FOSSIL-FUELED POWER PLANTS↗

Impact of nano-scale cavities on hydrogen storage and retention in yttrium hydride

Here, in situ synchrotron high-energy x-ray diffraction experiments and detailed transmission electron microscopy (TEM) characterization were conducted on as-fabricated and neutron-irradiated yttrium hydrides. The high-resolution synchrotron x-ray diffraction revealed minor α yttrium and major δ yttrium hydride phases in all specimens. Specimens were subject to heat treatments (heating-cooling cycles), and the intensity of α yttrium partially and completely disappeared in as-fabricated and neutron-irradiated specimens, respectively. The disappearance of α yttrium was unforeseen because hydrogen was expected to leave δ phase, causing an increase in α yttrium diffraction peak intensity. This observation indicated a surplus of hydrogen in the specimens where it was odd for hydride-forming early transition metal elements. The subsequent through-focus TEM characterization discovered nanometric cavities in both as-fabricated and neutron-irradiated yttrium hydride specimens for the first time. Two types of cavities were identified as fabrication-caused and irradiation-induced. The fabrication-caused cavities were associated with regions having linear deformation features, interfaces, and inclusions. The irradiation-induced cavities were observed as being formed isolated in the yttrium hydride phase. The presence of such nanometric cavities was considered as potential hydrogen storage pockets where the overall hydrogen storing capacity of yttrium hydride would be enhanced.

36 MATERIALS SCIENCE↗

Development of an in situ ion irradiation scanning electron microscope

An in situ ion irradiation scanning electron microscope (I 3 SEM) has been developed, installed, and integrated into the Ion Beam Laboratory at Sandia National Laboratories. The I 3 SEM facility combines a field emission, variable pressure, scanning electron microscope, a 6 MV tandem accelerator, high flux low energy ion source, an 808 nm-wavelength laser, and multiple stages to control the thermal and mechanical state of the sample observed. The facility advances real-time understanding of materials evolution under combined environments at the mesoscale. As highlighted in multiple examples, this unique combination of tools is optimized for studying mesoscale material response in overlapping extreme environments, allowing for simultaneous ion irradiation, implantation, laser bombardment, conductive heating, cooling, and mechanical deformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗