Off-Normal Scenarios Using Resistively Heated Targets

This report describes the continuation of thermal experiments using the resistively heated target assembly within the helium flow loop at LANSCE that is described in the report, Resistively Heated Target Tests Using Helium Flow Loop, by Alexander Wass et al. In order to replicate off-normal operating scenarios of the helium cooled Mo-100 plant design disks during beam heating, an array of resistive heaters were placed within the helium flow loop, cooled via helium, and modified slightly. The resistively heated test piece is comprised of seven ceramic electric heaters with embedded thermocouples allowing temperature measurements of each heater. A total of three scenarios were performed. One unmodified scenario, and two off-normal scenarios were conducted to simulate a blocked cooling channel due to debris within the flow loop and a broken disk during in-beam heating at the Mo-99 production facility. A removable insert was placed within a cooling channel to block the flow of helium, and a resistive heater was removed to simulate a broken disk that had been evacuated from the target assembly. The inlet and outlet cooling pipe employs rectangular tubing to make a 90° bend at a radius consistent with and practical for the actual plant design.

36 MATERIALS SCIENCE↗

A groundwater flow and transport model of long-term radionuclide migration in central Frenchman flat, Nevada test site

A set of groundwater flow and transport models were created for the Central Testing Area of Frenchman Flat at the former Nevada Test Site to investigate the long-term consequences of a radionuclide migration experiment that was done between 1975 and 1990. In this experiment, radionuclide migration was induced from a small nuclear test conducted below the water table by pumping a well 91 m away. After radionuclides arrived at the pumping well, the contaminated effluent was discharged to an unlined ditch leading to a playa where it was expected to evaporate. However, recent data from a well near the ditch and results from detailed models of the experiment by LLNL personnel have convincingly demonstrated that radionuclides from the ditch eventually reached the water table some 220 m below land surface. The models presented in this paper combine aspects of these detailed models with concepts of basin-scale flow to estimate the likely extent of contamination resulting from this experiment over the next 1,000 years. The models demonstrate that because regulatory limits for radionuclide concentrations are exceeded only by tritium and the half-life of tritium is relatively short (12.3 years), the maximum extent of contaminated groundwater has or will soon be reached, after which time the contaminated plume will begin to shrink because of radioactive decay. The models also show that past and future groundwater pumping from water supply wells within Frenchman Flat basin will have negligible effects on the extent of the plume.

54 ENVIRONMENTAL SCIENCES↗

Predictive LES Modeling and Validation of High-Pressure Turbulent Flames and Flashback in Hydrogen-enriched Gas Turbines

The overall objective of this project is to make advances in large-eddy simulation modeling of swirl-flame flashback at elevated pressure, where the reactants can be premixed or stratified, and composed of methane enriched with hydrogen. The modeling effort was conducted with a companion experimental validation effort that focused on high-speed measurements of flashback in a model swirl-flame combustor. The modeling effort focused on the development of manifold-based combustion model for flashback simulations. The main complexity in this configuration comes from the flames’ propagation through a stratified fuel-air mixture along with heat loss near the walls. For this purpose, a non-adiabatic flamelet model was developed and tested using canonical flow configurations. Further, extensive validation in premixed configurations is used to establish the model’s accuracy in capturing heat loss and flame propagation. Finally, the model was tested using the UT flame flashback experiment, and was shown to accurately capture the flame flashback process. The end products from this work are a) a full validated flameout-based approach for modeling flame flashback; b) a complete implementation of the model in the open source OpenFOAM framework, which has been made available to both industry and academia; c) an extensive suite of validation studies performed using the OpenFOAM solver. In addition, new techniques for flame modeling, subfilter modeling of scalars, and simulation of low Mach number flows were developed and tested. In the experimental validation effort, flashback was studied in a premixed and stratified swirl flame by using high-speed imaging diagnostics. Fuels tested included CH 4 enriched with H 2 , with H 2 enrichment up to 84% by volume. These flashback experiments are conducted at pressures ranging from 1 to 5 atm. A swirler-based fuel-injection system was used to create the fuel-air stratification in the radial direction. For the high-pressure measurements, an optically accessible elevated pressure chamber was used. The spatial distribution of the equivalence ratio under non-reacting conditions was characterized using planar laser-induced fluorescence with acetone as the fuel tracer. It was observed that fuel-air pockets were distributed across the mixing tube width, although in an average sense, the fuel-air mixture was radially stratified. The global behavior of upstream flame propagation was investigated for different levels of hydrogen-enrichment. For stratified hydrogen-rich flashback, the propagation path of the flame changed from the inner wall to outer wall, which was induced by the faster chemistry of stoichiometric mixtures that are frequently present near the outer wall. This behavior of hydrogen-rich flashback persists even at elevated pressures up to 5 atm, although the propagation of the flame occurs as a wide flame tongue as opposed to the acute-tipped flame structures present in the atmospheric cases. The end product of the experimental effort is greatly improved knowledge of flashback physics and a unique database that can be used for model validation.

08 HYDROGEN↗

Noncontact Flow Rate Using Laser Ultrasonics

Several types of advanced nuclear reactors are cooled with high-temperature liquid metal or molten salt flows. There is a critical need to measure flow velocity in flow channels for test purposes, and eventually in operational reactors. In conventional ultrasonic flow sensors, ultrasonic waves traveling in both the upstream and downstream directions are generated and detected by transducers that must contact the flow channels. A shift in the frequency or transit time between the two ultrasonic waves is measured to determine flow velocity. We describe here an initial effort to apply that sensing concept when the contact transducers are replaced by laser-based generation and detection instrumentation. This noncontact sensing avoids many practical problems associated with contact transducers when implemented on flow channels at high temperature. Laser-based flow monitoring can also be applied to hot-process piping in the geothermal energy, chemical-processing and petroleum-refining industries. Our effort has included theoretical simulation of noncontact laser-based flow monitoring, indicating capability of measuring flow velocities relevant to reactor cooling. It also included a room-temperature experimental demonstration using water as the flow liquid, and indicating capability of measuring flow velocity at a responsivity roughly consistent with simulation predictions. Plans were made for an experimental demonstration at Oregon State University using liquid metal at 110 degrees C.

02 PETROLEUM↗

Comparison of steady and transient flow boiling critical heat flux for FeCrAl accident tolerant fuel cladding alloy, Zircaloy, and Inconel

Steady and transient (with a heating rate of 685?/s) internal-flow CHF (Critical Heat Flux) experiments were conducted under atmospheric pressure at a fixed inlet temperature (40? or 60?) and mass flow (300kg/m 2 s) on Fe-13Cr-6Al alloy, Inconel 600 and Zircaloy-4 tube samples. Multiple experiments were repeated on the same specimen to investigate the effect of surface characteristic changes (i.e., roughness, wettability, and oxide scale morphology) on the occurrence of CHF. Despite notable changes of wettability, roughness, and oxide layer characteristics on samples that had already been subjected to CHF, measured flow CHF remained unchanged throughout repeated experiments for tested materials. This demonstrates that the surface effects on flow CHF are limited in the test conditions. In the steady-state flow boiling condition, Fe-13Cr-6Al alloy demonstrated a 22% and 14% increase in CHF compared to Zircaloy-4 and Inconel 600, respectively. Compared to the 2006 Groeneveld CHF lookup table, Fe-13Cr-6Al alloy gives a 13% increase in the tested flow boiling condition. Material properties are considered primarily responsible for the observed CHF differences among the tested materials. The surface thermal economy parameter $\frac{(pc_p)^{3/2}}{\sqrt{k}}$ is proposed as an explanation for the observed CHF differences; this parameter is related to material’s ability to avoid an irreversible dry spot formation. The apparent disagreement of Zircaloy-4 CHF with both the look up table predictions and Inconel 600 shows the limitation of departure of nuclate boiling (DNB) evaluations that do not consider cladding materials. The transient Fe-13Cr-6Al CHF is 39% and 23% higher than the lookup table prediction and the steady-state condition experimental result, respectively.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of bio-inspired flow fields in a mediated Li-S flow battery for grid energy storage

Lithium-sulfur is a redox flow battery with high energy density for applications in safe, reliable, and lasting scaling of energy. However, lithium-based batteries often encounter platting as a problem thanks to poor Li-ions deposition after cycling. Aiming to reduce this impact, a uniform and continuous flow of ions is needed. On this work, novel bio-inspired flow fields in the electrochemical cell were tested to improve ions flowability and lithium platting control, ultimately enhancing battery performance and life. To secure Li-S efficient, low-cost, and secure energy storage capabilities, we chose a configuration with decamethylferrocene and cobaltocene acting as redox mediators, Li metal as anode and sulfur kept in a separate catholyte reservoir. Flow test and battery results insinuated a beneficial influence of bio-inspired designs in flowing electrolyte uniformly with less pressure and pump power in comparison to other conventional designs used in the industry, with an encouraging ability to approach a cheap, safe, and reliable Li-S grid energy storage.

25 ENERGY STORAGE↗

Experimental study on heat transfer to supercritical water flowing through tubes

A test facility named SWAMUP (Supercritical Water Multi-Purpose Loop) has been constructed in Shanghai Jiao Tong Univ. to investigate heat transfer and pressure drop through tubes and rod bundles. SWAMUP is a closed loop with operating pressure up to 30 MPa, outlet-water temperature up to 550 deg. C, and mass flow rate up to 5 t/h. In this paper, experimental study has been carried out on heat transfer of supercritical water flowing vertically through tubes (ID=7.6 and 10 mm). A large number of test points in tubes has been obtained with a wide range of heat flux (200-1500 kw/m{sup 2}) and mass flux (450-2000 kg/m{sup 2}s). Test results showed that heat transfer deterioration (HTD) caused by buoyancy effect only appears in upward flow and HTD caused by acceleration effect appears both in upward flow and downward flow. The heat transfer coefficients (HTC) produced in tube tests were compared with existing heat transfer correlations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Epsilon Metal Summary Report Fiscal Year 2011

The Epsilon-metal (ε-metal) phase was selected in FY 2009 as a potential waste form to for immobilizing the noble metals found in the undissolved solids + aqueous stream, and the soluble Tc from ion-exchange process, each resulting from proposed aqueous reprocessing. ε-metal phase is observed in used nuclear fuel and the natural reactors of Oklobono in Gabon, where the long-term corrosion behavior was demonstrated. This makes ε-metal a very attractive waste form. Last fiscal year, ε-metal was successfully fabricated by combining the five-metals, Mo, Ru, Rh, Pd and Re (surrogate for Tc), into pellets followed by consolidation with an arc melter. The arc melter produced fully dense samples with the epsilon structure. However, some chemistry differences were observed in the microstructure that resulted in regions rich in Re and Mo, and others rich in Pd, while Ru and Rh remained fairly constant throughout. This year, thermal stability (air), and corrosion testing of the samples fabricated by arc melting were the main focus for experimental work. Thermal stability was measured with a differential scanning calorimeter - thermogravimetric analyzer, by both ramp heating as well as step heating. There is clear evidence during the ramp heating experiment of an exothermic event + a weight loss peak both beginning at ≈700°C. Step heating showed an oxidation event at ≈690°C with minimal weight gain that occurs just before the weight loss event at 700°C. The conclusion being that the e-metal begins to oxidize and then become volatile. These findings are useful for considering the effects of voloxidation process. Three different pellets were subjected to electrochemical testing to study the corrosion behavior of the epsilon-metal phase in various conditions, namely acidic, basic, saline, and inert. Test was done according to an interim procedure developed for the alloy metal waste form. First an open circuit potential was measured, followed by linear polarization sweeps. The linear polarization sweep range was the Tafel equation was fit to the linear polarization sweep data to determine the corrosion rate of each pellet in each test solution. The average calculated corrosion rates of the three pellets according to solution conditions were: -1.91 x 10 -4 mm/yr (0.001 M NaOH), -1.48 x 10 -3 mm/yr (0.01 M NaCl), -8.77 x 10 -4 mm/yr (0.001 M H 2 SO 4 ), -2.09 x 10 -3 mm/yr (0.001 M NaOH + 0.01 M NaCl), and -1.54 x 10 -3 mm/yr (0.001 M H 2 SO 4 + 0.01 M NaCl). Three single-pass flow through (SPFT) test were conducted at a flow rate of 10 ml/day, at 90°C, and pH of 2.5, 7.0, and 9.0 for up to 322 days. Results of the tests indicate that dissolution rates were 5 x 10 -4 g m -2 d -1 at pH 9.0, 1.2 x 10 -4 g m -2 d -1 at pH 7.0, and 2 x 10 -4 g m -2 d -1 at pH 2.5. The sample used for the pH 7.0 SPFT test contains extra Re compared to samples used for the other two SPFT test, which came from a single pellet. The corrosion data measured this year indicate that the ε-metal phase is chemically durable. The two chemically different phases, but structurally the same, behave differently during dissolution according to the microstructure changes observed in both the electrochemical and in SPFT test. Characterization of the test specimens after testing suggests that the dissolution is complex and involves oxidative dissolution followed by precipitation of both oxide and metallic phases. These data suggest that the dissolution in the electrochemical and SPFT tests is different; a process that needs further investigation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Field test and simulation evaluation of variable refrigerant flow systems performance

Our study aims to compare the performance of a Variable Refrigerant Flow (VRF) system with a Roof Top Unit, (RTU) and a variable-air-volume (VAV) system through field tests and energy simulations. The field test was conducted in as similar conditions as possible between the two systems, such as the installation and operating environments of heating, the ventilation and air conditioning (HVAC) system, including internal heat gain and outdoor conditions, including buildings to compare the performance of the two systems accurately. A VRF system and RTU were installed at the test building located in Oak Ridge, Tennessee, in the USA. The same internal heat gain was generated at the same operating time of the two systems using lighting, electric heaters, and humidifiers inside the building. The HVAC system was alternately operated between cooling and heating operations to acquire energy performance data and to compare energy usage. Furthermore, an hourly building energy simulation model was developed with regard to the VRF system and RTU, and then the model was calibrated using actual measured data. Then, annual energy consumption of the two systems were compared and analyzed using the calibrated model. Moreover, additional analysis was conducted when the controlled discharge air temperature in the RTU was changed. The field test result showed that when energy consumptions of two systems were compared at the same outdoor conditions, using the weather-normalized model, the VRF system exhibited an energy reduction of approximately 17% during cooling operation and of approximately 74% during heating operations. A comparison on the annual energy consumption using simulations showed that the VRF system reduced energy consumption more than that of the RTU by 60%. Furthermore, when the discharge air temperature in the RTU was controlled according to the outdoor air temperature, energy consumption of the RTU was reduced by 6% in cooling operations and by 18% in heating operation. As a result, energy consumption of the VRF system was reduced by more than that of the RTU by 55% approximately.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of an Advanced Hydrogen Energy Storage System using Aerogel in a Cryogenic Flux Capacitor

The Cryogenic Flux Capacitor (CFC) is a cold, dense fluid storage core with integrated design features that afford the designer flexibility and provide new possibilities for the storage and discharge of energy. The stored energy, in this case, is represented by hydrogen physically bonded within the nanoscale pores within the aerogel composite blanket material, and the process of bonding or debonding is governed by the principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m 2 /g) allows for storage densities close to, or in some cases exceeding, that of normal boiling point liquids. Its performance easily exceeds what can be achieved via ambient temperature and high-pressure gas storage for an equivalent volume. CFC storage is predicted to be easily scalable, constructed from readily available commercial materials, and lends itself to a range of pressure applications. The project team designed and manufactured the CFC, integrating it into a set of temperature-controlled flow loops. The CFC test setup was validated against existing data from previous NASA work. Tests used bottled hydrogen gas for test validation. A cryogenic fluid, nitrogen, flowed through a metered control system. Hydrogen temperature, pressure, and flow rates, as well as the temperature control targets, provided all necessary control targets. The team analyzed the recorded data and updated the Technology Maturation Plan based on the results of the test, making recommendations for a follow-up test, scale-up, and maturation pathway. For the engineering development and maturation of CFC hydrogen storage technology, a Techno-Economic Assessment (TEA) and Commercialization Plan for the integration of this technology with various power generation assets were produced. A companion analytical model was developed, experimentally validated, compared against performance metric, and used to tune the model and scale up the technology.

08 HYDROGEN↗

An Overview of the EGS Collab Project: Field Validation of Coupled Process Modeling of Fracturing and Fluid Flow at the Sanford Underground Research Facility, Lead, SD

Enhanced Geothermal Systems (EGS) development will require an ability to accurately predict the flow rates and temperatures of the production wells. While simple in concept, complex heterogeneous fracture pathways can lead to channeling, short-circuiting, and premature thermal breakthrough complicating EGS. The EGS Collab project will establish a suite of intermediate-scale (~10-20 m) field test beds coupled with stimulation and interwell flow tests to provide a basis to better understand the fracture geometries and processes that control heat transfer between rock and stimulated fractures. These experiments will provide a means of testing tools, codes, and concepts that could later be employed under geothermal reservoir conditions at FORGE and in EGS. We will perform well-controlled, in situ experiments focused on rock fracture behavior and permeability enhancement. Pre- and post-test modeling of each test will allow for model prediction and validation. Comprehensive instrumentation will be used to collect high-quality, high-resolution geophysical and fracture characterization and fluid flow data. ,These data will be analyzed and compared with models and field observations to further elucidate the basic relationships between stress, induced seismicity, and permeability enhancement. To the maximum extent achievable, we will observe and quantify other key governing parameters that impact permeability, and attempt to understand how these parameters might change throughout the development and operation of an EGS project with the goal of enabling commercial viability of EGS. The Sanford Underground Research Facility (SURF) in South Dakota was selected as the EGS Collab project experimental site based on the evaluation of information from several sites. Our team has designed and constructed the first field experiment planned for this project, which is supported by the US Department of Energy’s Geothermal Technologies Office.

EGS, FORGE, field fracture stimulation and flow ex↗

Reactive Transport Modeling with Physics-Informed Machine Learning for Critical Minerals Applications

This study presents a physics-informed neural network (PINN) framework for reactive transport modeling for simulating fast bimolecular reactions in porous media. Accurate characterization of cAhemical interactions and product formation in surface and subsurface environments is essential for advancing critical mineral extraction and related geoscience applications. The proposed methodology sequentially addresses the flow and diffusion–reaction subproblems. The flow field is computed using a mixed formulation, while the diffusion–reaction system is modeled via two uncoupled tensorial diffusion equations reformulated in terms of chemical invariants. PINNs are employed to solve the governing equations, enabling data-efficient, mesh-free prediction of chemical concentration fields. The framework is validated through a series of benchmark problems involving flow in heterogeneous porous media. Initial verification is conducted using patch tests for the flow field, followed by validation of the transport problem with emphasis on preserving non-negativity of concentrations. The complete fast bimolecular reaction scenario is then solved, yielding spatial distributions of reactants and product species. Results demonstrate that the PINNs-based approach effectively captures sharp, mixing-limited reaction fronts and dispersive mixing behavior, offering reliable predictions of reactive plume evolution. These capabilities are crucial for evaluating long-term subsurface behavior in applications such as fluid storage, energy extraction, and efficient extraction of critical minerals.

42 ENGINEERING↗

A universal velocity transformation for boundary layers with pressure gradients

The logarithmic law of the wall does not capture the mean flow when a boundary layer is subjected to a strong pressure gradient. In such a boundary layer, the mean flow is affected by the spatio-temporal history of the imposed pressure gradient; and accounting for history effects remains a challenge. This work aims to develop a universal mean flow scaling for boundary layers subjected to arbitrary adverse or/and favourable pressure gradients. Here, we derive from the Navier–Stokes equation a velocity transformation that accounts for the history effects and maps the mean flow to the canonical law of the wall. The transformation is tested against channel flows with a suddenly imposed adverse or favourable pressure gradient, boundary layer flows subjected to an adverse pressure gradient, and Couette–Poiseuille flows with a streamwise pressure gradient. It is found that the transformed velocity profiles follow closely the equilibrium law of the wall.

97 MATHEMATICS AND COMPUTING↗

Time-Resolved PIV Measurements of Flow Field at the Exit of a Diffuser Mounted on a Rotating Detonation Combustor

Time-resolved particle image velocimetry at 30 kHz is applied to the exhaust flow field of a RDC system configured with a diffuser geometry and a converging-diverging (CD) nozzle. The RDC is operated with methane fuel and oxygen-enriched air, motivated by power generation applications. The measured flow-field is discretized into axial and non-axial velocity components. Results are shown to characterize the flow-field across a cord length at the exit plane. Instantaneous contours of the two velocity components, and 1D histograms of velocity components, and 2D histograms of total velocity and tilt angle are shown at multiple locations in the flow. Repeatability of the data is evaluated by comparing tests conducted at similar flow rates. Results are presented for a baseline test case, and test cases showing the effect of reactant higher flow rate and CD nozzle geometry. Finally, the results are compared to a previous RDC study without the diffuser to compare the effectiveness of the diffuser and CD nozzle designs in mitigating the flow periodicity at the combustor exit.

particle image velocimetry, pressure gain combusti↗

Time-Resolved PIV Measurements of Flow Field at Diffuser Exit Downstream of a Rotating Detonation Combustor

Time-resolved particle image velocimetry at 30 kHz is applied to the exhaust flow field of a RDC system configured with a diffuser geometry and a converging-diverging (CD) nozzle. The RDC is operated with methane fuel and oxygen-enriched air, motivated by power generation applications. The measured flow-field is discretized into axial and non-axial velocity components. Results are shown to characterize the flow-field across a cord length at the exit plane. Instantaneous contours of the two velocity components, and 1D histograms of velocity components, and 2D histograms of total velocity and tilt angle are shown at multiple locations in the flow. Repeatability of the data is evaluated by comparing tests conducted at similar flow rates. Results are presented for a baseline test case, and test cases showing the effect of reactant higher flow rate and CD nozzle geometry. Finally, the results are compared to a previous RDC study without the diffuser to compare the effectiveness of the diffuser and CD nozzle designs in mitigating the flow periodicity at the combustor exit.

03 NATURAL GAS↗

WHEN SHOCK WAVES COLLIDE

Supersonic outflows from objects as varied as stellar jets, massive stars, and novae often exhibit multiple shock waves that overlap one another. When the intersection angle between two shock waves exceeds a critical value, the system reconfigures its geometry to create a normal shock known as a Mach stem where the shocks meet. Mach stems are important for interpreting emission-line images of shocked gas because a normal shock produces higher postshock temperatures, and therefore a higher-excitation spectrum than does an oblique shock. In this paper, we summarize the results of a series of numerical simulations and laboratory experiments designed to quantify how Mach stems behave in supersonic plasmas that are the norm in astrophysical flows. The experiments test analytical predictions for critical angles where Mach stems should form, and quantify how Mach stems grow and decay as intersection angles between the incident shock and a surface change. While small Mach stems are destroyed by surface irregularities and subcritical angles, larger ones persist in these situations and can regrow if the intersection angle changes to become more favorable. The experimental and numerical results show that although Mach stems occur only over a limited range of intersection angles and size scales, within these ranges they are relatively robust, and hence are a viable explanation for variable bright knots observed in Hubble Space Telescope images at the intersections of some bow shocks in stellar jets.

79 ASTRONOMY AND ASTROPHYSICS↗

The dissolution behavior of borosilicate glasses in far-from equilibrium conditions

In far-from-equilibrium conditions, the dissolution of borosilicate glasses used to immobilize nuclear waste is known to be a function of both temperature and pH. The aim of this paper is to study effects of these variables on three model waste glasses (SON68, ISG, AFCI). To do this, experiments were conducted at temperatures of 23, 40, 70, and 90 °C and pH(RT) values of 9, 10, 11, and 12 with the single-pass flow-through (SPFT) test method. The results from these tests were then used to parameterize a kinetic rate model based on transition state theory. Both the absolute dissolution rates and the rate model parameters are compared with previous results. Discrepancies in the absolute dissolution rates as compared to those obtained using other test methods are discussed. Rate model parameters for the three glasses studied here are nearly equivalent within error and in relative agreement with previous studies. The results were analyzed with a linear multivariate regression (LMR) and a nonlinear multivariate regression performed with the use of the Glass Corrosion Modeling Tool (GCMT), which is capable of providing a robust uncertainty analysis. This robust analysis highlights the high degree of correlation of various parameters in the kinetic rate model. As more data are obtained on borosilicate glasses with varying compositions, the effect of glass composition on the rate parameter values could possibly be obtained. This would allow for the possibility of predicting the forward dissolution rate of glass based solely on composition

Neeway, James J.↗

ACCELEROMETERS IN FLOW FIELDS: A STRUCTURAL ANALYSIS OF THE CHOPPED DUMMY INPILE TUBE

Four tests characterizing the structural response of the Chopped-Dummy In-Pile tube (CDIPT) experiment design were measured in the Hydro-Mechanical Fuel Test Facility (HMFTF). Four different test configurations were tried. These configurations tested the pressure drop and flow impact of various plate configurations and flow control orifices to be used later at different reactor power levels. Accelerometers were placed on the test vehicle and flow simulation housing. A total of five accelerometers were used with one on the top and bottom of the flow simulator and vehicle, and one on the outside of the flow simulator. Data were collected at a series of flow rates for 5 seconds each at an acquisition rate of 2 kHz for a Nyquist frequency of 1 kHz. The data were then analyzed using a Fast Fourier Transform (FFT) algorithm. The results show very coherent vibrations of the CDIPT experiment on the order of 50 Hz in frequency and 0.01 m/s2 in magnitude. The coherent vibrations, although small in magnitude pose a potential design problem if the frequencies coincide with the natural frequency of the fueled plates or test vehicle. The accelerometer data was integrated and combined to create a 3D trace of the experiment during the test. The merits of this data as well as further anomalies and artifacts are also discussed as well as their relation to the instrumentation and experiment design.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗