At least 451 records · Page 25

Fault-Tolerant Heat Exchanger

A compact, lightweight heat exchanger has been designed to be fault-tolerant in the sense that a single-point leak would not cause mixing of heat-transfer fluids. This particular heat exchanger is intended to be part of the temperature-regulation system for habitable modules of the International Space Station and to function with water and ammonia as the heat-transfer fluids. The basic fault-tolerant design is adaptable to other heat-transfer fluids and heat exchangers for applications in which mixing of heat-transfer fluids would pose toxic, explosive, or other hazards: Examples could include fuel/air heat exchangers for thermal management on aircraft, process heat exchangers in the cryogenic industry, and heat exchangers used in chemical processing. The reason this heat exchanger can tolerate a single-point leak is that the heat-transfer fluids are everywhere separated by a vented volume and at least two seals. The combination of fault tolerance, compactness, and light weight is implemented in a unique heat-exchanger core configuration: Each fluid passage is entirely surrounded by a vented region bridged by solid structures through which heat is conducted between the fluids. Precise, proprietary fabrication techniques make it possible to manufacture the vented regions and heat-conducting structures with very small dimensions to obtain a very large coefficient of heat transfer between the two fluids. A large heat-transfer coefficient favors compact design by making it possible to use a relatively small core for a given heat-transfer rate. Calculations and experiments have shown that in most respects, the fault-tolerant heat exchanger can be expected to equal or exceed the performance of the non-fault-tolerant heat exchanger that it is intended to supplant (see table). The only significant disadvantages are a slight weight penalty and a small decrease in the mass-specific heat transfer.

Izenson, Michael G.↗

Ventilation Heat Exchanger / Flow Meter for xPLSS

The flow meter / heat exchanger (FMHX) in the ventilation loop of the exploration EMU cools the ventilation gas and measures the ventilation flow rate. The heat exchanger transfers heat from the ventilation gas to the thermal control loop via a miniature shell-and-tube heat exchanger. The flow meters calculate the flow rate of gas through the ventilation loop based on the pressure drop across the heat exchanger core. Creare has delivered four design validation test (DVT) heat exchangers and five DVT flow meters to NASA JSC to support development of the exploration portable life support system (xPLSS). This paper describes the design and performance of the DVT units.The heat exchangers are designed to cool the ventilation gas to a specified temperature with low pressure losses under the most challenging operating conditions. The measured performance of the DVT heat exchangers agrees well with design models and meets all performance requirements. The flow meters use a MEMS thermal flow sensor to produce a signal that is proportional to a small bypass flow around the heat exchanger core. They are designed to achieve high measurement accuracy across the full range of xPLSS operating conditions. We calibrated the flow meters in a special-purpose flow facility that simulates operation in the xPLSS ventilation loop. Calibration testing shows that DVT flow meters produce digital output for vent loop mass flow that meets NASA’s accuracy requirements across the range of xPLSS operating conditions. This paper reviews the design of the heat exchangers and flow meters and presents data from the final flow meter calibration testing, heat exchanger performance validation, and initial ground testing in NASA’s xPLSS.

spacesuit↗

Ventilation Heat Exchanger / Flow Meter for xPLSS

The flow meter / heat exchanger (FMHX) in the ventilation loop of the exploration EMU cools the ventilation gas and measures the ventilation flow rate. The heat exchanger transfers heat from the ventilation gas to the thermal control loop via a miniature shell-and-tube heat exchanger. The flow meters calculate the flow rate of gas through the ventilation loop based on the pressure drop across the heat exchanger core. Creare has delivered four design validation test (DVT) heat exchangers and five DVT flow meters to NASA JSC to support development of the exploration portable life support system (xPLSS). This paper describes the design and performance of the DVT units.The heat exchangers are designed to cool the ventilation gas to a specified temperature with low pressure losses under the most challenging operating conditions. The measured performance of the DVT heat exchangers agrees well with design models and meets all performance requirements. The flow meters use a MEMS thermal flow sensor to produce a signal that is proportional to a small bypass flow around the heat exchanger core. They are designed to achieve high measurement accuracy across the full range of xPLSS operating conditions. We calibrated the flow meters in a special-purpose flow facility that simulates operation in the xPLSS ventilation loop. Calibration testing shows that DVT flow meters produce digital output for vent loop mass flow that meets NASA’s accuracy requirements across the range of xPLSS operating conditions. This paper reviews the design of the heat exchangers and flow meters and presents data from the final flow meter calibration testing, heat exchanger performance validation, and initial ground testing in NASA’s xPLSS.

spacesuit↗

Method for separating components using solids producing multi-stage direct and indirect-contact exchange

A process for forming a solid product or products is disclosed. The process is provided with n desublimating exchangers. An exchanger E1 being associated with a first exchanger and an exchanger En being associated with an nth exchanger, n representing the number of exchangers. The n exchangers comprise at least one direct-contact exchanger comprising a contact fluid. A process fluid is passed through the n exchangers in order from E1 through En. The process fluid comprises a product component or components. The solid product or products form from the product component or components in the plurality of exchangers by desublimation. The solid product or products are separated from the process fluid. In this manner, a solid product or products is formed.

36 MATERIALS SCIENCE↗

Experimental investigation of plastic finned-tube heat exchangers, with emphasis on material thermal conductivity

In this paper, two modified types of polypropylene (PP) with high thermal conductivity up to 2.3 W/m K and 16.5 W/m K are used to manufacture the finned-tube heat exchangers, which are prospected to be used in liquid desiccant air conditioning, heat recovery, water source heat pump, sea water desalination, etc. A third plastic heat exchanger is also manufactured with ordinary PP for validation and comparison. Experiments are carried out to determine the thermal performance of the plastic heat exchangers. It is found that the plastic finned-tube heat exchanger with thermal conductivity of 16.5 W/m K can achieve overall heat transfer coefficient of 34 W/m{sup 2} K. The experimental results are compared with calculation and they agree well with each other. Finally, the effect of material thermal conductivity on heat exchanger thermal performance is studied in detail. The results show that there is a threshold value of material thermal conductivity. Below this value improving thermal conductivity can considerably improve the heat exchanger performance while over this value improving thermal conductivity contributes very little to performance enhancement. For the finned-tube heat exchanger designed in this paper, when the plastic thermal conductivity can reach over 15 W/m K, it can achieve more than 95% of the titanium heat exchanger performance and 84% of the aluminum or copper heat exchanger performance with the same dimension. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Surface roughness and dimensional evaluation of laser powder bed fusion additively manufactured shell and tube heat exchangers

The growing interest in additively manufactured (AM) heat exchangers drove the need to understand how this construction technique impacts heat exchanger performance. Two primary factors driven by AM that influence heat exchanger performance are surface roughness and geometry. To better understand these parameters, a range of shell and tube heat exchangers constructed using laser powder bed fusion were evaluated. Of those evaluated, the surface roughness throughout a fourteen-tube, zero-baffle heat exchanger was measured using computed tomography. Between the inner and outer tubes, the inner tube surfaces had a greater surface roughness than the outer by 8.07 μm, while the surfaces at the top of the build volume had higher surface roughness values than the bottom. Dimensionally, the inner tube diameters of this heat exchanger were 0.15% different from the design value, while the outer diameters were within a 0.84 % difference. Manual measurements across seven other heat exchangers yielded a maximum 1.15% difference between the design and measured diameters. Across the build volume for all heat exchangers studied, the tube diameters at the top were larger than at the bottom by a maximum of 1.24% difference. Inconsistent melting throughout the individual parts and the build volume, as well as particle splatter and thermal gradient variation were attributed to the surface roughness and dimensional changes seen. These results strengthen the knowledge of dimensional and surface roughness considerations when designing AM heat exchangers.

36 MATERIALS SCIENCE↗

Heat Exchanger Design Options and Tritium Transport Study for the VHTR System

This report presents the results of a study conducted to consider heat exchanger options and tritium transport in a very high temperature reactor (VHTR) system for the Next Generation Nuclear Plant Project. The heat exchanger options include types, arrangements, channel patterns in printed circuit heat exchangers (PCHE), coolant flow direction, and pipe configuration in shell-and-tube designs. Study considerations include: three types of heat exchanger designs (PCHE, shell-and-tube, and helical coil); single- and two-stage unit arrangements; counter-current and cross flow configurations; and straight pipes and U-tube designs in shell-and-tube type heat exchangers. Thermal designs and simple stress analyses were performed to estimate the heat exchanger options, and the Finite Element Method was applied for more detailed calculations, especially for PCHE designs. Results of the options study show that the PCHE design has the smallest volume and heat transfer area, resulting in the least tritium permeation and greatest cost savings. It is theoretically the most reliable mechanically, leading to a longer lifetime. The two-stage heat exchanger arrangement appears to be safer and more cost effective. The recommended separation temperature between first and second stages in a serial configuration is 800oC, at which the high temperature unit is about one-half the size of the total heat exchanger core volume. Based on simplified stress analyses, the high temperature unit will need to be replaced two or three times during the plant’s lifetime. Stress analysis results recommend the off-set channel pattern configuration for the PCHE because stress reduction was estimated at up to 50% in this configuration, resulting in a longer lifetime. The tritium transport study resulted in the development of a tritium behavior analysis code using the MATLAB Simulink code. In parallel, the THYTAN code, previously performed by Ohashi and Sherman (2007) on the Peach Bottom data, was revived and verified. The 600 MWt VHTR core input file developed in preparation for the transient tritium analysis of VHTR systems was replaced with the original steady-state inputs for future calculations. A Finite Element Method analysis was performed using COMSOL Multiphysics software to accurately predict tritium permeation through the PCHE type heat exchanger walls. This effort was able to estimate the effective thickness for tritium permeations and develop a correlation for general channel configurations, which found the effective thickness to be much shorter than the average channel distance because of dead spots on the channel side.

99 GENERAL AND MISCELLANEOUS↗

Thermodynamic and kinetic characterization of H-D exchange in Pd and Pd alloys.

A Sieverts apparatus coupled with an RGA is an effective method to detect composition variations during isotopic exchange. This experimental setup provides a powerful tool for the thermodynamic and kinetic characterization of H-D isotope exchange on metals and alloys. H-D exchange behavior during absorption and desorption in the plateau region in Pd have been investigated and reported here. It was found that in the plateau region of H-D-Pd system the equilibrium pressures are between those of H2-Pd and D2-Pd for both absorption and desorption and the equilibrium pressures are higher when the fractions of D in the Pd are higher. Adding a dose of gas H2 (or D2) to Pd-D (or Pd-H) system results in releasing of gas D2 and HD (or H2 and HD) in {beta}-phase of Pd-D (or {beta}-phase of Pd-H), but this does not happen in the plateau region. The equilibrium constants have been determined during exchange and it was found that they agree well with the calculated values reported in literature. The separation factor {alpha} values during exchange have been measured and compared with the literature values. The exchange rates have been determined from the exchange profiles and a first order kinetic model for the exchange of H-D-Pd systems has been employed for the analysis. The exchange activation energies for both directions, H2+PdD and D2+PdH, have been determined.

36 MATERIALS SCIENCE↗

Origin of Ferromagnetic Exchange Coupling in Donor–Acceptor Biradical Analogues of Charge-Separated Excited States

A new donor–acceptor biradical complex, Tp Cum,Me Zn(SQ-VD) (Tp Cum,Me Zn + = zinc(II) hydro-tris(3-cumenyl-5-methylpyrazolyl)borate complex cation; SQ = orthosemiquinone; VD = oxoverdazyl), which is a ground-state analogue of a charge-separated excited state, has been synthesized and structurally characterized. Here, the magnetic exchange interaction between the S = 1/2 SQ and the S = 1/2 VD within the SQ-VD biradical ligand is observed to be ferromagnetic, with $J_{SQ-VD}$ = +77 cm –1 (H = -2$J_{SQ-VD}\bar{S}_{SQ}·\bar{S}_{VD}$) determined from an analysis of the variable-temperature magnetic susceptibility data. The pairwise biradical exchange interaction in Tp Cum,Me Zn(SQ-VD) can be compared with that of the related donor–acceptor biradical complex Tp Cum,Me Zn(SQ-NN) (NN = nitronyl nitroxide, S = 1/2), where $J_{SQ-NN}$ ≅ +550 cm –1 . This represents a dramatic reduction in the biradical exchange by a factor of ~7, despite the isolobal nature of the VD and NN acceptor radical SOMOs. Computations assessing the magnitude of the exchange were performed using a broken-symmetry density functional theory (DFT) approach. These computations are in good agreement with those computed at the CASSCF NEVPT2 level, which also reveals an S = 1 triplet ground state as observed in the magnetic susceptibility measurements. A combination of electronic absorption spectroscopy and CASSCF computations has been used to elucidate the electronic origin of the large difference in the magnitude of the biradical exchange coupling between Tp Cum,Me Zn(SQ-VD) and Tp Cum,Me Zn(SQ-NN). A Valence Bond Configuration Interaction (VBCI) model was previously employed to highlight the importance of mixing an SQ SOMO → NNLUMO charge transfer configuration into the electronic ground state to facilitate the stabilization of the high-spin triplet (S = 1) ground state in Tp Cum,Me Zn(SQ-NN). Here, CASSCF computations confirm the importance of mixing the pendant radical (e.g., VD, NN) LUMO (VD LUMO and NN LUMO ) with the SOMO of the SQ radical (SQ SOMO ) for stabilizing the triplet, in addition to spin polarization and charge transfer contributions to the exchange. An important electronic structure difference between Tp Cum,Me Zn(SQ-VD) and Tp Cum,Me Zn(SQ-NN), which leads to their different exchange couplings, is the reduced admixture of excited states that promote ferromagnetic exchange into the Tp Cum,Me Zn(SQ-VD) ground state, and the intrinsically weaker mixing between the VD LUMO and the SQ SOMO compared to that observed for Tp Cum,Me Zn(SQ-NN), where this orbital mixing is significant. The results of this comparative study contribute to a greater understanding of biradical exchange interactions, which are important to our understanding of excited-state singlet–triplet energy gaps, electron delocalization, and the generation of electron spin polarization in both the ground and excited states of (bpy)Pt(CAT-radical) complexes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Comparative Evaluation and Selection of High-Temperature Heat Exchangers for Application to Integrated Energy Systems

The following report aims to create a refined and well-structured method for comparatively evaluating heat exchanger technologies for integrated energy systems that caters customers’ specific needs while meeting engineering requirements. For the evaluation, this study elevates previous evaluation metrics, enhances the knowledge base via literature and market surveys, and identifies the figures of merit with robust rationales to enhance the quality of decisions made throughout the proposed heat exchanger evaluation process. The heat exchanger designs evaluated as part of the case study are shell and tube heat exchangers, printed circuit heat exchangers, plate heat exchangers, spiral heat exchangers, and heat pipe heat exchangers. The information presented in this report is meant for industries interested in making a preliminary screening process to identify the most suitable heat exchanger design for their application of interest.

42 ENGINEERING↗

High performance heat exchangers for next generation hybrid cooler (CRADA NFE-19-07891 Final Report)

The evaporative cooling process has been successfully deployed in multiple energy conversion processes such as power generation, process cooling, heating, ventilation & cooling (HVAC), and commercial and industrial refrigeration. The heat exchanger is a very common yet extremely critical component of such systems. The device is important since the performance of the overall cooling system heavily relies on the thermal-hydraulic efficiency of the heat exchanger. The possible wet operation as evaporative cooling heat exchanger complicates the issue. Indeed, based on the hybrid nature of operation (fully dry, partially wet, fully wet) the efficiency can vary significantly and can cause performance variation for the whole system. Understanding the importance of the issue, Oak Ridge National Laboratory (Contractor) and Baltimore Aircoil Company (Participant) propose an activity focused on the analysis of the existing heat exchanger technology used in air and evaporative cooling processes and design, development and demonstration of a novel heat exchanger design based on porous materials. The potential candidates include metallic wire meshes and metal foams carefully designed for the proposed application. Prior research has indicated that these materials have great potential for deployment in thermal systems, particularly heat sinks and heat exchangers. It is expected that the successful completion of the project will lead to novel heat exchanger technology for hybrid systems (capable of dry and wet operation) by exploring newly emerging materials and their potential for heat transfer application. The overall goal is to develop a next generation heat exchanger technology which can be deployed in evaporative cooling systems. The impact of the such development is significant since, it will not only make the overall system highly efficient but will also, reduce the total refrigerant charge in the heat exchanger, a critical aspect for the deployment of refrigerants with lower Global Warming Potential (GWP).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Comparative Evaluation and Selection of High-Temperature Heat Exchangers for Application to Integrated Energy Systems

The following report aims to create a refined and well-structured method for comparatively evaluating heat exchanger technologies for integrated energy systems that caters customers’ specific needs while meeting engineering requirements. For the evaluation, this study elevates previous evaluation metrics, enhances the knowledge base via literature and market surveys, and identifies the figures of merit with robust rationales to enhance the quality of decisions made throughout the proposed heat exchanger evaluation process. The heat exchanger designs evaluated as part of the case study are shell and tube heat exchangers, printed circuit heat exchangers, plate heat exchangers, spiral heat exchangers, and heat pipe heat exchangers. The information presented in this report is meant for industries interested in making a preliminary screening process to identify the most suitable heat exchanger design for their application of interest.

42 - ENGINEERING↗

NGNP/HTE full-power operation at reduced high-temperature heat exchanger temperatures.

Operation of the Next Generation Nuclear Plant (NGNP) with reduced reactor outlet temperature at full power was investigated for the High Temperature Electrolysis (HTE) hydrogen-production application. The foremost challenge for operation at design temperature is achieving an acceptably long service life for heat exchangers. In both the Intermediate Heat Exchanger (IHX) and the Process Heat Exchanger (PHX) (referred to collectively as high temperature heat exchangers) a pressure differential of several MPa exists with temperatures at or above 850 C. Thermal creep of the heat exchanger channel wall may severely limit heat exchanger life depending on the alloy selected. This report investigates plant performance with IHX temperatures reduced by lowering reactor outlet temperature. The objective is to lower the temperature in heat transfer channels to the point where existing materials can meet the 40 year lifetime needed for this component. A conservative estimate for this temperature is believed to be about 700 C. The reactor outlet temperature was reduced from 850 C to 700 C while maintaining reactor power at 600 MWt and high pressure compressor outlet at 7 MPa. We included a previously reported design option for reducing temperature at the PHX. Heat exchanger lengths were adjusted to reflect the change in performance resulting from coolant property changes and from resizing related to operating-point change. Turbomachine parameters were also optimized for the new operating condition. An integrated optimization of the complete system including heat transfer equipment was not performed. It is estimated, however, that by performing a pinch analysis the combined plant efficiency can be increased from 35.5 percent obtained in this report to a value between 38.5 and 40.1 percent. Then after normalizing for a more than three percent decrease in commodities inventory compared to the reference plant, the commodities-normalized efficiency lies between 40.0 and 41.3. This compares with a value of 43.9 for the reference plant. This latter plant has a reactor outlet temperature of 850 C and the two high temperature heat exchangers. The reduction in reactor outlet temperature from 850 C to 700 C reduces the tritium permeability rate in the IHX metal by a factor of three and thermal creep by five orders of magnitude. The design option for reducing PHX temperature from 800 C to 200 C reduces the permeability there by three orders of magnitude. In that design option this heat exchanger is the single 'choke-point' for tritium migration from the nuclear to the chemical plant.

08 HYDROGEN↗

Development of Polymer Waste Form for Spent Ion-Exchange Resins

A large amount of radioactive waste streams has been treated by ion-exchange resins at most of nuclear facilities for many years. These activities leave radionuclides as well as chemical contaminants on the spent resins, and the spent resins are considered as low- and intermediate-level radioactive waste. Spent ion-exchange resins require special immobilization treatment to meet the waste acceptance criteria for disposal. Immobilization of spent ion-exchange resins can be processed by mixing or incorporating them with suitable solidifying materials, such as cement, bitumen, organic polymers, and other materials or a combination of them. The selection of immobilization options for spent ion-exchange resins must consider their physical, chemical, and radiological characteristics. In this study, direct immobilization method was used to solidify the spent ion-exchange resins using organic polymer for improving the waste content. The objective of this study is to test the immobilization of spent ion-exchange resins using polymer waste form and enhance the solidified waste content. The specific objective of this study was to develop polymer waste form to solidify spent ion-exchange resins. Leaching (ANSI/ANS 16.1) and compressive strength tests were performed to meet the acceptance criteria of waste form for disposal. Ion-exchange resin has been solidified physically and chemically stable in the polymer waste form. The leaching test (ANSI/ANS16.1) for two polymer waste form specimens were conducted. The leachability indexes of sample A and B showed to meet the acceptance criteria for disposal. The compressive strength tested showed higher values in polymer waste form prepared with ion exchange resin compared to CoCl{sub 2} polymer form (sample B). Although spent resin was successively solidified in polymer matrix, the future experiment will develop a polymer waste form as a pre-treatment of spent resin for size reduction using a ball milling (500 RPM, 280 min)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Iron Atom Exchange between Hematite and Aqueous Fe(II)

Aqueous Fe(II) has been shown to exchange with structural Fe(III) in goethite without any significant phase transformation. It remains unclear, however, whether aqueous Fe(II) undergoes similar exchange reactions with structural Fe(III) in hematite, a ubiquitous iron oxide mineral. Here, we use an enriched 57 Fe tracer to show that aqueous Fe(II) exchanges with structural Fe(III) in hematite at room temperature, and that the amount of exchange is influenced by particle size, pH, and Fe(II) concentration. Reaction of 80 nm-hematite (27 m 2 g -1 ) with aqueous Fe(II) at pH 7.0 for 30 days results in ~5% of its structural Fe(III) atoms exchanging with Fe(II) in solution, which equates to about one surface iron layer. Smaller, 50 nm-hematite particles (54 m 2 g -1 ) undergo about 25% exchange (~3× surface iron) with aqueous Fe(II), demonstrating that structural Fe(III) in hematite is accessible to the fluid in the presence of Fe(II). The extent of exchange in hematite increases with pH up to 7.5 and then begins to decrease as the pH progresses to 8.0, likely due to surface site saturation by sorbed Fe(II). Similarly, when we vary the initial amount of added Fe(II), we observe decreasing amounts of exchange when aqueous Fe(II) is increased beyond surface saturation. In conclusion, this work shows that Fe(II) can catalyze iron atom exchange between bulk hematite and aqueous Fe(II), despite hematite being the most thermodynamically stable iron oxide.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cavitation Enables Switchable and Rapid Block Polymer Exchange under High-χ N Conditions

Kinetically trapped micelles are a novel platform for diverse emerging applications. However, their homogenization and reproducibility is inherently challenging due to the high-χN barrier toward chain exchange processes. Sonication enables switchable micelle exchange where cavitation leads to exchange and cessation returns micelles to kinetic entrapment. The mechanism was posited to be an agitation induced exchange process similar to recent developments with vortexing. This study reports the first SANS measurements of chain exchange during cavitation induced exchange (CIE). The mixed chain concentration progresses linearly with sonication time, analogous to vortexing. In contrast, the rate of CIE was directly proportional to the polymer concentration. This feature indicates that CIE uniquely overcomes the energetic barriers that reduce exchange rates with other methods. Furthermore, the linear progression with time and direct concentration dependence suggest that exchange is limited by the rate of micelle–bubble interactions. Here, CIE thus supports switchable entrapment with rapid exchange rates, supporting ongoing developments with kinetically controlled micelles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

From Bulk to Interface: Solvent Exchange Dynamics and Their Role in Ion Transport and the Interfacial Model of Rechargeable Magnesium Batteries

Multivalent battery chemistries have been explored in response to the increasing demand for high-energy rechargeable batteries utilizing sustainable resources. Solvation structures of working cations have been recognized as a key component in the design of electrolytes; however, most structure–property correlations of metal ions in organic electrolytes usually build upon favorable static solvation structures, often overlooking solvent exchange dynamics. We here report the ion solvation structures and solvent exchange rates of magnesium electrolytes in various solvents by using multimodal nuclear magnetic resonance (NMR) analysis and molecular dynamics/density functional theory (MD/DFT) calculations. These magnesium solvation structures and solvent exchange dynamics are correlated to the combined effects of several physicochemical properties of the solvents. Moreover, Mg 2+ transport and interfacial charge transfer efficiency are found to be closely correlated to the solvent exchange rate in the binary electrolytes where the solvent exchange is tunable by the fraction of diluent solvents. Our primary findings are (1) most battery-related solvents undergo ultraslow solvent exchange coordinating to Mg 2+ (with time scales ranging from 0.5 μs to 5 ms), (2) the cation transport mechanism is a mixture of vehicular and structural diffusion even at the ultraslow exchange limit (with faster solvent exchange leading to faster cation transport), and (3) an interfacial model wherein organic-rich regions facilitate desolvation and inorganic regions promote Mg 2+ transport is consistent with our NMR, electrochemistry, and cryogenic X-ray photoelectron spectroscopy (cryo-XPS) results. In conclusion, this observed ultraslow solvent exchange and its importance for ion transport and interfacial properties necessitate the judicious selection of solvents and informed design of electrolyte blends for multivalent electrolytes.

25 ENERGY STORAGE↗

Intrinsic exchange biased anomalous Hall effect in an uncompensated antiferromagnet MnBi 2 Te 4

Achieving spin-pinning at the interface of hetero-bilayer ferromagnet/antiferromagnet structures in conventional exchange bias systems can be challenging due to difficulties in interface control and the weakening of spin-pinning caused by poor interface quality. In this work, we propose an alternative approach to stabilize the exchange interaction at the interface of an uncompensated antiferromagnet by utilizing a gradient of interlayer exchange coupling. We demonstrate this exchange interaction through a designed field training protocol in the odd-layer topological antiferromagnet MnBi 2 Te 4 . Our results reveal a remarkable field-trained exchange bias of up to ~ 400 mT, which exhibits high repeatability and can be easily reset by a large training field. Notably, this field-trained exchange bias effect persists even with zero-field initialization, presenting a stark contrast to the traditional field-cooled exchange bias. The highly tunable exchange bias observed in this single antiferromagnet compound, without the need for an additional magnetic layer, provides valuable insight into the exchange interaction mechanism. These findings pave the way for the systematic design of topological antiferromagnetic spintronics.

36 MATERIALS SCIENCE↗