Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distribution system voltage control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Safe Deep Reinforcement Learning for Robust Frequency and Voltage-Constrained Networked Microgrid Restoration

Here, this paper proposes a safe soft actor-critic reinforcement learning (RL) algorithm–based controller for networked microgrid restoration. It formulates the post black-start start as a finite-horizon constrained Markov decision process. The RL agent co-optimizes real and reactive power set-points for both grid-forming and grid-following inverters under explicit voltage and frequency constraints, while enforcing proper power sharing via the Mean Active Power Sharing Index (MPSI) and Mean Reactive Power Sharing Index (MQSI). Numerical results obtained on the IEEE 123-bus distribution system show that the proposed method achieves a mean voltage build-up time of 0.01 s without breaching the 5% sharing-violation budget under various load scenarios, considering MPSI and MQSI indices. These findings demonstrate that the proposed method yields fast and safe black-start schedules without resorting to heuristic penalties.

Selim, Alaa [Dartmouth College, Hanover, NH (Unite↗

Power Hardware-in-the-Loop Interfaces for Inverter-Based Microgrid Experiments Including Transitions: Preprint

Microgrids continue to proliferate, particularly those that rely on inverter-based resources as the microgrid's voltage and frequency leader. Hardware-in-the-loop (HIL) simulations can de-risk microgrid deployments, and therefore we need power-hardware-in-the-loop (PHIL) interfaces for grid-forming (GFM) inverters to enable simulations of seamless transitions between islanded and grid-connected operation. Such microgrid interfaces are particularly challenging to model when the inverters need to switch modes, i.e., between grid-following (GFL) and GFM as the microgrid transitions between grid-connected and islanded operation. This paper presents two PHIL interfaces for such microgrids and the preliminary experimental results: One interface is suitable for those who have access to a power amplifier that can operate as a controllable current source, and the other is for those who need a solution that uses a voltage-mode power amplifier.

battery energy storage system↗

Dynamic Building Load Control to Facilitate High Penetration of Solar Photovoltaic Generation (Final Technical Report)

Solar photovoltaic (PV) resources are the most common form of distributed generation in residential and commercial customer premises within electric distribution networks. A higher penetration of PV generation in distribution circuits will impose challenges on maintaining service voltages within the range of industry standards, power quality, and power flow. Buildings consume 74% of the electricity produced in the United States, and a significant portion of the building load is dispatchable, making them responsive to electrical grid needs. Oak Ridge National Laboratory—in collaboration with Southern Company; the University of Tennessee, Knoxville; and the Georgia Institute of Technology—is examining the PV integration issues in distribution-level electrical grids and developing integrated demand-side control and communication systems to enable responsive loads. The proposed responsive loads mechanism performs renewable generation following to increase the penetration of solar PV within each feeder. The specific objectives of this project are to (1) examine distribution-level PV integration scenarios to understand requirements, (2) undertake an end-to-end simulation-based design of a distributed control strategy of loads geographically near the PV generation asset to minimize the effect on the distribution feeder, (3) deploy and demonstrate the control technology developed in partnership with utilities, and (4) perform a scalability analysis at the utility scale. This 3-year integrated project aims to develop, demonstrate, and validate demand-side control technology to enable increased the penetration of renewables while mitigating challenges that arise due to their intermittency. Activities in Budget Period (BP) 1 focused on a literature review and the formal design of a control system for integrating local distribution with generation and loads. The team used modeling and simulation to evaluate the impact of varying buildings loads, variable PV generation, and power flow dynamics on the distribution circuit. The dynamic models developed in BP 1 were used in BP 2 to develop a model-based control design and a test bed. The test bed has enabled the simulation-based testing and comparison of different control designs and formulations applied to different configurations of the distribution grid, PVs, and building loads. The control approaches developed in BP 2 were implemented in BP 3 in the form of hardware deployed at the Central Baptist Church (CBC) in Knoxville, Tennessee, for testing and evaluation. The outcome of this project was the development and demonstration of open-source, low-cost, low-touch sensing and control retrofits to distributed PV generation and building loads that, in a coordinated fashion, provide the load-shaping response needed to integrate high levels of renewable penetration. This research addresses the target metrics by dynamically controlling a load with solar generation variability to minimize the extent of two-way power flow, enhance reliability, facilitate high PV penetration (>100% of peak load in a line segment), and generate scalable software and hardware solutions adaptable to any penetration levels. The research and development activities are focused and designed to be impactful within the relevant 2020 targets time frame.An accurate open-source integration simulation framework for end-to-end control design was developed and deployed at the CBC facility for testing and evaluation. This final report provides a detailed review of the technical results achieved during this 3-year integrated project. A novel spectral analysis of PV data is demonstrated to derive the requirements of the control design. A detailed simulation-based analysis of PV integration at increasing penetration levels is presented using 1 year of PV data to demonstrate the impact on the distribution circuits. Two different control strategies were developed and demonstrated via simulation to track variable PV generation with adaptive load dispatch. The report concludes with a summary of accomplishments and recommendations for a path forward.

14 SOLAR ENERGY↗

Advanced Distributed Wind Turbine Controls Series: Part 2-Wind Energy in Isolated Grids – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In an isolated grid, wind turbines are typically deployed to provide energy to maximize energy production, reduce diesel-fuel consumption, reduce carbon emissions, and reduce costs for energy and fuel transportation. However, in addition to solely providing energy to the power system, wind turbines contain rotating masses and inverter-based controls that can enable various reliability and resilience services through advance controls. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) this paper demonstrates, through desktop simulations, advanced wind turbine controls that can be employed to support higher contributions of wind in isolated grids, and to demonstrate ways that wind can play a role in supporting stability of an isolated grid. This isolated grid used in these desktop simulations is comprised of a wind turbine (600 kW), solar PV (430 kW), battery energy storage system (1 MW/1MWh), a simulated diesel generator (2 MW) and various types of loads (critical, dynamic). We developed a model of the subsystems in MATLAB/Simulink and validated them with available data from real-world components on NREL's Flatirons Campus. These validated models are then configured for various case studies. We compare the output of the desktop simulation with a baseline case with the diesel generator. Active and reactive power control of the wind turbine can help improve frequency and voltage responses in the isolated grid, respectively. By utilizing a small integrated battery energy storage system in the DC-link of the wind turbine, we also demonstrate that wind turbines can help blackstart a critical load comparable to its rated power and support other renewables (e.g. solar PV) come online and pick up an additional load. This report illustrates some of these reliability and resilience services a wind turbine can provide in an isolated grid.

17 WIND ENERGY↗

Status of the Mu2e calorimeter readout electronics

The Mu2e experiment [1] at Fermilab will search for the neutrino-less coherent conversion of a muon into an electron in the field of a nucleus. Mu2e detectors comprise a straw tracker, an electromagnetic calorimeter and a veto for cosmic rays. The calorimeter employs 1348 Cesium Iodide crystals readout by silicon photomultipliers and fast front-end and digitization electronics. The front-end electronics consists of two discrete readout circuits (AMP-HV) for each crystal. These provide the amplification, shaping stage and linear regulation of the SiPM bias voltage and monitoring. The SiPM and front-end control electronics is implemented in a battery of mezzanine boards each equipped with an ARM processor that controls a group of 20 Amp-HV circuits distributing the low voltage and the high-voltage. The electronic is hosted in crates located on the external surface of calorimeter disks. The crates also host the waveform digitizer board (DIRAC) that performs digitization of the front end signals and transmit the digitized data to the Mu2e DAQ. Calorimeter electronic is hosted inside the cryostat and must sustain very high radiation and magnetic field so it was necessary to fully qualify it. The system design and quality assurance procedures will be reviewed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cyber Attack Resilient HVDC System (CARDS) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE-OE funded project DE-OE0000824, where ABB Inc. (ABB), in collaboration with University of Illinois at Urbana-Champaign (UIUC), Bonneville Power Administration (BPA), Argonne National Laboratories (ANL), and University of Idaho (UI) pursued the development of a system of defense for High Voltage Direct Current transmission systems against cyber-attacks (CARDS). An HVDC substation with CARDS features will be more capable of mitigating cyber-attacks especially those that seek to control or interrupt the power flow in the HVDC line. It empowers existing HVDC intelligent electronic devices to collaborate in identifying and blocking malicious intents to trip HVDC AC circuit breakers, block thyristor valves, misconfigure devices settings, even though the commands and the measurements comply with correct syntax. The CARDS functions utilize the physics of electromagnetic AC and DC systems, electric power engineering principles, and state estimation to bring more in-depth cyber defense closer to the protected HVDC substation devices. With the aim of advancing the state of the art, the team proceeded to develop a demonstrable system against cyber-attacks in an HVDC substation environment, via functional upgrades to existing firmware of commercial off-the-shelf HVDC station devices, and/or embedded hardware, without the need for additional instrumentation nor new instrumentation technologies. It is to ensure that the solutions resulting from the project will support the HVDC devices currently installed in the US electricity delivery infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Differential Power Processing for Ultra-Efficient Data Storage

Here this paper presents the hardware, software, and power codesign of an ultra-efficient data storage server with differential power processing (DPP). DPP can reduce the power conversion stress, improve the efficiency, and enhance the functionality of modular power electronics systems. The power inputs of a large number of hard disk drives (HDDs) were connected in series and supported by a multiport ac-coupled differential power processing (MAC-DPP) converter through a multiwinding transformer. Methods for controlling the multi-input multi-output power flow in the multiwinding transformer while avoiding core saturation were investigated. A ten-port MAC-DPP prototype with 700-W/in 3 power density was built to support a 450-W HDD storage system with ten series-stacked voltage domains. The prototype was tested on a 50-HDD server testbench, and the overall system loss is below 1 W (99.77% system efficiency). The server was able to maintain high-speed reading and writing operation of all 50 HDDs against the worst hot-swapping scenarios. A variety of hardware/software configurations and many cloud storage techniques were tested on the fully functioning server. Experimental results show that the energy efficiency of large-scale information systems (CPU/GPU clusters, memory banks, HDD arrays, etc.) can be greatly improved by software, hardware, and power codesign.

42 ENGINEERING↗

Spatiotemporal Pattern Recognition in the PMU Signals in the WECC system

Phasor measurement unit (PMU) data has been used by multiple power system applications, including state estimation, post event analysis, oscillation detection, model validation, and many others. Still, due to its big data nature and availability to general research institutions, comprehensive understanding of the spatiotemporal patterns and underlying mechanisms are incomplete. This study applies a set of signal processing and machine learning approaches aiming at deciphering the characteristic behaviors of multiple phasor measurement units (PMUs) attributes (e.g., voltage, frequency, rate of change of frequency, phase angle), including their auto-correlation, cross-dependence, similarities and discrepancies across units and temporal scales, and distributions of anomalies and their linkages to potential external factors such as weather events. Data analytics are applied to PMUs from the U.S. Western Electricity Coordinating Council (WECC) system. The PMU measurements, recorded events, outages, and weather extremes are all from real world datasets. The findings from the study and mechanistic understanding of the PMU dynamics help provide guidance on system control or preventing blackouts. The derived metrics can be directly used for adjusting or filtering simulated PMU data used for advanced algorithm development.

Hou, Zhangshuan↗

VOLTTRON™ Agent Development for Enabling Reactive Power Support of Non-Utility DERs by Integrating Transactive Energy Approach

To enable better voltage regulation in power systems with high penetration of photovoltaics (PV) and other distributed energy resources (DERs), future inverters are required to provide reactive power support to the grid in addition to providing real power generated by PV panels. This paper develops a framework that coordinates the support from DER-based inverters, which are grid-connected non-utility assets, by using a transactive energy approach. Results of the implementation demonstrate participation of DER-based inverters can be achieved by using the coordination between distributed controllers and a centralized controller. With the transactive energy approach, both the customer and utility can achieve benefits that meet their individual needs.

Kritprajun, Paychuda↗

CyDER: A Cyber Physical Co-simulation Platform for Distributed Energy Resources in Smartgrids

The CyDER project aimed at developing an open-source, modular and scalable co-simulation platform for power grids with large shares of Distributed Energy Resources (DERs). The project partners are the Lawrence Berkeley National Lab (LBNL), Lawrence Livermore National Lab (LLNL), PG&E, SolarCity, and ChargePoint. The prime recipient is LBNL; SolarCity and ChargePoint were partners for the project’s first two years. Increased DER integration introduces a number of challenges in power grid operation including a more dynamic interaction between the transmission grid and distribution grids, and increased modeling complexity. Although specialized software exists to precisely model different components of the power system, it is far from trivial to integrate all various models and perform a holistic simulation. Instead of replicating all models in a common simulation program, a commonly accepted approach to tackle this model diversity is to couple third-party simulators and models through a co-simulation platform that coordinates information exchange among the various components. Following this line of research, this project’s objective was to develop a co-simulation platform based on a widely accepted industrial standard called Functional Mockup Interface (FMI). Within this process, the project developed models compliant with the FMI standard, called Functional Mockup Units (FMUs), and used them to perform various operational and planning power system analyses. Relying and building upon an industrial standard is the main differentiation of this project compared with previous or parallel efforts in the co-simulation area. Particular emphasis was put on delivering software utilities to facilitate setting up and running co-simulations by end-users. Furthermore, a strong aspect of this project is demonstrating that co-simulation techniques can be used to perform Hardware-in-the-Loop (HIL) simulations that couple software components (e.g., simulated models) with hardware components (e.g., real devices such PV systems and batteries). The long-term goal of CyDER project is to help establish FMI as a powerful standard for co-simulation and promote adoption by electric utilities and other interested stakeholders. The main accomplishments of the project include the development of several FMUs including distribution and transmission grid models, PV inverters with Volt/Var/Watt controllers, batteries, and predictive optimal controllers. Additionally, a unique software package was developed, called SimulatorToFMU, which is capable of exporting any Python-driven simulator or Python script as an FMU. This is an important contribution towards establishing FMI as one of the main co-simulation standards, because more and more third-party programs for sub-system modeling and simulation are delivered with Python APIs. The CyDER platform was used to perform PV hosting capacity analyses in real utility feeders with and without smart inverter controls, battery storage, and EV charging. Smart inverter controls include conventional Volt/Var/Watt controls for reactive power support and active power curtailment, but also predictive controls that optimize the charging and discharging profile of the battery connected on the DC side in order to minimize the customer’s economic benefit. Finally, an important result of this project is delivering an experimental setup that consists of residential-scale PV inverters with battery storage, a real-time grid simulator with an ideal voltage source as grid emulator, and micro Phasor Measurement Units (PMUs). All these components and additional software modules are coupled to one another using the FMI standard and can be co-simulated with the CyDER platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning with Adaptive Conservativeness for Distributionally Robust Optimization: Incentive Design for Voltage Regulation

Information asymmetry between the Distribution System Operator (DSO) and Distributed Energy Resource Aggregators (DERAs) obstructs designing effective incentives for voltage regulation. To capture this effect, we employ a Stackelberg game-theoretic framework, where the DSO seeks to overcome the information asymmetry and refine its incentive strategies by learning from DERA behavior over multiple iterations. We introduce a model-based online learning algorithm for the DSO, aimed at inferring the relationship between incentives and DERA responses. Given the uncertain nature of these responses, we also propose a distributionally robust incentive design model to control the probability of voltage regulation failure and then reformulate it into a convex problem. This model allows the DSO to periodically revise distribution assumptions on uncertain parameters in the decision model of the DERA. Finally, we present a gradient-based method that permits the DSO to adaptively modify its conservativeness level, measured by the size of a Wasserstein metric-based ambiguity set, according to historical voltage regulation performance. The effectiveness of our proposed method is demonstrated through numerical experiments.

adaptation models↗

Network Constraints Consideration for Grid-Edge Energy Management System

Increased deployment of distributed energy resources (DER) in distribution system is bringing need for enhanced grid intelligence, control, and flexibility. This is significant at the edge of the grid where DERs, loads or microgrids are located. Integrated DERs in a distribution system need to follow grid codes to avoid violations that results in DER disconnection. To comply with grid code requirements (e.g. IEEE 1547-2018) at the grid edge level, network constrained grid edge energy management system (GEEMS) is proposed in this paper. The objective of GEEMS is to provide economic solution for active and reactive power dispatch set-points at each interval and ensure voltage regulation to support secure interconnection of the grid edge segment to the distribution system. To evaluate the proposed GEEMS framework, four DERs are included into IEEE 13 bus system. GEEMS outperforms the existing economic dispatch-based energy management system by reducing the voltage violation.

Electric vehicle depot charging station↗

Grid-Connected Self-Synchronous Cascaded H-Bridge Inverters with Autonomous Power Sharing: Preprint

Cascaded inverters are widely applied in applications where elevated ac voltages are required while using semiconductor devices with lower voltage ratings. Here, we focus on structures that require localized power transfer between low-voltage sources/loads dispersed across inverter dc links and the inverter ac-sides are series-connected across a three-phase medium-voltage ac grid. To date, decentralized controllers that allow for bi-directional power transfer in such systems are limited. To fill this gap, we propose a virtual oscillator controller which modulates the power processed by each inverter in a purely decentralized manner.

autonomous power sharing↗

Heuristic Dynamic Programming for Adaptive Virtual Synchronous Generators

In this paper a neural network heuristic dynamic programing (HDP) is used for optimal control of the virtual inertia-based control of grid connected three-phase inverters. It is shown that the conventional virtual inertia controllers are not suited for non-inductive grids. A neural network-based controller is proposed to adapt to any impedance angle. Applying an adaptive dynamic programming controller instead of a supervised controlled method enables the system to adjust itself to different conditions. The proposed HDP consists of two subnetworks: critic network and action network. These networks can be trained during the same training cycle to decrease the training time. The simulation results confirm that the proposed neural network HDP controller performs better than the traditional direct-fed voltage and/or reactive power controllers in virtual inertia control schemes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power-Hardware-in-the-Loop Experiments of a Microgrid with a Grid-Forming Battery Inverter

Microgrids continue to proliferate, and they are transitioning away from using conventional generating resources to increasingly relying on inverter-based resources (IBRs) as the voltage and frequency leaders. It is crucial to evaluate the capability of IBRs to provide microgrid stability and resilience. Hardware-in-the-loop (HIL) experiments were conducted to de-risk the field deployment of the San Diego Gas & Electric Company Borrego Springs Microgrid, where a battery inverter was upgraded with grid-forming (GFM) capability to serve as the island leader. This paper presents the HIL experimental results from an HIL test bed that uses a power-hardware-in-the-loop (PHIL) interface with a power inductor that was previously developed for PHIL simulations of microgrids where the inverters need to switch modes, i.e., between grid-following and GFM as the microgrid transitions between grid-connected and islanded operation. This paper presents more details on the interface and HIL simulation results of the planned islanding and load steps in islanded operation to show the effectiveness of the inverters in managing the voltage and frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact Analysis of Data Integrity Attacks on FACTS-based Wide-Area Voltage Control System

Energy management system (EMS) consists of several wide-area control applications that serve as a backbone for security, stability, and reliability of the power system. Wide-area voltage control system (WAVCS), one of the critical wide-area applications, operates in coordination with local Flexible AC Transmission System (FACTS) devices to provide voltage security and optimal management of active and reactive power resources. Since the WAVCS relies on wide-area communication and data sharing devices, possible cybersecurity vulnerabilities have to be addressed to ensure the closed-loop operation of WAVCS. In this paper, we present a methodology for performing an impact analysis of cyber-attacks in WAVCS cybersecurity. In particular, different types of data integrity attacks, such as malicious tripping, fault replay, and signal altering attacks, are considered, and detailed impact analysis is conducted in a testbed environment using the Kundur's four machine two-area system. For performing an impact analysis, the transient voltage stability of the sensitive bus voltage is studied, followed by the quantitative assessment and severity ranking using the voltage profile index. Our experimental evaluation reveals that the data integrity attacks on control signals exhibit a higher attack severity than on the measurement signals. Further, the severity of these attacks varies with nature (static or dynamic), location, and types of attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Use of Grid-Forming Medium-Voltage Power Electronics Hub in a Microgrid Setting

This paper presents the application of a new design of a multiport, modular, medium-voltage power electronics hub (M3PE-HUB) in a microgrid setting. The M3PE-HUB system was modeled in a digital real-time simulator (DRTS) and integrated into the Banshee microgrid test system. This paper presents the preliminary DRTS simulation-based results of the M3PE-HUB system connected in a test microgrid system. Verification and validation of the M3PE-HUB architecture and controls in the test microgrid setting are the primary contributions of this work. The results of the operation during the islanding and resynchronization process indicate the feasibility of the proposed architecture in a microgrid setting. This paper also presents results for a system reconfiguration use case where the M3PE-HUB was used to reconfigure the system under a fault condition.

grid forming↗

Interpretable Data-Driven Probabilistic Power System Load Margin Assessment with Uncertain Renewable Energy and Loads

The increasing uncertainties caused by the high-penetration of stochastic renewable generation resources poses a significant threat to the power system voltage stability. To address this issue, this paper proposes a probabilistic deep kernel learning enabled surrogate model to extract the hidden relationship between uncertain sources, i.e., wind power and loads, and load margin for probabilistic load margin assessment (PLMA). Unlike other deep learning approaches, a kernel SHAP provides the sensitivity analysis as well as interpretability of the inputs to outputs influences. This allows identifying the critical factors that affect load margin so that corrective control can be initiated for stability enhancement. Numerical results carried out on the IEEE 118-bus power system demonstrate the accuracy and efficiency of the proposed data-driven PLMA scheme.

deep kernel learning↗