Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “doppler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Time delay and Doppler tests of the Lorentz symmetry of gravity

Modifications to the classic time-delay effect and Doppler shift in general relativity (GR) are studied in the context of the Lorentz-violating standard-model extension (SME). We derive the leading Lorentz-violating corrections to the time-delay and Doppler shift signals, for a light ray passing near a massive body. It is demonstrated that anisotropic coefficients for Lorentz violation control a time-dependent behavior of these signals that is qualitatively different from the conventional case in GR. Estimates of sensitivities to gravity-sector coefficients in the SME are given for current and future experiments, including the recent Cassini solar conjunction experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photonic Doppler Velocimetry Probe Designed with Stereo Imaging

The velocity distribution of an imploding curved surface is measured with a miniature fiber-optic probe. The probe uses fiber matrix arrays that are focused onto different regions of this curved surface. A pyramid reflector deflects the interrogation onto specific regions of this curved surface. The fiber arrays record velocity along several hundred lines of sight with sub-nanosecond resolution. Reflected light from each spot on the moving surface is Doppler shifted with a small portion of this light propagating backwards through the launching fiber. The reflected light is mixed with a reference laser in a technique called Photonic Doppler velocimetry, providing continuous time records. Within the probe, seven groups of miniature optical relay lenses are grouped into a close-packed array, allowing the interrogation of seven regions of interest. A six-faceted pyramid reflector with a conical hole drilled into its center is used to direct the light beams onto different regions. To minimize back reflections, the fiber matrix arrays are index matched onto the first relay lens made of fused silica. The optical lens design minimizes the laser beam diameters and also provides excellent imaging capabilities. Therefore, two of the fiber matrix arrays are replaced by coherent bundles for stereo imaging recorded by a high-speed framing camera. This requires additional cutouts of the pyramid reflector to allow imaging overlap. Six additional 1.5 mm diameter incoherent bundles are attached to the edges of the pyramid reflector and are used for illumination. Precision metrology on the direction cosines of the trajectories is measured to satisfy environmental requirements for vibration and temperature.

photonic doppler velocimetry, PDV, pyramid reflect↗

Design, Assembly, and Testing of a Photon Doppler Velocimetry Probe

A novel fiber-optic probe measures the velocity distribution of an imploding surface along many lines of sight. Reflected light from each spot on the moving surface is Doppler shifted with a small portion of this light propagating backwards through the launching fiber. The reflected light is mixed with a reference laser in a technique called photon Doppler velocimetry, providing continuous time records. Within the probe, a matrix array of 56 single-mode fibers sends light through an optical relay consisting of three types of lenses. Seven sets of these relay lenses are grouped into a close-packed array allowing the interrogation of seven regions of interest. A six-faceted prism with a hole drilled into its center directs the light beams to the different regions. Several types of relay lens systems have been evaluated, including doublets and molded aspheric singlets. The optical design minimizes beam diameters and also provides excellent imaging capabilities. One of the fiber matrix arrays can be replaced by an imaging coherent bundle. This close-packed array of seven relay systems provides up to 476 beam trajectories. The pyramid prism has its six facets polished at two different angles that will vary the density of surface point coverage. Fibers in the matrix arrays are angle polished at 8{sup o} to minimize back reflections. This causes the minimum beam waist to vary along different trajectories. Precision metrology on the direction cosine trajectories is measured to satisfy environmental requirements for vibration and temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Fisheye Lens as a Photonic Doppler Velocimetry Probe

A new fisheye lens design is used as a miniature probe to measure the velocity distribution of an imploding surface along many lines of sight. Laser light, directed and scattered back along each beam on the surface, is Doppler shifted by the moving surface and collected into the launching fiber. The received light is mixed with reference laser light in each optical fiber in a technique called photonic Doppler velocimetry, providing a continuous time record. An array of single-mode optical fibers sends laser light through the fisheye lens. The lens consists of an index-matching positive element, two positive doublet groups, and two negative singlet elements. The optical design minimizes beam diameters, physical size, and back reflections for excellent signal collection. The fiber array projected through the fisheye lens provides many measurement points of surface coverage over a hemisphere with very little crosstalk. The probe measures surface movement with only a small encroachment into the center of the cavity. The fiber array is coupled to the index-matching element using index-matching gel. The array is bonded and sealed into a blast tube for ease of assembly and focusing. This configuration also allows the fiber array to be flat polished at a common object plane. In areas where increased measurement point density is desired, the fibers can be close packed. To further increase surface density coverage, smaller-diameter cladding optical fibers may be used.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wave Nature of the Transverse Doppler Effect and the “Red” and “Blue” Frequency Shift Anomaly in an Electromagnetic Wave from a Moving Radiation Source

The electromagnetic field of a harmonic oscillator moving at a constant velocity has been analyzed. The expression for calculating the Doppler frequency shift at relativistic velocities of its motion is derived using the classical electromagnetic theory. It is shown that the transverse Doppler effect is a special case and also differs from zero in the wave theory. With an increasing velocity of the radiation source, the “red” frequency shift in an electromagnetic wave prevails over the “blue” shift more strongly. The noncontradictory nature of the proposed model relative to the well-known experimental data has been demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement uncertainty and temporal resolution of Doppler global velocimetry using laser frequency modulation

A Doppler global velocimetry (DGV) measurement technique with a sinusoidal laser frequency modulation is presented for measuring velocity fields in fluid flows. A cesium absorption cell is used for the conversion of the Doppler shift frequency into a change in light intensity, which can be measured by a fiber coupled avalanche photo diode array. Because of a harmonic analysis of the detector element signals, no errors due to detector offset drifts occur and no reference detector array is necessary for measuring the scattered light power. Hence, large errors such as image misalignment errors and beam split errors are eliminated. Furthermore, the measurement system is also capable of achieving high measurement rates up to the modulation frequency (100 kHz) and thus opens new perspectives to multiple point investigations of instationary flows, e.g., for turbulence analysis. A fundamental measurement uncertainty analysis based on the theory of Cramer and Rao is given and validated by experimental results. The current relation between time resolution and measurement uncertainty, as well as further optimization strategies, are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Doppler Lidar Observations over a High Altitude Mountainous Site Manora Peak in the Central Himalayan Region

The RAWEX-GVAX field campaign has been carried out from June 2011 to March 2012 over a high altitude site Manora Peak, Nainital (29.4 degrees N; 79.2 degrees E; 1958 m amsl) in the central Himalayas to assess the impacts of absorbing aerosols on atmospheric thermodynamics and clouds. This paper presents the preliminary results of the observations and data analysis of the Doppler Lidar, installed at Nainital. Strong updrafts with vertical winds in the range of similar to 2-4 ms(-1) occurred during the daytime and throughout the season indicating thermally driven convection. On the other hand during nighttime, weak downdrafts persisted during stable conditions. Plan Position Indicator scan of Doppler Lidar showed north-northwesterly winds in the boundary layer. The mixing layer height, derived from the vertical velocity variance, showed diurnal variations, in the range similar to 0.7-1 km above ground level during daytime and very shallow during nighttime.

Boundary layer↗

Multigroup Free-atom Doppler-broadening Approximation. Theory

Multigroup cross sections at a one target temperature can be Doppler-broadened to multigroup cross sections at a higher target temperature by matrix multiplication if the group structure suf- ficiently resolves the original temperature continuous energy cross section. Matrix elements are the higher temperature group weighted averages of the integral over the lower temperature group boundaries of the free-atom Doppler-broadening kernel. The results match theory for constant and 1/v multigroup cross sections at 618 lanl group structure resolution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Some Notes on Neutron Up-Scattering and the Doppler-Broadening of High-Z Scattering Resonances

When neutrons are scattered by target nuclei at elevated temperatures, it is entirely possible that the neutron will actually gain energy (i.e., up-scatter) from the interaction. This phenomenon is in addition to the more usual case of the neutron losing energy (i.e., down-scatter). Furthermore, the motion of the target nuclei can also cause extended neutron down-scattering, i.e., the neutrons can and do scatter to energies lower than predicted by the simple asymptotic models. In recent years, more attention has been given to temperature-dependent scattering cross sections for materials in neutron multiplying systems. This has led to the inclusion of neutron up-scatter in deterministic codes like Partisn and to free gas scattering models for material temperature effects in Monte Carlo codes like MCNP and cross section processing codes like NJOY. The free gas scattering models have the effect of Doppler Broadening the scattering cross section output spectra in energy and angle. The current state of Doppler-Broadening numerical techniques used at Los Alamos for scattering resonances will be reviewed, and suggestions will be made for further developments. The focus will be on the free gas scattering models currently in use and the development of new models to include high-Z resonance scattering effects. These models change the neutron up-scattering behavior.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Minior Actinide Doppler Coefficient Measurement Assessment

The "Minor Actinide Doppler Coefficient Measurement Assessment" was a Department of Energy (DOE) U-NERI funded project intended to assess the viability of using either the FLATTOP or the COMET critical assembly to measure high temperature Doppler coefficients. The goal of the project was to calculate using the MCNP5 code the gram amounts of Np-237, Pu-238, Pu-239, Pu-241, AM-241, AM-242m, Am-243, and CM-244 needed to produce a 1E-5 in reactivity for a change in operating temperature 800C to 1000C. After determining the viability of using the assemblies and calculating the amounts of each actinide an experiment will be designed to verify the calculated results. The calculations and any doncuted experiments are designed to support the Advanced Fuel Cycle Initiative in conducting safety analysis of advanced fast reactor or acceoerator-driven transmutation systems with fuel containing high minor actinide content.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Doppler shift of the quiet region measured by meridional scans with the EUV imaging spectrometer on board Hinode

Spatially averaged (>50{sup ′′}) EUV spectral lines in the transition region of solar quiet regions are known to be redshifted. Because the mechanism underlying this phenomenon is unclear, we require additional physical information on the lower corona in order to limit the theoretical models. To acquire this information, we measured the Doppler shifts over a wide coronal temperature range (logT [K]=5.7–6.3) using the spectroscopic data taken by the Hinode EUV Imaging Spectrometer. By analyzing the data over the center-to-limb variations covering the meridian from the south to the north pole, we successfully measured the velocity to an accuracy of 3 km s{sup −1}. Below logT [K]=6.0, the Doppler shifts of the emission lines were almost zero with an error of 1–3 km s{sup −1}; above this temperature, they were blueshifted with a gradually increasing magnitude, reaching −6.3±2.1 km s{sup −1} at logT [K]=6.25.

79 ASTRONOMY AND ASTROPHYSICS↗

Doppler LIDAR Motion-corrected Wind Speed and Direction Profiles VAP

The dlmcprof-wind VAP contains profiles of wind speed and direction that are computed using motion-corrected Doppler lidar data from the dlmc VAP. The dlmcprof-wind VAP was specifically developed to process scanning data acquired by the ARM Doppler lidar aboard the Polarstern during the MOSAiC campaign.

54 ENVIRONMENTAL SCIENCES↗

Digital storage and analysis of color Doppler echocardiograms

Color Doppler flow mapping has played an important role in clinical echocardiography. Most of the clinical work, however, has been primarily qualitative. Although qualitative information is very valuable, there is considerable quantitative information stored within the velocity map that has not been extensively exploited so far. Recently, many researchers have shown interest in using the encoded velocities to address the clinical problems such as quantification of valvular regurgitation, calculation of cardiac output, and characterization of ventricular filling. In this article, we review some basic physics and engineering aspects of color Doppler echocardiography, as well as drawbacks of trying to retrieve velocities from video tape data. Digital storage, which plays a critical role in performing quantitative analysis, is discussed in some detail with special attention to velocity encoding in DICOM 3.0 (medical image storage standard) and the use of digital compression. Lossy compression can considerably reduce file size with minimal loss of information (mostly redundant); this is critical for digital storage because of the enormous amount of data generated (a 10 minute study could require 18 Gigabytes of storage capacity). Lossy JPEG compression and its impact on quantitative analysis has been studied, showing that images compressed at 27:1 using the JPEG algorithm compares favorably with directly digitized video images, the current goldstandard. Some potential applications of these velocities in analyzing the proximal convergence zones, mitral inflow, and some areas of future development are also discussed in the article.

NASA Discipline Cardiopulmonary↗

Estimation of left ventricular operating stiffness from Doppler early filling deceleration time in humans

Shortened early transmitral deceleration times (E(DT)) have been qualitatively associated with increased filling pressure and reduced survival in patients with cardiac disease and increased left ventricular operating stiffness (K(LV)). An equation relating K(LV) quantitatively to E(DT) has previously been described in a canine model but not in humans. During several varying hemodynamic conditions, we studied 18 patients undergoing open-heart surgery. Transesophageal echocardiographic two-dimensional volumes and Doppler flows were combined with high-fidelity left atrial (LA) and left ventricular (LV) pressures to determine K(LV). From digitized Doppler recordings, E(DT) was measured and compared against changes in LV and LA diastolic volumes and pressures. E(DT) (180 +/- 39 ms) was inversely associated with LV end-diastolic pressures (r = -0.56, P = 0.004) and net atrioventricular stiffness (r = -0.55, P = 0.006) but had its strongest association with K(LV) (r = -0.81, P < 0.001). K(LV) was predicted assuming a nonrestrictive orifice (K(nonrest)) from E(DT) as K(nonrest) = (0.07/E(DT))(2) with K(LV) = 1.01 K(nonrest) - 0.02; r = 0.86, P < 0.001, DeltaK (K(nonrest) - K(LV)) = 0.02 +/- 0.06 mm Hg/ml. In adults with cardiac disease, E(DT) provides an accurate estimate of LV operating stiffness and supports its application as a practical noninvasive index in the evaluation of diastolic function.

Non-NASA Center↗

Effect of scanline orientation on ventricular flow propagation: assessment using high frame-rate color Doppler echocardiography

Color M-mode echocardiography has recently been utilized to describe diastolic flow propagation velocity (Vp) in the left ventricle. While increasing temporal resolution from 15 to 200 Hz, this M-mode technique requires the user to select a single scanline, potentially limiting quantification of Vp due to the complex three-dimensional inflow pattern. We previously performed computational fluid dynamics simulations to demonstrate the insignificance of the scanline orientation, however geometric complexity was limited. The purpose of this study was to utilize high frame-rate 2D color Doppler images to investigate the importance of scanline selection in patients for the quantification of Vp. 2D color Doppler images were digitally acquired at 50 frames/s in 6 subjects from the apical 4-chamber window (System 5, GE/Vingmed, Milwaukee, WI). Vp was determined for a set of scanlines positioned through 5 locations across the mitral annulus (from the anterior to posterior mitral annulus). An analysis of variance was performed to examine the differences in Vp as a function of scanline position. Vp was not effected by scanline position in sampled locations from the center of the mitral valve towards the posterior annulus. Although not statistically significant, there was a trend to slower propagation velocities on the anterior side of the valve (60.8 +/- 16.7 vs. 54.4 +/- 13.6 cm/s). This study clinically validates our previous numerical experiment showing that Vp is insensitive to small perturbations of the scanline through the mitral valve. However, further investigation is necessary to examine the impact of ventricular geometry in pathologies including dilated cardiomyopathy.

Non-NASA Center↗

New echocardiographic windows for quantitative determination of aortic regurgitation volume using color Doppler flow convergence and vena contracta

Color Doppler images of aortic regurgitation (AR) flow acceleration, flow convergence (FC), and the vena contracta (VC) have been reported to be useful for evaluating severity of AR. However, clinical application of these methods has been limited because of the difficulty in clearly imaging the FC and VC. This study aimed to explore new windows for imaging the FC and VC to evaluate AR volumes in patients and to validate this in animals with chronic AR. Forty patients with AR and 17 hemodynamic states in 4 sheep with strictly quantified AR volumes were evaluated. A Toshiba SSH 380A with a 3.75-MHz transducer was used to image the FC and VC. After routine echo Doppler imaging, patients were repositioned in the right lateral decubitus position, and the FC and VC were imaged from high right parasternal windows. In only 15 of the 40 patients was it possible to image clearly and measure accurately the FC and VC from conventional (left decubitus) apical or parasternal views. In contrast, 31 of 40 patients had clearly imaged FC regions and VCs using the new windows. In patients, AR volumes derived from the FC and VC methods combined with continuous velocity agreed well with each other (r = 0.97, mean difference = -7.9 ml +/- 9.9 ml/beat). In chronic animal model studies, AR volumes derived from both the VC and the FC agreed well with the electromagnetically derived AR volumes (r = 0.92, mean difference = -1.3 +/- 4.0 ml/beat). By imaging from high right parasternal windows in the right decubitus position, complementary use of the FC and VC methods can provide clinically valuable information about AR volumes.

NASA Discipline Cardiopulmonary↗