Terminal System for Photovoltaic Arrays

Quick-connect terminal system provides electrical contact and physical alinement between adjacent photovoltaic modules. Dual-ended plugs connect adjacent modules; single-ended plugs connect bus cables. No tools required to insert plugs and no live terminals exposed before, during, or after connection.

Maloney, T. J.↗

Other Industrial Aids

In another industrial spinoff, O. Z. Gedney Co.,Terryville, Conn., found the answer to a problem in a NASA Tech Brief describing research in adhesive bonding for the Space Shuttle. Gedney, which makes electrical fittings for industrial plants, was developing a new "fire stop," a device that prevents the spread of fire through holes where cables and pipes penetrate fire barriers in buildings. The company wanted to bond a metal disc on the fire stop to a layer of "instumescent" material, material that swells under heat and fills the gap caused by melted cable insulation, thus blocking passage of fire and smoke. At the company's request, NASA supplied a technical information package which identified the best adhesive and the proper bonding technique. The fire-stop fitting is now in production.

Source record↗

Analysis of Pull Force Test Results for Crimped Connections

Crimped electrical contacts are reliable when strict process controls are followed during manufacturing and accompanied by continuous process verification through pull force testing. Cable and wire harness assemblies’ standards are developed and refined over time to provide the minimum pull force that a crimp contact must meet before it breaks from the wire. However, in practice the failures occur at a much higher tensile strength than the minimum required. The first section of this paper reviewed 780 pull force test results provided by NASA Centers that were collected and analyzed to determine how the data compare to NASA’s pre-existing requirements from the cable/harness standards NASA-STD-8739.4 and IPC/WHMA-A-620B-S. The measured tensile strength of most of the contact/conductor pairs (i.e., Contact/Wires or C/W) exceeded the minimum pull force values of NASA-STD-8739.4 and IPC/WHMA-A-620 standards by at least 100%. The C/W pair samples’ tensile strength values followed a normal distribution with an average tensile strength value that was at least 182% of the minimum requirement, and all the samples analyzed passed the pull force testing. In addition, the 95% confidence interval of the average tensile strength distributions for several C/W pairs was determined and plotted as error bars to show that the C/W pairs will meet and surpass the requirements. The frequency of pull force testing can be problematic for projects because of the cost and availability of spare contacts for the destructive test. It is possible to reduce the frequency of pull force testing if at the beginning of the production run, the conditions of the crimp tool and materials are verified, and the settings of the tool remain unchanged throughout the process. However, the project needs to understand and evaluate the impact to risk from reducing the frequency of testing prior to implementing process changes.

Alejandra Constante↗

Analysis of Pull Force Test Results for Crimped Connections

Crimped electrical contacts are reliable when strict process controls are followed during manufacturing and accompanied by continuous process verification through pull force testing. Cable and wire harness assemblies’ standards are developed and refined over time to provide the minimum pull force that a crimp contact must meet before it breaks from the wire. However, in practice the failures occur at a much higher tensile strength than the minimum required. The first section of this paper reviewed 780 pull force test results provided by NASA Centers were collected and analyzed to determine how the data compares to NASA’s pre-existing requirements from the cable/harness standards NASA-STD-8739.4 and IPC/WHMA-A-620B-S. The measured tensile strength of most of the contact/conductor pairs (i.e. Contact/Wires or C/W) exceeded the minimum pull force values of NASA-STD-8739.4 and IPC/WHMA-A-620 standards by at least 100 %. The tensile strength samples of the C/W pairs values followed a normal distribution with an average tensile strength value that was at least 182 % of the minimum requirement, and all the samples analyzed passed the pull force testing. In addition, the 95 % confidence interval of the average tensile strength distributions for several C/W pairs was determined and plotted as error bars to show that there is good likelihood to observe C/W pair normal distribution with a 95 % confidence interval that will meet and surpass the standard requirements. The frequency of pull force testing can be problematic for projects because of the cost and availability of spare contacts for the destructive test. It could be possible to reduce the frequency of pull force testing if at the beginning of the production run, the conditions of the crimp tool and materials are verified, and the settings of the tool remain unchanged throughout the process. However, the project must evaluate the impact to risk from reducing the frequency of testing.

Crimped connections↗

Multiaxis, Lightweight, Computer-Controlled Exercise System

The multipurpose, multiaxial, isokinetic dynamometer (MMID) is a computer-controlled system of exercise machinery that can serve as a means for quantitatively assessing a subject s muscle coordination, range of motion, strength, and overall physical condition with respect to a wide variety of forces, motions, and exercise regimens. The MMID is easily reconfigurable and compactly stowable and, in comparison with prior computer-controlled exercise systems, it weighs less, costs less, and offers more capabilities. Whereas a typical prior isokinetic exercise machine is limited to operation in only one plane, the MMID can operate along any path. In addition, the MMID is not limited to the isokinetic (constant-speed) mode of operation. The MMID provides for control and/or measurement of position, force, and/or speed of exertion in as many as six degrees of freedom simultaneously; hence, it can accommodate more complex, more nearly natural combinations of motions and, in so doing, offers greater capabilities for physical conditioning and evaluation. The MMID (see figure) includes as many as eight active modules, each of which can be anchored to a floor, wall, ceiling, or other fixed object. A cable is payed out from a reel in each module to a bar or other suitable object that is gripped and manipulated by the subject. The reel is driven by a DC brushless motor or other suitable electric motor via a gear reduction unit. The motor can be made to function as either a driver or an electromagnetic brake, depending on the required nature of the interaction with the subject. The module includes a force and a displacement sensor for real-time monitoring of the tension in and displacement of the cable, respectively. In response to commands from a control computer, the motor can be operated to generate a required tension in the cable, to displace the cable a required distance, or to reel the cable in or out at a required speed. The computer can be programmed, either locally or via a remote terminal, to support exercises in one or more of the usual exercise modes (isometric, isokinetic, or isotonic) along complex, multiaxis trajectories. The motions of, and forces applied by, the subject can be monitored in real time and recorded for subsequent evaluation. Through suitable programming, the exercise can be adjusted in real time according to the physical condition of the subject. The remote- programming capability makes it possible to connect multiple exercise machines into a network for supervised exercise by multiple subjects or even for competition by geographically dispersed subjects.

Haynes, Leonard↗

Fork Union EPC Installation Observation Report

On June 22nd and 23rd, a representative from Savannah River National Lab (SRNL) traveled to the Fork Union substation in Fork Union, Virginia (owned and operated by Dominion Energy) to observe the installation, calibration, and commissioning of three Electric Phenomena Cluster (EPC) sensors. The installation in its entirety included the physical securing of the EPC sensors by Dominion Energy, fiber optic cable (furnished by SmartSenseComm) being run in conduits and cable trays from the EPC sensor to the Optical Processing Unit (OPU) located in the substation switch house. The location of the EPC sensors, OPU, and cable routing can be seen in the figures included.

47 OTHER INSTRUMENTATION↗

Detecting Anomalies for Fire Prevention in Distribution Systems: Challenges and Analytical Techniques

Electric utilities in California have historically been linked to up to 10% of wildfires. To mitigate this risk, Southern California Edison has invested significantly in wildfire prevention strategies, including undergrounding cables and enhancing equipment inspections. This article explores a novel approach to fire prevention by detecting anomalies in the distribution system that may indicate potential fire hazards. The focus is on identifying arcing conditions through high-resolution point-on-wave (POW) measurements. Arcing, a precursor to fires, is challenging to detect due to its subtle transients and complex system topology. The article discusses the use of advanced signal processing and machine learning techniques, such as spectral correlation function and discrete wavelet transform, to extract features from POW data and accurately identify arcing events. The study demonstrates a high accuracy rate in detecting arcing, paving the way for improved fire prevention measures in electric distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Variational data augmentation for a learning-based granular predictive model of power outages

As the trend in climate change continues, extreme weather events are expected to occur with increasing frequency and severity and pose a significant threat to the electric power infrastructure. Regardless of the efforts a utility puts towards hardening the grid, storm-induced damage to the utility assets such as cables and distributed energy resources (DERs) that are particularly vulnerable to such events is unavoidable. Access to a highly granular, in space and time, outage forecasting tool with long lead times (i.e., days ahead) will enhance the efficiency of service restoration efforts. Here, in this study, we propose to develop and implement a multi-model framework as an operational tool based on a granular and multi-day outage forecasting model using operational numerical weather prediction model forecasts and detailed component outage information. An innovative two-layered recurrent neural network, i.e., a long-short-term-memory (LSTM)-based variational autoencoder (VAE) framework and a sliding window are used to address the uneven distribution of different types of weather events and make better use of the time-series data. Case studies are performed to demonstrate the performance of the new framework.

54 ENVIRONMENTAL SCIENCES↗

Static Dissipative Cable Ties, Such as for Radiation Belt Storm Probes

An article, such as, but not limited to, a cable strap to wrap, support, or secure one or more wires or cables, is formed by cyclically heating and cooling and/or irradiating an article formed of a static dissipative ethylene tetrafluoroethylen (ETFE) resin, to reduce an electrical resistivity and/or to increase a tensile strength of the article.

Langley, Patrick T.↗

Extendible column can be stowed on drum

Column formed from a series of segments held together by an internal spring or cable can be coiled on a drum or extended into a rigid structure. This storable coil is useful in boring for soil samples and supporting electrical and optical sensors.

Holtz, G. M.↗

Spring control of wire harness loops

Negator spring control guides wire harness between movable and fixed structure. It prevents electrical wire harness loop from jamming or being severed as wire moves in response to changes in position of aircraft rudder. Spring-loaded coiled cable controls wire loop regardless of rudder movement.

Curcio, P. J.↗

Flex-Capsules for the Roman Space Telescope High Gain Antenna Gimbal

The Cable Wrap mechanism has been traditionally used for feeding power and telemetry through each gimbal actuator exiting at the gimbal output flange. Such a mechanism had often utilized round wire bundles or a multitude of single insulated conductors woven together flatwise to handle the angular rotation. Though flexible printed circuit board (PCB) is not a new technology, it was decided to implement it for the Roman Space Telescope (RST) High Gain Antenna Gimbal in an effort to improve reliability with consistency of manufacture and to save mass and minimize required volume. This paper provides a description of what we term Flex-Capsule (a similar vendor flight development is termed Twist Capsule), discusses the reasoning behind choosing a new engineering development over maintaining heritage, and includes commentary pertaining to life cycle analysis, electrical performance, and flexible PCB lubrication. Lessons learned from the design, analysis, and test campaign are also included. The conclusion is that benefits of pursuing the Flex-Capsule over heritage Cable Wrap have been realized.

twist capsule↗

Flex-Capsule for the Roman Space Telescope High Gain Antenna Gimbal

The Cable Wrap mechanism has been traditionally used for feeding power and telemetry through each gimbal actuator exiting at the Gimbal output flange. Such a mechanism had often utilized round wire bundles, or a multitude of single insulated conductors woven together flatwise to handle the angular rotation. Though flexible printed circuit board (PCB) is not a new technology, it was decided to implement it for the Roman Space Telescope (RST) High Gain Antenna Gimbal in an effort to improve reliability with consistency of manufacture and to save mass and minimize required volume. This paper provides a description of what we term Flex-Capsule (a similar vendor flight development is termed Twist Capsule), discusses the reasoning behind choosing a new engineering development over maintaining heritage, and includes commentary pertaining to life cycle analysis, electrical performance, and flexible PCB lubrication. Lessons learned from the design, analysis, and test campaign are also included. The conclusion is that benefits of pursuing the Flex-Capsule over heritage Cable Wrap have been realized.

twist capsule↗

Task 12 PV Sustainability - Mineral Resource Use Footprints of Residential PV Systems

Resource use intensity is often mentioned as one of the main characteristics of PV systems and PV electricity. Recently, the International Energy Agency published a report on the role of critical minerals in clean energy transitions. The Product Environmental Footprint pilot study on PV electricity quantified (among other environmental impacts) its abiotic depletion potential. So far, a comprehensive assessment of resource use impacts highlighting the different facets of its impacts is however lacking. For the first time, the resource use impacts of PV electricity are quantified simultaneously with four impact category indicators recommended or suggested by the Life Cycle Initiative hosted at UN Environment. The indicators cover distinctly different aspects of resource use, namely resource depletion with the Abiotic Depletion Potential, ultimate reserves (ADP UR ), economic resource scarcity with the Abiotic Depletion Potential, economic reserves (ADP ER ), resource quality with the Surplus Ore Potential, Ultimate Recoverable Resources (SOP URR ) and re-source criticality with the ESSENZ method. The resource use impacts caused from the generation of 1 kWh electricity with a residential scale photovoltaic (PV) system installed in Central Europe using mono- and multi-crystalline silicon panels and CdTe panels, respectively are quantified. The product system includes manufacture, use and end of life treatment (take back and recycling) of the PV panels, cabling, inverter and supporting structure, the supply chains of the raw materials and energy used in PV panel and inverter manufacture as well as transport logistics.

14 SOLAR ENERGY↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrical impedance of FCC

The electrical characteristics of FCC are investigated in the context of multiple transmission lines theory. Analytical expressions for the coefficients of capacitance of conductors in a single cable are obtained. Numerical values calculated with these expressions are in good agreement with experimental data. Crosstalk, attenuation constants and phase angles of the current and voltage in flat conductor cable are also calculated.

Liu, Y. S.↗

High-Frequency ac Power-Distribution System

Loads managed automatically under cycle-by-cycle control. 440-V rms, 20-kHz ac power system developed. System flexible, versatile, and "transparent" to user equipment, while maintaining high efficiency and low weight. Electrical source, from dc to 2,200-Hz ac converted to 440-V rms, 20-kHz, single-phase ac. Power distributed through low-inductance cables. Output power either dc or variable ac. Energy transferred per cycle reduced by factor of 50. Number of parts reduced by factor of about 5 and power loss reduced by two-thirds. Factors result in increased reliability and reduced costs. Used in any power-distribution system requiring high efficiency, high reliability, low weight, and flexibility to handle variety of sources and loads.

Hansen, Irving G.↗

Shrink-Fit Solderable Inserts Seal Hermetically

Shrink-fit stainless-steel insert in aluminum equipment housing allows electrical connectors to be replaced by soldering, without degrading hermeticity of housing or connector. Welding could destroy electrostatic-sensitive components and harm housing and internal cables. Steel insert avoids problems because connector soldered directly to it rather than welded to housing. Seals between flange and housing, and between connector and flange resistant to leaks, even after mechanical overloading and thermal shocking.

Croucher, William C.↗