Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Initial Steps Towards a Clinical FLASH Radiotherapy System: Pediatric Whole Brain Irradiation with 40 MeV Electrons at FLASH Dose Rates

In this work, we investigated the delivery of a clinically acceptable pediatric whole brain radiotherapy plan at FLASH dose rates using two lateral opposing 40-MeV electron beams produced by a practically realizable linear accelerator system. The EGSnrc Monte Carlo software modules, BEAMnrc and DOSXYZnrc, were used to generate whole brain radiotherapy plans for a pediatric patient using two lateral opposing 40-MeV electron beams. Electron beam phase space files were simulated using a model of a diverging beam with a diameter of 10 cm at 50 cm SAD (defined at brain midline). The electron beams were collimated using a 10-cm-thick block composed of 5 cm of aluminum oxide and 5 cm of tungsten. For comparison, a 6-MV photon plan was calculated with the Varian AAA algorithm. Electron beam parameters were based on a novel linear accelerator designed for the PHASER system and powered by a commercial 6-MW klystron. Calculations of the linear accelerator's performance indicated an average beam current of at least 6.25 µA, providing a dose rate of 115 Gy/s at isocenter, high enough for cognition-sparing FLASH effects. The electron plan was less homogenous with a homogeneity index of 0.133 compared to the photon plan's index of 0.087. Overall, the dosimetric characteristics of the 40-MeV electron plan were suitable for treatment. In conclusion, Monte Carlo simulations performed in this work indicate that two lateral opposing 40-MeV electron beams can be used for pediatric whole brain irradiation at FLASH dose rates of >115 Gy/s and serve as motivation for a practical clinical FLASH radiotherapy system, which can be implemented in the near future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First degraded beams in the CEBAF injector

The electron beam degrader in the Continuous Electron Beam Accelerator Facility (CEBAF) injector at Jefferson Lab serves to generate electron beams with transverse emittance over 10x the nominal values, with the ultimate goal of using degraded electron beams to measure machine acceptance. Electron beams are degraded through multiple scattering in thin carbon foils, and maximum transverse emittance is defined through two collimating apertures. The degrader device was installed in late 2024, with commissioning and first beams on degrader targets during the 2025 physics run. We report on first operation of the degrader device. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under contract DE-AC05-06OR23177.

Sy, A. [Thomas Jefferson National Accelerator Faci↗

Nanoscale optical tomography with cathodoluminescence spectroscopy

In one aspect, a cathodoluminescence (CL) spectroscopic tomography device includes a sample stage to support a sample. An electron beam source scans an electron beam over the sample to yield light emission by the sample. A reflective element directs the light emission by the sample to a light detector. A controller controls operation of the sample stage, the electron beam source, and the light detector. In one aspect, a CL spectroscopic tomography device includes an electron beam source which directs an electron beam at an object to yield an emission by the object. A detector detects the emission. A controller receives information from the detector related to the detected emission. The controller derives a two-dimensional (2D) CL map from the information related to the detected emission, and derives a three-dimensional (3D) CL tomogram from the 2D CL map.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Attosecond-Angstrom free-electron-laser towards the cold beam limit

Electron beam quality is paramount for X-ray pulse production in free-electron-lasers (FELs). State-of-the-art linear accelerators (linacs) can deliver multi-GeV electron beams with sufficient quality for hard X-ray-FELs, albeit requiring km-scale setups, whereas plasma-based accelerators can produce multi-GeV electron beams on metre-scale distances, and begin to reach beam qualities sufficient for EUV FELs. Here we show, that electron beams from plasma photocathodes many orders of magnitude brighter than state-of-the-art can be generated in plasma wakefield accelerators (PWFAs), and then extracted, captured, transported and injected into undulators without significant quality loss. These ultrabright, sub-femtosecond electron beams can drive hard X-FELs near the cold beam limit to generate coherent X-ray pulses of attosecond-Angstrom class, reaching saturation after only 10 metres of undulator. This plasma-X-FEL opens pathways for advanced photon science capabilities, such as unperturbed observation of electronic motion inside atoms at their natural time and length scale, and towards higher photon energies.

43 PARTICLE ACCELERATORS↗

Direct Fabrication of Atomically Defined Pores in MXenes Using Feedback-Driven STEM

Controlled fabrication of nanopores in 2D materials offer the means to create robust membranes needed for ion transport and nanofiltration. Techniques for creating nanopores have relied upon either plasma etching or direct irradiation; however, aberration-corrected scanning transmission electron microscopy (STEM) offers the advantage of combining a sub-Å sized electron beam for atomic manipulation along with atomic resolution imaging. Here, for this work, a method for automated nanopore fabrication is utilized with real-time atomic visualization to enhance the mechanistic understanding of beam-induced transformations. Additionally, an electron beam simulation technique, Electron-Beam Simulator (E-BeamSim) is developed to observe the atomic movements and interactions resulting from electron beam irradiation. Using the MXene Ti 3 C 2 T x , the influence of temperature on nanopore fabrication is explored by tracking atomic transformations and find that at room temperature the electron beam irradiation induces random displacement and results in titanium pileups at the nanopore edge, which is confirmed by E-BeamSim. At elevated temperatures, after removal of the surface functional groups and with the increased mobility of atoms results in atomic transformations that lead to the selective removal of atoms layer by layer. This work can lead to the development of defect engineering techniques within functionalized MXene layers and other 2D materials.

36 MATERIALS SCIENCE↗

Beamline for E-beam processing at UITF

Electron beam irradiation is a method that has shown a good potential to reduce several pollutants in wastewater. One of the main challenges towards wider adoption of this method is the need for compact, reliable, cost-effective, high-power accelerators. Jefferson Lab is working on the design and prototyping of accelerator components, based on superconducting radio-frequency (SRF) technology, aiming at accelerators for industrial applications. The LDRD project aimed at designing, procuring, installing, and commissioning a beamline at the Upgraded Injector Test Facility (UITF) accelerator to allow electron-beam irradiation studies of different materials, beginning with wastewater. The availability of such beamline allows exploring the ability of electron-beam radiation to reduce or eliminate so-called “forever chemicals” that can be found in wastewater or industrial sites. After successful commissioning, the beamline was used to irradiate wastewater samples with different concentrations of 1,4-dioxane, in collaboration with Hampton Roads Sanitation District (HRSD).

42 ENGINEERING↗

Diamagnetic Loop Testing on DARHT-I

Diamagnetic loops (DML) can be used as a noninvasive method for measurements of beam size in electron beam accelerators that use solenoidal magnetic transport. The loop fundamentally measures the magnetic flux excluded by a diamagnetic object. A comprehensive theory relates the rms beam radius to the excluded flux measured by the DML. We have built, and calibrated a DML apparatus. Recently, this DML has been used to measure the size of the electron beam near the final focus of the DARHT-I flash-radiography accelerator. Results are in agreement with beam transport code predictions. In this article, we review and summarize the construction, calibration, and electron-beam testing of this DML.

43 PARTICLE ACCELERATORS↗

Diagnosing the DARHT Electron Beam-Target Interaction and Hydrodynamic Expansion [Dissertation]

Quantitative electron beam-target interaction studies on the Dual-Axis Radiographic Hydrodynamic Test (DARHT) electron linear induction accelerators have only been performed recently. This includes characterization of the temperature, density, pressure, extent, and expansion velocity of the plasma plume. The results presented in this dissertation present a detailed and unified overview of the accelerator systems, target heating physics, beam transport, and diagnostic tools. Additional information includes calibration sources, radiation hydrodynamics, spectroscopic-quality radiation transport modeling, experimental measurements, and analyses of electron beam driven aluminum experiments. The first set of spatially and temporally resolved spectroscopic measurements of electron beam driven aluminum are presented. Contamination quantification analyses are used to understand the origin of the strong Na-I 3p-3s lines that are observed in absorption within the aluminum plasma continuum. These results inform the creation of the first spectroscopic-quality radiation transport model that links several atomic physics codes to interpret the conditions from which the Na-I lines originate. A good agreement is found between the surface analysis results and the model which confirms the concentration of the sodium present within the aluminum alloy foil material. It also demonstrates, for the first time on electron beam-driven target experiments, the ability to interpret plasma conditions from measured absorption lines. In a second experimental campaign which focuses on pure aluminum, the Al-I 3p-4s and 3p3d doublets are both measured in emission. A detailed analysis of the Al-I 3p-4s doublet reveals that the lines undergo moderate self-absorption. A simple model of the self-absorption effect is successfully used to match measured spectra at various temperature/density/plasma scale length combinations. These measurements led to the realization of the minimum density that can be resolved by the spectrometers for the Al-I 3p-4s lines due to the large slit width required to observe a signal on aluminum. These measurements also demonstrate the sensitivity of visible and long wave UV spectroscopy to minor changes in both temperature and density. The simple self-absorption model will be useful for analysis of other beam-target interaction experiments with spectra exhibiting either self-absorption or full self-reversal. Substantial headway has been made on the modeling front by linking together several codes needed to model both the energy deposition, hydrodynamic motion, and atomic kinetics to produce synthetic spectral calculations that are compared with experimental measurements. There exists ample space for improvement, especially with benchmarking the hydrodynamics codes and equation-of-state tables with experimental measurements. The X-ray diagnostics required to make these new measurements along with the simulation capabilities required to interpret the results are under development and will be the subject of future studies.

43 PARTICLE ACCELERATORS↗

Precise electron beam-based target-wavelength trimming for frequency conversion in integrated photonic resonators

We demonstrate post-fabrication target-wavelength trimming with a gallium phosphide on a silicon nitride integrated photonic platform using controlled electron-beam exposure of hydrogen silsesquioxane cladding. A linear relationship between the electron-beam exposure dose and resonant wavelength red-shift enables deterministic, individual trimming of multiple devices on the same chip to within 30 pm of a single target wavelength. Second harmonic generation from telecom to near infrared at a target wavelength is shown in multiple devices with quality factors on the order of 10 4 . Post-fabrication tuning is an essential tool for targeted wavelength applications including quantum frequency conversion.

Thiel, Lillian↗

Measurements of Electron Beam-Induced Spin-Relaxation in Frozen-Spin Hydrogen-Deuteride (HD)

Targets of solid hydrogen-deuteride (HD) can be prepared in a frozen-spin state with spin relaxation times (T1) in excess of a year. The present work has studied their potential use in experiments with electron beams. Polarization relaxation rates have been measured during exposure to sub-nanoAmp currents of 9.7 MeV electron beams from the recently commissioned Upgraded Injector Test Facility (UITF) at Jefferson Lab (JLab). These UITF measurements can be used to anticipate the expected performance at the GeV energies typical of JLab experiments, since the energy deposition in a target is almost independent of beam energy. An in-beam dilution refrigerator equipped with superconducting solenoids has been used to maintain solid HD samples at ?0.1 K and ?1 tesla, and internal NMR coils have been used to monitor hydrogen polarization. Spin-relaxation in two frozen-spin targets, with initial H-polarizations of 40% and 34%, have been tracked while exposed to beams under varying conditions of current, dose, beam duty factor and temperature. At a fixed accumulated dose, the spin-relaxation rates drop with current, suggesting depolarization by the charge cloud of the beam. Imposing a duty factor on the otherwise continuous UITF beam, with forced millisecond scale gaps, has shown no obvious correlation to polarization loss rates. After an accumulated dose of ?2 ?C/cm2, beam-off spin-relaxation rates drop from their immeasurably long pre-irradiation values to the order of weeks (with beam-on T1 values typically an order of magnitude shorter), reflecting a buildup of paramagnetic charge centers within the HD lattice. The accumulated polarization loss was approximately proportional to dose in both targets, dropping to 1/e of their initial values after ?6 ?C/cm2. Thermal equilibrium polarizations of targets not in the frozen-spin state (with intentionally short T1) have been used to deduce the in situ temperature of solid HD while under electron bombardment. A model for depolarization by beam-associated paramagnetic impurities largely accounts for the data, and suggests that improvements in heat removal could lead to significant increases in the in-beam T1.

O'Connell, Thomas↗

First-Principles Simulation of Beam-Induced Processes Underlying Atomic Manipulation in Electron Microscopes

The development of experimental methods and apparatuses capable of promoting atomically precise material manipulations holds great promise for realizing the ultimate limit of feature miniaturization in materials and devices. The ability to modify materials atom by atom is anticipated to usher in new technologies in areas as diverse as separation science, medicine, and quantum information science. Historically, scanning probe-based techniques have been the most prominent approaches in this space. However, these methods are best suited for the manipulation of surface-exposed regions of materials, as the strong perturbations required for bond scission are delivered most effectively to atoms in the near-proximity to the scanning probe. In contrast, convergent electron beams with energies tuned slightly below the threshold for inducing irreversible knock-on damage have recently been employed (within scanning transmission electron microscopy) to promote atomic-scale bond rearrangements in various beam-stable solids. Currently, however, the efficiency and selectivity of beam-induced atomic manipulation processes with focused electron beams are such that long irradiation times are required to induce a desired atomic rearrangement. With a better understanding of the underlying physics dictating the outcome of a given irradiation event, methods can be devised to improve the efficiency of these techniques so that their promise can be fully realized through widespread adoption.To this end, this Account details our recent efforts to develop and apply tractable first-principles simulation approaches for studying the response of materials to electric beam-like external electric potentials applied in real space. We briefly review the concepts and capabilities in the area of atomically precise materials manipulation and review the early demonstrations of accomplishments in this area, focusing on studies using scanned convergent electron beam probes in particular. We expound upon the depth of the challenge and identify critical shortcomings of theoretical methods that have previously been employed in the simulation of beam-induced processes. We then describe the computational methods that we have generalized from the concepts and tools most commonly applied to the study of molecular photochemistry and how our adaptations of these methods can be employed to capture the relevant dynamical phenomena for beam-induced processes ranging from the initial electron scattering to the ensuing multistate reactions. Here, we contextualize these methods within the current state of the art in this area, which has historically focused primarily on the simulation of inelastic image formation in the electron microscope for the purpose of interpreting the results of quantitative electron microscopy experiments. We demonstrate that the spatial distribution of state-specific excitation rates due to the presence of an external (probe) electric charge is inhomogeneous, such that irradiation at particular locations in materials can favor specific electronic transitions (and disallow others). In addition to the potential for excited-state reaction pathways to be accessed through the initial inelastic scattering of the tightly focused electron beam from the targeted atoms, we also identify favorable conditions for the electronically nonadiabatic evolution of the highly vibrationally excited system to open complex multistate reaction pathways. Implications of the early results for understanding the mechanisms and potential routes to improved efficiency and selectivity in beam-induced reactions are discussed. We conclude with a summary of the current state of theory and modeling capabilities in this area and provide our perspective on future directions for theoretical and experimental developments that we view as crucial to advancing the use of convergent electron beams in mode-specific, atomically precise platforms for direct-write materials modifications.

36 MATERIALS SCIENCE↗

Electron beam-induced nanopores in Bernal-stacked hexagonal boron nitride

Controlling the size and shape of nanopores in two-dimensional materials is a key challenge in applications such as DNA sequencing, sieving, and quantum emission in artificial atoms. Here, we investigate experimentally and theoretically triangular vacancies in (unconventional) Bernal-stacked AB-h-BN formed using a high-energy electron beam. Due to the geometric configuration of AB-h-BN, triangular pores in different layers are aligned, and their sizes are controlled by the duration of the electron irradiation. Interlayer covalent bonding at the vacancy edge is not favored, as opposed to what occurs in the more common AA'-stacked BN. A variety of monolayer, concentric and bilayer pores in bilayer AB-h-BN are observed in high-resolution transmission electron microscopy and characterized using ab initio simulations. Bilayer pores in AB-h-BN are commonly formed, and grow without breaking the bilayer character. Nanopores in AB-h-BN exhibit a wide range of electronic properties, ranging from half-metallic to non-magnetic and magnetic semiconducting. Therefore, because of the controllability of the pore size, the electronic structure is also highly controllable in these systems, and can potentially be tuned for particular applications.

2D materials↗

SRF e-beam accelerator for metal additive manufacturing

A system and apparatus for electron beam melting comprises a superconducting radio frequency accelerator configured to produce an electron beam, a conduction cooling system configured to cool the superconducting radio frequency accelerator, and an electron beam melting system wherein the electron beam melts power in a build chamber of the electron beam melting apparatus.

Thangaraj, Jayakar C.↗

Evaluation of a High-Power Target Design for Positron Production at CEBAF

A source for polarized positron beams at the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab is being designed. The Polarized Electrons for Polarized Positrons (PEPPo) concept is used to produce polarized e$^+$e$^-$-pairs from the bremsstrahlung radiation of a longitudinally polarized electron beam interacting within a high-Z conversion target. The scheme under consideration includes a 4 mm thick tungsten target that absorbs 17 kW deposited by a 1 mA continuous-wave electron beam with an energy of 120 MeV. The concept of a rotating tungsten rim mounted on a water-cooled copper disk was explored. The results of ANSYS thermal and mechanical analyses are discussed together with FLUKA evaluations of the radiation damages.

Ushakov, A.↗

Evaluation of a High-Power Target Design for Positron Production at CEBAF

A source for polarized positron beams at the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab is being designed. The Polarized Electrons for Polarized Positrons (PEPPo) concept is used to produce polarized e$^+$e$^-$-pairs from the bremsstrahlung radiation of a longitudinally polarized electron beam interacting within a high-Z conversion target. The scheme under consideration includes a 4 mm thick tungsten target that absorbs 17 kW deposited by a 1 mA continuous-wave electron beam with an energy of 120 MeV. The concept of a rotating tungsten rim mounted on a water-cooled copper disk was explored. The results of ANSYS thermal and mechanical analyses are discussed together with FLUKA evaluations of the radiation damages.

Ushakov, A.↗

On electron beam-induced degradation of vinyl ester thermosets

We have demonstrated that electron beam radiolysis induces scissions of the C-O-C bonds along the backbone of the chains of unsaturated polyester thermosets of different compositions based on dicyclopentadiene, isophthalic acid, epoxy vinyl ester, and terephthalic acid. The radiolysis is imminent irrespective of the degree of crosslinking in the thermosets both in neat resins and in the presence of solvents. Electron Paramagnetic Resonance (EPR) results show the formation of the alkoxyl radicals and C-centered radicals as the primary intermediate products of the C-O-C scissions. While the alkoxyl radicals of these resins exhibit very good stability even six months after the irradiation, the C-centered radicals decay very rapidly via their reactions with oxygen that is available either as adsorbed in the resins, dissolved in solvents or from the environment. The radiolytically produced •OH radicals in the unsaturated-ester aqueous solutions play a major role in inducing scissions on the backbone of the polymer chains. The solvated electrons (e s ) from organic solvents, such as dimethyl sulfoxide and isopropyl alcohol, also induce direct scission of the C-O-C bonds, giving rise to the formation of alkoxyl radicals and C-centered radicals. However, a considerable fraction of es is scavenged by the dissolved O 2 to produce O 2 - . Despite the radiation-induced scissions, irradiation of the resins at a dose level of 1000 kGy results in an increase of the glass transition temperature, Tg. This is due to the simultaneous radiation-induced polymerization of the vinyl monomers, toluene, and styrene that are present in the resins. The increase in Tg is observed in all the resins except for the terephthalic polyester resin in aqueous solution, in which the absence of these monomers results in Tg decreasing sharply with irradiation. This work demonstrates that ionizing radiation triggers continuous free radical-chain reactions that lead to the formation of recyclable oligomers.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Broadband coherent XUV light from e − / e + microbunching in an intense laser pulse

Attosecond pulses of coherent extreme ultraviolet (XUV) light are instrumental for investigating subatomic dynamics and can be produced using a free-electron laser (FEL). It has been suggested that an optical FEL, which employs a laser pulse in place of a conventional undulator, could enable a dramatically more compact implementation of such a light source. Yet, the high electron density and subsequent high emittance implied by an optical FEL makes this concept challenging to realize with an electron beam. There has been impressive progress in recent years producing collimated dense and relativistic beams of electrons and positrons in the laboratory. As we demonstrate here, the inherent stability of a quasi-neutral electron-positron beam mitigates Coulomb expansion, and renders it a promising alternative source of coherent light. Specifically, we show via computer simulations that broadband coherent light in the XUV domain, which takes the form of 8-as pulses at 92-as intervals, can be generated by microbunching of relativistic electrons and positrons in a laser pulse. This process occurs over a sub-millimeter length scale, enabling the development of light sources which are orders-of-magnitude more compact than existing sources, with potential applications in physics, chemistry, biology, and industry.

47 OTHER INSTRUMENTATION↗

SRF E - Beam Accelerator for Metal Additive Manufacturing [Patent]

A system and apparatus for electron beam melting comprises a superconducting radio frequency accelerator configured to produce an electron beam, a conduction cooling system configured to cool the superconducting radio frequency accelerator, and an electron beam melting system wherein the electron beam melts power in a build chamber of the electron beam melting apparatus.

43 PARTICLE ACCELERATORS↗