Numerical Simulations of Flow Separation Control in Low-Pressure Turbines using Plasma Actuators

A recently introduced phenomenological model to simulate flow control applications using plasma actuators has been further developed and improved in order to expand its use to complicated actuator geometries. The new modeling approach eliminates the requirement of an empirical charge density distribution shape by using the embedded electrode as a source for the charge density. The resulting model is validated against a flat plate experiment with quiescent environment. The modeling approach incorporates the effect of the plasma actuators on the external flow into Navier Stokes computations as a body force vector which is obtained as a product of the net charge density and the electric field. The model solves the Maxwell equation to obtain the electric field due to the applied AC voltage at the electrodes and an additional equation for the charge density distribution representing the plasma density. The new modeling approach solves the charge density equation in the computational domain assuming the embedded electrode as a source therefore automatically generating a charge density distribution on the surface exposed to the flow similar to that observed in the experiments without explicitly specifying an empirical distribution. The model is validated against a flat plate experiment with quiescent environment.

Suzen, Y. B.↗

Improved Devices for Collecting Sweat for Chemical Analysis

Improved devices have been proposed for collecting sweat for biochemical analysis - especially for determination of the concentration of Ca2+ ions in sweat as a measure of loss of Ca from bones. Unlike commercially available sweat-collection patches used previously in monitoring osteoporosis and in qualitative screening for some drugs, the proposed devices would not allow evaporation of the volatile chemical components (mostly water) of sweat. Moreover, the proposed devices would be designed to enable determination of the volumes of collected sweat. From these volumes and the quantities of Ca(2+) and/or other analytes as determined by other means summarized below, one could determine the concentrations of the analytes in sweat. A device according to the proposal would be flexible and would be worn like a commercial sweat-collection patch. It would be made of molded polydimethylsiloxane (silicone rubber) or other suitable material having properties that, for the purpose of analyzing sweat, are similar to those of glass. The die for molding the silicone rubber would be fabricated by a combination of lithography and electroplating. The die would reproducibly form, in the silicone rubber, a precisely defined number of capillary channels per unit area, each channel having a precisely defined volume. Optionally, electrodes for measuring the Ca(2+) content of the sweat could be incorporated into the device. The volume of sweat collected in the capillary channels of the device would be determined from (1) the amount of light or radio waves of a given wavelength absorbed by the device and (2) the known geometry of the array of capillary channels. Then, in one of two options, centrifugation would be performed to move the sweat from the capillary tubes to the region containing the electrodes, which would be used to measure the Ca(2+) content by a standard technique. In the other option, centrifugation would be performed to remove the sweat from the device to make the sweat available to other analytical instruments for measuring concentrations of substances other than Ca(2+).

Feedback, Daniel L.↗

Characterization of applied fields for ion mobility separations in traveling wave based structures for lossless ion manipulations (SLIM)

Ion mobility (IM) is rapidly gaining attention for the analysis of biomolecules due to the ability to distinguish the shapes of ions. However, conventional constant electric field drift tube IM has limited resolving power, constrained by practical limitations on the path length and maximum applied voltage. The implementation of traveling waves (TW) in IM removes the latter limitation, allowing higher resolution to be achieved using extended path lengths. These can be readily obtainable in structures for lossless ion manipulations (SLIM), which are fabricated from electric fields that are generated by appropriate potentials applied to arrays of electrodes patterned on two parallel surfaces. In this work we have investigated the relationship between the various SLIM variables, such as electrode dimensions, inter-surface gap, and the TW applied voltages, that directly impact the fields experienced by ions. Ion simulation and theoretical calculations have been utilized to understand the dependence of SLIM geometry and effective electric field. The variables explored impact both ion confinement and the observed IM resolution in Structures for Lossless Ion Manipulations (SLIM) modules.

Hamid, Ahmed M.↗

Analysis of shockless dynamic compression data on solids to multi-megabar pressures: Application to tantalum

Magnetically-driven, planar shockless-compression experiments to multi-megabar pressures were performed on tantalum samples using a stripline target geometry. Free-surface velocity waveforms were measured in 15 cases; nine of these in a dual-sample configuration with two samples of different thicknesses on opposing electrodes, and six in a single-sample configuration with a bare electrode opposite the sample. Details are given on the application of inverse Lagrangian analysis (ILA) to these data, including potential sources of error. The most significant source of systematic error, particularly for single-sample experiments, was found to arise from the pulse-shape dependent free-surface reflected wave interactions with the deviatoric-stress response of tantalum. This could cause local, possibly temporary, unloading of material from a ramp compressed state, and thus multi-value response in wave speed that invalidates the free-surface to in-material velocity mapping step of ILA. By averaging all 15 data sets, a final result for the principal quasi-isentrope of tantalum in stress-strain was obtained to a peak longitudinal stress of 330 GPa with conservative uncertainty bounds of ±4.5% in stress. The result agrees well with a tabular equation of state developed at Los Alamos National Laboratory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Particle-in-Cell Simulation for the Traveling Wave Direct Energy Converter (TWDEC) for Fusion Propulsion

A Particle-in-cell simulation model has been developed to study the physics of the Traveling Wave Direct Energy Converter (TWDEC) applied to the conversion of charged fusion products into electricity. In this model the availability of a beam of collimated fusion products is assumed; the simulation is focused on the conversion of the beam kinetic energy into alternating current (AC) electric power. The model is electrostatic, as the electro-dynamics of the relatively slow ions can be treated in the quasistatic approximation. A two-dimensional, axisymmetric (radial-axial coordinates) geometry is considered. Ion beam particles are injected on one end and travel along the axis through ring-shaped electrodes with externally applied time-varying voltages, thus modulating the beam by forming a sinusoidal pattern in the beam density. Further downstream, the modulated beam passes through another set of ring electrodes, now electrically oating. The modulated beam induces a time alternating potential di erence between adjacent electrodes. Power can be drawn from the electrodes by connecting a resistive load. As energy is dissipated in the load, a corresponding drop in beam energy is measured. The simulation encapsulates the TWDEC process by reproducing the time-dependent transfer of energy and the particle deceleration due to the electric eld phase time variations.

Chap, Andrew↗

Efficiency of thermoelectric energy conversion in biphenyl-dithiol junctions: Effect of electron-phonon interactions

The electron-phonon interaction is the dominant mechanism of inelastic scattering in molecular junctions. Here we report on its effect on the thermoelectric properties of single-molecule devices. Using density functional theory and the nonequilibrium Green’s function formalism we calculate the thermoelectric figure of merit for a biphenyl-dithiol molecule between two Al electrodes under an applied gate voltage. We find that the effect of electron-phonon coupling on the thermoelectric characteristics strongly varies with the molecular geometry. Two molecular configurations characterized by the torsion angles between the two phenyl rings of 30° and 90° exhibit significantly different responses to the inelastic scattering. We also use molecular dynamics calculations to investigate the torsional stability of the biphenyl-dithiol molecule and the phonon thermal transport in the junction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resistive heater geometry and regeneration method for a diesel particulate filter

One embodiment of the invention includes a diesel particulate filter comprising a first face and a second face; a bottom electrode layer formed over the first face of the diesel particulate filter; a middle resistive layer formed over a portion of the bottom electrode layer; and a top electrode layer formed over a portion of the middle resistive layer.

42 ENGINEERING↗

Solvent-Free Manufacturing of Lithium-Ion Battery Electrodes via Cold Plasma

Slurry casting has been used to fabricate lithium-ion battery electrodes for decades, which involves toxic and expensive organic solvents followed by high-cost vacuum drying and electrode calendering. This work presents a new manufacturing method using a nonthermal plasma to create inter-particle binding without using any polymeric binding materials, enabling solvent-free manufacturing electrodes with any electrochemistry of choice. The cold-plasma-coating technique enables fabricating electrodes with thickness (>200 μm), high mass loading (>30 mg cm -2 ), high peel strength, and the ability to print lithium-ion batteries in an arbitrary geometry. This crosscutting, chemistry agnostic, platform technology would increase energy density, eliminate the use of solvents, vacuum drying, and calendering processes during production, and reduce manufacturing cost for current and future cell designs. Here, lithium iron phosphate and lithium cobalt oxide were used as examples to demonstrate the efficacy of the cold-plasma-coating technique. It is found that the mechanical peel strength of cold-plasma-coating-manufactured lithium iron phosphate is over an order of magnitude higher than that of slurry-casted lithium iron phosphate electrodes. Full cells assembled with a graphite anode and the cold-plasma-coating-lithium iron phosphate cathode offer highly reversible cycling performance with a capacity retention of 81.6% over 500 cycles. For the highly conductive cathode material lithium cobalt oxide, an areal capacity of 4.2 mAh cm -2 at 0.2 C is attained. We anticipate that this new, highly scalable manufacturing technique will redefine global lithium-ion battery manufacturing providing significantly reduced plant footprints and material costs.

25 ENERGY STORAGE↗

Reducing Ohmic Resistances in Membrane Capacitive Deionization Using Micropatterned Ion-Exchange Membranes, Ionomer Infiltrated Electrodes, and Ionomer-Coated Nylon Meshes

Membrane capacitive deionization (MCDI) is an emerging water desalination platform that is compact, electrified, and does not require high-pressure piping. Herein, highly conductive poly(phenylene alkylene) ion-exchange membranes (IEMs) are micropatterned with different surface geometries for MCDI. The micropatterned membranes increase the interfacial area with the liquid stream leading to a 700 mV reduction in cell voltage when operating at constant current (2 mA cm -2 ; 2000 ppm NaCl feed) while improving the energy normalized adsorbed salt (ENAS) value by 1.4 times. Combining the micropatterned poly(phenylene alkylene) IEMs with poly(phenylene alkylene) ionomer-filled electrodes reduces the cell voltage by 1000 mV and improves the ENAS values by 2.3 times relative to the base case. This reduction in cell voltage allows for higher current density operation (i.e., 3–4 mA cm -2 ) . The reduction in cell voltage is ascribed to the ameliorating ohmic resistances related to ion transport at the membrane-process stream interface and in the carbon cloth electrode. Finally, porous ionic conductors are implemented into the spacer channel with flat and micropatterned IEM configurations and ionomer infiltrated electrodes. For the configuration with flat IEMs, the porous ionic conductor improves ENAS values across the current density regime (2–4 mA cm -2 ), while for micropatterned IEMs it gets improved only at 4 mA cm -2 .

42 ENGINEERING↗

Improving performance of the MgZnO ultraviolet photodetectors by changing the interdigital electrode width

Highlights: • The different electrode width of the metal-semiconductor-metal photodetectors are fabricated by the radio frequency magnetron sputtering technique. • The responsivity and the dark current of the photodetectors will vary with the electrode width. • The main reason of the interesting phenomenon is the change of the density of the carriers. - Abstract: We grow the Mg{sub 0.24}Zn{sub 0.76}O thin film onto a quartz substrate by the radio frequency magnetron sputtering technique. Planar geometry metal-semiconductor-metal structured ultraviolet detectors were fabricated by conventional ultraviolet lithography and wet etching on the Mg{sub 0.24}Zn{sub 0.76}O thin films. To improve the performance of the device, three kinds of photodetectors with different electrode width were fabricated, after a series of tests on those device, it is amusing to find an interesting phenomenon, the Mg{sub 0.24}Zn{sub 0.76}O photodetectors with different electrode width have a great influence on the performance of the whole device. The Mg{sub 0.24}Zn{sub 0.76}O photodetectors that own larger electrode width had a higher responsivity and lower dark current than the photodetectors own littler electrode width. These interesting results are very meaningful for the photodetector industry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Epidermal Differential Impedance Sensor for Conformal Skin Hydration Monitoring

We present the design and use of an ultrathin, stretchable sensor system capable of conformal lamination onto the skin, for precision measurement and spatial mapping of levels of hydration. This device, which we refer to as a class of ‘epidermal electronics’ due to its ‘skin-like’ construction and mode of intimate integration with the body, contains miniaturized arrays of impedance-measurement electrodes arranged in a differential configuration to compensate for common-mode disturbances. Experimental results obtained with different frequencies and sensor geometries demonstrate excellent precision and accuracy, as benchmarked against conventional, commercial devices. The reversible, non-invasive soft contact of this device with the skin makes its operation appealing for applications ranging from skin care, to athletic monitoring to health/wellness assessment.

47 OTHER INSTRUMENTATION↗

Current density distributions and sputter marks in electron cyclotron resonance ion sources

Most electron cyclotron resonance ion sources use hexapolar magnetic fields for the radial confinement of the plasma. The geometry of this magnetic structure is then-induced by charged particles-mapped onto the inner side of the plasma electrode via sputtering and deposition. The resulting structures usually show two different patterns: a sharp triangular one in the central region which in some cases is even sputtered deep into the material (referred to as thin groove or sharp structure), and a blurred but still triangular-like one in the surroundings (referred to as broad halo). Therefore, both patterns seem to have different sources. To investigate their origins we replaced the standard plasma electrode by a custom-built plasma electrode acting as a planar, multi-segment current-detector. For different biased disc voltages, detector positions, and source biases (referred to the detector) we measured the electrical current density distributions in the plane of the plasma electrode. The results show a strong and sharply confined electron population with triangular shape surrounded by less intense and spatially less confined ions. Observed sputter- and deposition marks are related to the analysis of the results. Our measurements suggest that the two different patterns (thin and broad) indeed originate from different particle populations. The thin structures seem to be caused by the hot electron population while the broad marks seem to stem from the medium to highly charged ions. In this paper we present our measurements together with theoretical considerations and substantiate the conclusions drawn above. The validity of these results is also discussed.

36 MATERIALS SCIENCE↗

Plasma Sheet Velocity Measurement Techniques for the Pulsed Plasma Thruster SIMP-LEX

The velocity of the first plasma sheet was determined between the electrodes of a pulsed plasma thruster using three measurement techniques: time of flight probe, high speed camera and magnetic field probe. Further, for time of flight probe and magnetic field probe, it was possible to determine the velocity distribution along the electrodes, as the plasma sheet is accelerated. The results from all three techniques are shown, and are compared for one thruster geometry.

Nawaz, Anuscheh↗

Three phase interfaces at electrified metal-solid electrolyte systems I. study of the Pt(hkl)-Nafion interface.

A voltammetric fingerprinting approach has been used to probe the nature of Pt-Nafion three phase interfaces for Pt(hkl) and polycrystalline platinum surfaces. Nature of adsorbing species is identified as the sulfonate anions via CO charge displacement technique. The affinity for the sulfonate anions to adsorb on the electrode surface is investigated. Adsorption strength of the sulfonate anions with the electrode surface is compared with other strongly adsorbing anions such as (bi) sulfates and chlorides. Various factors that influence the adsorption properties of the sulfonate anions are studied. Nature and strength of the anion interaction with various surface geometries is also discussed. A physical model is presented to describe the observed phenomena.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Moderate pressure plasma source of nonthermal electrons

Plasma sources of electrons offer control of gas and surface chemistry without the need for complex vacuum systems. The plasma electron source presented here is based on a cold cathode glow discharge (GD) operating in a dc steady state mode in a moderate pressure range of 2–10 torr. Ion-induced secondary electron emission is the source of electrons accelerated to high energies in the cathode sheath potential. The source geometry is a key to the availability and the extraction of the nonthermal portion of the electron population. The source consists of a flat and a cylindrical electrode, 1 mm apart. Our estimates show that the length of the cathode sheath in the plasma source is commensurate (~0.5–1 mm) with the inter-electrode distance so the GD operates in an obstructed regime without a positive column. Estimations of the electron energy relaxation confirm the non-local nature of this GD, hence the nonthermal portion of the electron population is available for extraction outside of the source. The use of a cylindrical anode presents a simple and promising method of extracting the high energy portion of the electron population. Langmuir probe measurements and optical emission spectroscopy confirm the presence of electrons with energies ~15 eV outside of the source. These electrons become available for surface modification and radical production outside of the source. In conclusion, the extraction of the electrons of specific energies by varying the anode geometry opens exciting opportunities for future exploration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electronic transport properties of one dimensional lithium nanowire using density functional theory

Single nanowire electrode devices are a unique platform for studying as energy storage devices. Lithium nanowire is of much importance in lithium ion batteries and therefore has received a great deal of attention in past few years. In this paper we investigated structural and electronic transport properties of Li nanowire using density functional theory (DFT) with SIESTA code. Electronic transport properties of Li nanowire are investigated theoretically. The calculations are performed in two steps: first an optimized geometry for Li nanowire is obtained using DFT calculations, and then the transport relations are obtained using NEGF approach. SIESTA and TranSIESTA simulation codes are used in the calculations correspondingly. The electrodes are chosen to be the same as the central region where transport is studied, eliminating current quantization effects due to contacts and focusing the electronic transport study to the intrinsic structure of the material. By varying chemical potential in the electrode regions, an I-V curve is traced which is in agreement with the predicted behavior. Agreement of bulk properties of Li with experimental values make the study of electronic and transport properties in lithium nanowires interesting because they are promising candidates as bridging pieces in nanoelectronics. Transmission coefficient and V-I characteristic of Li nano wire indicates that Li nanowire can be used as an electrode device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma Sputter-type Ion Source with Wire Electrodes for Low-energy Gallium Ion Extraction

Low-energy ions of gallium (Ga) and argon (Ar) were extracted from a plasma sputter-type ion source system that utilized a tungsten (W) wire extractor geometry. The 90% transparent W wire extractor configuration had shown that the system was capable of producing an ion beam with the energy as low as 10 eV in a dc filament discharge and 50 eV in a radio frequency (rf) excited system. In the present investigation, Ar plasma was sustained in an ion source chamber through an inductively coupled 13.56 MHz rf power source. Negatively biased liquid Ga target suspended on a W reservoir was sputtered and postionized prior to extraction. Mass spectral analyses revealed a strong dependence of the Ga{sup +} current on the induced target bias.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Miniature Inchworm Actuators Fabricated by Use of LIGA

Miniature inchworm actuators that would have relatively simple designs have been proposed for applications in which there are requirements for displacements of the order of microns or tens of microns and for the ability to hold their positions when electric power is not applied. The proposed actuators would be members of the class of microelectromechanical systems (MEMS), but would be designed and fabricated following an approach that is somewhat unusual for MEMS. Like other MEMS actuators, the proposed inchworm actuators could utilize thermoplastic, bimetallic, shape-memory-alloy, or piezoelectric actuation principles. The figure depicts a piezoelectric inchworm actuator according to the proposal. As in other inchworm actuators, linear motion of an extensible member would be achieved by lengthening and shortening the extensible member in synchronism with alternately clamping and releasing one and then the other end of the member. In this case, the moving member would be the middle one; the member would be piezoelectric and would be shortened by applying a voltage to it. The two outer members would also be piezoelectric; the release of the clamps on the upper or lower end would be achieved by applying a voltage to the electrodes on the upper or lower ends, respectively, of these members. Usually, MEMS actuators cannot be fabricated directly on the side walls of silicon wafers, yet the geometry of this actuator necessitates such fabrication. The solution, according to the proposal, would be to use the microfabrication technique known by the German acronym LIGA - "lithographie, galvanoformung, abformung," which means lithography, electroforming, molding. LIGA involves x-ray lithography of a polymer film followed by selective removal of material to form a three-dimensional pattern from which a mold is made. Among the advantages of LIGA for this purpose are that it is applicable to a broad range of materials, can be used to implement a variety of designs, including those of structures >1 mm high, affords submicron precision, and is amenable to mass production at relatively low unit cost. Fabrication of the proposed actuators would involve some technological risks - in particular, in the integration of electrode connection lines and placement of actuator elements. It will also be necessary to perform an intensive study of the feasibility of growing piezoelectric crystals onto LIGA molds.