Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical resistivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Machine Learning Application to Assess Occurrence and Saturations of Methane Hydrate in Marine Deposits Offshore India

Artificial Neural Networks (ANN) were used to assess methane hydrate occurrence and saturation in marine sediments offshore India. The ANN analysis classifies the gas hydrate occurrence into three types: methane hydrate in pore space, methane hydrate in fractures, or no methane hydrate. Further, predicted saturation characterizes the volume of gas hydrate with respect to the available void volume. Log data collected at six wells, which were drilled during the India National Gas Hydrate Program Expedition 02 (NGHP-02), provided a combination of well log measurements that were used as input for machine learning (ML) models. Well log measurements included density, porosity, electrical resistivity, natural gamma radiation, and acoustic wave velocity. Combinations of well logs used in the ML models provide good overall balanced accuracy (0.79 to 0.86) for the prediction of the gas hydrate occurrence and good accuracy (0.68 to 0.92) for methane hydrate saturation prediction in the marine accumulations against reference data. The accuracy scores indicate that the ML models can successfully predict reservoir characteristics for marine methane hydrate deposits. In conclusion, the results indicate that the ML models can either augment physics-driven methods for assessing the occurrence and saturation of methane hydrate deposits or serve as an independent predictive tool for those characteristics.

58 GEOSCIENCES↗

Advancing subsurface analysis: Integrating computer vision and deep learning for the near real-time interpretation of borehole image logs in the Illinois Basin-Decatur Project

The accurate quantification and mapping of subsurface natural fracture systems using borehole imaging logs are critical for the success of CO 2 sequestration in geologic formations, optimization of engineered geothermal systems, and hydrocarbon production enhancement. However, traditional interpretation processes suffer from time-consuming procedures and human bias. To address these challenges and expedite fracture analysis, we investigated the application of integrated computer vision and DL workflows to automate image log analysis. Specifically, the design of our workflow was crafted to swiftly detect fractures and baffles by using actual electrical resistivity of borehole wall from microresistivity imaging device alongside their binary representation. This novel approach significantly reduces computational time while providing invaluable insights. By incorporating conventional logging and microseismic data, we present a regional subsurface natural fracture mapping technique. Through the minimization of human bias in image log analysis, our automated workflow achieves reduced fracture interpretation time and costs while ensuring robust and reproducible results. We demonstrated the efficacy of our approach by applying the workflow to the Illinois Basin-Decatur Project site. The automated workflow successfully identified major fractured zones, multiple baffles, and an interbedded layer with a high resolution of 0.01 ft or 0.12 in. (0.3 cm) and can be upscaled to any desired resolution. Validation through microseismic and image log interpretations allows for accurate and near-real-time mapping of fractures and baffles, significantly enhancing CO 2 pressure forecasting and postinjection site care. Our approach stands out due to its robustness, consistency, and reduced computational cost compared with alternative feature extraction technologies. It presents exciting possibilities for advancing CO 2 sequestration and engineered geothermal efforts by offering comprehensive and efficient fracture mapping solutions. This technology can contribute significantly to the optimization of CO 2 sequestration projects, facilitating sustainable environmental practices, and combating climate change.

Geochemistry & Geophysics↗

Synthesis and structural characterization of orthorhombic Cu 3– δ Sb ( δ ≈ 0.1) and hexagonal Cu 3 Sb 1–x In x (x ≈ 0.2) phases

Cu 3 Sb is a known copper-rich phase in the Cu–Sb binary phase diagram. It is reported to be dimorphic, with a low-temperature form adopting the orthorhombic Cu 3 Ti structure type (space group Pmmn , No. 59). The high-temperature form crystallizes in the cubic space group F m 3 - m $Fm‾{3}m$ (No. 225), and is isostructural with BiF 3 . Neither polymorph has been carefully characterized to date, with both structures being assigned to the respective structure type, but never refined. With this study, we provide structural evidence, based on single-crystal and powder X-ray diffraction data that the low-temperature orthorhombic phase exists with a significant amount of defects on one of the Cu-sites. As a result, its composition is not Cu 3 Sb, but rather Cu 3– δ Sb ( δ = 0.13(1)). The cubic form could not be accessed as a part of this study, but another Cu-rich phase, Cu 3 Sb ≈0.8 In ≈0.2 , was also identified. It adopts the hexagonal Ni 3 Sn structure type (space group P 6 3 / mmc , No. 194) and represents an In-substituted variant of a hitherto unknown structural modification of Cu 3 Sb. Whether the latter can exist as a binary phase, or what is the minimum amount of In inclusions needed to stabilize it remains to be determined. Measurements of the thermopower of Cu 3– δ Sb ( δ = 0.13(1)) were conducted in the range of 300–600 K and demonstrated a maximum value of ca. 50 μV/K at 600 K, indicative of a p -type transport mechanism. Electrical resistivity measurements for the same sample confirmed that it exhibits metallic-like behavior, with a room temperature value of 0.43 mΩ cm. Electronic structure calculations show the absence of a band gap. Thermal analysis was utilized to ascertain the congruent melting of both phases.

Crystallography↗

Data and scripts associated with the manuscript "A Hydrogeophysical Framework to Assess Infiltration During a Simulated Ecosystem-Scale Flooding Experiment”

This package contains the data and scripts used in "A hydrogeophysical framework to assess infiltration during a simulated ecosystem-scale flooding experiment" (Adebayo et al., 2023). The Geophysics folder contains two subfolders containing Ground Penetrating Radar (GPR) and Electrical Resistivity Imaging (ERI) datasets acquired between August 23 and August 26, 2021. The GPR subfolder contains raw data (Tempest_Project.GPZ) and processed results using the Sensors and Software EKKO Project software. The ERI subfolder contains two additional subfolders named Static and Timelapse. The Static subfolder contains background resistivity datasets acquired before infiltration, both raw and inverted results using the ResIpy code. The Timelapse subfolder contains repeated resistivity datasets acquired during infiltration on two profiles, along with raw and inverted results using the ResIpy code. The Flow model folder contains ATS model simulation files. The Geophysics-informed subfolder contains simulation datasets for two profiles generated using information from the geophysics data. The National_database-informed subfolder contains simulation datasets for two profiles generated using information from a national soil database. Each subfolder contains initial simulation results, multiple ensembles, and final simulation files. The Sensitivity_analysis folder contains the observation files exported from the flow model, notebooks used in running the code, and sensitivity analysis results showing the sensitivity of different parameters over a 48-hour period. We used mutual information-based global sensitivity analysis for the sensitivity analysis, following Jiang et al., 2022. This study shows a novel approach that integrates geophysical data with hydrological modeling to understand subsurface flow during coastal flooding.

54 ENVIRONMENTAL SCIENCES↗

Soil Water Retention and Hydraulic Conductivity Data and Model at Trail Creek in Taylor River Watershed, Colorado 2024-2025

This data package includes soil water retention and hydraulic conductivity data and model fitting results from measurements of ex-situ soil samples and in-situ soil sensors near Trail Creek. Soil water retention curves (SWRC) characterize soil water content as a function of soil water potential. SWRC depends on soil texture and pore structure and can be used to describe the constraints on biogeochemical processes in terms of soil water availability. In this data package, the sample identification follows the format TR-X-Y, where TR refers to Trail Creek, X is the treatment block identifier, and Y is the location identifier. Specifically, TR-ASCC1 is the control treatment block under the Adaptive Silviculture for Climate Change (ASCC) project, and TR-ASCC2 is the clear-cut treatment block. TR-ASCC-EHSn is associated with ecohydrology sites under the East-Taylor Watershed Community Observatory Sites directory, and TR-ASCC-ERTn (upslope n=1) are ecohydrology sites along the electrical resistivity tomography transects. The sample and location information can be found in metadata.csv, and the data from the soil sensors will be included in a future data version when the observation period becomes sufficiently long for data analysis. Sampling and Measurements Each sample falls into one of the two sampling methods – (1) intact cores or (2) soil sensors – and one of the two measurement methods – (a) laboratory or (b) in-situ. The intact cores were measured using the laboratory methods, which include measurements of soil water potential (HYPROP & WP4C, METER), saturated (KSAT, METER) and unsaturated hydraulic conductivity (HYPROP). The in-situ method uses a pair of co-located soil sensors to measure volumetric water content (TEROS12, METER) and soil water potential (TEROS21, METER), and the hydraulic conductivity was not measured. In comparison, the laboratory methods progress from full saturation to dry conditions, and the in-situ method includes both dry-to-wet and wet-to-dry cycles. The sampling and measurement methods for each sample can be found in metadata.csv, and more information about the measurements is detailed in the Methods section below. Models Retention and hydraulic conductivity data were fitted with four van-Genuchten-type models (specified by “model_name” column in the files): (1) traditional constrained van Genuchten model (“vG_constrained”), (2) traditional unconstrained van Genuchten model (“vG_unconstrained”), (3) PDI-variant of the constrained van Genuchten model (“vG_constrained_PDI”), and (4) PDI-variant of the unconstrained van Genuchten model (“vG_unconstrained_PDI”). The difference between the constrained (1: n) and the unconstrained (2: n, m) van Genuchten models is the number of pore-size distribution parameters in the model equations, giving the unconstrained model more degrees of freedom when fitting the data. Between the traditional and the PDI-variant models, model fitting differs the most at the dry end of the measurements. The traditional models allow infinite suction at the residual water content (water content does not drop below residual water content), and the PDI-variant models enforce a soil water potential value of pF=6.8 (~ -630 MPa) at oven-dryness (water content reaches 0). The inclusion of the van-Genuchten-type models is due to their common application. If other retention models are required, users can access the data in data.csv for further data fitting. More information about the models can be found in the Methods section below. Fitting Tasks The model fitting can be categorized into three levels of tasks (specified by “fitting_task” column in the files). Level 1 (“fit_retention”) only includes retention data fitting (the only level available for the in-situ method). Level 2 (“fit_retention_conductivity”) includes both retention and hydraulic conductivity data fitting, and the saturated hydraulic conductivity (Ks, a parameter of the hydraulic conductivity functions) is fixed by the measurements from KSAT. Level 3 (“fit_retention_conductivity_Ks”) also includes both retention and hydraulic conductivity data fitting, but Ks is a fitted parameter without the constraints from KSAT measurements. Among the same retention models (e.g. vG_constrained models of the same sample), level 1 should produce the best retention data fitting. Level 2 should have the highest misfit of the retention and hydraulic conductivity data, because the retention and hydraulic conductivity functions share common model parameters, and the unsaturated hydraulic conductivity (HYPROP) data fitting is subject to Ks measured independently by KSAT. Level 3 should have mid-level misfits of the retention and hydraulic conductivity data. While level 3 fits the hydraulic conductivity data better than level 2, the fitted Ks value might be unreasonable due to the lack of constraints at the wet end of the measurements. General recommendation when using this data package: (1) Choice of sampling methods: Intact cores might suffer from sample gaps that would lead to overestimation of Ks (sample gaps can be inferred from the “soil_sample_volume” column in metadata.csv when the value is < 249). In-situ method has higher uncertainty in characterizing the wet end of the SWRC because of sensor limitations and the difficulty in reaching full saturation under natural conditions. (2) Choice of fitting tasks: When only retention data is needed, level 1 (“fit_retention”) should be prioritized. When both retention and hydraulic conductivity data are needed, level 2 (“fit_retention_conductivity”) could be prioritized. (3) Choice of models: This could depend on what the downstream models call for. If no specific model is required, model misfit could be used as a ranking criterion. Model misfit values in terms of RMSE can be found in model_parameters.csv. The following files are included in this data package: (1) metadata.csv – This file includes the general information of each sample, including location (description, geocoordinates, elevation), sampling and measurements details (method, depth, time or period, volume, instruments), and soil physical properties (bulk density, saturated hydraulic conductivity, only applicable to physical soil samples). (2) data.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity data of each sample. Column “instrument” specifies the instrument (HYPROP, WP4C, or TEROS) used to perform the measurements. (3) model_fit.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity fitted from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the variable does not apply to that fitting task. (4) model_parameters.csv – This file includes the fitted model parameters, model misfits, and conventional water content thresholds (field capacity and wilting point) from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the parameter does not apply to that model and/or that fitting task. (5) data_Ks.csv – This file includes the saturated hydraulic conductivity measurements from KSAT. (6) /figure/*.png – This folder includes three quick visualizations of the data, retention model fitting results and misfits, and hydraulic conductivity model fitting results, misfits, and parameters. The model fitting results are separated by samples and fitting tasks and colored by models. Zoom-in required. (7) /hyprop/*.bdhx – This folder includes proprietary hyprop files that require the free Labros SoilView-Analysis (METER) to open. Users can explore data fitting using other retention models (i.e. Brooks-Corey, Fredlund-Xing, Kosugi, bimodal models). Be aware that Ks value is pre-entered under “Fitting tab, Conductivity functions parameters” for level 2 fitting. If the value is lost, please refer to metadata.csv under “Ks” column. (8) Six file-level metadata that summarize file, header, column, and variable information of all files. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

EARTH SCIENCE > LAND SURFACE > SOILS↗

Soil Water Retention and Hydraulic Conductivity Data and Model at Snodgrass Mountain in East River Watershed, Colorado 2020-2025

This data package includes soil water retention and hydraulic conductivity data and model fitting results from measurements of ex-situ soil samples and in-situ soil sensors at Snodgrass Mountain. Soil water retention curves (SWRC) characterize soil water content as a function of soil water potential. SWRC depends on soil texture and pore structure and can be used to describe the constraints on biogeochemical processes in terms of soil water availability. In this data package, the sample identification follows the format SG-X-Y, where SG refers to Snodgrass Mountain, X is the location identifier, and Y is the depth identifier at the same X (shallow Y=1). Specifically, SG-EHS is associated with ecohydrology sites under the East-Taylor Watershed Community Observatory Sites directory, and SG-ERTn (upslope n=1) are points along the Snodgrass electrical resistivity tomography transect not associated with the existing site names in the directory. The sample and location information can be found in metadata.csv. Sampling and Measurements Each sample falls into one of the three sampling methods – (1) intact cores, (2) repacked samples, or (3) soil sensors – and one of the two measurement methods – (a) laboratory or (b) in-situ. Both intact cores and repacked samples were measured using the laboratory methods, which include measurements of soil water potential (HYPROP & WP4C, METER), saturated (KSAT, METER) and unsaturated hydraulic conductivity (HYPROP). The in-situ method uses a pair of co-located soil sensors to measure volumetric water content (TEROS12, METER) and soil water potential (TEROS21, METER), and the hydraulic conductivity was not measured. In comparison, the laboratory methods progress from full saturation to dry conditions, and the in-situ method includes both dry-to-wet and wet-to-dry cycles. The sampling and measurement methods for each sample can be found in metadata.csv, and more information about the measurements is detailed in the Methods section below. Models Retention and hydraulic conductivity data were fitted with four van-Genuchten-type models (specified by “model_name” column in the files): (1) traditional constrained van Genuchten model (“vG_constrained”), (2) traditional unconstrained van Genuchten model (“vG_unconstrained”), (3) PDI-variant of the constrained van Genuchten model (“vG_constrained_PDI”), and (4) PDI-variant of the unconstrained van Genuchten model (“vG_unconstrained_PDI”). The difference between the constrained (1: n) and the unconstrained (2: n, m) van Genuchten models is the number of pore-size distribution parameters in the model equations, giving the unconstrained model more degrees of freedom when fitting the data. Between the traditional and the PDI-variant models, model fitting differs the most at the dry end of the measurements. The traditional models allow infinite suction at the residual water content (water content does not drop below residual water content), and the PDI-variant models enforce a soil water potential value of pF=6.8 (~ -630 MPa) at oven-dryness (water content reaches 0). The inclusion of the van-Genuchten-type models is due to their common application. If other retention models are required, users can access the data in data.csv for further data fitting. More information about the models can be found in the Methods section below. Fitting Tasks The model fitting can be categorized into three levels of tasks (specified by “fitting_task” column in the files). Level 1 (“fit_retention”) only includes retention data fitting (the only level available for the in-situ method). Level 2 (“fit_retention_conductivity”) includes both retention and hydraulic conductivity data fitting, and the saturated hydraulic conductivity (Ks, a parameter of the hydraulic conductivity functions) is fixed by the measurements from KSAT. Level 3 (“fit_retention_conductivity_Ks”) also includes both retention and hydraulic conductivity data fitting, but Ks is a fitted parameter without the constraints from KSAT measurements. Among the same retention models (e.g. vG_constrained models of the same sample), level 1 should produce the best retention data fitting. Level 2 should have the highest misfit of the retention and hydraulic conductivity data, because the retention and hydraulic conductivity functions share common model parameters, and the unsaturated hydraulic conductivity (HYPROP) data fitting is subject to Ks measured independently by KSAT. Level 3 should have mid-level misfits of the retention and hydraulic conductivity data. While level 3 fits the hydraulic conductivity data better than level 2, the fitted Ks value might be unreasonable due to the lack of constraints at the wet end of the measurements. General recommendation when using this data package: (1) Choice of sampling methods: Intact cores and in-situ soil sensors could be prioritized because these sampling methods are less destructive. While the repacked samples were packed to the target bulk density (estimated post-sampling, when sample volume was known), these samples had altered pore structures. Nevertheless, intact cores might suffer from sample gaps that would lead to overestimation of Ks (sample gaps can be inferred from the “soil_sample_volume” column in metadata.csv when the value is < 249). In-situ method also has higher uncertainty in characterizing the wet end of the SWRC because of sensor limitations and the difficulty in reaching full saturation under natural conditions. (2) Choice of fitting tasks: When only retention data is needed, level 1 (“fit_retention”) should be prioritized. When both retention and hydraulic conductivity data are needed, level 2 (“fit_retention_conductivity”) could be prioritized. (3) Choice of models: This could depend on what the downstream models call for. If no specific model is required, model misfit could be used as a ranking criterion. Model misfit values in terms of RMSE can be found in model_parameters.csv. The following files are included in this data package: (1) metadata.csv – This file includes the general information of each sample, including location (description, geocoordinates, elevation), sampling and measurements details (method, depth, time or period, volume, instruments), and soil physical properties (bulk density, saturated hydraulic conductivity, only applicable to physical soil samples). (2) data.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity data of each sample. Column “instrument” specifies the instrument (HYPROP, WP4C, or TEROS) used to perform the measurements. (3) model_fit.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity fitted from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the variable does not apply to that fitting task. (4) model_parameters.csv – This file includes the fitted model parameters, model misfits, and conventional water content thresholds (field capacity and wilting point) from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the parameter does not apply to that model and/or that fitting task. (5) data_Ks.csv – This file includes the saturated hydraulic conductivity measurements from KSAT. (6) /figure/*.png – This folder includes three quick visualizations of the data, retention model fitting results and misfits, and hydraulic conductivity model fitting results, misfits, and parameters. The model fitting results are separated by samples and fitting tasks and colored by models. Zoom-in required. (7) /hyprop/*.bdhx – This folder includes proprietary hyprop files that require the free Labros SoilView-Analysis (METER) to open. Users can explore data fitting using other retention models (i.e. Brooks-Corey, Fredlund-Xing, Kosugi, bimodal models). Be aware that Ks value is pre-entered under “Fitting tab, Conductivity functions parameters” for level 2 fitting. If the value is lost, please refer to metadata.csv under “Ks” column. (8) Six file-level metadata that summarize file, header, column, and variable information of all files. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

EARTH SCIENCE > LAND SURFACE > SOILS↗

Influence of pre-existing defects on thermal transport in nuclear graphite

Nuclear graphite is a critical material in high-temperature nuclear reactors due to its superior thermal and mechanical properties. The manufacturing process leaves multi-scale ‘pre-existing’ defects that can affect thermal transport characteristics. Because these defects are remnant of graphitization temperature, they cannot be thermally annealed. This study employs a non-thermal electron wind force (EWF) annealing technique to avoid this obstacle. 2 min of EWF treatment of the as-received graphite IG-110 at temperatures below 100 °C led up to 67% increase in thermal diffusivity and ~ 35% decrease in electrical resistivity in average. Differential scanning calorimetry also showed similar outcome for specific heat. X-ray diffraction characterization was performed by fitting a bi-modal crystallite size distribution model to reveal the enhancement in crystallinity after the EWF treatment. The findings emphasize the potential of EWF annealing for optimizing thermal performance in nuclear graphite and its implications for reactor efficiency and safety.

Annealing↗

Determination of Ground Subsidence Around Snow Fences in the Arctic Region

In this study, we analyzed the effects of snow cover changes caused by snow fences (SFs) installed in 2017 in the Alaskan tundra to examine ground subsidence. Digital surface model data obtained through LiDAR-based remote sensing in 2019 and 2022, combined with a field survey in 2021, revealed approximately 0.2 m of ground subsidence around the SF. To investigate the relationship between SF-induced snow cover changes and ground subsidence, geophysical methods, electrical resistivity tomography (ERT) and ground-penetrating radar (GPR), were applied in 2023 to analyze subsurface characteristics. The increased snow cover due to the SF-enhanced insulation, delaying the penetration of winter cold into the subsurface. This delay caused subsurface temperatures to decrease more slowly, melting the upper permafrost and increasing the thickness of the active layer. ERT and GPR surveys well delineated the boundary between the active layer and permafrost, confirming that the increased snow cover thickened the active layer. This thickening led to the melting of pore ice, causing water runoff and ground compaction, which resulted in subsidence. The runoff also formed channels flowing eastward over the SF. This study highlights how changes in snow cover can influence active layer properties, leading to localized environmental changes and ground subsidence.

54 ENVIRONMENTAL SCIENCES↗

Kinetic effects of self-organization in low-temperature magnetized plasmas (Final Report for DE-SC0019045: 9/1/2018-8/31/2019)

The research goal of this Early Career Research Program project is to advance the science of low temperature magnetized plasmas using first-principles kinetic, e.g., solving the Boltzmann equation, models. A better understanding of the plasma transport properties, such as electrical resistivity and thermal conductivity must be obtained to better control and design magnetized plasma sources. A key physical phenomenon in low-temperature magnetized plasmas is the self-organization of plasma flows, e.g., coherent plasma structures and transition between different discharge modes. Understanding the physics of coherent plasma structures has been identified as one of the four important frontier topics in a recent workshop by the Office of Fusion Energy Science. These self-emerging plasma patterns results from the nonlinear coupling between plasma constituents (ions, electrons, and neutral atoms), electromagnetic fields, and materials. The physics of low-temperature magnetized plasmas is particularly complex because (i) the collisionless instabilities affect collisional phenomena (ionization, transport, etc.) and vice versa and (ii) the presence of materials (sheath, electron injection, etc.) influences the bulk plasma properties in low-temperature plasma (LTP) devices. Computational models of these plasma flows remain challenging because the plasma density can vary several orders of magnitudes, a wide range of temporal and spatial scales must be resolved, the phenomena are inherently three-dimensional, and various physical processes, such as wall interaction, instabilities, inelastic collisions, etc., must be simultaneously and self-consistently taken into account. Understanding the fundamental transport mechanisms in cross-field configurations enables additional controllability of plasma properties and electron energy distribution functions (EEDFs).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Project Plan: Salt in Situ Heater Test

This project plan gives a high-level description of the US Department of Energy Office of Nuclear Energy (DOE-NE) Spent Fuel and Waste Disposition (SFWD) campaign in situ borehole heater test project planned for the Waste Isolation Pilot Plant (WIPP) site, titled the Brine Availability Test in Salt (BATS). BATS is the first stage in a planned sequence of tests to bolster the technical basis for disposal of heat generating waste in salt. This plan provides an overview of the schedule and responsibilities of the parties involved. This project is a collaborative effort by Sandia, Los Alamos, and Lawrence Berkeley National Laboratories to execute a series of small-diameter borehole heater tests in salt for the DOE-NE SFWD campaign. Design of a heater test in salt at WIPP has evolved over several years. The experiment has begun in January 2020 and the first phase will continue for several months with the possibility for follow on testing. BATS comprises a suite of modular tests, which consist of a group of adjacent horizontal boreholes in the wall of drifts at WIPP. Each test is centered around a packer-isolated heated borehole (12.2 cm [4.81 diameter) containing equipment for water-vapor collection and borehole closure monitoring, surrounded by smaller-diameter (up to 5.3 cm [2.11 diameter) satellite observation boreholes. Observation boreholes contain grouted-in temperature sensors, electrical resistivity tomography (ERT) sensors, and fiber optics; packer-isolated tracer release and sampling intervals; and acoustic emission (AE) piezoelectric sensors. A larger-diameter (12.2 cm [4.81) satellite borehole includes sorel and salt cement plugs, as part of an engineered barrier sealing test. The first two tests, to be implemented in parallel, are heated (target borehole wall temperature of 120 °C) and unheated, with similar arrays of observation borehole monitoring changes. Follow-on tests will be designed using information gathered from the first two tests, and may be conducted at other borehole wall temperatures, use multiple observation boreholes, and may include different measurement types and test designs. This 2020 update of the original 2018 project plan satisfies DOE-NE Spent Fuel and Waste Science and Technology (SFWST) milestone M3SF-205N010303034, as part of the SNL "Salt Disposal R&D" work package.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transient voltage-reversal in transformers with multiple secondary coils

By using a transformer with multiple secondary coils, a single unipolar power source can drive multiple loads that have different steady-state operating-voltage requirements. We show that, during initial turn-on, a transient voltage that is opposite in sign to the operating voltage can be induced in one or more of the secondary coils. This is because the surging currents in the coils during turn-on produce a strong inductive interaction between all the coils. In a particular secondary coil, the voltage induced by a neighboring secondary can be larger, and opposite in sign to, the voltage directly induced by the primary coil. The effect is transient because, when the secondary circuits reach their steady-state operating currents, they no longer couple inductively to each other. We also show that, during the turn-on period, the voltage induced in a secondary coil can be significantly larger than its steady-state voltage. These transient effects are controlled by the values of the "coil-coupling" parameters, which are functions of the transformer geometry and of the magnetic permeability and electrical resistivity of the materials used. The results are derived from the circuit equations, and verified using PSpice simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Technology Development and Field Monitoring in nZEB - US Country report IEA HPT Annex 49 Task 3

The International Energy Agency (IEA) Heat Pumping Technologies (HPT) Annex 49, “Design and Integration of Heat Pumps for Nearly Zero Energy Buildings,” deals with the application of heat pumps (HPs) as a core component of the HVAC system for nearly or net-zero energy buildings. This report covers the Task 3 activities of the US team. Three institutions are involved on the US team and have worked on the following projects. 1) Oak Ridge National Laboratory (ORNL) summarized development activities since the conclusion of IEA HPT Annex 40 for several integrated HP (IHP) systems - electric ground-source IHP and air-source IHP versions and engine-driven AS-IHP version. 2) The University of Maryland partnered with ORNL and Blue Bear Management to develop a personal cooling device called RoCo that can provide personalized conditioned air to occupants in inadequately or unconditioned environments. With RoCo, building facility management can elevate the HVAC thermostat settings without compromising occupants’ thermal comfort. Researchers have found that a 4°F increase in thermostat settings can save 12–30% energy savings. Therefore, RoCo is a promising technology that can help reduce building energy consumption and facilitate achievement of net-zero energy building performance. 3) The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net-Zero Energy Residential Test Facility. Two air-source split-system HPs were installed in a residential, net-zero energy home that was constructed as a laboratory on the NIST campus in Gaithersburg, Maryland. The first HP was a two-stage, 7 kW (2 ton), 15.8 seasonal energy efficiency ratio (SEER), 9.05 heating seasonal performance factor (HSPF) conventionally ducted system; the second HP was a variable-speed, 10.6 kW (3 ton), 14 SEER, 8.35 HSPF, high-velocity ducted system. These two systems operated side by side, using separate supply ducts and a common return duct, on a weekly alternating schedule to condition the home that was operated with very consistent simulated thermal loads. The team wanted to determine whether the high-velocity system could provide comparable energy-use efficiency to the conventional system. The results of this study showed that it did meet the required loads and had slightly greater efficiency; the average cooling coefficient of performance (COP) was (0.40 ± 0.11) higher, and the average heating COP was statistically equal. A new firmware was provided at the end of the heating season that greatly improved the performance of the high-velocity system; its average heating COP went from (1.8 ± 0.9) to (2.5 ± 1.1) at a 95% confidence level. The new firmware heating COP averaged (1.05 ± 0.23) higher than the old firmware over the same outdoor temperatures. The defrost performance is very different for these two systems, yet they consumed equivalent energy per HDD. The conventional system uses a timed-initiate, temperature-terminate algorithm with auxiliary electric resistive heating, whereas the high-velocity system uses calculated evaporator parameters with a hot-gas bypass before a full reverse-cycle defrost with no supplementary resistive heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fast Computational Algorithms for Partial Differential Equations and Uncertainty Quantifications

This project concerned the construction, testing and analysis of computational algorithms for solving parameterized and stochastic partial differential equations. The study and understanding of equations of this type is of fundamental importance in numerous engineering and scientific applications. Examples include simulation of plasma dynamics in models of electric propulsion and nuclear fusion, simulation of multiphase flows, such as the flow of water, gas and oil in reservoirs, and structural analysis of the dependence of structures on materials. Parametrization is used in such settings when properties of the models such as viscosity of fluids or electric resistivity of materials are not precisely understood and instead are treated as random variables. The resulting solutions are themselves random, and having such solutions will enable engineers to use probabilistic methods to assess the likelihood of events, for example, whether a pollutant in a liquid will exceed a limit, and to use such analyses to develop ways to ensure positive outcomes. Construction of accurate (high resolution) computational solutions is expensive, requiring significant computer time and computational resources, and there is need to reduce computational cost to make simulation useful and effective. The aim of the project was to construct algorithms to efficiently compute surrogate solutions to parameterized problems to allow for efficient and accurate simulation. The technical approach used focused on two related strategies, based on rank-reduction methods and reduced-order models. These methods construct surrogate solutions of parameter-dependent models by projection or interpolation into low-dimensional approximation spaces. Cost savings are achieved if the low-dimensional spaces can be identified and constructed efficiently and if the resulting low-dimensional algebraic systems can be solved cheaply. Accomplishments include: Theoretical and empirical demonstration of the effectiveness of fast multigrid solution strategies for computing low-rank representations of parameter-dependent solutions to discrete partial differential equations, including the first proof establishing so-called textbook convergence properties for low-rank methods. Development of efficient solution algorithms for solving nonlinear parameter-dependent partial differential equations used in models of fluid dynamics. Developent of efficient algorithms for low-rank representation of solutions of time-dependent simulations of fluid dynamics using multi-dimensional tensor representations of solutions.

97 MATHEMATICS AND COMPUTING↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of a Potential Groundwater Tracer Test in the Ringold Upper Mud Aquifer at the 100-H Area of the Hanford Site

This document presents an evaluation of a potential groundwater tracer test in the uppermost RUM (Ringold Formation member of Wooded Island – upper mud unit) aquifer in the 100-H Area of the Hanford Site. The results from field electrical resistivity tomography (ERT) investigations, numerical flow and transport (F&T) modeling, coupled ERT-F&T model simulations, and laboratory resin experiments provide the technical basis for evaluating tracer test scenarios that minimize impacts to the 100-HX pump and treat (HX P&T) operations, and maximize hydrologic data acquisitions including the use of advanced surface geophysical techniques for monitoring tracer transport.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Damage Detection and Electrical Performance Impact of Flat-Flexible Circuits

Flat-flexible circuits or ‘flex circuits’ have varied applications in electronics and in explosive detonation systems. They pose advantages over conventional coaxial cables in their ability to fit into small mechanical envelopes and routings. A typical flex circuit is composed of a laminated assembly of multiple layers of conductor and dielectric materials. Copper, because of its high electrical conductivity, is one of the primary materials used in flex circuit conductors. The conductor must maintain structural integrity and electrical continuity when the flexible circuit is bent during processing or to fit an application envelope. Under some strain conditions a cable may have degraded electrical performance even though visible damage may not be evident. Dislocation density can increase by mechanisms such as dislocation forest hardening, where gliding dislocations in primary slip planes get pinned at obstacles and form Frank-Read sources. Dislocation density increases within the conductor layers may impact electrical resistivity but would not necessarily result in visible mechanical failure. In some detonation applications, such as for building implosion for demolition, the time for signal transmission and voltage used for firing detonators can be critical. If the resistance in a single flex cable within a building demolition array is too high, the resultant demolition shape may be asymmetric, leading to unplanned damage to nearby structures and potential hazards to public safety. This study will apply non-destructive evaluation techniques to evaluate the detectability of damage accumulation in flat, flexible copper-conductor cables and discuss potential implications to their practical use.

42 ENGINEERING↗

Continuous Particle Monitoring and Removal for Molten Chloride CSP Systems

This report describes the technologies that were developed as part of the Continuous Particle Monitoring and Removal for Molten Chloride CSP Systems project that was funded by the EERE Solar Energy Technologies Office during FY2021. This project consisted of two main tasks: (1) the development electrical resistance tomography (ERT) sensors to provide particle sensing capabilities for CSP-relevant molten chloride salts, and (2) the development of vortex separation technologies to enable efficient removal of particles from the salt. Both of these tasks are crucial because, although the Gen3 CSP chloride heat transfer fluid is inexpensive and can achieve high temperatures, major issues with erosion corrosion and clogging can arise from the presence of MgO particles within the salt. The particle monitoring and removal technologies were both demonstrated over the course of this project. The ERT sensors were able to achieve their performance targets by providing accurate particle concentration measurements over a range from 0.0 to 8.0 wt%. The vortex separators were able to demonstrate separation of particles from molten salt streams, but the separation efficiencies were lower than the targeted level of 90%. With further development and deployment, these technologies will ultimately help to enable successful long-term operations of CSP systems that make use of high-temperature chloride salts.

14 SOLAR ENERGY↗

Creation of Laboratory-scale Testbed for Autonomous Monitoring and Control of Subsurface Systems

This report describes the results of an LDRD project aiming to develop a laboratory-scale testbed for autonomous subsurface monitoring and control systems. Modifications were made to an existing polyaxial loading frame to incorporate electrical resistivity tomography (ERT) and acoustic emission (AE) monitoring systems. This allows engineered subsurface processes to be studied under realistic temperatures and stresses in a scaled-down laboratory environment with similar monitoring systems as are deployed in field-scale systems. The paper outlines some challenges that were faced in implementing the ERT system at the laboratory scale and the solutions that were devised. Results are shown from two demonstration tests—one focusing on the ERT system, and one focusing on the AE system.

42 ENGINEERING↗