Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron ion collider”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Hadron blind Cherenkov counters

A Hadron Blind Detector, or HBD, is a novel form of Cherenkov counter that is designed to provide high efficiency for detecting highly relativistic electrons while being essentially blind to most hadrons. Herein, we present some of the most prominent realizations of the HBD concept in real experiments. We describe the first implementation of an HBD that was made in the CERES experiment at CERN using a spectrometer based on a doublet of hadron blind RICH detectors for the measurement of low-mass electron pairs in pA and AA collisions at the SPS. We next present a detailed account of a more extensive realization of the HBD that was made in the PHENIX experiment for the measurement of low-mass electron pairs in central heavy-ion collisions at RHIC, followed by a description of a very similar detector that is currently under construction at J-PARC for the measurement of vector mesons through their e + e – decay in pA collisions. We conclude with a brief discussion of possible evolutions of the HBD concept as well as possible developments and uses of HBDs in experiments at the future Electron Ion Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reconstructing the kinematics of deep inelastic scattering with deep learning

We introduce a method to reconstruct the kinematics of neutral-current deep inelastic scattering (DIS) using a deep neural network (DNN). Unlike traditional methods, it exploits the full kinematic information of both the scattered electron and the hadronic-final state, and it accounts for QED radiation by identifying events with radiated photons and event-level momentum imbalance. The method is studied with simulated events at HERA and the future Electron–Ion Collider (EIC). We show that the DNN method outperforms all the traditional methods over the full phase space, improving resolution and reducing bias. Our method has the potential to extend the kinematic reach of future experiments at the EIC, and thus their discovery potential in polarized and nuclear DIS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A SiPM-based optical readout system for the EIC dual-radiator RICH

Silicon photomultipliers (SiPM) are candidates selected as the potential photodetector technology for the dual-radiator Ring-Imaging Cherenkov (dRICH) detector at the future Electron-Ion Collider (EIC). SiPM are cheap devices, highly efficient and insensitive to the high magnetic field at the expected location of the sensors in the experiment. Here, on the other hand, SiPM are not radiation tolerant. Despite the integrated radiation level is expected to be moderate it should be tested whether single photon-counting capabilities and the increase in dark count rate can be kept under control to maintain the optimal dRICH detector performance across the years. The current status of the research for the EIC dRICH application and the first results on studies performed on a sample of commercial and prototype SiPM sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alignment of the CLAS12 central hybrid tracker with a Kalman Filter

Several factors can contribute to the difficulty of aligning the sensors of tracking detectors, including a large number of modules, multiple types of detector technologies, and non-linear strip patterns on the sensors. All three of these factors apply to the CLAS12 CVT, which is a hybrid detector consisting of planar silicon sensors with non-parallel strips, and cylindrical micromegas sensors with longitudinal and arc-shaped strips located within a 5 T superconducting solenoid. To align this detector, we used the Kalman Alignment Algorithm, which accounts for correlations between the alignment parameters without requiring the time-consuming inversion of large matrices. This is the first time that this algorithm has been adapted for use with hybrid technologies, non-parallel strips, and curved sensors. We present the results for the first alignment of the CLAS12 CVT using straight tracks from cosmic rays and from a target with the magnetic field turned off. After running this procedure, we achieved alignment at the level of 10 µm, and the widths of the residual spectra were greatly reduced. These results attest to the flexibility of this algorithm and its applicability to future use in the CLAS12 CVT and other hybrid or curved trackers, such as those proposed for the future Electron-Ion Collider.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for e → τ charged lepton flavor violation at the EIC with the ECCE detector

The recently approved Electron-Ion Collider (EIC) will provide a unique new opportunity for searches of charged lepton flavor violation (CLFV) and other new physics scenarios. In contrast to the e ↔ μ CLFV transition for which very stringent limits exist, there is still a relatively large discovery space for the e → τ CLFV transition, potentially to be explored by the EIC. Here, with the latest detector design of ECCE (EIC Comprehensive Chromodynamics Experiment) and projected integral luminosity of the EIC, we find the τ-leptons created in the DIS process ep → τX are expected to be identified with high efficiency. A first ECCE simulation study, restricted to the 3-prong τ-decay mode and with limited statistics for the Standard Model backgrounds, estimates that the EIC will be able to improve the current exclusion limit on e → τ CLFV by an order of magnitude. As a result, the very high vertex resolution of the ECCE detector configuration plays a critical role in τ identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large radial shift experiments in RHIC and their implications for EIC design

The Hadron Storage Ring (HSR) in the future Electron-Ion Collider (EIC) must operate over a broad range of design circumferences. In 2018 preliminary beam studies on the circumference adjustment capabilities of the Relativistic Heavy Ion Collider (RHIC) were performed by applying a small momentum offset to the circulating bunches without adjusting any bending magnets. The off-momentum linear optics were corrected back to on-momentum conditions. Applying a similarly small deviation to the dipole fields of a select set of bending magnets provides a large radial shift over much of the RHIC (or HSR) circumference while leaving the design trajectory unchanged in the insertion regions. Here, this paper presents the design of the different lattice configurations foreseen as the most viable options for the required HSR circumference changes, and highlights the modifications necessary for regular operations and to allow for testing these new settings in RHIC. Experimental results from 2021 and 2022 are reviewed and compared to model predictions obtained from both MAD-X and Bmad. The implications of these results for HSR design are discussed.

43 PARTICLE ACCELERATORS↗

Finite element modeling of electropolishing of radio frequency dipole Nb crab cavity in hydrofluoric-sulfuric acid electrolyte

The superior performance of niobium superconducting radio frequency (SRF) cavities is achieved through meticulous surface treatment, notably via chemical electropolishing, ensuring exceptionally smooth surfaces. While this technique has been extensively employed for cylindrically symmetric structures, addressing more intricate geometries poses significant challenges in achieving uniform polishing and controlled material removal, especially when moving away from retractable cathodes. This presents a multifaceted electrochemical, thermal, and fluid dynamics conundrum. A prime example is the 197 MHz radio frequency dipole (RFD) crabbing cavity proposed for the Electron Ion Collider (EIC) project, exemplifying such complex structures. Our groundbreaking work integrates the localized oxide thickness variation, considering its impact on current distribution and Joule heating, within the framework of multi-physics modeling using the COMSOL® simulation suite. This approach was applied to a comprehensive model of the RFD cavity, allowing us to investigate optimal external cooling water flow conditions necessary for achieving desirable outcomes. In conclusion, this illustrates the increasing utility of such multi-physics codes to greatly aid in designing solutions to challenging processing requirements for increasingly complex accelerator cavities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and simulation of a SiPM-on-tile ZDC for the future EIC, and its performance with graph neural networks

We present a design for a high-granularity zero-degree calorimeter (ZDC) for the upcoming Electron-Ion Collider (EIC). The design uses SiPM-on-tile technology and features a novel staggered-layer arrangement that improves spatial resolution. To fully leverage the design’s high granularity and non-trivial geometry, we employ graph neural networks (GNNs) for energy and angle regression as well as signal classification. The GNN-boosted performance metrics meet, and in some cases, significantly surpass the requirements set in the report on science requirements and detector requirements for the EIC (Yellow Report), laying the groundwork for enhanced measurements that will facilitate a wide physics program. Our studies show that GNNs can significantly enhance the performance of high-granularity CALICE-style calorimeters by automating and optimizing the software compensation algorithms required for these systems. This improvement holds true even in the case of complicated geometries that pose challenges for image-based AI/ML methods.

Calorimeter↗

HRPPD photosensors for RICH detectors with a high resolution timing capability

Recently, a new version of DC-coupled High Rate Picosecond Photodetectors (DC-HRPPDs) substantially re-designed for use at the Electron-Ion Collider (EIC) has been developed. A first batch of seven “EIC HRPPDs” was manufactured in early 2024. These HRPPDs are DC-coupled photosensors based on Micro-Channel Plates (MCPs) that have an active area of 104 mm by 104 mm, 32 × 32 direct readout pixel array at a pitch of 3.25 mm, peak quantum efficiency in excess of 30%, exceptionally low dark count rates and timing resolution of 15–20 ps for a single photon detection. As such, these photosensors are very well suited for Ring Imaging CHerenkov (RICH) detectors that can additionally provide high resolution timing capability, especially in a configuration where a detected charged particle passes through the sensor window, which produces a localized flash containing a few dozens of Cherenkov photons in it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulation study for particle identification with the dRICH of the ePIC experiment at the EIC

The dual-radiator Imaging Cherenkov detector (dRICH), employing an aerogel and a gas radiator, is a key component of the forward particle identification system for the ePIC experiment at the Electron-Ion Collider (EIC). This study evaluates the dRICH performance using Geant4 simulations in the context of the global ePIC simulation stack, focusing on the optimization of the aerogel radiator and the impact of sensor noise. We compare two aerogel configurations: the initial design (n = 1.019) and the current default (n = 1.026). The latter, characterized by improved optical properties and a higher refractive index, demonstrates enhanced π/K separation at high momenta, effectively extending the operational overlap with the C 2 F 6 gas radiator (n = 1.00076 at 25 °C, as implemented in the simulation software). Additionally, the study investigates the impact of Silicon Photomultiplier (SiPM) dark noise, showing that a 300 kHz noise rate per 3mm x 3mm channel leads to a moderate reduction (approximately 1.5 GeV/c) in the 3σ separation threshold. These results validate the current dRICH design and quantify the purity levels achievable for both radiators under expected experimental conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

How EIC can help us to understand heavy-ion collisions

In this work, I give a brief overview of the science cases of the Electron-Ion Collider (EIC) with a particular emphasis on the connections to the physics of ultrarelativistic heavy-ion collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Collins asymmetries for pion-in-jet production in polarized ℓp collisions at the EIC

We study Collins azimuthal asymmetries for pion-in-jet production in polarized lepton-proton collisions, extending previous analyses of polarized pp scattering to a complementary and theoretically simpler process. We keep adopting a simplified transverse momentum dependent (TMD) approach, with a collinear configuration for the initial state, and employ the transversity and Collins fragmentation functions as extracted from semi-inclusive deep inelastic scattering and $e^{+}e^{-}$ annihilation processes. We then compute azimuthal asymmetries for the Electron-Ion Collider (EIC) kinematics, both within a leading order (LO) approach and by including quasireal photon exchange in the Weizsäcker-Williams approximation. Although this contribution is relevant in the whole kinematical range explored, it does not spoil the dominance of quark-initiated channels, leaving only a marginal role to their gluon counterparts. In this respect, Collins asymmetries in lepton-proton processes allow for a much clearer access to the transversity distribution, including its sea-quark component. As we will argue, a comparison with future EIC data could represent a further step in testing the hypothesis of the universality of the Collins function as well as of the TMD factorization for this class of processes.

Azimuthal asymmetries↗

Toward an event-level analysis of hadron structure using differential programming

Reconstructing the internal properties of hadrons in terms of fundamental quark and gluon de- grees of freedom is a central goal in nuclear and particle physics. This effort lies at the core of major experimental programs, such as the Jefferson Lab 12 GeV program and the upcoming Electron-Ion Collider. A primary challenge is the inherent inverse problem: converting large-scale observational data from collision events into the fundamental QCD-defined densities that characterize the micro- scopic structure of hadronic systems. Recent advances in AI and machine learning have opened new avenues for addressing this challenge using deep learning techniques. A particularly promising direction is the integration of complex theoretical calculations and experimental simulations into a unified framework capable of reconstructing these densities directly from event-level information. In this document, we introduce a key algorithm called LOITS, which enables differentiable program- ming within such a framework, facilitating the use of AI/ML techniques to solve the inverse problem of QCF reconstruction at the event level.

Braga, Kevin [College of William and Mary, William↗

What we know and what we don’t know about the proton spin after 30 years

More than three decades ago, the European Muon Collaboration published a surprising result on the spin structure of the proton: the spins of its three quark components account for only a small part of the spin of the proton. Furthermore, ever since, theoretical and experimental progress has been made in understanding the origins of the proton spin. In this review, we discuss what has been learned so far, what is still missing and what could be learned from the upcoming experiments, including the Jefferson Lab 12GeV upgrade and the proposed Electron-Ion Collider. In particular, we focus on first-principles calculations and experimental measurements of the total gluon helicity ΔG, and the quark and gluon orbital angular momenta.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lessons for delivering big science projects

As the construction of the Electron-Ion Collider (EIC) is starting, here, the EIC Project Director Jim Yeck shares his experience on the main ingredients for success of big science projects.

43 PARTICLE ACCELERATORS↗

JANA2 Framework for Event Based and Triggerless Data Processing

Development of the second generation JANA2 multi-threaded event processing framework is ongoing through an LDRD initiative grant at Jefferson Lab. The framework is designed to take full advantage of all cores on modern many-core compute nodes. JANA2 efficiently handles both traditional hardware triggered event data and streaming data in online triggerless environments. Development is being done in conjunction with the Electron Ion Collider development. Anticipated to be the next large scale Nuclear Physics facility constructed. The core framework is written in modern C++ but includes an integrated Python interface. The status of development and summary of the more interesting features are presented.

Lawrence, David↗

Federated Access from DOE Labs to Distributed Storage in the EIC Era of Computing

The Electron Ion Collider (EIC) collaboration and future experiment is a unique scientific ecosystem within Nuclear Physics as the experiment starts right off as a crosscollaboration between Brookhaven National Lab (BNL) & Jefferson Lab (JLab). As a result, this muti-lab computing model tries at best to provide services accessible from anywhere by anyone who is part of the collaboration. While the computing model for the EIC is not finalized, it is anticipated that the computational and storage resources will be made accessible to a wide range of collaborators across the world. The use of federated ID seems to be a critical element to the strategy of providing such services, allowing seamless access to each lab site computing resources. However, providing Federated access to a Federated storage is not a trivial matter and has its share of technical challenges. In this contribution, we focus on the steps we took towards the deployment of a distributed object storage system that integrates with Amazon S3 and Federated ID. We will first cover for and explain the first stage storage solutions provided to the EIC during the detector design phase. Our initial test deployment consisted of Lustre storage using MinIO, hence providing an S3 interface. High Availability load balancers were added later to provide the initial scalability it lacked. Performance of that system will be shown. While this embryonic solution worked well, it had many limitations. Looking ahead, the Ceph object storage is considered a top-of-the-line solution in the storage community - since the Ceph Object Gateway is compatible with the Amazon S3 API out of the box, our next phase will use a native S3 storage. Our Ceph deployment will consist of erasure coded storage nodes to maximize storage potential along with multiple Ceph Object Gateways for redundant access. We will compare performance of our next stage implementations. Finally, we will present how to leverage OpenID Connect with the Ceph Object Gateway’s to enable Federated ID access. We hope this contribution will serve the community needs as we move forward with cross-lab collaborations and the need for Federated ID access to distributed compute facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MCP-PMT development at Argonne for particle identification

The proposed high-energy high-luminosity polarized Electron-Ion Collider (EIC) demands excellent particle identification over a wide range of particles momenta to achieve the best separation between signal and background particles. Various Cherenkov imaging detector sub-systems are being considered in EIC detector concepts for hadron identification for particles momenta up to 50 GeV/c. One important challenge in this case is to provide a reliable highly pixelated photosensor working in the high radiation and high magnetic field environment. The recently commercialized Large Area Picosecond Photo-Detector (LAPPD) provides a promising low-cost photosensor solution for the various EIC Cherenkov imaging sub-systems. Optimization of the phtosensor design for high magnetic field tolerance, precision timing resolution, and pixelated readout was performed at Argonne National Laboratory with 6 x 6 cm(2) microchannel plate photomultipliers. The techniques and optimized design parameters would be transferrable to industrial partners for low-cost LAPPD production to achieve the demonstrated performance.

atomic layer deposition↗