Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Recent progress in high-temperature superconducting undulators

Considerable effort has been devoted to the development of superconducting undulators (SCUs) intended for particle accelerator-based light sources, including synchrotrons and free electron laser (FEL) facilities. Recently, a high-temperature superconducting (HTS) undulator prototype, consisting of staggered-array Re-Ba-Cu-O bulks, achieved an on-axis sinusoidal magnetic field profile with a peak amplitude B$_0$ of 2.1 T and a period length of 10 mm, resulting in a deflection parameter K = 1.96. Such a short period HTS undulator not only enables the generation of higher-energy photons, but also supports the construction of economically feasible and compact FELs with shorter linear accelerators (LINACs). This article provides a comprehensive review of recent advances in the staggered-array bulk HTS undulator as well as other types of HTS undulators. Furthermore, it offers insights into the development of engineering HTS undulator prototypes designed for deployment in synchrotron and free electron laser (FEL) facilities. We conclude by discussing opportunities for and the challenges facing the use of HTS undulators in practical applications.

43 PARTICLE ACCELERATORS↗

A localized view on molecular dissociation via electron-ion partial covariance

Inner-shell photoelectron spectroscopy provides an element-specific probe of molecular structure, as core-electron binding energies are sensitive to the chemical environment. Short-wavelength femtosecond light sources, such as Free-Electron Lasers (FELs), even enable time-resolved site-specific investigations of molecular photochemistry. Here, we study the ultraviolet photodissociation of the prototypical chiral molecule 1-iodo-2-methylbutane, probed by extreme-ultraviolet (XUV) pulses from the Free-electron LASer in Hamburg (FLASH) through the ultrafast evolution of the iodine 4d binding energy. Methodologically, we employ electron-ion partial covariance imaging as a technique to isolate otherwise elusive features in a two-dimensional photoelectron spectrum arising from different photofragmentation pathways. The experimental and theoretical results for the time-resolved electron spectra of the 4d 3/2 and 4d 5/2 atomic and molecular levels that are disentangled by this method provide a key step towards studying structural and chemical changes from a specific spectator site.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The cosmic-ray positron excess and its imprint in the Galactic gamma-ray sky

Abstract We study the origin of the positron excess observed in the local cosmic-ray spectrum at high energies, and relate it to the cosmic rays and gamma-ray emission across the entire Galaxy. In particular, we explore the hypothesis of a single, dominant source accountable for primary electron-positron pairs. Since we are agnostic about the physical nature of the underlying source population, we consider four models that are representative of young pulsars, old stars (as a tracer of millisecond pulsars), and annihilating dark matter particles. In the dark matter hypothesis, we consider both a cored and a cuspy model for the halo in the Milky Way. Then, we compare the associated gamma-ray sky maps withFermi-LAT data. We find that the emission arising from pulsar wind nebulae is fairly concentrated near the mid plane, and therefore additional cosmic-ray sources must be invoked to explain the emission at the center of the Galaxy. If the local positron excess were mainly due to millisecond pulsars, inverse Compton scattering by the particles injected would naturally account for a non-negligible fraction of the central gamma-ray emission. The same process would lead to a tension for a standard NFW dark matter profile, exceeding the gamma-ray data by almost a factor of 2 in some regions of the Galaxy. Although the results for an isothermal, cored profile are in agreement with these data, the cross section needed in both cases is around 2 orders of magnitude above the thermal cross-section, disfavouring the dark matter interpretation.

Astronomy & Astrophysics↗

Relativistic plasma physics in supercritical fields

Since the invention of chirped pulse amplification, which was recognized by a Nobel Prize in physics in 2018, there has been a continuing increase in available laser intensity. Combined with advances in our understanding of the kinetics of relativistic plasma, studies of laser-plasma interactions are entering a new regime where the physics of relativistic plasmas is strongly affected by strong-field quantum electrodynamics (QED) processes, including hard photon emission and electron-positron (e⁻-e⁺) pair production. Additionally, this coupling of quantum emission processes and relativistic collective particle dynamics can result in dramatically new plasma physics phenomena, such as the generation of dense e⁻-e⁺ pair plasma from near vacuum, complete laser energy absorption by QED processes, or the stopping of an ultra-relativistic electron beam, which could penetrate a cm of lead, by a hair's breadth of laser light. In addition to being of fundamental interest, it is crucial to study this new regime to understand the next generation of ultra-high intensity laser-matter experiments and their resulting applications, such as high energy ion, electron, positron, and photon sources for fundamental physics studies, medical radiotherapy, and next generation radiography for homeland security and industry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Robust direct laser acceleration of electrons with flying-focus laser pulses

Direct laser acceleration (DLA) offers a compact source of high-charge, energetic electrons for generating secondary radiation or neutrons. While DLA in high-density plasma optimizes the energy transfer from a laser pulse to electrons, it exacerbates nonlinear propagation effects, such as filamentation, that can disrupt the acceleration process. Here, we show that superluminal flying-focus pulses (FFPs) mitigate nonlinear propagation, thereby enhancing the number of high-energy electrons and resulting x-ray yield. Three-dimensional particle-in-cell simulations show that, compared to a Gaussian pulse of equal energy (1 J) and intensity (2 × 10 20 W/cm 2 ), an FFP produces 80 × more electrons above 100 MeV, increases the electron cutoff energy by 20%, triples the high-energy x-ray yield, and improves x-ray collimation. These results illustrate the ability of spatiotemporally structured laser pulses to provide additional control in the highly nonlinear, relativistic regime of laser-plasma interactions.

Laser-produced plasmas↗

EUV and Hard X-ray Hartmann Wavefront Sensing for Optical Metrology, Alignment and Phase Imaging

For more than 15 years, Imagine Optic have developed Extreme Ultra Violet (EUV) and X-ray Hartmann wavefront sensors for metrology and imaging applications. These sensors are compatible with a wide range of X-ray sources: from synchrotrons, Free Electron Lasers, laser-driven betatron and plasma-based EUV lasers to High Harmonic Generation. In this paper, we first describe the principle of a Hartmann sensor and give some key parameters to design a high-performance sensor. We also present different applications from metrology (for manual or automatic alignment of optics), to soft X-ray source optimization and X-ray imaging.

20 metrology↗

Bio-reduction of ferrihydrite-montmorillonite-organic matter complexes: Effect of montmorillonite and fate of organic matter

Organic matter (OM) is often associated with Fe (hydr)oxides such as ferrihydrite (Fh) in soils and sediments, forming binary Fh-OM complexes. Microbial reduction of Fh results in destabilization of the complexes and mineral/OM transformation. However, little is known about the role of clay minerals in such processes, despite their common co-existence with Fh and OM in natural environments. Here Fh-OM complexes were synthesized in the presence of montmorillonite (SWy-2), forming ternary Fh-(SWy-2)-OM complexes. A metal-reducing bacterium Geobacter sulfurreducens was used to reduce Fh in the complexes under circumneutral pH and anoxic conditions with or without H 2 as extra electron donor. Various spectroscopy and mass spectrometry methods were used to monitor the progress of Fh bio-reduction and mineral/OM transformation. Results showed that G. sulfurreducens utilized mineral-bound OM as electron donor and/or carbon source to couple with Fh reduction. Relative to Fh-OM complex, Addition of SWy-2 to Fh-OM complex enhanced the bio-reduction extent of Fh by increasing the proportion of bioavailable OM that was weakly bound to SWy-2. However, its effect on the bio-reduction rate was variable. SWy-2 initially decreased the rate, because it spatially separated OM (electron donor) from Fh (electron acceptor). During later incubation, SWy-2 increased the reduction rate by sorbing biogenic Fe 2+ that would otherwise passivate the Fh and cell surfaces. Bio-reduction transformed mineral-bound OM to microbial products (e.g. necromass, extracellular polymeric substances), but organic compounds with aromatic structures, carboxyl groups and large molecular weight were more resistant to desorption and oxidation. The persistence of these compounds against bio-reduction induced transformation is likely due to their stronger binding with minerals and/or lower nominal oxidation states of carbon relative to other compounds. Our results provide new insights into the role of clay minerals in regulating biogeochemical cycling of solid-phase Fe and transformation of mineral-associated OM in anoxic soil environments.

58 GEOSCIENCES↗

Power density calculation of spontaneous radiation emission from a finite emittance electron beam in planar undulators

We extend the angular power density formulae for spontaneous radiation emission from planar undulators to include finite emittance and angular misalignment of the electron beam. Then we calculate and compare power densities estimated from integral approach with Gaussian beam distribution and summation approach with macro-particle allocation covering particle beam phase space. After showing that both approaches converge to each other, we apply the macro-particle approach to study power absorbed and transmitted by various apertures at front end of 9-ID beamline at National Synchrotron Light Source-II for misaligned electron beam. Our analysis indicate that the electron beam misalignment could lead to unwarranted power deposition at tighter apertures that would have been otherwise difficult to account for during the aperture design/choice process.

43 PARTICLE ACCELERATORS↗

Wavefront Preservation in Soft X-Ray Beamlines for the Advanced Light Source Upgrade

In the 4th generation of X-ray light sources, including Free-Electron Lasers (FEL) and Diffraction-Limited Storage Rings (DLSR), the emittance of the electron beam is small or negligible compared to the emittance of the photon beam produced by insertion devices, thus generating coherent beams of light. Over the next few years, several lightsource facilities will be built or upgraded to produce X-ray beams of unprecedented coherent flux. Delivering these exceptional beams to the sample chambers requires beamline optical systems that are designed to preserve the wavefront properties. Our goal in the Advanced Light Source upgrade project (ALS-U) is to create a new class of beamlines that reach diffraction-limited X-ray optical quality through tightly integrated, efficient optical systems, diagnostics, and adaptive mirrors, thus providing users with new scientific capabilities offered by coherent X-ray light interactions with matter. Herein we describe aspects of the beamlines’ design as they enter the project’s final design phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accurate activity determination of a californium neutron source

Accurately counting analog events requires constructing an electronics chain that produces one count for each input pulse. Here, in this work, we review the use of Nuclear Instrumentation Module electronic units for counting neutron capture events in a 3He tube. We identify two unique types of false trigger events in a leading-edge discriminator and show how a dual timer module can be used to produce a veto window to exclude these events. We use the constructed electronics chain to build an apparatus to measure neutron pulses from a 252 Cf neutron source. We compare the measurements with a Monte Carlo N-Particle (MCNP) model to determine the activity of the neutron source. Furthermore, by making additional measurements with borated polyethylene attenuators between the source and detector, we are able to determine the boron concentration of the polyethylene. This technique provides accurate determination of the source activity to a precision of 2.8% at the k=1 level. The method used is simple, inexpensive, and requires no additional calibrated instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Carrier capture and emission by substitutional carbon impurities in GaN vertical diodes

A model was developed for the operation of a GaN pn junction vertical diode which includes rate equations for carrier capture and thermally activated emission by substitutional carbon impurities and carrier generation by ionizing radiation. The model was used to simulate the effect of ionizing radiation on the charge state of carbon. These simulations predict that with no applied bias, carbon is negatively charged in the n-doped layer, thereby compensating n-doping as experimentally observed in diodes grown by metal-organic chemical vapor deposition. With reverse bias, carbon remains negative in the depletion region, i.e., compensation persists in the absence of ionization but is neutralized by exposure to ionizing radiation. This increases charge density in the depletion region, decreases the depletion width, and increases the capacitance. The predicted increase in capacitance was experimentally observed using a pulsed 70 keV electron beam as the source of ionization. In additional confirming experiments, the carbon charge-state conversion was accomplished by photoionization using sub-bandgap light or by the capture of holes under forward bias.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wehnelt photoemission in an ultrafast electron microscope: Stability and usability

We tested and compared the stability and usability of three different cathode materials and configurations in a thermionic-based ultrafast electron microscope: (1) on-axis thermionic and photoemission from a custom 100 μm diameter LaB 6 source with a graphite guard ring, (2) off-axis photoemission from the Ni aperture surface of the Wehnelt electrode, and (3) on-axis thermionic and photoemission from a custom 200 μm diameter polycrystalline Ta source. For each cathode type and configuration, including the Ni Wehnelt aperture, we illustrate how the photoelectron beam-current stability is deleteriously impacted by simultaneous cooling of the source following thermionic heating. Furthermore, we demonstrate usability via collection of parallel- and convergent-beam electron diffraction patterns and by formation of the optimum probe size. We find that usability of the off-axis Ni Wehnelt-aperture photoemission is at least comparable to on-axis LaB 6 thermionic emission, as well as to on-axis photoemission [the heretofore conventional approach to ultrafast electron microscopy (UEM) in thermionic-based instruments]. However, the stability and achievable beam currents for off-axis photoemission from the Wehnelt aperture were superior to that of the other cathode types and configurations, regardless of the electron-emission mechanism. Beam-current stability for this configuration was found to be ±1% (one standard deviation from the mean) for 70 min (longest duration tested), and steady-state beam current was reached within the sampling-time resolution used here (~1 s) for 15 pA beam currents (i.e., 460 electrons per packet for a 200 kHz repetition rate). Repeatability and robustness of the steady-state condition were also found to be within ±1% of the mean. We discuss the implications of these findings for UEM imaging and diffraction experiments, for pulsed-beam damage measurements, and for practical switching between optimum conventional TEM and UEM operation within the same instrument.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring Saturn's Electron Beam Energy Spectrum using Webb's Wedges

It is very difficult to measure the voltage of the load on the Saturn accelerator. Time-resolved measurements such as vacuum voltmeters and V-dot monitors are impractical at best and completely change the pulsed power behavior at the load at worst. We would like to know the load voltage of the machine so that we could correctly model the radiation transport and tune our x-ray unfold methodology and circuit simulations of the accelerator. Step wedges have been used for decades as a tool to measure the end - point energies of high energy particle beams. Typically, the technique is used for multi-megavolt accelerators, but we have adapted it to Saturn's modest <2 MV end-point energy and modified the standard bremsstrahlung x-ray source to extract the electron beam without changing the physics of the load region. We found clear evidence of high energy electrons >2 MV. We also attempted to unfold an electron energy spectrum using a machine learning algorithm and while these results come with large uncertainties, they qualitatively agree with PIC simulation results.

43 PARTICLE ACCELERATORS↗

High Intensity Gamma-Ray Source(HIγS) Radiographic Experiments

High Intensity Gamma-ray Source (HIGS) is a Free-Electron Laser (FEL) based Compton back-scattering γ-ray source. The HIGS facility is located on the campus of Duke University and operated by Triangle Universities Nuclear Laboratory (TUNL).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Editorial: Microbial C1 Metabolism and Biotechnology

Archaea and bacteria with the capacity to utilize one-carbon (C1) molecules as carbon and energy sources are widespread across the planet and are important players in many biogeochemical processes. As such, they occupy an array of diverse anaerobic and aerobic niches and perform unique metabolisms that enable the utilization of carbon dioxide (CO 2 ), carbon monoxide (CO), formate (HCOOH), methanol (CH 3 OH), and methane (CH 4 ) for growth. Several industrial processes have been developed that leverage these microbes for the targeted conversion of anthropogenic waste gases that contain C1 molecules, including natural gas (CH 4 ), anaerobic digestion-derived biogas (CH 4 and CO 2 ), industrial flue gas (CO 2 and CO), and syngas (CO 2 , CO, and H 2 ) (Figure 1). Further, there is increasing interest in electrochemical reduction of CO 2 to CO, CH 4 , and intermediates with increased solubility compared to gaseous C1 molecules (formate and methanol) using electrons derived from renewable sources like wind, solar, or hydrothermal systems to mitigate atmospheric greenhouse gas. Thus, C1-utilizing microbes will likely play an integral role in biotechnologies that are part of a sustainable, circular bioeconomy. However, fundamental knowledge gaps into the metabolism and physiology of these microbes exist that limit their utility as biocatalysts for carbon-efficient biomanufacturing. This special topic presents studies focused on the fundamental aspects of C1 metabolism in diverse microbial systems with the ability to convert anthropogenic greenhouse gases into valuable products.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a broadband hard x-ray radiography platform for pulsed-power experiments

In this article, we develop and demonstrate a broadband hard x-ray radiography platform at the Zebra Pulsed Power Laboratory that integrates point-projection radiography, bremsstrahlung measurements, and hard x-ray pinhole imaging, designed to diagnose current-driven, cylindrically compressed matter. Initial laser-pulsed-power coupled experiments revealed that intense background radiation generated during 1 MA Zebra current shots overwhelmed laser-produced hard x-rays, obscuring radiographic images. Using combined spectral and spatial diagnostics, we identify energetic electrons accelerated by return currents as the dominant source of background hard x-rays, with electron energies inferred to be 3–4 MeV based on Monte Carlo simulations, and demonstrate mitigation through modifications to the radiation shielding and return-current configuration. The diagnostic platform was validated using a wire-pinch hard x-ray source, allowing radiographs of static 1-mm-diameter aluminum wires to be obtained while simultaneously measuring x-ray source spectra and spatial emission distributions within a single shot. Measured wire transmission profiles were quantitatively reconstructed using radiation transport simulations that incorporate an experimentally inferred two-temperature exponential x-ray spectrum from bremsstrahlung signal analysis and spatially distributed emission sources identified by pinhole imaging. Agreement between measured and simulated transmission profiles demonstrates the validity of the radiographic and x-ray source characterization approach, establishing this diagnostic platform as a promising tool for diagnosing magnetically driven, high-density plasmas relevant to warm dense matter and inertial fusion energy research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Broad sterile neutrinos & the reactor/gallium tension

Significant evidence exists for the apparent disappearance of electron-type neutrinos in radioactive source experiments. Yet, interpreted within the standard ‘3+1 sterile neutrino scenario’, precision short-baseline measurements of electron antineutrinos from nuclear reactors strongly disagree with these results. Recently, it has been demonstrated that allowing for a finite wavepacket size for the reactor neutrinos can ameliorate such a tension, however the smallness of the required wavepackets is a subject of intense debate. In this work, we demonstrate that a ‘broad’ sterile neutrino may relax this tension in much the same way. Such a phenomenological possibility can arise in plausible hidden sector scenarios, such as a clockwork-style sector, for which we provide a concrete microscopic model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

All polymer microfluidic chips—A fixed target sample delivery workhorse for serial crystallography

The development of x-ray free electron laser (XFEL) light sources and serial crystallography methodologies has led to a revolution in protein crystallography, enabling the determination of previously unobtainable protein structures and near-atomic resolution of otherwise poorly diffracting protein crystals. However, to utilize XFEL sources efficiently demands the continuous, rapid delivery of a large number of difficult-to-handle microcrystals to the x-ray beam. A recently developed fixed-target system, in which crystals of interest are enclosed within a sample holder, which is rastered through the x-ray beam, is discussed in detail in this Perspective. The fixed target is easy to use, maintains sample hydration, and can be readily modified to allow a broad range of sample types and different beamline requirements. Recent innovations demonstrate the potential of such microfluidic-based fixed targets to be an all-around “workhorse” for serial crystallography measurements. In conclusion, this Perspective will summarize recent advancements in microfluidic fixed targets for serial crystallography, examine needs for future development, and guide users in designing, choosing, and utilizing a fixed-target sample delivery device for their system.

59 BASIC BIOLOGICAL SCIENCES↗