Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron beam instabilities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

X-ray diagnostics for the cavity-based x-ray free-electron laser project

The success of x-ray free-electron lasers (XFELs) in recent years has greatly advanced many scientific fields. However, most of these XFELs suffer from a low longitudinal coherence and instabilities due to the stochastic start-up process. A cavity-based x-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent and stable x-ray sources. One of the challenges of a CBXFEL is the requirement for the μ⁢m−sized electron bunches to fully overlap in three dimensions with the circulating μ⁢m−sized x-ray pulses in an x-ray cavity tens or hundreds of meters long. We present here the development of an x-ray diagnostics system for accurate alignment of x-ray beams in the CBXFEL cavity. The system was developed within the framework of a CBXFEL research and development collaboration among Argonne National Laboratory, SLAC National Accelerator Laboratory, and Spring-8. All the designed diagnostic components have been fully characterized at the Advanced Photon Source to demonstrate a capability for sub-μ⁢rad angular and μ⁢m spatial alignment of the CBXFEL cavity.

Free-electron lasers↗

Electromagnetic instabilities driven by unequal proton beams in the solar wind

The paper sets forth a numerical investigation of the linear dispersion relation for typical solar wind conditions at 1 AU during those times (high-speed streams) when a secondary beam of protons drifting relative to the main proton component is present. Three beam-driven instabilities were found to occur as the beam drift velocity approaches the Alfven speed: (1) a pure, field-aligned magnetosonic wave that is most important at relatively high beta and/or high beam drift speeds; (2) an oblique magnetosonic wave having highest growth rates 15-30 deg from the magnetic field; and (3) an oblique Alfven wave having maximum growth rates at increasing angle to the magnetic field. The linear growth rates for the field-aligned magnetosonic and the Alfven oblique modes are investigated as a function of relative beam density, varying anisotropic pitch angle distributions for the various components, electron temperature, and electron heat flux.

Montgomery, M. D.↗

Impedance and wakefield studies of the EIC RCS 591 MHz five-cell cavity

The Electron-Ion Collider (EIC) is a next-generation accelerator complex designed to enable high-luminosity collisions between highly polarized electrons and light ions (e.g., He-3). A central component of its Electron Injection System (EIS) is the Rapid Cycling Synchrotron (RCS), which accelerates a single 28 nC electron bunch from 750 MeV to 5, 10, or 18 GeV using an array of 591 MHz five-cell superconducting RF (SRF) cavities—eight at the current design stage. To ensure stable acceleration of high-charge bunches, we conducted detailed impedance and wakefield studies of the SRF cavity structure using both frequency- and time-domain methods. Wakefield solvers (ECHO3D, ECHO1D, CST), eigenmode analysis, and multi-particle tracking with ELEGANT were employed to evaluate longitudinal and transverse impedance effects and to determine instability thresholds. These studies provide critical input for the cavity design and operating parameters required to preserve beam quality and stability in the RCS.

Accelerator Physics↗

BEAM DYNAMICS CHALLENGES IN THE DESIGN OF THE ELECTRON-ION COLLIDER

The Electron-Ion Collider (EIC), presently under construction at Brookhaven National Laboratory, will collide polarized high-energy electron beams with hadron beams, achieving luminosities up to 1 × 1034 cm¿2 s¿1 in the center-of-mass energy range of 20-140 GeV. To achieve such high luminosity, we adopt high bunch intensities for both beams, small and flat transverse beam sizes at the interaction point (IP), a large crossing angle of 25 mrad, and a novel strong hadron cooling in the Hadron Storage Ring (HSR) to counteract intra-beam scattering (IBS) at the collision energy. In this talk, we will review the beam dynamics challenges in the design of the EIC, particularly the single-particle dynamic aperture, polarization maintenance, beam-beam interaction, impedance budget and instabilities. We will also briefly mention some technical challenges associated with beam dynamics, such as strong hadron cooling, multipoles and noises of crab cavities, power supply current ripples, and the vacuum upgrade to existing beam pipes of the Hadron Storage Ring of the EIC.

Luo, Y.↗

Equivalent equilibrium ion distributions in ion sources and beams

Ion sources and ion beams often contain ions of more than one charge-to-mass ratio, due to the presence of multiple ionization states and/or multiple atomic and molecular ion species in the source. We show that, under certain conditions, analysis of these systems can be simplified using the notion of “equivalent equilibrium ion distributions” (EEIDs). These distributions have identical ion trajectories, space-charge distributions, and electric-field distributions, but can be composed of ion species with arbitrary charge-to-mass ratios. We use this result to obtain multi-species generalizations for the perveance of an ion diode, which relates the diode voltage to the extracted beam current, and for the perveance of a drifting ion beam, which determines the axial length-scale for beam expansion due to the self-electric field. Applied to a quasi-neutral plasma ion source containing cold ions and hot electrons, we find that the location of the beam-plasma interface (meniscus), where ions are extracted from the plasma, depends on the electron density and ion energy per unit charge at the interface, independent of the ion composition. For certain types of numerical simulations, EEIDs allow one to calculate the beam optics of an intense multi-species ion source by doing a simulation for a single ion species with an artificial charge-to-mass ratio chosen to minimize computation time. We illustrate these results using the 3D particle-in-cell, finite-element code Aleph. The simulations show how ions in a plasma source self-consistently accelerate to the supersonic speed needed for steady, radially expanding flow. Multi-species equilibria are subject to streaming instabilities because, while the different species have the same kinetic energy per unit charge, their velocities scale with the square root of the charge-to-mass ratio. The simulations show that a strong ion streaming instability can occur in a multi-species plasma ion source.

74 ATOMIC AND MOLECULAR PHYSICS↗

Transmission Electron Microscopy (TEM) Sample Preparation of Si(1-x)Gex in c-Plane Sapphire Substrate

The National Aeronautics and Space Administration-invented X-ray diffraction (XRD) methods, including the total defect density measurement method and the spatial wafer mapping method, have confirmed super hetero epitaxy growth for rhombohedral single crystalline silicon germanium (Si1-xGex) on a c-plane sapphire substrate. However, the XRD method cannot observe the surface morphology or roughness because of the method s limited resolution. Therefore the authors used transmission electron microscopy (TEM) with samples prepared in two ways, the focused ion beam (FIB) method and the tripod method to study the structure between Si1-xGex and sapphire substrate and Si1?xGex itself. The sample preparation for TEM should be as fast as possible so that the sample should contain few or no artifacts induced by the preparation. The standard sample preparation method of mechanical polishing often requires a relatively long ion milling time (several hours), which increases the probability of inducing defects into the sample. The TEM sampling of the Si1-xGex on sapphire is also difficult because of the sapphire s high hardness and mechanical instability. The FIB method and the tripod method eliminate both problems when performing a cross-section TEM sampling of Si1-xGex on c-plane sapphire, which shows the surface morphology, the interface between film and substrate, and the crystal structure of the film. This paper explains the FIB sampling method and the tripod sampling method, and why sampling Si1-xGex, on a sapphire substrate with TEM, is necessary.

Kim, Hyun Jung↗

Temporally Stable Supramolecular Polymeric Salts Enabling High-Performance 3D All-Aromatic Polyimide Lattices

Vat photopolymerization (VP) Additive Manufacturing (AM), in which UV light is selectively applied to cure photo-active polymers into complex geometries with micron-scale resolution, has a limited selection of aliphatic thermoset materials that exhibit relatively poor thermal performance. Ring-opening dianhydrides with acrylate-containing nucleophiles yielded diacrylate ester-dicarboxylic acids that enabled photo-active polyimide (PI) precursors, termed polysalts, upon neutralization with an aromatic diamine in solution. In situ FTIR spectroscopy coupled with a solution and photo-rheological measurements revealed a previously unknown time-dependent instability of 4,4'-oxydianiline (ODA) polysalts due to an aza-Michael addition. Replacement of the electron-donating ether-containing diamine with an electron withdrawing sulfone-containing monomer, e.g., 4,4'-diaminodiphenyl sulfone (DDS), prohibited the aza-Michael addition of the aromatic amine to the activated acrylate double bond. Novel DDS polysalt photocurable solutions are similarly analyzed and validated long-term stability, which enabled reproducible printing of polyimide organogel intermediates. Subsequent VP AM afforded 3-dimensional (3D) structures of intricate complexity and excellent surface finish, as demonstrated with scanning electron microscopy. In addition, the novel PMDA-HEA/DDS solution enabled the production of the first beam latticed architecture comprised of all-aromatic polyimide. Finally, the versatility of a polysalt platform for multi-material printing is further demonstrated by printing parts with alternating polysalt compositions.

36 MATERIALS SCIENCE↗

Electron Cloud Measurements in Fermilab Booster

Fermilab Booster synchrotron requires an intensity upgrade from 4.5x1012 to 6.5x1012 protons per pulse as a part of Fermilabs Proton Improvement Plan-II (PIP-II). One of the factors which may limit the high-intensity performance is the fast transverse instabilities caused by electron cloud effects. According to the experience in the Recycler, the electron cloud gradually builds up over multiple turns in the combined function magnets and can reach final intensities orders of magnitude greater than in a pure dipole. Since the Booster synchrotron also incorporates combined function magnets, it is essential to discover any existence of an electron cloud. And if it does, its effects on the PIP-II era Booster and its mitigating techniques. As the first step, the presence or absence of the electron cloud was investigated using the clearing bunch technique. This paper presents experimental details and observations of the bunch-by-bunch tune shifts of beams with various bunch train structures at low and high intensities and simulation results conducted using PyECLOUD.

43 PARTICLE ACCELERATORS↗

Magnetosheath-ionspheric plasma interactions in the cusp/cleft. 2: Mesoscale particle simulations

Ionospheric plasma flowing out from the cusp can be an important source of plasma to the magnetosphere. One source of free energy that can drive this outflow is the injection of magnetosheath plasma into the cusp. Two-dimensional (three velocity) mesoscale particle simulations are used to investigate the particle dynamics in the cusp during southward interplanetary magnetic field. This mesoscale model self-consistently incorporates (1) global influences such as the convection of plasma across the cusp, the action of the mirror force, and the injection of the magnetosheath plasma, and (2) wave-particle interactions which produce the actual coupling between the magnetosheath and ionospheric plasmas. It is shown that, because the thermal speed of the electrons is higher than the bulk motion of the magnetosheath plasma, an upward current is formed on the equatorward edge of the injection region with return currents on either side. However, the poleward return currents are the stronger due to the convection and mirroring of many of the magnetosheath electrons. The electron distribution in this latter region evolves from upward directed streams to single-sided loss cones or possibly electron conics. The ion distribution also shows a variety of distinct features that are produced by spatial and/or temporal effects associated with varying convection patterns and wave-particle interactions. On the equatorward edge the distribution has a downflowing magnetosheath component and an upflowing cold ionospheric component due to continuous convection of ionospheric plasma into the region. In the center of the magnetosheath region, heating from the development of an ion-ion streaming instability causes the suppression of the cold ionospheric component and the formation of downward ionospheric streams. Further poleward there is velocity filtering of ions with low pitch angles, so that the magnetosheath ions develop a ring-beam distribution and the ensuing wave instabilities generate downward ionospheric conics. These downward ionospheric components are eventually turned by the mirror force, leading to the production of upward conics at elevated energies throughout the region.

Winglee, R. M.↗

Turbulent resistivity, diffusion and heating

Experimental and theoretical studies are reported on ion acoustic and ion cyclotron turbulence and their roles in anomalous resistivity, viscosity, diffusion and heating and in the structure of collisionless electrostatic shocks. Resistance due to ion acoustic turbulence has been observed in experiments with a streaming cesium plasma in which electron current, potential rise due to turbulent resistivity, spectrum of unstable ion acoustic waves, and associated electron heating were all measured directly. Kinetic theory calculations for an expanding, unstable plasma, give results in agreement with the experiment. In a strong magnetic field, with T sub e/T sub i approximately 1 and current densities typical for present Tokomaks, the plasma is stable to ion acoustic but unstable to current driven electrostatic ion cyclotron waves. Relevant characteristics of these waves are calculated and it is shown that for ion, beta greater than m sub e/m sub i, the electromagnetic ion cyclotron wave has a lower instability threshold than the electrostatic one. However, when ion acoustic turbulence is present experiments with double plasma devices show rapid anomalous heating of an ion beam streaming through a plasma.

Fried, B. D.↗

Conceptual design and performance predictions for 2D beam emission spectroscopy turbulence measurements at Wendelstein 7-X

A conceptual design for a 2D beam emission spectroscopy diagnostic system to measure ion gyro-scale plasma turbulence at Wendeslstein 7-X is described. The conceptual design identifies field-aligned viewing geometries and ports for cross-field turbulence measurements in the neutral beam volume. A 2D sightline grid covers the outer plasma region, and the grid configuration provides sufficient k-space coverage in radial and poloidal directions for ion temperature gradient and trapped-electron mode turbulence measurements. Emission intensity estimates, optical transmission losses, and detector noise levels indicate that the measurements will be sensitive to plasma density fluctuations as small as δn/n ≈ 0.5% with a bandwidth of 1 MHz. Implementation challenges include a small beam emission Doppler shift due to nearly radial heating beams and reduced optical throughput due to collection aperture limitations.

47 OTHER INSTRUMENTATION↗

On the theory of CIV

The critical ionization velocity (CIV) phenomenon involves the transfer of energy from neutrals moving relative to a plasma to electrons. Three mechanisms are discussed and illustrated with numerical simulations. If the elastic electron neutral collision frequency is large (comparable to the electron cyclotron frequency) the electrons can gain enough energy from the neutrals to ionize them. Newly created ions form beams in the plasma which are unstable to lower hybrid waves propagating obliquely to the magnetic field. These waves have an electric field component parallel to the background magnetic field which can accelerate electrons. However, the efficiency of this heating is significantly reduced by electromagnetic effects which occur when the relative velocity exceeds the Alfven speed or when the plasma beta is large. A third mechanism involves the E x B drift of electrons in the secondary electric field due to charge separation at the front of a neutral gas cloud. This E field is opposite to the neutral gas velocity and can be much larger than the polarization field. The electron drift excites the modified two-stream instability which causes rapid electron heating and thus ionization in the front.

Goertz, C. K.↗

Design elements and first data from a new Doppler backscattering system on the MAST-U spherical tokamak

A new Doppler backscattering (DBS) system has been installed and tested on the MAST-U spherical tokamak. It utilizes eight simultaneous fixed frequency probe beams (32.5, 35, 37.5, 40, 42.5, 45, 47.5, and 50 GHz). These frequencies provide a range of radial positions from the edge plasma to the core depending on plasma conditions. The system utilizes a combination of novel features to provide remote control of the probed density wavenumber, the launched polarization (X vs O-mode), and the angle of the launched DBS to match the magnetic field pitch angle. The range of accessible density turbulence wavenumbers (kθ) is reasonably large with normalized wavenumbers kθρs ranging from ≤0.5 to 9 (ion sound gyroradius ρs = 1 cm). This wavenumber range is relevant to a variety of instabilities believed to be important in establishing plasma transport (e.g., ion temperature gradient, trapped electron, electron temperature gradient, micro-tearing, kinetic ballooning modes). The system is specifically designed to address the requirement of density fluctuation wavevector alignment which can significantly reduce the SNR if not accounted for.

Instruments & Instrumentation↗

Wave production in an ultrarelativistic electron-positron plasma

In this paper we calculate the eigenmodes associated with an ultrarelativistic electron-positron beam traversing a low-energy electron-positron plasma under physical conditions that may exist along open magnetic field lines above pulsar polar caps. We assume that both beam and plasma are cold and charge neutral, and that magnetic field strength and particle density decrease as the cube of (1/R). In the superstrong magnetic fields near the stellar surface where cyclotron frequencies exceed plasma frequencies, electrostatic waves and associated transverse low-frequency waves are driven unstable by the two-stream type particle distribution. At larger distances above the stellar surface the slow beam cyclotron wave is driven unstable. At even greater radial distance (approximately when particle energy density exceeds magnetic energy density) both the Ordinary and Alfven modes become unstable. All of these instabilities can lead to generation of radiation. If the particle distribution as generated at the stellar surface, assumed to consist of two streams, is modified only by plasma effects, then electrostatic and associated transverse waves may only be unstable near the stellar surface. The beam cyclotron mode which is driven by a two-stream or an inverted particle distribution may be stable.

Hardee, P. E.↗

Measurement techniques using the electron beam profile scanner at the Fermilab Main Injector

This work presents techniques for non-invasive transverse profile measurements of high-intensity proton beams using an Electron Beam Profile Scanner (EBPS). The EBPS utilizes low-energy electrons as a probe to analyze the transverse size of proton beams, allowing for potential analysis on a single-bunch basis. Recent upgrades to the Fermilab Main Injector have enhanced beam power on target to 1 MW, with future developments targeting 2 MW. The higher beam power has increased the demand for non-invasive diagnostics, as invasive methods can disrupt operations.The techniques presented include 1) the slow scan technique, which serves as a proof of concept for the probe beam, 2) the one-shot scan technique for measuring horizontal beam profiles, and 3) the raster scan technique for analyzing horizontal beam profiles as a function of the longitudinal distribution of the beam. The profiles obtained will be crucial for studying and understanding instabilities in high-power, high-intensity proton beams. This will contribute to optimizing the operation of high-power proton accelerators by minimizing beam loss, activation, and damage to both the diagnostics and the accelerator components.

Mwaniki, Matilda [IIT, Chicago]↗

Broadband Frequency Conversion of Spectrally Incoherent Pulses and Initial Laser-Plasma Instabilities Mitigation Experiments

There is a need for efficient broadband frequency conversion schemes from the infrared, where optical pulses are efficiently amplified by solid-state laser materials, to the ultraviolet, a wavelength range more suitable for inertial confinement fusion (ICF). The current schemes are inadequate for broadband, spectrally incoherent optical pulses composed of a large number of frequency components distributed over a large frequency range. Implementing novel technologies that generate optical pulses with a large number of spectral components improves the laser-target interaction. In particular, it has long been believed that broad bandwidth mitigates the electron-plasma-wave instabilities that generate suprathermal electrons, which degrade ICF performance by increasing the fuel adiabat and reducing the shell areal density. It is important to develop a platform to demonstrate hot electron suppression caused by the larger available bandwidth, which has not previously been feasible in the laboratory. Experimentally measuring and theoretically assessing these effects with adequately benchmarked simulation codes are paramount to the design and development of novel laser facilities aiming at producing energy via laser fusion. The Laboratory for Laser Energetics is building a new laser facility, the Fourth-generation Laser for Ultrabroadband eXperiments (FLUX), to generate high-energy nanosecond laser pulses with fractional bandwidth larger than 1% in the ultraviolet and perform combined experiments with the 60-beam Omega facility. This large increase in bandwidth from the ~ 0.1% currently available on high-energy laser systems, is achieved by combining amplification in nonlinear optical parametric amplifiers (OPAs) around 1053 nm (1w) with nonlinear frequency conversion to the ultraviolet (around 351 nm, 3w). The novel scheme for frequency conversion is based on the noncollinear sum-frequency generation (SFG) of the angularly dispersed amplified 1w output with a narrowband 2w pulse, which is also used to pump the OPA system. The proposal funded scientific and engineering studies necessary to implement this novel laser facility, accelerated the SFG deployment by funding additional project team resources (shop time, engineers, and technicians), and funded preliminary experiments on the Omega Laser.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct Observation of Transient Structural Dynamics of Atomically Thin Halide Perovskite Nanowires

Halide perovskite is a unique dynamical system, whose structural and chemical processes happening across different timescales have significant impact on its physical properties and device-level performance. However, due to its intrinsic instability, real-time investigation of the structure dynamics of halide perovskite is challenging, which hinders the systematic understanding of the chemical processes in the synthesis, phase transition, and degradation of halide perovskite. Here, we show that atomically thin carbon materials can stabilize ultrathin halide perovskite nanostructures against otherwise detrimental conditions. Moreover, the protective carbon shells enable atomic-level visualization of the vibrational, rotational, and translational movement of halide perovskite unit cells. Albeit atomically thin, protected halide perovskite nanostructures can maintain their structural integrity up to an electron dose rate of 10,000 e – /Å 2 ·s while exhibiting unusual dynamical behaviors pertaining to the lattice anharmonicity and nanoscale confinement. Here, our work demonstrates an effective method to protect beam-sensitive materials during in situ observation, unlocking new solutions to study new modes of structure dynamics of nanomaterials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗