Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “false positive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Evaluation of Automatic Atlas-Based Lymph Node Segmentation for Head-and-Neck Cancer

Purpose: To evaluate if automatic atlas-based lymph node segmentation (LNS) improves efficiency and decreases inter-observer variability while maintaining accuracy. Methods and Materials: Five physicians with head-and-neck IMRT experience used computed tomography (CT) data from 5 patients to create bilateral neck clinical target volumes covering specified nodal levels. A second contour set was automatically generated using a commercially available atlas. Physicians modified the automatic contours to make them acceptable for treatment planning. To assess contour variability, the Simultaneous Truth and Performance Level Estimation (STAPLE) algorithm was used to take collections of contours and calculate a probabilistic estimate of the 'true' segmentation. Differences between the manual, automatic, and automatic-modified (AM) contours were analyzed using multiple metrics. Results: Compared with the 'true' segmentation created from manual contours, the automatic contours had a high degree of accuracy, with sensitivity, Dice similarity coefficient, and mean/max surface disagreement values comparable to the average manual contour (86%, 76%, 3.3/17.4 mm automatic vs. 73%, 79%, 2.8/17 mm manual). The AM group was more consistent than the manual group for multiple metrics, most notably reducing the range of contour volume (106-430 mL manual vs. 176-347 mL AM) and percent false positivity (1-37% manual vs. 1-7% AM). Average contouring time savings with the automatic segmentation was 11.5 min per patient, a 35% reduction. Conclusions: Using the STAPLE algorithm to generate 'true' contours from multiple physician contours, we demonstrated that, in comparison with manual segmentation, atlas-based automatic LNS for head-and-neck cancer is accurate, efficient, and reduces interobserver variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Prospective Evaluation of Staging and Target Volume Definition of Lymph Nodes by {sup 18}FDG PET/CT in Patients With Squamous Cell Carcinoma of Thoracic Esophagus

Purpose: To determine an optimal standardized uptake value (SUV) threshold for detecting lymph node (LN) metastases in esophageal cancer using {sup 18}F-Fluorodeoxyglucose positron emission tomography/computer tomography ({sup 18}FDG PET/CT) and to define the resulting nodal target volume, using histopathology as a 'gold standard.' Methods: Sixteen patients with esophageal squamous cell carcinoma who underwent radical esophagectomy and three-field LN dissection after {sup 18}FDG PET/CT and CT scans were enrolled into this study. Locations of LN groups were recorded according to a uniform LN map. Diagnostic performance of different SUV thresholds was assessed by receiver operating characteristic analysis. The optimal cutoff SUV was determined by plotting the false-negative rate (FNR) and false-positive rate (FPR), the sum of both error rates (FNR+FPR), and accuracy against a hypothetical SUV threshold. For each patient, nodal gross tumor volumes (GTVNs) were generated with CT alone (GTVNCT), PET/CT (GTVNPET), and pathologic data (GTVNpath). GTVNCT or GTVNPET was compared with GTVNpath by means of a conformity index (CI), which is the intersection of the two GTVNs divided by the sum of them minus the intersection, e.g., CI{sub CT} and {sub path} = GTVN{sub CT} and {sub path}/(GTVN{sub CT}+ GTVN{sub path} - GTVN{sub CT} and {sub path}). Results: LN metastases occurred in 21 LN groups among the 144 specimens taken from the 16 patients. The area under the receiver operating characteristic curve was 0.9017 {+-} 0.0410. The plot of error rates showed a minimum of FNR+FPR for an SUV of 2.36, at which the sensitivity, specificity, and accuracy were 76.19%, 95.93%, and 93.06%, respectively, whereas those of CT were 33.33%, 94.31%, and 85.42% (p values: 0.0117, 0.7539, and 0.0266). Mean GTVN{sub CT}, GTVN{sub PET}, and GTVN{sub path} were 1.52 {+-} 2.38, 2.82 {+-} 4.51, and 2.68 {+-} 4.16cm{sup 3}, respectively. Mean CI{sub CT} and {sub path} and CI{sub PET} and {sub path} were 0.31 and 0.65 (p value = 0.0352). Conclusions: Diagnostic superiority of PET/CT at an SUV threshold of 2.36 over CT has potential value in nodal target volume definition, but whether this can contribute to better treatment outcomes needs prospective analyses of recurrences in a larger cohort of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PET-Based Treatment Response Evaluation in Rectal Cancer: Prediction and Validation

Purpose: To develop a positron emission tomography (PET)-based response prediction model to differentiate pathological responders from nonresponders. The predictive strength of the model was validated in a second patient group, treated and imaged identical to the patients on which the predictive model was based. Methods and Materials: Fifty-one rectal cancer patients were prospectively included in this study. All patients underwent fluorodeoxyglucose (FDG) PET-computed tomography (CT) imaging both before the start of chemoradiotherapy (CRT) and after 2 weeks of treatment. Preoperative treatment with CRT was followed by a total mesorectal excision. From the resected specimen, the tumor regression grade (TRG) was scored according to the Mandard criteria. From one patient group (n = 30), the metabolic treatment response was correlated with the pathological treatment response, resulting in a receiver operating characteristic (ROC) curve based cutoff value for the reduction of maximum standardized uptake value (SUV{sub max}) within the tumor to differentiate pathological responders (TRG 1-2) from nonresponders (TRG 3-5). The applicability of the selected cutoff value for new patients was validated in a second patient group (n = 21). Results: When correlating the metabolic and pathological treatment response for the first patient group using ROC curve analysis (area under the curve = 0.98), a cutoff value of 48% SUV{sub max} reduction was selected to differentiate pathological responders from nonresponders (specificity of 100%, sensitivity of 64%). Applying this cutoff value to the second patient group resulted in a specificity and sensitivity of, respectively, 93% and 83%, with only one of the pathological nonresponders being false positively predicted as pathological responding. Conclusions: For rectal cancer, an accurate PET-based prediction of the pathological treatment response is feasible already after 2 weeks of CRT. The presented predictive model could be used to select patients to be considered for less invasive surgical interventions or even a 'wait and see' policy. Also, based on the predicted response, early modifications of the treatment protocol are possible, which might result in an improved clinical outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of Mucosal Recurrent Nasopharyngeal Carcinomas After Radiotherapy With Narrow-Band Imaging Endoscopy

Purpose: This study evaluated the feasibility of screening mucosal recurrent nasopharyngeal carcinoma with narrow-band imaging (NBI) endoscopy. Methods and Materials: One hundred and six patients were enrolled. All patients underwent conventional white-light (WL) endoscopic examination of the nasopharynx followed by NBI endoscopy. Biopsies were performed if recurrence was suspected. Results: We identified 32 suspected lesions by endoscopy in WL and/or NBI mode. Scattered brown spots (BS) were identified in 22 patients, and 4 of the 22 who had negative MRI findings were histopathologically confirmed to be neoplasias that were successfully removed via endoscopy. A comparison of the visualization in NBI closer view corresponded to histopathological findings in 22 BS, and the prevalence rates of neoplasias in tail signs, round signs, and irregularities signs were 0% (0/6), 0% (0/7), and 44.4% (4/9), respectively (p = 0.048). The sensitivity, specificity, and diagnostic capability were 37.5%, 92.9% and 0.652 for WL, 87.5%, 74.5% and 0.810 for NBI, and 87.5%, 87.8%, and 0.876 for NBI closer view, respectively. NBI closer view was effective in increasing specificity compared with NBI alone (87.8% vs. 74.5%, p < 0.05), and in increasing sensitivity and diagnostic capability compared to WL alone (87.5% vs. 37.5%, p < 0.05; 0.876 vs. 0.652, p = 0.0001). Conclusions: Although NBI in endoscopy can improve sensitivity of mucosal recurrent nasopharyngeal neoplasias, false-positive (nonneoplasia BS) results may be obtained in areas with nonspecific inflammatory changes due to postradiation effects. NBI closer view not only can offer a timely, convenient, and highly reliable assessment of mucosal recurrent nasopharyngeal carcinoma, it can also make endoscopic removal possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-Dose Chest Computed Tomography for Lung Cancer Screening Among Hodgkin Lymphoma Survivors: A Cost-Effectiveness Analysis

Purpose: Hodgkin lymphoma (HL) survivors face an increased risk of treatment-related lung cancer. Screening with low-dose computed tomography (LDCT) may allow detection of early stage, resectable cancers. We developed a Markov decision-analytic and cost-effectiveness model to estimate the merits of annual LDCT screening among HL survivors. Methods and Materials: Population databases and HL-specific literature informed key model parameters, including lung cancer rates and stage distribution, cause-specific survival estimates, and utilities. Relative risks accounted for radiation therapy (RT) technique, smoking status (>10 pack-years or current smokers vs not), age at HL diagnosis, time from HL treatment, and excess radiation from LDCTs. LDCT assumptions, including expected stage-shift, false-positive rates, and likely additional workup were derived from the National Lung Screening Trial and preliminary results from an internal phase 2 protocol that performed annual LDCTs in 53 HL survivors. We assumed a 3% discount rate and a willingness-to-pay (WTP) threshold of $50,000 per quality-adjusted life year (QALY). Results: Annual LDCT screening was cost effective for all smokers. A male smoker treated with mantle RT at age 25 achieved maximum QALYs by initiating screening 12 years post-HL, with a life expectancy benefit of 2.1 months and an incremental cost of $34,841/QALY. Among nonsmokers, annual screening produced a QALY benefit in some cases, but the incremental cost was not below the WTP threshold for any patient subsets. As age at HL diagnosis increased, earlier initiation of screening improved outcomes. Sensitivity analyses revealed that the model was most sensitive to the lung cancer incidence and mortality rates and expected stage-shift from screening. Conclusions: HL survivors are an important high-risk population that may benefit from screening, especially those treated in the past with large radiation fields including mantle or involved-field RT. Screening may be cost effective for all smokers but possibly not for nonsmokers despite a small life expectancy benefit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase 2 Neoadjuvant Treatment Intensification Trials in Rectal Cancer: A Systematic Review

Multiple phase 2 trials of neoadjuvant treatment intensification in locally advanced rectal cancer have reported promising efficacy signals, but these have not translated into improved cancer outcomes in phase 3 trials. Improvements in phase 2 trial design are needed to reduce these false-positive signals. This systematic review evaluated the design of phase 2 trials of neoadjuvant long-course radiation or chemoradiation therapy treatment intensification in locally advanced rectal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

EHR-BERT: A BERT-based model for effective anomaly detection in electronic health records

Objective: Physicians and clinicians rely on data contained in electronic health records (EHRs), as recorded by health information technology (HIT), to make informed decisions about their patients. The reliability of HIT systems in this regard is critical to patient safety. Consequently, better tools are needed to monitor the performance of HIT systems for potential hazards that could compromise the collected EHRs, which in turn could affect patient safety. In this paper, we propose a new framework for detecting anomalies in EHRs using sequence of clinical events. This new framework, EHR-Bidirectional Encoder Representations from Transformers (BERT), is motivated by the gaps in the existing deep-learning related methods, including high false negatives, sub-optimal accuracy, higher computational cost, and the risk of information loss. EHR-BERT is an innovative framework rooted in the BERT architecture, meticulously tailored to navigate the hurdles in the contemporary BERT method; thus, enhancing anomaly detection in EHRs for healthcare applications.Methods: The EHR-BERT framework was designed using the Sequential Masked Token Prediction (SMTP) method. This approach treats EHRs as natural language sentences and iteratively masks input tokens during both training and prediction stages. This method facilitates the learning of EHR sequence patterns in both directions for each event and identifies anomalies based on deviations from the normal execution models trained on EHR sequences.Results: Extensive experiments on large EHR datasets across various medical domains demonstrate that EHR-BERT markedly improves upon existing models. It significantly reduces the number of false positives and enhances the detection rate, thus bolstering the reliability of anomaly detection in electronic health records. This improvement is attributed to the model’s ability to minimize information loss and maximize data utilization effectively.Conclusion: EHR-BERT showcases immense potential in decreasing medical errors related to anomalous clinical events, positioning itself as an indispensable asset for enhancing patient safety and the overall standard of healthcare services. The framework effectively overcomes the drawbacks of earlier models, making it a promising solution for healthcare professionals to ensure the reliability and quality of health data.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

A correlation based fault detection method for short circuits in battery packs

Here this paper presents a fault detection method for short circuits based on the correlation coefficient of voltage curves. The proposed method utilizes the direct voltage measurements from the battery cells, and does not require any additional hardware or effort in modeling during fault detection. Moreover, the inherent mathematical properties of the correlation coefficient ensure the robustness of this method as the battery pack ages or is imbalanced in real applications. In order to apply this method online, the recursive moving window correlation coefficient calculation is adopted to maintain the detection sensitivity to faults during operation. An additive square wave is designed to prevent false positive detections when the batteries are at rest. The fault isolation can be achieved by identifying the overlapped cell in the correlation coefficients with fault flags. Simulation and experimental results validated the feasibility and demonstrated the advantages of this method.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi phenomena melt pool sensor data fusion for enhanced process monitoring of laser powder bed fusion additive manufacturing

Finding actionable trends in laser-based metal additive manufacturing process monitoring data is challenging owing to the diversity and complexity of the underlying physical interactions. A single monitoring solution that captures a particular process phenomenon, such as a photodiode that tracks melt pool intensity, is not alone capable of evaluating process stability or detecting flaw formation with sufficient precision for routine application in industry. In this work, to improve flaw detection performance, we adopted a data fusion approach that captures multiple process phenomena. To demonstrate this, we acquired data from laser powder bed fusion (LPBF) builds of cylindrical specimens produced with different laser spot sizes, emulating defocusing due to process faults such as thermal lensing. The resulting specimens had porosity of varying types and severity, quantified by post-build non-destructive X-ray computed tomography, Archimedes density measurements, and destructive metallographic characterization. During the build, the melt pool state was monitored with two coaxial high-speed video cameras and a temperature field imaging system. Physically intuitive low-level melt pool signatures, such as melt pool temperature, shape and size, and spatter intensity were extracted from this high-dimensional, image-based sensor data. These process signatures were subsequently used as input features in relatively simple machine learning models, such as a support vector machine, which were trained to detect laser defocusing, and in addition, predict porosity type and severity. The results show that the data fusion approach significantly enhanced system performance by reducing the overall false positive rate from ~ 0.1 to ~ 0.001 without sacrificing the true positive rate (~0.90). These results were at par with a black-box, deep machine learning approach (convolutional neural network).

36 MATERIALS SCIENCE↗

Realization of predicted exotic materials: The burden of proof

Trove of exotic topoloid structures has recently been predicted by searching for compounds whose calculated band structure crossing points fulfill specific symmetry requirements. Discovery of exciting physical phenomena by experimental studies of such predicted compounds is just around the corner. Yet, the examination of some of these assumed high-symmetry structures suggests that not always will assembly of atoms in a configuration that yields exotic topological properties be protected against energy-lowering symmetry breaking modes. Indeed, although bulk topological characteristics lead to protected surface/edge states, nothing protects bulk states from structural instability. The burden of proof for theoretical predictions of exciting physical phenomena should include some compelling hints that such phenomena can live in thermodynamically stable (or near stable) compounds. Here, we illustrate how the use of the calculated total (electron + ion) energies of candidate structures can remove false-positive predicted topoloids from the list of likely realizable compounds, to the benefit of the much-cherished iterative process of theory-experiment materials discovery.

36 MATERIALS SCIENCE↗

Vector-model-supported optimization in volumetric-modulated arc stereotactic radiotherapy planning for brain metastasis

Long planning time in volumetric-modulated arc stereotactic radiotherapy (VMA-SRT) cases can limit its clinical efficiency and use. A vector model could retrieve previously successful radiotherapy cases that share various common anatomic features with the current case. The prsent study aimed to develop a vector model that could reduce planning time by applying the optimization parameters from those retrieved reference cases. Thirty-six VMA-SRT cases of brain metastasis (gender, male [n = 23], female [n = 13]; age range, 32 to 81 years old) were collected and used as a reference database. Another 10 VMA-SRT cases were planned with both conventional optimization and vector-model-supported optimization, following the oncologists' clinical dose prescriptions. Planning time and plan quality measures were compared using the 2-sided paired Wilcoxon signed rank test with a significance level of 0.05, with positive false discovery rate (pFDR) of less than 0.05. With vector-model-supported optimization, there was a significant reduction in the median planning time, a 40% reduction from 3.7 to 2.2 hours (p = 0.002, pFDR = 0.032), and for the number of iterations, a 30% reduction from 8.5 to 6.0 (p = 0.006, pFDR = 0.047). The quality of plans from both approaches was comparable. From these preliminary results, vector-model-supported optimization can expedite the optimization of VMA-SRT for brain metastasis while maintaining plan quality.

61 RADIATION PROTECTION AND DOSIMETRY↗

Exudate-based diabetic macular edema detection in fundus images using publicly available datasets

Diabetic macular edema (DME) is a common vision threatening complication of diabetic retinopathy. In a large scale screening environment DME can be assessed by detecting exudates (a type of bright lesions) in fundus images. In this work, we introduce a new methodology for diagnosis of DME using a novel set of features based on colour, wavelet decomposition and automatic lesion segmentation. These features are employed to train a classifier able to automatically diagnose DME through the presence of exudation. We present a new publicly available dataset with ground-truth data containing 169 patients from various ethnic groups and levels of DME. This and other two publicly available datasets are employed to evaluate our algorithm. We are able to achieve diagnosis performance comparable to retina experts on the MESSIDOR (an independently labelled dataset with 1200 images) with cross-dataset testing (e.g., the classifier was trained on an independent dataset and tested on MESSIDOR). Our algorithm obtained an AUC between 0.88 and 0.94 depending on the dataset/features used. Additionally, it does not need ground truth at lesion level to reject false positives and is computationally efficient, as it generates a diagnosis on an average of 4.4 s (9.3 s, considering the optic nerve localization) per image on an 2.6 GHz platform with an unoptimized Matlab implementation.

59 BASIC BIOLOGICAL SCIENCES↗

Source detection at 100 meter standoff with a time-encoded imaging system

Here, we present the design, characterization, and testing of a laboratory prototype radiological search and localization system. The system, based on time-encoded imaging, uses the attenuation signature of neutrons in time, induced by the geometrical layout and motion of the system. We have demonstrated the ability to detect a ~1 mCi 252 Cf radiological source at 100 m standoff with 90% detection efficiency and 10% false positives against background in 12 min. As a result, this same detection efficiency is met at 15 s for a 40 m standoff, and 1.2 s for a 20 m standoff.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancing the Fork detector for quantitative spent nuclear fuel verification

The Fork detector is widely used by the safeguards inspectorate of the European Atomic Energy Community (EURATOM) and the International Atomic Energy Agency (IAEA) to verify spent nuclear fuel. Fork measurements are routinely performed for safeguards prior to dry storage cask loading. Additionally, spent fuel verification will be required at the facilities where encapsulation is performed for acceptance in the final repositories planned in Sweden and Finland. The use of the Fork detector as a quantitative instrument has not been prevalent due to the complexity of correlating the measured neutron and gamma ray signals with fuel inventories and operator declarations. A spent fuel data analysis module based on the ORIGEN burnup code was recently implemented to provide automated real-time analysis of Fork detector data. This module allows quantitative predictions of expected neutron count rates and gamma units as measured by the Fork detectors using safeguards declarations and available reactor operating data. This study describes field testing of the Fork data analysis module using data acquired from 339 assemblies measured during routine dry cask loading inspection campaigns in Europe. Assemblies include both uranium oxide and mixed-oxide fuel assemblies. More recent measurements of 50 spent fuel assemblies at the Swedish Central Interim Storage Facility for Spent Nuclear Fuel are also analyzed. An evaluation of uncertainties in the Fork measurement data is performed to quantify the ability of the data analysis module to verify operator declarations and to develop quantitative go/no-go criteria for safeguards verification measurements during cask loading or encapsulation operations. The goal of this approach is to provide safeguards inspectors with reliable real-time data analysis tools to rapidly identify discrepancies in operator declarations and to detect potential partial defects in spent fuel assemblies with improved reliability and minimal false positive alarms. Finally, the results are summarized, and sources and magnitudes of uncertainties are identified, and the impact of analysis uncertainties on the ability to confirm operator declarations is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A neutron-gamma pulse shape discrimination method based on pure and mixed sources

We present a novel trainable approach to distinguish neutrons from gammas using a particle detector. Traditionally, Pulse Shape Discrimination (PSD) methods for this problem utilize an ad-hoc computation of tail signal energy to perform the detection. Our first contribution is a rigorous analysis of the performance of this existing approach on gold standard Time of Flight (TOF) data. While this approach performs well for high energy pulses, its accuracy drops dramatically as the pulse energy decreases. Our second contribution is a novel data driven classifier that is trained from two readily available sources: one that emits gamma particles (Cs-137), and another that emits a mixture of gamma and neutron particles (Cf-252). We test our approach using TOF experiments and show a marked improvement in accuracy over the traditional method for low false positive rates and low energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Increasing the detection sensitivity of the Radionuclide Aerosol Sampler/Analyzer using a cosmic veto system

Different configurations of a cosmic veto system have been evaluated for the Radionuclide Aerosol Sampler/Analyzer (RASA). The upgrade has the potential to resolve the issue that U.S. IMS radionuclide stations have difficulty meeting the 140Ba Minimum Detectable Concentration (MDC) certification requirement when the natural background radioactivity is high. It also aims to improve the detection sensitivity of the RASA system for other fission and activation products indicative of a nuclear explosion. This proof of principal utilizes a prototype RASA system located at Pacific Northwest National Laboratory (PNNL), and has demonstrated background reductions by up to 11.3% and improvements in the average MDC by up to 7.7%. Recommendations are made for either a 1 or 3 plate configuration, which improves the 140Ba MDC by 5.6% and 7.2% for a blank filter. Whilst elevated 212Pb activity remains problematic, the cosmic veto system provides a practical solution for sensitivity improvement with little design modification of the RASA. It also has value in improving sensitivity and preventing false-positives at remote U.S. IMS station locations where sample transfer for laboratory analysis is logistically difficult.

Comprehensive Nuclear-Test-Ban Treaty, RASA, Cosmi↗

Realistic application of short-lived fission product delayed neutron, gamma-ray analysis for simultaneous nondestructive trace quantification of U, Pu mixtures on cellulose swipes

Detection and characterization of fissile traces are of interest to the international nuclear nonproliferation community, including the International Atomic Energy Agency. Pre-inspection check samples are analyzed by neutron activation analysis at the High Flux Isotope Reactor operated by the Oak Ridge National Laboratory under the umbrella of the IAEA Network of Analytical Laboratories. The simultaneous quantification of U and Pu mixtures was accomplished using the combined delayed neutron (DN) delayed gamma-ray (DG) method to analyze cellulose swipes with actinide loading <1ng in a blind field trial. The total fissile quantity was measured by the DN counts and the relative proportions of U, Pu were determined by calibration of the 104 Tc / 141 Ba fission product count ratio using known mixtures. The DNDG method demonstrated high accuracy in flagging the presence of 239 Pu in uranium down to <100 pg mass loading. In conclusion, peak significance tests helped to control false positive Pu flagging and simultaneous quantification of U and Pu loading was accomplished on samples that passed the significance tests.

36 MATERIALS SCIENCE↗

Unsupervised anomaly detection in MeV ultrafast electron diffraction

MeV ultrafast electron diffraction (MUED) is a pump-probe technique used to study the dynamic structural evolution of materials. An ultrashort laser pulse triggers structural changes, which are then probed by an ultrashort relativistic electron beam. To overcome low signal-to-noise ratios, diffraction patterns are averaged over thousands of shots. However, shot-to-shot instabilities in the electron beam can distort individual patterns, introducing uncertainty. Improving MUED accuracy requires detecting and removing these anomalous patterns from large datasets. In this work, we developed a fully unsupervised methodology for the detection of anomalous diffraction patterns. Using a convolutional autoencoder, we calculate the reconstruction mean squared error of the diffraction patterns. Based on the statistical analysis of this error, we provide the user an estimation of the probability that the pattern is normal, which also allows a posterior visual inspection of the images that are difficult to classify. This method has been trained with only 100 diffraction patterns and tested on 1521 patterns, resulting in a false positive rate between 0.2% and 0.4%, with a training time of 10 s per image and a test time of about 1 s per image. Here, the proposed methodology can also be applied to other diffraction techniques in which large datasets are collected that include faulty images due to instrumental instabilities.

43 PARTICLE ACCELERATORS↗