Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Influence of minor Ce additions on magnetic and electrical properties in Fe–6.5 wt. % Si alloy

Fe–6.5 wt. % Si alloys exhibit lower core loss at higher frequency than the dominating electrical steel containing 3.2% Si due to its lower magneto-crystalline anisotropy energy (MAE) and higher electrical resistivity. However, compared to nanocrystalline and amorphous soft-magnetic materials, 6.5% Si steel, although being cost effective and having high saturation magnetization, still has much to improve, especially with respect to MAE and resistivity. To explore further improvement, the effects of minor Ce additions (due to its mixed valence 4f-electron configuration) on the microstructure, electrical and magnetic behaviors of Fe–6.5 wt. % Si alloys were investigated. Due to its limited solubility in Fe, Ce exhibits condition-dependent effects on electrical resistivity, showing only marginal improvement under rapid solidification. In contrast, Ce addition degrades magnetic performance, reducing saturation magnetization (from 1.86 to 1.76 T) and increasing coercivity (from 88 to 171 A/m), which results in an 83.4% increase in core loss (W 10/1000 condition). Overall, Ce addition provides limited benefit in electrical resistivity while deteriorating magnetic properties, making it ineffective for enhancing the soft magnetic performance of Fe–6.5 wt. % Si alloys.

36 MATERIALS SCIENCE↗

Mitigating dust particle contamination in an afterglow plasma by controlled lifting with a DC electric field

Abstract Particle contamination due to plasma processing motivates the design of a method of electrically lifting particles in a time interval after a plasma’s power is turned off. Small solid dust particles have electric charges that are not frozen until a late stage of the plasma afterglow. Beyond that time, before they fall to a surface below and cause defects, particles can be lifted in a controlled manner by applying an appropriate direct-current (DC) electric field, as we demonstrate experimentally. A few milliseconds after an argon plasma’s capacitively coupled radio-frequency power is switched off, a vertical DC electric field is applied. Thereafter, video imaging shows that the falling of the particles is slowed or stopped altogether, depending on the magnitude of the upward electric force.

Physics↗

Diagnosing electric and magnetic fields in laser-driven coil targets

Laser-driven capacitor coils are widely used to generate intense magnetic fields for various applications in high-energy-density (HED) physics research. Accurate measurement of the magnetic fields is essential but challenging, due to the overlapping contributions from magnetic and electric fields in proton radiography, which is the primary tool diagnosing the field generation around the coils. In this study, we systematically analyze proton radiographs obtained from laser-driven capacitor-coil targets along two orthogonal axes under various electromagnetic field conditions, including magnetic field only, electric field only, and combined electromagnetic fields. By analyzing key features in the radiographs, we distinguish and characterize the respective contributions from magnetic and electric fields. Using detailed simulations validated by experimental benchmarks, methods to isolate and quantify the magnetic field and electric field are given. The methods are successfully applied to determine the electric current and charge distribution in a double coil configuration. Our findings provide insights into improving the diagnostic capability of proton radiography, potentially leading to more accurate measurements of electromagnetic fields and enhancing the utility of laser-driven capacitor coils in HED experiments.

electromagnetic field diagnostics↗

Townsend to glow discharge transition for a nanosecond pulse plasma in helium: space charge formation and resulting electric field dynamics

Stark polarization spectroscopy is used to investigate the temporal evolution of the electric field distribution in the cathode region of a nanosecond pulsed discharge in helium at 120 Torr. The measurements are performed on the He I transition at 492.19 nm, during the early stages of the discharge formation. The experimental results are compared with the predictions of a 1D fluid model. Time-resolved ICCD images show that the discharge develops as a diffuse, cathode-directed ionization wave with a Townsend-like feature before transitioning into a glow-like structure. Near anode instabilities characterized by filament formation were observed near the high voltage electrode. Within 30 ns, a reduction of the sheath thickness to about 250 μm is observed, coinciding with a gradual increase of the discharge current and proportional increase in electric field at the cathode. Additionally, the cathode electric field corresponding to this sheath with a thickness of 250 μm is about 40 kV cm -1 . A subsequent steep increase of the discharge current leads to a further reduction of the sheath width. The electric field evolution as obtained by the fluid model is in excellent agreement with the measurements and shows that an enhanced ionization near the cathode is causing the space charge formation responsible for the increase in electric field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dielectric screening and electric field control of ferromagnetism at the CaMnO 3 /CaRuO 3 interface

Control of magnetism by an applied electric field is a desirable technique for the functionalization of magnetic materials. Motivated by recent experiments, we study the electric field control of the interfacial magnetism of CaRuO 3 /CaMnO 3 (CRO/CMO) (001), a prototype interface between a non-magnetic metal and an antiferromagnetic insulator. Even without the electric field, the interfacial CMO layer acquires a ferromagnetic moment due to a spin-canted state, caused by the Anderson-Hasegawa double exchange (DEX) between the Mn moments and the leaked electrons from the CRO side. An electric field would alter the carrier density at the interface, leading to the possibility of controlling the magnetism, since DEX is sensitive to the carrier density. We study this effect quantitatively using density-functional calculations in the slab geometry. We find a text-book like dielectric screening of the electric field, which introduces polarization charges at the interfaces and the surfaces. The extra charge at the interface enhances the ferromagnetism via the DEX interaction, while away from the interface the original AFM state of the Mn layers remains unchanged. The effect could have potential application in spintronics devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Creating a three-dimensional intrinsic electric dipole on rotated CrI 3 bilayers

Here two-dimensional (2D) materials are being explored as a novel multiferroic platform. One of the most studied magnetoelectric multiferroic 2D materials are antiferromagnetically coupled (AFM) CrI 3 bilayers. Neglecting magnetism, those bilayers possess a crystalline point of inversion, which is only removed by the antiparallel spin configuration among its two constituent monolayers. The resulting intrinsic electric dipole on those bilayers has a magnitude no larger than 0.04 pC/m, it points out of plane, and it reverts direction when the Ising-like-chromium spins are flipped (toward opposite layers versus away from opposite layers). The combined presence of antiferromagnetism and a weak intrinsic electric dipole makes this material a two-dimensional magnetoelectric multiferroic. Here, we remove the crystalline center of inversion of the bilayer by a relative 60° rotation of its constituent monolayers. This process enhances the out-of-plane intrinsic electric dipole tenfold with respect to its magnitude in the nonrotated AFM bilayer and also creates an even stronger and switchable in-plane intrinsic electric dipole. The ability to create a three-dimensional electric dipole is important because it enhances the magnetoelectric coupling on this experimentally accessible 2D material, which is explicitly calculated here as well.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electrical Control of Magnetic Phase Transition in a Type-I Multiferroic Double-Metal Trihalide Monolayer

Controlling magnetism of two-dimensional multiferroics by an external electric field provides special opportunities for both fundamental research and future development of low-cost electronic nanodevices. Here, we report a general scheme for realizing a magnetic phase transition in 2D type-I multiferroic systems through the reversal of ferroelectric polarization. First, based on first-principles calculations, we demonstrate that a single-phase 2D multiferroic, namely, ReWCl 6 monolayer, exhibits two different low-symmetric ($C_2$) phases with opposite in-plane electric polarization and different magnetic order. As a result, an antiferromagnetic-to-ferromagnetic phase transition can be realized by reversing the in-plane electric polarization through the application of an external electric field. These findings not only enrich the 2D multiferroic family, but also uncover a unique and general mechanism to control magnetism by electric field, thus stimulating experimental interest.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electric Field Imaging Using Polarized Neutrons

In this paper, we experimentally demonstrate that electrically neutral particles, neutrons, can be used to directly visualize the electrostatic field inside a target volume that can be physically isolated or occupied. Electric field images are obtained using a spin-polarized neutron beam with a recently developed polarimetry method for polychromatic beams that permits detection of a small angular change in spin orientation. This work may enable a new diagnostic technique sensitive to the structure of electric potential, electric polarization, charge distribution, and dielectric constant by imaging spatially dependent electric fields in objects that cannot be accessed by other probes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of Measurement Temperature on Electrical Cable Frequency Domain Reflectometry Response

In nuclear power plants, electrical cables are exposed to stressors, such as elevated temperature and radiation. Evaluation of the effect of stressors on the lifetime of electrical cables can be conducted using offline electrical reflectometry techniques, such as frequency domain reflectometry (FDR). However, recent work has raised the concern that FDR measurements at temperatures higher than ambient may diminish or reduce the response due to stressors, potentially leading to incorrect predictions of electrical cable damage and lifetime. In this work, we explore the FDR response of an electrical cable exposed to an oven-based thermal stressor up to 140°C, including both ramping up and ramping down temperature. It was observed that, for both the oven entrance and exit, an increase in the FDR measurement temperature led to a decrease in the FDR reflection coefficient. In particular, it was found that the reflection coefficient at the oven entrance decreased from the ambient measurement by approximately 7%, 22%, and 36% at a temperature of 60°C, 100°C, and 140°C, respectively.

Spencer, Mychal P.↗

Energy Storage to Enable Electricity as a Commodity

A lack of large-scale economical storage, demand-side flexibility, and the need to instantaneously balance supply and demand cause challenges for electricity as a commodity. With typical commodities, stock from periods of high production can be stored and sold during low production, smoothing demand and supply shocks. In electricity markets, high storage costs have long outweighed benefits, negating convenience yield; no-arbitrage models do not apply, and typical hedging strategies cannot be performed due to infinite carry costs. However, the mechanics of energy trading are changing due to advancing storage technologies, more price-responsive demands, and virtual bidding in electricity markets, shaping a system where electricity storage can be valued on factors other than diurnal arbitrage. We examine the valuation of electricity storage through the lens of commodity markets to assess the impacts of large-scale storage deployment.

energy storage↗

A New Shape Optimization Approach for Lightweighting Electric Machines Inspired by Additive Manufacturing

Minimizing the mass in electric machines while maintaining superior performance is a new requirement for the advancement of drivetrains used in wind energy and electric mobility. Topology optimization (TO) for lightweighting electric machines using traditional approaches typically explores a restricted design space allowed by standard parametrizable geometry and manufacturing, while advanced methods, such as cell-based density approaches, suffer from a lack of robust manufacturability constraints during the optimization process. To overcome these drawbacks, we explore a grid-independent, boundary optimization where the outer shape of the magnet is parameterized using Bezier curves. We conduct a design of experiments (DOE) to study the effect of different magnet shapes on machine performance by varying the control points on the Bezier curves. A machine-learning-based surrogate model is constructed using the data from the DOE to quantify the relationship between the control points, air-gap torque, and mass. The control points are then optimized to maximize the torque density. The approach is used for minimizing electrical steel mass in the International Energy Agency (IEA) 15-MW radial flux direct-drive wind turbine generator. The new approach to shape optimization resulted in smooth and concise shapes that can be easily additively manufactured with up to a 20-ton reduction in electrical steel mass.

additive manufacturing↗

Efficient Hydraulic-to-electric Energy Conversion for PCM-based Ocean Thermal Gradient Energy System to Power Uncrewed Underwater Vehicles

Since the 2000, there have been numerous investigations into electrical energy storage types that use ocean thermal-to-electricity conversion techniques. Field tests have demonstrated that this technology is feasible for UUVs with long-term missions of over 3,000 km per deployment. Nonetheless, the energy generated by this method is not sufficient to meet the energy requirements of Unscrewed Underwater Vehicles (UUVs). The objective of this study is to design a highly effective ocean thermal gradient energy system to support long-term missions of a UUV. To enhance the performance of the thermal gradient energy system, we have developed a hybrid type (buoyancy regulation and electrical storage). Phase Change Material (PCM)-based energy harvesting system to facilitate efficient UUV operations. A prototype of the hydraulic-to-electric conversion system was implemented, and experimental findings indicate that the hybrid system successfully delivers hydraulic energy for buoyancy change and improved efficiency of hydraulic-to-electric energy conversion, demonstrating its potential as a promising technology for supporting long-term UUV missions.

Deng, Zhiqun↗

On Harmonizing Today’s Regulated Tariffs and Future Dynamic Electricity Pricing

A novel method for harmonizing the advantages of dynamic retail electricity pricing with the protections of regulated electricity tariffs is discussed and demonstrated. The method socializes and protects customers from long-term locational price variability that is unfair to those customers who are, by no fault of their own, served at congested locations on a distribution system. However, the method preserves short-term (e.g., diurnal) price variability that might induce helpful, mitigative responses from retail electricity customers. Because the method causes actual price recovery to track a customer class’s approved, regulated price recovery, the method may remove regulators’ objections to dynamic electricity pricing and thereby hasten adoption of market-based retail electricity pricing and transactive energy systems.

Consumer protection, Demand response, Market resea↗

Joint Management and Optimization of Residential Natural Gas and Electricity Distribution Networks Coupled via Fuel Cells

The interesting properties of natural gas as well as the growing electric power demand worldwide have led to increasing attention to natural-gas-based distributed generation applications in electric distribution systems. This paper goes over the interdependency between a residential natural gas network and an electric distribution network that are coupled via fuel cells. The modeling of the gas network is introduced first, and then the algorithm for gas flow study is presented. The optimal placement and sizing of fuel cell based distributed generation systems are formulated to minimize the losses in both the gas and electric distribution networks, subject to their model constraints. In addition to this, in order to capture the probabilistic nature of the optimization problem under study, the K-means clustering algorithm is applied to the gas and electricity demands to determine hourly load states and their corresponding probabilities. Furthermore, simulation studies are carried out on an integrated system consisting of the IEEE 69-bus distribution feeder and a radial 27-node natural gas network to verify the developed optimization model and the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Review of recent studies on nanoscale electrical junctions and contacts: Quantum tunneling, current crowding, and interface engineering

The study of charge carrier transport at nanoscale electrical contacts is crucial for the development of next-generation electronics. In this study, we review recent modeling efforts on quantum tunneling, current crowding, and contact resistance across electrical interfaces with nanometer scale dimensions. A generalized self-consistent model for quantum tunneling induced electron transport in metal–insulator–metal (MIM) junctions is summarized. Rectification of a dissimilar MIM junction is reviewed. A modified two-dimensional (2D) transmission line model is used to investigate the effects of spatially varying specific contact resistivity along the contact length. The model is applied to various types of electrical contacts, including ohmic contacts, MIM junction based tunneling contacts, and 2D-material-based Schottky contacts. Roughness engineering is recently proposed to offer a possible paradigm for reducing the contact resistance of 2D-material-based electrical contacts. Contact interface engineering, which can mitigate current crowding near electrical contacts by spatially designing the interface layer thickness or properties, without requiring an additional material or component, is briefly reviewed. Tunneling engineering is suggested to eliminate severe current crowding in highly conductive ohmic contacts by introducing a thin tunneling layer or gap between the contact members. Furthermore, unsolved problems and challenges are also discussed.

2D materials↗

Electric field control of magnon spin currents in an antiferromagnetic insulator

Pure spin currents can be generated via thermal excitations of magnons. These magnon spin currents serve as carriers of information in insulating materials, and controlling them using electrical means may enable energy efficient information processing. Here, we demonstrate electric field control of magnon spin currents in the antiferromagnetic insulator Cr 2 O 3 . We show that the thermally driven magnon spin currents reveal a spin-flop transition in thin-film Cr 2 O 3 . Crucially, this spin-flop can be turned on or off by applying an electric field across the thickness of the film. Using this tunability, we demonstrate electric field–induced switching of the polarization of magnon spin currents by varying only a gate voltage while at a fixed magnetic field. We propose a model considering an electric field–dependent spin-flop transition, arising from a change in sublattice magnetizations via a magnetoelectric coupling. These results provide a different approach toward controlling magnon spin current in antiferromagnets.

36 MATERIALS SCIENCE↗

BEEAM (Building Electrical Efficiency Analysis Model) [SWR-20-107]

Modern high-performance buildings exhibit an increasing number of building loads that use direct current (DC) electricity internally, rather than alternating current (AC), due to the advent of low-cost computing and advanced power electronics. Powering DC devices from the AC grid requires AC/DC power conversion, which introduces energy losses and reduces efficiency. As DC loads proliferate, the cumulative wasted energy associated with hundreds of millions of AC/DC converters has become one of the broadest energy savings opportunities in buildings. DC power distribution systems have been proposed as an elegant and transformative solution to the problem of DC devices. In a DC distribution system, the building's wires carry DC electricity, rather than AC; and a few centralized, highly efficient AC/DC converters replace the many smaller, less efficient converters that serve individual DC loads. Unfortunately, the trade-offs associated with DC distribution systems are not well understood. Reported energy savings associated with DC power distribution differ widely and have not been well validated. The Building Electrical Efficiency Analysis Model (BEEAM) is a Modelica library that simulates the efficiency of building electrical distribution systems using harmonic power flow. BEEAM can model a wide variety of building distribution topologies, including three-phase AC, single-phase AC, unipolar DC, bipolar DC, and hybrid networks under both balanced and unbalanced load conditions. BEEAM accurately models power electronic converter losses, provides granular estimates of losses throughout the distribution system, and properly models efficiency at part load conditions. Users can package BEEAM within a functional mockup unit (FMU), enabling co-simulation with other modeling platform, such as EnergyPlus. In summary, BEEAM provides a tool suite for fair and accurate comparison of the efficiency of building electrical distribution systems, including AC, DC, and hybrid systems.

Frank, Stephen↗

A parametric analysis of oilfield design factors affecting the detectability and characterization of electrically conductive hydrofracks

Electrical responses in the vicinity of energized steel-cased well sources offer significant potential for monitoring induced fractures. However, the high complexity of well-fracture-host models spanning multiple length scales compels analysts to simplify their numerical models due to enormous computational costs. This consequently limits our understanding regarding monitoring capabilities and the limitations of electrical measurements on realistic hydraulically fracturing systems. In this paper, we use the hierarchical finite element approach to construct geoelectric models in which geometrically complex fractures and steel-cased wells are discretely represented in 3D conducting media without sacrificing the model realism and computation efficiency. We have discovered systematic numerical analyses of the electrical responses to evaluate the influences of borehole material conductivity and the source type as well as the effects of well geometry, conductivity contrast, source location, fracture growth, and fracture propagation. Furthermore, the numerical results indicate that the borehole material property has a strong control on the electrical potentials along the production and monitoring wells. The monopole source located at a steel-cased well results in a current density distribution that decays away from the source location throughout the well length, whereas the dipole source produces a current density that dominates mainly along the dipole length. Moreover, the conductivity contrast between the fractures and host does not change the overall pattern of the electrical potentials but varies its amplitude. The fracture models near different well systems indicate that the well geometry controls the entire distribution of potentials, while the characteristics of the voltage difference profiles along the wells before and after fracturing are insensitive to the well geometry and the well in which the source is located. Further, the hydraulic-fracturing models indicate that the voltage differences along the production well before and after fracturing have strong sensitivity to fracture growth and fracture set propagation.

58 GEOSCIENCES↗