Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “failure reports”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Cross-Cultural Barriers to Effective Communication in Aviation

Communication is essential to safe flight, as evidenced by several accidents in which crew communicates was found to have contributed to the accidents. This chapter documents the essential role of explicit efficient communication to flight safety with a global context. It addresses communication between flight crews and air traffic controllers in regions a the world where pilots and controllers speak different native languages, as well as cases in which crew members within the flight deck represent different native languages and cultures. It also addresses problems associated with "exporting" crew resource management training programs to parts of the world which values and norms differ from those of the United States, where these programs were initially developed. This chapter is organized around several central questions: (1) What are various kinds of communication failures and what are their consequences; (2) What are the causes of communication failure; (3) What are features of effective crew communication; (4) What can be done to enhance communication success? To explore a wider range of communication failures than available from accident reports, we examined a set of incident reports from the Aviation Safety Reporting System. These could be classified into three major categories: those in which language actually interfered with transmission of a message; those in which transmission was adequate but the context was not expressed unambiguously and thus the message received was not the same as the message intended; and those in which the message was received as intended, but was not adequately understood or acted upon, mainly because of cultural factors. The consequences of failed communication can be flight errors (such as when a clearance is not received correctly), loss of situation awareness, or failure of crew members (or ATC and pilots) to build a shared understanding of a situation. Causes of misunderstanding can be traced to a number of sources, often grounded in faulty assumptions held by one or both parties to a conversation. Speakers and listeners often experience "illusionary understanding" in which they think they understand each other, but in fact do not. While this problem can exist within a single culture, it is much more serious across cultures. Training in effective explicit communication is a component of Crew Resource Management training programs developed in the U.S. These programs are being adopted by airlines around the world, with varying degrees of success. The level of success in part depends on how similar the conversational and social styles of those cultures are to those of the U.S. A factor that influences conversational style is a culture's relative positioned on two major dimensions that distinguish national cultural groups: individualism vs. collectivism and degree of power distance. The chapter concludes with a discussion of techniques for overcoming the various classes of communication failures and for effectively adapting training programs to fit the values and norms of cultures around the globe.

Fischer, U.↗

Evaluation of Component Reliability in Photovoltaic Systems using Field Failure Statistics

Ongoing operations and maintenance (O&M) are needed to ensure photovoltaic (PV) systems continue to operate and meet production targets over the lifecycle of the system. Although average costs to operate and maintain PV systems have been decreasing over time, reported costs can vary significantly at the plant level. Estimating O&M costs accurately is important for informing financial planning and tracking activities, and subsequently lowering the levelized cost of electricity (LCOE) of PV systems. This report describes a methodology for improving O&M planning estimates by using empirically-derived failure statistics to capture component reliability in the field. The report also summarizes failure patterns observed for specific PV components and local environmental conditions observed in Sandia's PV Reliability, Operations & Maintenance (PVROM) database, a collection of field records across 800+ systems in the U.S. Where system-specific or fleet-specific data are lacking, PVROM-derived failure distribution values can be used to inform cost modeling and other reliability analyses to evaluate opportunities for performance improvements.

14 SOLAR ENERGY↗

Propagation testing multi-cell batteries.

Propagation of single point or single cell failures in multi-cell batteries is a significant concern as batteries increase in scale for a variety of civilian and military applications. This report describes the procedure for testing failure propagation along with some representative test results to highlight the potential outcomes for different battery types and designs.

25 ENERGY STORAGE↗

Causal Analysis For Occurrence Report: OR NA-SS-SNL-2000-2015-0005 Unexpected Type of Failure of Thermal Battery

On 6/26/2015 at approximately 1445 in 894/136, a pulse thermal battery (approximately the size of a commercial size C cell) experienced an unexpected failure following an electrical performance test that is routinely conducted on thermal batteries. A dedicated tester for this operation was used and it ran the test until the nominal 28-volt output of the battery had dropped to 5 volts, usually indicative of the battery being spent and safe enough to move. The failure occurred while a test operator was transferring the battery from the testing primary containment box to another primary containment box within the same room; initial indications are that the battery experienced an over-pressurization failure which led to the battery's base plate being expelled and the operator receiving a non-recordable injury (bruising to the palm of the hand) from the pressure of the expulsion. The operator was wearing the prescribed PPE (safety glasses and high temperature glove) and was handling the battery appropriately with an open, flat hand. Pictures of the scene are below.

25 ENERGY STORAGE↗

Near-Miss Evaluation Bias as an Obstacle to Organizational Learning: Lessons from NASA

After the Shuttle Columbia catastrophe, the investigation board (CAIB) stated that NASA needs to develop a "learning culture", meaning a capability to learn from past failures by understanding the technical and organizational causes of these mistakes (CAIB report, 2003). While many organizations learn from obvious failures, we argue that it is harder for organizations to learn from near-miss events (i.e., situations where a failure does not occur but nearly did), because these near-misses are processed as successes. For the shuttle program, prior debris problems could have caused a similar failure as on the Columbia mission except that the large pieces missed the highly sensitive portions of the orbiter. This acceptance of foam debris was adopted as a normal occurrence by the shuttle program managers similar to the problems at the time of the Challenger Disaster (detailed in Vaughan, 1996). We extend that work to show that an outcome bias influences people's evaluation of project managers, such that managers of failed missions were perceived more poorly than managers who made the same decisions but whose mission ended in either success or a near-miss. The similarity of ratings between the near-miss and success condition imply that even when a problem occurs that is clearly linked to prior managerial decisions, if the project is not harmed because of good luck, that manager is not held accountable for faculty decision making and neither the individual manager nor the organization learn from the experience potentially increasing the likelihood of a failure in the future.

Dillon, Robin L.↗

Failures of CMOS Circuits Irradiated At Low Rates

Report describes experiments on irradiation of SGS 4007 complementary metal oxide/semiconductor (CMOS) integrated inverter circuits by 60Co and 137Cs radioactive sources. Purpose of experiments to supplement previous observations that minimum radiation doses at which failure occurred in more-complicated CMOS parts were lower at lower dose rates.

Goben, Charles A.↗

Modeling and Characterization of Dynamic Failure of Borosilicate Glass under Compression/Shear Loading

In this paper, we study the impact-induced dynamic failure of a borosilicate glass block using an integrated experimental/analytical approach. Previous experimental studies on dynamic failure of borosilicate glass have been reported by Nie et al.1 using the Split Hopkinson Pressure Bar (SHPB) technique. The damage growth patterns and stress histories have been reported for various glass specimen designs. In this study, we propose to use a continuum damage mechanics (CDM)-based constitutive model to describe the initial failure and subsequent stiffness reduction of glass. Explicit finite element analyses are used to simulate the glass specimen impact event. A maximum shear stress-based damage evolution law is used in describing the glass damage process under combined compression/shear loading. The impact test results are used in quantifying the critical shear stress for the borosilicate glass under examination. It is shown that with only two modeling parameters, reasonably good comparisons between the predicted and the experimentally measured failure maps can be obtained for various glass sample geometries. Comparisons between the predicted stress histories for different sample designs are also used as model validations.

36 MATERIALS SCIENCE↗

AGR-3/4 Irradiation Test Predictions using PARFUME

PARFUME, a fuel performance modeling code used for high temperature gas reactors, was used to model the AGR-3/4 irradiation test using as-run physics and thermal hydraulics data. The AGR-3/4 test is the combined third and fourth planned irradiations of the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. The AGR-3/4 test train consists of twelve separate and independently controlled and monitored capsules. Each capsule contains four compacts filled with both uranium oxycarbide (UCO) unaltered “driver” fuel particles and UCO designed-to-fail (DTF) fuel particles. The DTF fraction was specified to be 1×10-2. This report documents the calculations performed to predict failure probability of TRISO-coated fuel particles during the AGR-3/4 experiment. In addition, this report documents the calculated source term from both the driver fuel and DTF particles. The calculations include the modeling of the AGR-3/4 irradiation that occurred from December 2011 to April 2014 in the Advanced Test Reactor (ATR) over a total of ten ATR cycles including seven normal cycles, one low power cycle, one unplanned outage cycle, and one Power Axial Locator Mechanism cycle. Results show that failure probabilities are predicted to be low, resulting in zero fuel particle failures per capsule. The primary fuel particle failure mechanism occurred as a result of localized stresses induced by the calculated IPyC cracking. Assuming 1,872 driver fuel particles per compact, failure probability calculated by PARFUME leads to no predicted particle failure in the AGR-3/4 driver fuel. In addition, the release fraction of fission products Ag, Cs, and Sr were calculated to vary depending on capsule location and irradiation temperature. The maximum release fraction of Ag occurs in Capsule 7 reaching up to 56% for the driver fuel and 100% for the DTF fuel. The release fraction of the other two fission products, Cs and Sr, are much smaller and in most cases less than 1% for the driver fuel. The notable exception occurs in Capsule 7 where the release fraction for Cs and Sr reach up to 0.73% and 2.4%, respectively, for the driver fuel. For the DTF fuel in Capsule 7, the release fraction for Cs and Sr are estimated to be 100% and 5%, respectively.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Distribution System Model Calibration for GMLC 3.3.3 "Incipient Failure Identification for Common Grid Asset Classes" - Project Summary

Distribution system model calibration is a key enabling task for incipient failure identification within the distribution system. This report summarizes the work and publications by Sandia National Laboratories on the GMLC project titled “Incipient Failure Identification for Common Grid Asset Classes”. This project was a joint effort between Sandia National Laboratories, Lawrence Livermore National Laboratory, National Energy Technology Laboratory, and Oak Ridge National Laboratory. The included work covers distribution system topology identification, transformer groupings, phase identification, regulator and tap position estimation, and the open-source release and implementation of the developed algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Study of Failure Criteria of Fibrous Composite Materials

The research described in this paper is focused on two areas: (1) evaluation of existing composite failure criteria in the nonlinear, explicit transient dynamic finite element code, MSC.Dytran, and (2) exploration of the possibilities for modification of material and failure models to account for large deformations, progressive failure, and interaction of damage accumulation with stress/strain response of laminated composites. Following a review of the MSC.Dytran user manual, a bibliographical review of existing failure criteria of composites was performed. The papers considered most interesting for the objective of this report are discussed in section 2. The failure criteria included in the code under consideration are discussed in section 3. A critical summary of the present procedures to perform analysis and design of composites is presented in section 4. A study of the most important historical failure criteria for fibrous composite materials and some of the more recent modifications proposed were studied. The result of this analysis highlighted inadequacies in the existing failure criteria and the need to perform some numerical analyses to elucidate the answer to questions on which some of the proposed criteria are based. A summary of these ideas, which is a proposal of studies to be developed, is presented in section 5. Finally, some ideas for future developments are summarized in section 6.

Paris, Federico↗

An investigation of theories of failure for ceramic matrix composites

This final report is comprised of the abstract of a masters thesis research grant. The abstract of the thesis, 'An Investigation of Acoustic Emission Techniques for the Discrimination of Damage Mechanisms in Ceramic Matrix Composites', is as follows: In order to further advance the understanding of the mechanical behavior of ceramic matrix composites (CMS's), acoustic emission (AE) techniques were implemented to monitor and identify damage mechanisms in CMC's under tensile loading. In addition to real-time AE monitoring techniques, a data acquisition system was developed and implemented in order to capture AE waveforms resulting from stress-induced damage. Waveforms were inspected for multiple events, separated in distinct events, and then analyzed to determine waveform characteristics in the time and frequency domains. Waveform characteristics included peak amplitude, event duration, MARSE, energy, and dominant and centroidal frequency. In addition to conventional methods for determining a damage discrimination criteria, a study of the distribution and correlation of the waveform characteristics criteria and a study of the distribution and correlation of the waveform characteristics were performed to aid in the determination of a damage discrimination criteria. The damage discrimination criteria was tested for 'uniqueness', i.e., the effectiveness of the criteria to identify and monitor damage independent of the stress-strain relationship. Insitu radiography was used to substantiate the damage accumulation. A simulation test was also performed over the loading history to study the changes in the waveform characteristics of the system response from a constant excitation. This thesis demonstrates the use of waveform analysis to study the AE activity resulting from stress-induced damage in CMC's in conjunction with other nondestructive evaluation techniques to investigate the mechanical behavior of CMC's.

Hemann, John H.↗

Simulating Fatigue Crack Growth in Spiral Bevel Pinion

This project investigates computational modeling of fatigue crack growth in spiral bevel gears. Current work is a continuation of the previous efforts made to use the Boundary Element Method (BEM) to simulate tooth-bending fatigue failure in spiral bevel gears. This report summarizes new results predicting crack trajectory and fatigue life for a spiral bevel pinion using the Finite Element Method (FEM). Predicting crack trajectories is important in determining the failure mode of a gear. Cracks propagating through the rim may result in catastrophic failure, whereas the gear may remain intact if one tooth fails and this may allow for early detection of failure. Being able to predict crack trajectories is insightful for the designer. However, predicting growth of three-dimensional arbitrary cracks is complicated due to the difficulty of creating three-dimensional models, the computing power required, and absence of closed- form solutions of the problem. Another focus of this project was performing three-dimensional contact analysis of a spiral bevel gear set incorporating cracks. These analyses were significant in determining the influence of change of tooth flexibility due to crack growth on the magnitude and location of contact loads. This is an important concern since change in contact loads might lead to differences in SIFs and therefore result in alteration of the crack trajectory. Contact analyses performed in this report showed the expected trend of decreasing tooth loads carried by the cracked tooth with increasing crack length. Decrease in tooth loads lead to differences between SIFs extracted from finite element contact analysis and finite element analysis with Hertz contact loads. This effect became more pronounced as the crack grew.

Ural, Ani↗

MO-G-BRE-09: Validating FMEA Against Incident Learning Data: A Study in Stereotactic Body Radiation Therapy

Purpose: Though FMEA (Failure Mode and Effects Analysis) is becoming more widely adopted for risk assessment in radiation therapy, to our knowledge it has never been validated against actual incident learning data. The objective of this study was to perform an FMEA analysis of an SBRT (Stereotactic Body Radiation Therapy) treatment planning process and validate this against data recorded within an incident learning system. Methods: FMEA on the SBRT treatment planning process was carried out by a multidisciplinary group including radiation oncologists, medical physicists, and dosimetrists. Potential failure modes were identified through a systematic review of the workflow process. Failure modes were rated for severity, occurrence, and detectability on a scale of 1 to 10 and RPN (Risk Priority Number) was computed. Failure modes were then compared with historical reports identified as relevant to SBRT planning within a departmental incident learning system that had been active for two years. Differences were identified. Results: FMEA identified 63 failure modes. RPN values for the top 25% of failure modes ranged from 60 to 336. Analysis of the incident learning database identified 33 reported near-miss events related to SBRT planning. FMEA failed to anticipate 13 of these events, among which 3 were registered with severity ratings of severe or critical in the incident learning system. Combining both methods yielded a total of 76 failure modes, and when scored for RPN the 13 events missed by FMEA ranked within the middle half of all failure modes. Conclusion: FMEA, though valuable, is subject to certain limitations, among them the limited ability to anticipate all potential errors for a given process. This FMEA exercise failed to identify a significant number of possible errors (17%). Integration of FMEA with retrospective incident data may be able to render an improved overview of risks within a process.

60 APPLIED LIFE SCIENCES↗

Wind turbine main bearing rating lives as determined by IEC 61400‐1 and ISO 281: A critical review and exploratory case study

Abstract This paper studies the rating lives of wind turbine main bearings, as determined by the IEC 61400‐1 and ISO 281 standards. A critical review of relevant bearing life theory and turbine design requirements is provided, including discussion on possible shortcomings such as the existence (or not) of the bearing fatigue load limit and the validity of assuming linear damage accumulation. A detailed exploratory case study is then undertaken to determine rating lives for two models of main bearing in a 1.5 MW wind turbine. Rating life assessment is carried out under different conditions, including various combinations of main bearing temperature, wind field characteristics, lubricant viscosity, and contamination levels. Rating lives are found to be sufficiently above the desired 20‐year design life for both bearing models under expected operating conditions. For the larger bearing, operational loads are shown to be below or close to the bearing fatigue load limit a vast majority of the time. Key sensitivities for rating life values are temperature and contamination. Overall, the results of this study suggest that an ISO 281 rating life assessment does not account for reported rates of main bearing failures in 1 to 3 MW wind turbines. It is recommended that a similar analysis be undertaken for ISO/TS 16281 rating lives, along with further efforts to identify principal root causes of main bearing failures in future work, possibly leading to a new application standard specific to this component. It is also recommended that the impacts of partial wake impingement on main bearing rating lives are investigated.

17 WIND ENERGY↗

Radiation Protection Instrument Reliability and Maintainability Data

This report is a collection of reliability and maintenance data on several types of radiation protection instrumentation. Some radiation detectors are used for personnel safety; others are used for environmental stewardship. Six types of instruments are addressed in this report. These are: continuous air monitors, tritium room air monitors, facility vent stack monitors, tritium bubbler monitors, tritium in effluent water monitors, and general purpose radiation survey meters. Literature searches, operating experience data, and occurrence reports were used to identify failure modes and to estimate quantitative failure rates for several general types of radiation protection instruments. Likewise, data on instrument repair has been found when possible and used to estimate the mean time to repair. These data can be useful for facility safety assessment, personnel safety assessment, environment assessment, and for equipment and labor planning purposes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ductile Tearing of Thin Aluminum Plates Under Blast Loading: Predictions with Fully Coupled Models and Biaxial Material Response Characterization

The work presented in this report concerns the response and failure of thin 2024- T3 aluminum alloy circular plates to a blast load produced by the detonation of a nearby spherical charge. The plates were fully clamped around the circumference and the explosive charge was located centrally with respect to the plate. The principal objective was to conduct a numerical model validation study by comparing the results of predictions to experimental measurements of plate deformation and failure for charges with masses in the vicinity of the threshold between no tearing and tearing of the plates. Stereo digital image correlation data was acquired for all tests to measure the deflection and strains in the plates. The size of the virtual strain gage in the measurements, however, was relatively large, so the strain measurements have to be interpreted accordingly as lower bounds of the actual strains in the plate and of the severity of the strain gradients. A fully coupled interaction model between the blast and the deflection of the structure was considered. The results of the validation exercise indicated that the model predicted the deflection of the plates reasonably accurately as well as the distribution of strain on the plate. The estimation of the threshold charge based on a critical value of equivalent plastic strain measured in a bulge test, however, was not accurate. This in spite of efforts to determine the failure strain of the aluminum sheet under biaxial stress conditions. Further work is needed to be able to predict plate tearing with some degree of confidence. Given the current technology, at least one test under the actual blast conditions where the plate tears is needed to calibrate the value of equivalent plastic strain when failure occurs in the numerical model. Once that has been determined, the question of the explosive mass value at the threshold could be addressed with more confidence.

36 MATERIALS SCIENCE↗