Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distribution monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Electrochemical Characterization of Bromine Reduction to Tribromide in Individual Nitrobenzene-in-Water Emulsion Droplets

We report an electrochemical study of bromine reduction to tribromide in a single nitrobenzene (NB) droplet during a single collision event. The feasibility of this study is based on the favorable distribution of Br 2 in NB rather than in water, which was demonstrated by voltammetry at the NB/water interface. The NB-in-water emulsions containing the ionic liquids trihexyltetradecylphosphonium bis(trifluoromethylsulfonyl)amide (ILPA) as the supporting electrolyte and sodium dodecyl sulfate (SDS) as the surfactant were prepared by a high-power ultrasonication. Its single droplet as an attoliter reactor, colliding on a 25 μm Pt UME, was monitored by chronoamperometry. The spike-type current transients of Br 2 reduction can elucidate the size and size distribution of NB, and measure the diffusion in the droplet as analyzed by a bulk electrolysis model. The frequency of collisions can provide diffusion coefficient of the droplets to the UME. Moreover, the i-t decay behavior can be simulated, which fits well with the experimental one.

25 ENERGY STORAGE↗

Online Detection of Inter-Turn Winding Faults in Single-Phase Distribution Transformers Using Smart Meter Data

Turn-to-turn faults between primary windings due to insulation degradation are a major cause of distribution transformer failure, and occur due to high levels of stress such as overloading and overheating. An additional consequence of these faults is an increased voltage on the transformer secondary due to effective change in turns ratio. This paper develops a novel method for early detection of insulation degradation and subsequent inter-turn winding failure by monitoring the transformer secondary voltage. The algorithm is based on a cumulative sum (CUSUM) statistic and compares voltages on neighbouring transformers to flag degrading assets. Results obtained from simulation as well as experimental data show that smart meter measurements can be utilized to achieve very high detection accuracy while keeping costs low. Here, the paper also demonstrates the validity of the algorithm in the presence of measurement noise, residential solar power injection etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity for the Operational Technology Environment (CyOTE) (Final Technical Report)

Electric grids have historically been susceptible to both physical attacks and environmental hazards but the implementation of smart grids, remote management, and self-healing networks, has now made the grid vulnerable to cyber attacks. To address risks introduced by routable connectivity, utilities must establish dynamic solutions to identify, protect, detect, respond to, and recover from cyber security threats and vulnerabilities. In response to the evolving threat landscape U.S. Department of Energy-Office of Cybersecurity, Energy Security, and Emergency Response (DOE CESER) initiated the Cybersecurity for the OT Environment (CyOTE) pilot program, a U.S. Department of Energy (DOE) effort designed to leverage U.S. intelligence capabilities to prevent, detect, or mitigate a cyber attack on utility operational technology (OT) networks. As part of the CyOTE pilot, The Southern Company (Southern Company or Southern) researched, evaluated and deployed emerging Commercial off the Shelf (COTS) technologies and cyber security monitoring architectures to provide previously unrealized network visibility and situational awareness through deep packet inspection and data analytics. This Final Scientific/Technical Report documents the objectives, methodology, lessons learned, and results of Southern Company’s participation in the CyOTE pilot from December 2018 to September 2023.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multiwell Fiber Optic Sensing Reveals Effects of CO2 Flow on Triggered Seismicity

Induced seismicity is one of the main risks for gigaton-scale geological storage of carbon dioxide (⁠CO 2 ⁠). Thus, passive seismic monitoring is often recommended as a necessary component of the monitoring systems for CO 2 storage projects, with a particular forcus on risk mitigation. We present the first field study, CO2CRC Otway Project Stage 3 (Victoria, Australia), where distributed acoustic sensing (DAS) enabled high-precision tracking of the induced seismicity triggered by a small CO 2 injection and also informed the reservoir models. In 610 days of passive seismic monitoring of the Stage 3 injection, we detected 17 microseismic events (maximum moment magnitude Mw 0.1) using five deep boreholes equipped with enhanced-sensitivity optical fiber. The DAS array has sensitivity sufficient for detection and location of induced events with M w ~ ₋2 in a monitoring borehole located up to 1500 m away. Thanks to the dense spatial sampling by the DAS, we were able to estimate the focal mechanisms for events with M w > ₋1.5; although the monitoring boreholes provided very limited angular coverage. The main cluster of the events has the same location and source mechanism as the one triggered by the previous CO 2 injection at the Otway Project site, Stage 2C. Surprizingly, the Stage 2C and Stage 3 events closely followed the actual movement of the CO 2 saturation plume front (not the pressure front), as observed using controlled-source reflection seismic images. The nature of the plume-fault interaction remains unclear, but some alteration of the fault gouge by CO 2 might be responsible for the faults’ reactivation by the pressure perturbation. Importantly, the seismogenic fault could not be identified in the seismic images and was only revealed by DAS observations, which also demonstrated the signature of fluid–rock interaction, that may control the CO 2 flow.

58 GEOSCIENCES↗

Smart Meters Enabling Voltage Monitoring and Control Functionalities: The Last-Mile Voltage Stability Issue

It is a demanding yet challenging task to design the next generation of smart meters. This work investigates the new voltage monitoring and control function for the next-generation smart meters, and identifies its added values for power system voltage stability issues. In terms of voltage monitoring, the risk benefit analysis for adding voltage magnitudes to smart meter measurements is presented, and the risk mitigation strategies along with the co-simulation validation via GridLAB-D and NS-3 are proposed, all providing insight into the new function evaluation. In terms of voltage control, a new voltage stability control scheme is developed, which uses voltage measurements from smart meters and utilizes the observability and controllability of distributed energy resources and controllable loads. Different from traditional voltage control schemes focusing on voltage regulation and power quality monitoring from the utility perspective, the proposed control scheme can achieve the maximum real power transfer margin at the end user side, enabling the voltage stability issues being solved at the grid edge, i.e. the last-mile segment. It is the first work that considers voltage monitoring and control collectively for smart meter investment. It can help power engineering community supplement smart meter applications and shape the next-generation smart meters.

42 ENGINEERING↗

Quantitative interpretation of time-lapse seismic data at Farnsworth field unit: Rock physics modeling, and calibration of simulated time-lapse velocity responses

Here, this study investigates the contribution of fluid saturation variation to the time-lapse velocity response by performing fluid substitution modeling. The methodology is exemplified by the time-lapse seismic monitoring of carbon dioxide at Farnsworth field unit (FWU). In order to evaluate the fluid distribution in a matured oil reservoir, the Southwest Regional Partnership (SWP) acquired multiple vertical seismic profile (VSP) surveys at different times during the CO 2 –water alternatinggas (WAG) injection period. In this work, we present a thorough methodology for computing the elastic response of the saturated rock for different fluid saturations using a site-specific petro-elastic model (PEM). The output from the PEM was combined with results from a fluid compositional model to compute the seismic velocities at times corresponding to each VSP survey. To produce a calibrated simulated response, the measured time-lapse seismic velocities were integrated into the numerical simulation model. The mismatches between the predicted and measured time-lapse velocities were minimized through an iterative calibration process using a trained artificial neural network proxy (ANN) coupled with a particle swarm optimizer (PSO). Our study indicates that the hybrid optimization workflow can effectively perform the history matching. With an accurate prediction of the hydrodynamic properties, the migration of CO 2 within the subsurface was modeled by predicting the spatial velocity distribution for a radius of 305 m around the injection well. The technology demonstrated and the expertise gained from this study can guide similar CO 2 -WAG projects.

58 GEOSCIENCES↗

Rapid Refreezing of a Marginal Ice Zone Across a Seafloor Distributed Acoustic Sensor

Abstract Seismic instruments such as broadband seismometers and distributed acoustic sensors (DAS) have a demonstrated potential for wide‐scale and continuous in situ monitoring of near‐surface environmental and anthropogenic processes. DAS is attractive for development as a multi‐geophysical observatory due to the prevalence of existing fiber infrastructure in regions with environmental, cultural, or strategic significance. Here we present results from a multi‐seasonal acquisition of DAS data on a seafloor cable in the Beaufort Sea, Alaska. During a November 2021 data collect we captured the rapid transition of ambient noise characteristics from an “ice‐free” state to an “ice‐bound” state. A sea ice formation front was plainly visible on the DAS record and was observed to propagate 20 km seaward over a period of 8 hr. Satellite‐based instrumentation were unable to record this event due to cloud cover, low light conditions, and orbital frequency.

Baker, Michael G.↗

Synchronous detection of cosmic rays and correlated errors in superconducting qubit arrays

Quantum information processing at scale will require sufficiently stable and long-lived qubits, likely enabled by error-correction codes. Several recent superconducting-qubit experiments, however, reported observing intermittent spatiotemporally correlated errors that would be problematic for conventional codes, with ionizing radiation being a likely cause. Here, we directly measured the cosmic-ray contribution to spatiotemporally correlated qubit errors. We accomplished this by synchronously monitoring cosmic-ray detectors and qubit energy-relaxation dynamics of 10 transmon qubits distributed across a 5 × 5 × 0.35 mm 3 silicon chip. Cosmic rays caused correlated errors at a rate of $1/\left(592\begin{array}{c}+48\\ -41\end{array}\,{\rm{s}}\right)$, accounting for 17.1 ± 1.3% of all such events. Our qubits responded to essentially all of the cosmic rays and their secondary particles incident on the chip, consistent with the independently measured arrival flux. Moreover, we observed that the landscape of the superconducting gap in proximity to the Josephson junctions dramatically impacts the qubit response to cosmic rays. Given the practical difficulties associated with shielding cosmic rays, our results indicate the importance of radiation hardening—for example, superconducting gap engineering—to the realization of robust quantum error correction.

Science & Technology - Other Topics↗

CRAGE-mediated insertion of fluorescent chromosomal markers for accurate and scalable measurement of co-culture dynamics in Escherichia coli

Monitoring population dynamics in co-culture is necessary in engineering microbial consortia involved in distributed metabolic processes or biosensing applications. However, it remains difficult to measure strain-specific growth dynamics in high-throughput formats. This is especially vexing in plate-based functional screens leveraging whole-cell biosensors to detect specific metabolic signals. Here, we develop an experimental high-throughput co-culture system to measure and model the relationship between fluorescence and cell abundance, combining chassis-independent recombinase-assisted genome engineering (CRAGE) and whole-cell biosensing with a PemrR-green fluorescent protein (GFP) monoaromatic reporter used in plate-based functional screening. CRAGE was used to construct Escherichia coli EPI300 strains constitutively expressing red fluorescent protein (RFP) and the relationship between RFP expression and optical density (OD600) was determined throughout the EPI300 growth cycle. A linear equation describing the increase of normalized RFP fluorescence during deceleration phase was derived and used to predict biosensor strain dynamics in co-culture. Measured and predicted values were compared using flow cytometric detection methods. Induction of the biosensor lead to increased GFP fluorescence normalized to biosensor cell abundance, as expected, but a significant decrease in relative abundance of the biosensor strain in co-culture and a decrease in bulk GFP fluorescence. Taken together, these results highlight sensitivity of population dynamics to variations in metabolic activity in co-culture and the potential effect of these dynamics on the performance of functional screens in plate-based formats. The engineered strains and model used to evaluate these dynamics provide a framework for optimizing growth of synthetic co-cultures used in screening, testing and pathway engineering applications.

59 BASIC BIOLOGICAL SCIENCES↗

Using AI for Management of Field Emission in SRF Linacs

Field emission control, mitigation, and reduction is critical for reliable operation of high gradient superconducting radio-frequency (SRF) accelerators. With the SRF cavities at high gradients, the field emission of electrons from cavity walls can occur and will impact the operational gradient, radiological environment via activated components, and reliability of CEBAF’s two linacs. A new effort has started to minimize field emission in the CEBAF linacs by re-distributing cavity gradients. To measure radiation levels, newly designed neutron and gamma radiation dose rate monitors have been installed in both linacs. Artificial intelligence (AI) techniques will be used to identify cavities with high levels of field emission based on control system data such as radiation levels, cryogenic readbacks, and vacuum loads. The gradients on the most offending cavities will be reduced and compensated for by increasing the gradients on least offensive cavities. Training data will be collected during this year’s operational program and initial implementation of AI models will be deployed. Preliminary results and future plans are presented.

Carpenter, Adam↗

Using AI for Management of Field Emission in SRF Linacs

Field emission control, mitigation, and reduction is critical for reliable operation of high gradient superconducting radio-frequency (SRF) accelerators. With the SRF cavities at high gradients, the field emission of electrons from cavity walls can occur and will impact the operational gradient, radiological environment via activated components, and reliability of CEBAF’s two linacs. A new effort has started to minimize field emission in the CEBAF linacs by re-distributing cavity gradients. To measure radiation levels, newly designed neutron and gamma radiation dose rate monitors have been installed in both linacs. Artificial intelligence (AI) techniques will be used to identify cavities with high levels of field emission based on control system data such as radiation levels, cryogenic readbacks, and vacuum loads. The gradients on the most offending cavities will be reduced and compensated for by increasing the gradients on least offensive cavities. Training data will be collected during this year’s operational program and initial implementation of AI models will be deployed. Preliminary results and future plans are presented.

Carpenter, Adam↗

The ETROC2 as the Final Version for CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD (Low Gain Avalanche Diodes) silicon devices, read out by ETROCs for precision timing measurement with down to ~30 ps timing resolution per track. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. The front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile. The ETROC chip is implemented in a commercial 65nm CMOS process. Each channel consists of a preamplifier, a discriminator, a TDC used for TOA (Time Of Arrival) and TOT (Time Over Threshold) measurements, and a memory for data storage and readout. An in-pixel auto threshold calibration is included, along with a self-testing pattern generator. The TOT is used for time-walk correction of the TOA measurement. The detailed hit information (TOA and TOT) from each cell will be read out from a local circular buffer after each Level-1 Accept (about 1 MHz). In addition, a charge injection circuit is implemented to allow for testing and calibration. For more detailed monitoring of the signal pulses, waveform sampling circuits are included for one pixel. The clock distribution is based on a 16x16 H-tree design with a shielding structure to alleviate potential interference. The global peripheral circuits include a PLL, a phase shifter, an I2C slave controller, a fast control block, a global readout, and a data driver along with an efuse and temperature sensor. The ETROC builds event data frames for each L1A selected event and is also capable of providing L1 trigger information for user-defined delayed hits. The main design challenge is how to extract precision timing information from the small LGAD signals in the presence of high irradiation fluence, while keeping the power consumption and digital activity low. The ETL design goal for the time resolution of 50 ps per hit is required to achieve a 35 ps arrival time measurement for a MIP particle, which has its track registered in two ETL disk layers. The LGAD contribution is known to be about 30 ps, this means that the jitter from the ETROC has to be kept below 40 ps. The ETROC2 is the first full size full functionality prototype design fully compatible with the final chip specifications for CMS ETL and now becomes the final version. The ETROC2 chips have been extensively tested. We will present here new testing results including the bump bonding yield improvement study, the time walk correction (TWC) generality study with one pixel TWC applying to all pixels, the final SEU testing using both heavy ion and proton beam, more beam test studies including different sensors, and readiness for the ETROC2 production for CMS ETL upgrade.

Liu, Tiehui [Fermilab] (ORCID:0009000765225605)↗

Controlling $H_{3}^{+}$ Formation From Ethane Using Shaped Ultrafast Laser Pulses

An adaptive learning algorithm coupled with 3D momentum-based feedback is used to identify intense laser pulse shapes that control $H_{3}^{+}$ formation from ethane. Specifically, we controlled the ratio of D 2 H + to $D_{3}^{+}$ produced from the D 3 C-CH 3 isotopologue of ethane, which selects between trihydrogen cations formed from atoms on one or both sides of ethane. We are able to modify the D 2 H + :$D_{3}^{+}$ ratio by a factor of up to three. In addition, two-dimensional scans of linear chirp and third-order dispersion are conducted for a few fourth-order dispersion values while the D 2 H + and $D_{3}^{+}$ production rates are monitored. The optimized pulse is observed to influence the yield, kinetic energy release, and angular distribution of the D 2 H + ions while the $D_{3}^{+}$ ion dynamics remain relatively stable. We subsequently conducted COLTRIMS experiments on C 2 D 6 to complement the velocity map imaging data obtained during the control experiments and measured the branching ratio of two-body double ionization. Two-body $D_{3}^{+}$ + $C_{2}D_{3}^{+}$ is the dominant final channel containing $D_{3}^{+}$ ions, although the three-body D + $D_{3}^{+}$ + $C_{2}D_{2}^{+}$ final state is also observed.

74 ATOMIC AND MOLECULAR PHYSICS↗

TrustDER: Trusted, Private and Scalable Coordination of Distributed Energy Resources

In this project, the Stanford and SLAC Teams have developed a Trusted, Private and Scalable platform for coordinating Coordination of Distributed Energy Resources (TrustDER). This is a layered system that ensures private, trusted and scalable coordination and monitoring of DERs. It accommodates a variety of resources, such as solar generation, gensets and loads, with a particular focus on battery systems-based resources, as they are a transformational technology experiencing fast growth in adoption by large critical facilities. The platform can be used as standalone or added to existing aggregation systems to enable trust, privacy and resilience. TrustDER consists of layers that address each of the shortcomings of the existing state of the art. Each layer in the platform can operate independently but provides information to the layers above it to enable a novel form of overall coordination architecture. The project consists of several tasks, with each task dedicated to the design of each layer. Task 2 Resource Virtualization defined a software abstraction layer for distributed energy resources (DERs). The goal of this abstraction was to simplify the implementation of algorithms utilizing cooperation of DERs resources in a variety of use cases. Task 3 is on Secure ID for Asset Authentication. Identity Management Systems (IDMS) are a foundational infrastructure for interactions between entities (organizations, users, devices, and services). Secure ID is blockchain-based a distributed identity management system allowing (1) identity provisioning, (2) authentication, (3) authorization, and (4) identity data sharing for IoT-enabled assets on the electricity grid. In this project, the SLAC team focused on designing and testing Keymaker, a protocol for authenticating device identity managed by Secure ID. Task 5 Private and Safe Integration is focused on the design and evaluation of a DER cooperation scheme which allows for the aggregation of DERs without impacting network reliability. The approach is designed based on realistic assumptions regarding data availability, communication infrastructure limitations, and privacy. Task 6 Scalable Distributed Privacy for Information explored how virtualized batteries could be managed privately. Specifically, it examined the case in which a principal provides a partitioned battery to multiple clients. Task 7 Use Cases was to ensure that this technology was applied in relevant situations and scenarios. Primarily, this means that virtualization needed to be employed in a manner that either improved flexibility, bolstered security or privacy, or decreased costs.

25 ENERGY STORAGE↗

The impact of sampling scale: A comparison of methods for estimating external contaminant exposure in free-ranging wildlife

The impacts of contaminants on wildlife are dose dependent, and thus being able to track or predict exposure following contamination events is important for monitoring ecosystem health. However, the ability to track exposure in free-ranging wildlife is often severely limited. Consequently, researchers have predominantly relied on simple methods for estimating contaminant exposures in wildlife with little regard for spatial contaminant heterogeneity or an animal’s use of diverse habitats. We evaluated the influence sampling scale (i.e., how finely contaminant distribution and organism’s spatial use of the landscape is mapped) has on (1) realism and (2) conservativeness of exposure estimates. To do this, we monitored the actual exposure of wild boar (Sus scrofa) in Fukushima, Japan to radioactive contamination using GPS27 coupled contaminant monitors placed on individual animals. We compared empirical exposures to estimates generated by combining varying amounts of information about an individual boar’s location and/or movement, with the distribution of contamination on the landscape. Here we found that the most realistic exposure estimates were produced when finer-scale contaminant distribution surveys (e.g., airborne surveys) were combined with more accurate estimates of an individual’s space use (e.g., home ranges or core areas). Importantly, estimates of exposure based on single point surveys at a trap site (a simple method commonly used in the literature), did not correlate with actual exposure rates, suggesting dose-effects studies using this method may result in spurious conclusions. These results suggest that researchers seeking realistic estimates of exposure, such as in dose-effect studies, should ensure they have adequately accounted for fine-scale contaminant distribution patterns and areas of higher use by study organisms. However, conservative estimates of exposure i.e., intentionally over-predicting exposure as is done in initial tiers of ecological risk analyses) were not as scale sensitive and could be achieved with a single known location and coarse contaminant distribution maps.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Copula based Damage Detection for Structural Health Monitoring

This project utilizes copulas for damage detection in a Structural Health Monitoring (SHM) application. A copula-based system was chosen for the benefit of multivariate joint distribution with a goal to detect damage based on how the system as a whole reacts rather than one or two sensors by themselves. Copulas are commonly used in the field of finance for risk modeling based on two or more random inputs. A few applications in the field of SHM and Non-Destructive Evaluation (NDE) have been researched mostly on risk or reliability of the structure. The goal of this project is to determine if a copula-based approach can be used for damage detection. An unsupervised learning method was desired to reduce the dimensionality, minimal training, and be a faster evaluation method than other unsupervised methods. If a copula method can be used to detect damage what additional information on the damage can be interpreted. The remainder of this report will go over the background needed, SHM methodology, SHM applications, conclusions, and future developments.

47 OTHER INSTRUMENTATION↗

AC and DC Hybrid Distribution Grids with Solar Integration: Architecture, Stabilization and Cost Assessment

In this project, a holistic analysis of architecture, stabilization, and cost/efficiency analysis in hybrid AC and DC distribution grids are conducted. Particularly, versatile and cost-efficient multiport converters are developed to not only integrate solar sources and other DERs in DC grids, but also facilitate the interactive operation of DC sub-grids and conventional AC distribution grids. Meanwhile, a universal and extended impedance-based stabilization approach with a decentralized and adaptive virtual impedance loop is developed in hybrid AC and DC distribution grids, which comprehensively covers the active stabilization of DC sections, AC sections, and interface inverters interlinking both AC and DC sections. Furthermore, to quantitatively evaluate the cost and efficiency of hybrid AC and DC distribution grids and quantify the improvement of hybrid AC and DC grids over conventional pure AC grids, the project team develops an alpha-version tool to monitor and calculate the efficiency and cost of the DC, AC, or hybrid AC and DC grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Minimum Detectable Quantity Calculation for Radiation Portal Monitors

The minimum detectable quantity of a radiation portal monitor is the smallest amount of radioactive material that can be detected passing through the monitor (with a specified detection probability). The minimum detectable quantity is a function of many factors, including isotope, velocity, distance between pillars, height of portal and vehicle, source distribution and position, background radiation, background suppression, detector volume and positions, detector efficiency, decision metrics and algorithms, the presence of NORM (naturally occurring radioactive material), and alarm thresholds. Experimentally testing a radiation portal monitor to failure for all combinations of these factors is extremely time-consuming and often cost prohibitive. This document outlines a straightforward method for quickly estimating the minimum detectable quantity for moving sources over a large variety of conditions with a minimal number of static measurements. The document also describes a proof of concept software application that the International Atomic Energy Agency has designed based on the described method that can be used by Member States to estimate a monitor’s minimum detectable quantity.

Blessinger, Christopher S.↗