Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Galileo Institute for Astronomy (IFA) charge-coupled device (CCD) system

A fully portable self-contained charge-coupled device system has been constructed for shared use with the Galileo Project Imaging Team. The detector currently incorporated in the system is a Texas Instruments 500 x 500 three-phase CCD that has been thinned to operate in the backside illuminated mode. The detector and camera mainframe electronics were provided by the Jet Propulsion Laboratory. The support electronics and control interfaces necessary to operate the mainframe were constructed. The data system, which is built around a DeAnza Visacom VC-5000 Image Processor with an imbedded LSI-11 minicomputer, was also integrated. The capability to do image processing in real-time at the telescope has proved to be extremely valuable. The overall system read noise has been measured at 25 electrons. Full-well capacity is 40,000 electrons. Some results from laboratory tests and initial observing runs at the Mauna Kea 2.2-m telescope are presented.

Hlivak, R. J.↗

Noise Temperature and IF Bandwidth of a 530 GHz Heterodyne Receiver Employing a Diffusion-Cooled Superconducting Hot-Electron Mixer

We report on the first heterodyne measurements with a diffusion-cooled hot-electron bolometer mixer in the submillimeter wave band, using a waveguide mixer cooled to 2.2 K. The best receiver noise temperature at a local oscillator frequency of 533 GHz and an intermediate frequency of 1.4 GHz was 650 K (double sideband). The 3 dB IF roll-off frequency was around 1.7 to 1.9 GHz, with a weak dependence on the device bias conditions.

Skalare, A.↗

Interference patterns in the Spacelab 2 plasma wave data - Oblique electrostatic waves generated by the electron beam

During the Spacelab 2 mission the University of Iowa's Plasma Diagnostics Package (PDP) explored the plasma environment around the shuttle. Wideband spectrograms of plasma waves were obtained from the PDP at frequencies of 0-30 kHz and at distances up to 400 m from the shuttle. Strong low-frequency (below 10 kHz) electric field noise was observed in the wideband data during two periods in which an electron beam was ejected from the shuttle. This noise shows clear evidence of interference patterns caused by the finite (3.89 m) antenna length. The low-frequency noise was the most dominant type of noise produced by the ejected electron beam. Analysis of antenna interference patterns generated by these waves permits a determination of the wavelength, the direction of propagation, and the location of the source region. The observed waves have a linear dispersion relation very similar to that of ion acoustic waves. The waves are believed to be oblique ion acoustic or high-order ion cyclotron waves generated by a current of ambient electrons returning to the shuttle in response to the ejected electron beam.

Feng, Wei↗

Signal Processing in SBND with Calibrated and Validated Electronics and Field Responses

SBND is a liquid argon time projection chamber in Fermilab’s Short-Baseline Neutrino Program, located 110 m from the neutrino source and operating in a high-rate environment with unprecedented statistics. Charged particles from neutrino interactions ionize the argon, and the resulting electrons drift to the anode wires, inducing current signals recorded as raw waveforms. These waveforms are a convolution of deposited charge with the electronics and TPC field responses, making accurate signal processing essential for recovering the true charge distribution. Signal processing forms the starting point for SBND reconstruction, directly impacting hit finding, charge calibration, clustering, and the reconstruction of tracks and showers, and therefore playing a key role in energy reconstruction and particle identification. In this poster, we present an overview of the SBND signal processing chain, including noise removal, channel-by-channel electronics correction, signal identification, and deconvolution using measured electronics and TPC field responses. We demonstrate that the two kernel functions—electronics and field responses—achieve high precision when compared to data, ensuring that the SBND signal processing chain provides a robust and accurate foundation for event reconstruction and precision physics measurements.

Singh, Prabhjot [Louisiana State U.] (ORCID:000000↗

Unsupervised anomaly detection in MeV ultrafast electron diffraction

MeV ultrafast electron diffraction (MUED) is a pump-probe technique used to study the dynamic structural evolution of materials. An ultrashort laser pulse triggers structural changes, which are then probed by an ultrashort relativistic electron beam. To overcome low signal-to-noise ratios, diffraction patterns are averaged over thousands of shots. However, shot-to-shot instabilities in the electron beam can distort individual patterns, introducing uncertainty. Improving MUED accuracy requires detecting and removing these anomalous patterns from large datasets. In this work, we developed a fully unsupervised methodology for the detection of anomalous diffraction patterns. Using a convolutional autoencoder, we calculate the reconstruction mean squared error of the diffraction patterns. Based on the statistical analysis of this error, we provide the user an estimation of the probability that the pattern is normal, which also allows a posterior visual inspection of the images that are difficult to classify. This method has been trained with only 100 diffraction patterns and tested on 1521 patterns, resulting in a false positive rate between 0.2% and 0.4%, with a training time of 10 s per image and a test time of about 1 s per image. Here, the proposed methodology can also be applied to other diffraction techniques in which large datasets are collected that include faulty images due to instrumental instabilities.

43 PARTICLE ACCELERATORS↗

Room temperature depinning of the charge-density waves in quasi-two-dimensional 1T-TaS 2 devices

Here we report on the depinning of nearly commensurate charge-density waves in 1T-TaS 2 thin films at room temperature. A combination of the differential current–voltage measurements with the low-frequency noise spectroscopy provides unambiguous means for detecting the depinning threshold field in quasi-2D materials. The depinning process in 1T-TaS 2 is not accompanied by an observable abrupt increase in electric current—in striking contrast to depinning in the conventional charge-density-wave materials with quasi-1D crystal structure. We explained it by the fact that the current density from the charge-density waves in the 1T-TaS 2 devices is orders of magnitude smaller than the current density of the free carriers available in the discommensuration network surrounding the commensurate charge-density wave islands. The depinning fields in 1T-TaS 2 thin-film devices are several orders of magnitude larger than those in quasi-1D van der Waals materials. Obtained results are important for the proposed applications of the charge-density wave devices in electronics.

2D materials↗

Electronically Tuned Microwave Oscillator

Features include low phase noise and frequency stability. Bias-tuned, low-phase-noise microwave oscillator circuit based on npn bipolar transistor and dielectric resonator. Operating at frequency of about 8.4 GHz, oscillator adjusted to give low phase noise, relatively flat power output versus frequency, and nearly linear frequency versus bias voltage.

Lakshminarayana, Mysore↗

An analysis of whistler mode radiation from the Spacelab 2 electron beam

During the Spacelab 2 mission the plasma diagnostics package (PDP) was released from the Shuttle to free fly. At times during this free flight, when the PDP was magnetically connected to the Shuttle, Stanford's fast-pulsed electron generator, located in the Shuttle cargo bay, ejected a 1-keV 50-mA electron beam. The PDP plasma-wave instrument detected intense whistler-mode radiation during these beam ejections. This paper presents a study of a whistler mode emission detected during one particular continuous electron beam firing. Calculations indicate that the beam radiated approximately 1.6 mW in the whistler mode as the beam traversed the 200 m from the Shuttle to the PDP. The emissivity also decreased by about a factor of 10 over this same distance. The measured wave powers are 10 to the 7th greater than wave powers expected from incoherent Cerenkov radiation, verifying that the radiation is generated by a coherent process. Estimates of the emissivity based on measured electric field intensities in the beam indicate that the whistler-mode noise is produced by radiation from electron bunches created by an electrostatic beam-plasma instability.

Farrell, W. M.↗

SAMPA Based Streaming Readout Data Acquisition Prototype

We have assembled a small-scale streaming data acquisition system based on the SAMPA front-end ASIC. The 32-channel SAMPA chip was designed for the high-luminosity upgrade of the ALICE Time Projection Chamber (TPC) detector at the CERN Large Hadron Collider. The goals of the prototype system are to determine if the SAMPA chip is appropriate for use in detector systems at Jefferson Lab, and to gain experience with the hardware and software required to deploy streaming data acquisition systems in nuclear physics experiments. The 800 channel system is composed of components used in the ALICE TPC data acquisition upgrade. Five front-end cards (FEC) support five SAMPA chips each. SAMPA data streams on an FEC are concentrated into two high-speed (4.48 Gb/s) serial data streams by a pair Gigabit Transceiver ASICs (GBTx). These ten streams (44.8 Gb/s) are transmitted from the FECs over fibers to a PCIe based readout unit. The FPGA engine on the readout unit compresses data for transmission to a server via 100 Gb ethernet. Components on the FECs are radiation tolerant. High data rates can be handled. The system is by design scalable and thus provides a functional prototype for high-rate streaming readout at Jefferson Lab and the future Electron Ion Collider. We have made fundamental measurements (noise, linearity, time resolution) on the SAMPA ASIC. We have also coupled the readout system to a small Gas Electron Multiplier (GEM) detector and have studied its response to cosmic rays. A beam test of the system is planned.

ABBOTT, David↗

Frequency-Domain Analysis of Diffusion-Cooled Hot-Electron Bolometer Mixers

A new theoretical model is introduced to describe heterodyne mixer conversion efficiency and noise (from thermal fluctuation effects) in diffusion-cooled superconducting hot-electron bolometers. The model takes into account the non-uniform internal electron temperature distribution generated by Wiedemann-Franz heat conduction, and accepts for input an arbitrary (analytical or experimental) superconducting resistance-versus- temperature curve. A non-linear large-signal solution is solved iteratively to calculate the temperature distribution, and a linear frequency-domain small-signal formulation is used to calculate conversion efficiency and noise. In the small-signal solution the device is discretized into segments, and matrix algebra is used to relate the heating modulation in the segments to temperature and resistance modulations. Matrix expressions are derived that allow single-sideband mixer conversion efficiency and coupled noise power to be directly calculated. The model accounts for self-heating and electrothermal feedback from the surrounding bias circuit.

Skalare, A.↗

Overview of Collaborative Research Between UNICAMP in Brazil and Fermilab in Cryogenics

The Long-Baseline Neutrino Facility (LBNF) situated at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, serves as the host for the Deep Underground Neutrino Experiment (DUNE), employing cryostats with nearly 70,000 metric tons of high purity liquid argon (LAr). The integrity of LAr quality is pivotal in determining the electron lifetime within DUNE, directly impacting its signal-to-noise ratio. Specifically, Far Detector 1 (FD-1) in cryostat 1 requires an electron lifetime over 3 ms within its 3.5 m drift, corresponding to less than 100 parts-per-trillion (ppt) Oxygen equivalent contamination. Far Detector 2 (FD-2) in cryostat 2 demands over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen equivalent contamination. Nitrogen (N2) absorption of LAr scintillation light, known as quenching, necessitates N2 contamination in LAr to remain below 1 ppm to minimize photon loss and enhance energy reconstruction. Studies indicate that at 1 ppm N2, approximately 20% of scintillation light is lost, highlighting the importance of minimizing N2 contamination. Brazil State University of Campinas's (UNICAMP) contribution to LBNF focuses on developing argon purification and regeneration for DUNE FD-1 and FD-2. To that effect, they constructed a test facility to perform studies on LAr purification at a smaller scale, the Purification Liquid Argon Cryostat (PuLArC) with approximately 90 liters of LAr. One of the filtration materials was considered and tested Li-FAU molecular sieve. Value engineering on argon purification media was conducted, leading to the identification of Li-FAU zeolite's ability to effectively capture N2 impurities during LAr circulation. Testing at UNICAMP's PuLArC facility demonstrated that 1 kg of Li-FAU is capable of reducing N2 contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours of circulation. In October 2023, testing at the Iceberg cryostat in Fermilab's Noble Liquid Test Facility (NLTF), with approximately 2,625 liters of LAr, confirmed the efficacy of 3 kg of Li-FAU in reducing N2 contamination from ~ 5 ppm of injected N2 down to less than 1 ppm over 96-hour cycles, showcasing its potential for larger-scale LAr cryostats. Further tests are planned to validate Li-FAU's use as a possible alternative to Molecular Sieve 4A in LBNF-DUNE and related liquid argon experiments. This contribution will describe how the research was performed and present the test setups and results in detail. This advancement not only has the potential to enhance DUNE's precision but also to elevate liquid argon experiments globally, showcasing the power of international scientific collaboration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overview of collaborative research between UNICAMP in Brazil and Fermilab in cryogenics

The Long-Baseline Neutrino Facility (LBNF) situated at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, serves as the host for the Deep Underground Neutrino Experiment (DUNE), employing cryostats with nearly 70,000 metric tons of high purity liquid argon (LAr). The integrity of LAr quality is pivotal in determining the electron lifetime within DUNE, directly impacting its signal-to-noise ratio. Specifically, Far Detector 1 (FD-1) in cryostat 1 requires an electron lifetime over 3 ms within its 3.5 m drift, corresponding to less than 100 parts-per-trillion (ppt) Oxygen equivalent contamination. Far Detector 2 (FD-2) in cryostat 2 demands over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen equivalent contamination. Nitrogen (N$_2$) absorption of LAr scintillation light, known as quenching, necessitates N$_2$ contamination in LAr to remain below 1 ppm to minimize photon loss and enhance energy reconstruction. Studies indicate that at 1 ppm N$_2$, approximately 20% of scintillation light is lost, highlighting the importance of minimizing N$_2$ contamination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved noise performance from the next-generation buried-channel p-MOSFET SiSeROs

The Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. In our earlier work, we characterized a number of first prototype SiSeROs with the MOSFET transistor channels at the surface layer. An equivalent noise charge (ENC) of around 15 electrons root mean square (RMS) was obtained. In this work, we examine the first buried-channel SiSeRO. Here we have achieved substantially improved noise performance of around 4.5 electrons root mean square (RMS) and a full width half maximum (FWHM) energy resolution of 132 eV at 5.9 keV, for a readout speed of 625 kpixel/s. We also discuss how digital filtering techniques can be used to further improve the SiSeRO noise performance. Additional measurements and device simulations will be essential to further mature the SiSeRO technology. This new device class presents an exciting new technology for the next-generation astronomical X-ray telescopes requiring fast, low-noise, radiation-hard megapixel imagers with moderate spectroscopic resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Miniaturization in x ray and gamma ray spectroscopy

The paper presents advances in two new sensor technologies and a miniaturized associated electronics technology which, when combined, can allow for very significant miniaturization and for the reduction of weight and power consumption in x-ray and gamma-ray spectroscopy systems: (1) Mercuric iodide (HgI2) x-ray technology, which allows for the first time the construction of truly portable, high-energy resolution, non-cryogenic x-ray fluorescence (XRF) elemental analyzer systems, with parameters approaching those of laboratory quality cryogenic instruments; (2) the silicon avalanche photodiode (APD), which is a solid-state light sensitive device with internal amplification, capable of uniquely replacing the vacuum photomultiplier tube in scintillation gamma-ray spectrometer applications, and offering substantial improvements in size, ruggedness, low power operation and energy resolution; and (3) miniaturized (hybridized) low noise, low power amplification and processing electronics, which take full advantage of the favorable properties of these new sensors and allow for the design and fabrication of advanced, highly miniaturized x-ray and gamma-ray spectroscopy systems. The paper also presents experimental results and examples of spectrometric systems currently under construction. The directions for future developments are discussed.

Iwanczyk, Jan S.↗

Electronic photography at NASA Langley Research Center

The field of photography began a metamorphosis several years ago which promises to fundamentally change how images are captured, transmitted, and output. At this time the metamorphosis is still in the early stages, but already new processes, hardware, and software are allowing many individuals and organizations to explore the entry of imaging into the information revolution. Exploration at this time is prerequisite to leading expertise in the future, and a number of branches at LaRC have ventured into electronic and digital imaging. Their progress until recently has been limited by two factors: the lack of an integrated approach and the lack of an electronic photographic capability. The purpose of the research conducted was to address these two items. In some respects, the lack of electronic photographs has prevented application of an integrated imaging approach. Since everything could not be electronic, the tendency was to work with hard copy. Over the summer, the Photographics Section has set up an Electronic Photography Laboratory. This laboratory now has the capability to scan film images, process the images, and output the images in a variety of forms. Future plans also include electronic capture capability. The current forms of image processing available include sharpening, noise reduction, dust removal, tone correction, color balancing, image editing, cropping, electronic separations, and halftoning. Output choices include customer specified electronic file formats which can be output on magnetic or optical disks or over the network, 4400 line photographic quality prints and transparencies to 8.5 by 11 inches, and 8000 line film negatives and transparencies to 4 by 5 inches. The problem of integrated imaging involves a number of branches at LaRC including Visual Imaging, Research Printing and Publishing, Data Visualization and Animation, Advanced Computing, and various research groups. These units must work together to develop common approaches to image processing and archiving. The ultimate goal is to be able to search for images using an on-line database and image catalog. These images could then be retrieved over the network as needed, along with information on the acquisition and processing prior to storage. For this goal to be realized, a number of standard processing protocols must be developed to allow the classification of images into categories. Standard series of processing algorithms can then be applied to each category (although many of these may be adaptive between images). Since the archived image files would be standardized, it should also be possible to develop standard output processing protocols for a number of output devices. If LaRC continues the research effort begun this summer, it may be one of the first organizations to develop an integrated approach to imaging. As such, it could serve as a model for other organizations in government and the private sector.

Holm, Jack M.↗