Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

CMOS detector cells for holographic optical interconnects in microcircuits

This paper reports on the characterization of CMOS detectors for holographic optical interconnects in micro circuits. A VLSI temporal response system has been built, which has high-magnification viewing capabilities to facilitate the identification of the sample area under investigation. An isolated photodiode and load circuit has been characterized to determine responsivity, response time, and light spot positioning effects. The threshold of optical gate cells incorporating the above detectors and a transistor inverter stage to couple to other circuitry has been determined. The rise time and fall time of the optical gate cells have also been determined experimentally. The results were compared with the results of SPICE simulation, and show satisfactory agreement. The time delay of optical gate cell output was thus determined to be 70 ns at 10 microW light input. Threshold power was 0.5 microW light input.

Wu, W. H.↗

Visualization of Microbial Biomarkers by Scanning Electron Microscopy

We are developing tools to link the biochemical structure of selected biomarkers with putative biogenic structures observed in mineralized samples. The detection of evidence of life on Mars and other planets will rely on methods that can discriminate compounds formed exclusively by living organisms. While biogenic compounds, such as amino acids and nucleotides have been discovered in extraterrestrial sources, such as meteorites and comets, their formation can be explained by abiotic means. The formation of cellular structures, or more elaborate organic molecules, such as complex lipids, proteins or nucleic acids, however, is strongly correlated to the presence of even the most primitive life processes. Recent evidence lends support to the hypothesis that life may have once existed on Mars. Carbonate globules and ppm concentrations of polycyclic aromatic hydrocarbons (PAHs) have been described in ALH84001, a meteorite originating from Mars ejecta captured by Earth over 13,000 years ago. The localized high concentration of PAHs that follow an increasing gradient from the intact fusion crust towards the interior corresponds to microgram quantities of hydrocarbon. Even though ALH84001 and other similar meteorites have withstood the forces capable of ejecting rock through Mars' escape velocity, upon entering Earth's atmosphere, their core temperatures are likely not to have been raised significantly, as evidenced by the survival of remanent magnetic signatures. Ideal biomarkers of ancient or modern biological life would include molecules that are (or were) pervasive and highly resistant to degradation. Also, requisite methods of detection should be simple, extremely sensitive and broadly inclusive (NASA SP-530). Lipopolysaccharide (LPS), peptidoglycan or pseudopeptidoglycan and beta-glucan are microbial cell wall components which together cover the entire microbial spectrum of eubacteria, archea and fungi. They are all remarkably resistant to thermal degradation. Fortunately, many antimicrobial defense systems of higher organisms require sensitive detection to combat microbial pathogens. We employ here the primitive immune system of the evolutionarily ancient horseshoe crab, Limulus polyphemus. This species relies on multi-enzyme signal amplification detection of cell wall molecules and they can be applied to the development of useful detectors of life. An extension of this work includes the visualization of microbial signatures by labeling LAL components with chromogenic or electron dense markers. The protein Limulus Anti-LPS Factor (LALF) has an extremely high affinity for LPS. By coupling LALF binding with colloidal gold labels we demonstrate a correlation of the structures visible by electron microscopy with biochemical evidence of microbial cell wall materials. Pure silica particles were mixed with cultures of E. coli (10(exp 6) cfu/mL). Samples were washed sequentially with buffered saline, LALF, antibody to LALF and finally colloidal gold-labeled Protein A. Negative controls were not exposed to E. coli but received identical treatment otherwise. Samples were coated with carbon and imaged on a JEOL JSM-840 scanning electron microscope with LaB6 source in the back scatter mode with the JEOL annular back scatter detector. 20 nm-scale black spots in this contrast-reversed image originate from electrons back-scattered by gold atoms. Negative controls did not give any signal. Future work will expand application of this technique to soil simulants and mineralized rock samples.

Wainwright, Norman R.↗

Technology Advancement for Active Remote Sensing of Carbon Dioxide from Space Using the ASCENDS CarbonHawk Experiment Simulator: First Results

The ASCENDS CarbonHawk Experiment Simulator (ACES) is a newly developed lidar developed at NASA Langley Research Center and funded by NASA's Earth Science Technology Office (ESTO) Instrument Incubator Program (IIP) that seeks to advance technologies critical to measuring atmospheric column carbon dioxide (CO2) mixing ratios in support of the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission. The technology advancements targeted include: (1) increasing the power-aperture product to approach ASCENDS mission requirements by implementing multi-aperture telescopes and multiple co-aligned laser transmitters; (2) incorporating high-efficiency, high-power Erbium-Doped Fiber Amplifiers (EDFAs); (3) developing and incorporating a high-bandwidth, low-noise HgCdTe detector and transimpedence amplifier (TIA) subsystem capable of long-duration autonomous operation on Global Hawk aircraft, and (4) advancing algorithms for cloud and aerosol discrimination. The ACES instrument architecture is being developed for operation on high-altitude aircraft and will be directly scalable to meet the ASCENDS mission requirements. These technologies are critical towards developing not only spaceborne instruments but also their airborne simulators, with lower platform requirements for size, mass, and power, and with improved instrument performance for the ASCENDS mission. ACES transmits five laser beams: three from commercial EDFAs operating near 1.57 microns, and two from the Exelis oxygen (O2) Raman fiber laser amplifier system operating near 1.26 microns. The three EDFAs are capable of transmitting up to 10 watts average optical output power each and are seeded by compact, low noise, stable, narrow-linewidth laser sources stabilized with respect to a CO2 absorption line using a multi-pass gas absorption cell. The Integrated-Path Differential Absorption (IPDA) lidar approach is used at both wavelengths to independently measure the CO2 and O2 column number densities and retrieve the average column CO2 mixing ratio. The ACES receiver uses three fiber-coupled 17.8-cm diameter athermal telescopes. The transmitter assembly consists of five fiber-coupled laser collimators and an associated Risley prism pair for each laser to co-align the outgoing laser beams and to align them with the telescope field of view. The backscattered return signals collected by the three telescopes are combined in a fiber bundle and sent to a single low noise detector. The detector/TIA development has improved the existing detector subsystem by increasing its bandwidth to 4.7 MHz from 500 kHz and increasing the duration of autonomous, service-free operation periods from 4 hours to >24 hours. The new detector subsystem enables the utilization of higher laser modulation rates, which provides greater flexibility for implementing advanced thin-cloud discrimination algorithms as well as improving range-determination resolution and error reduction. The cloud/aerosol discrimination algorithm development by Langley and Exelis features a new suite of algorithms for the minimization/elimination of bias errors in the return signal induced by the presence of intervening thin clouds. Multiple laser modulation schemes are being tested in an effort to significantly mitigate the effects of thin clouds on the retrieved CO2 column amounts. Full instrument development concluded in the spring of 2014. After ground range tests of the instrument, ACES successfully completed six test flights on the Langley Hu-25 aircraft in July, 2014, and recorded data at multiple altitudes over land and ocean surfaces with and without intervening clouds. Preliminary results from these test flights will be presented in this paper.

Obland, Michael D.↗

A New Method for Reduction of Photomultiplier Signal-Induced Noise

For lidar measurements of ozone, photomultiplier tube (PMT) detector signal-induced noise represents a fundamental problem that complicates the extraction of information from lidar data. A new method is developed to significantly reduce signal-induced noise in lidar receiver PMT detectors. The electron optics of the lidar photomultiplier detector is modified to filter the source of signal-induced noise. A mesh electrode external to the PMT is utilized to control photoemission and disorient electron trajectories from the photocathode to the first dynode. Experiments were taken both with simulated and actual lidar return signals at Langley Research Center. Results show at least 40 percent more accurate ozone number density values with a mesh voltage of 60 V applied than with no voltage applied.

Koble, Andrea↗

Analysis of High Contrast Imaging Techniques for Space Based Direct Planetary Imaging

We report on our ongoing investigations of a number of techniques for direct detection and imaging of Earth-like planets around nearby stellar sources. Herein, we give a quantitative analysis of these techniques and compare and contrast them via computer simulations. The techniques we will be reporting on are Bracewell Interferometry, Nisenson Apodized Square Aperture, and Coronagraphic masking techniques. We parameterize our results with respect to wavelength, aperture size, effects of mirror speckle, both mid- and high-spatial frequency, detector and photon noise as well pointing error. The recent numerous detections of Jupiter and Saturn like planets has driven a resurgence in research of space based high contrast imaging techniques for direct planetary imaging. Work is currently ongoing for concepts for NASA's Terrestrial Planet Finder mission and a number of study teams have been funded. The authors are members of one team.

Lyon, Richard G.↗

On Europa's Magnetospheric Interaction: A MHD Simulation of the E4 Flyby

The global three-dimensional interaction of Europa with the Jovian magnetosphere is modeled by using a complete set of ideal magnetohydrodynamic (MHD) equations. The model accounts for exospheric mass loading, ion-neutral charge exchange, recombination, and a possible intrinsic dipole magnetic field of Europa. The single-fluid MHD equations are solved by using a modem, finite volume, higher-order, Godunov-type method on an adoptively refined unstructured grid, which allows detailed modeling of the region near Europa while still resolving both the upstream region and the satellite's wake. The magnetic field and plasma density measured during Galileo's EGA flyby of December 19, 1996, are reproduced reasonably well in the simulation. We find the agreement between the data and our model particularly convincing if we assume that the plasma velocity during the EGA flyby deviated from the nominal corotation direction by approximately 20 deg. Evidence from the Galileo energetic particle detector also supports this assumption. In this case, we can fit the data using a dipole with orientation close to that of an induced dipole arising from the interaction of a hypothetical conducting subsurface layer on Europa with the periodically changing magnetic field of Jupiter. However, the magnitude of the dipole in our model is somewhat smaller (70%) than that suggested by Khurana et al. The total mass loading and ion-neutral charge exchange rates are consistent with the estimates of Europa's atmosphere and ionosphere.

Kabin, K.↗

The Impact of Crosstalk in the X-IFU Instrument on Athena Science Cases

In this paper we present a first assessment of the impact of various forms of instrumental crosstalk on the science performance of the X-ray Integral Field Unit (X-IFU) on the Athena X-ray mission. This assessment is made using the SIXTE end-to-end simulator in the context of one of the more technically challenging science cases for the XIFU instrument. Crosstalk considerations may influence or drive various aspects of the design of the array of high-count-rate Transition Edge Sensor (TES) detectors and its Frequency Domain Multiplexed (FDM) readout architecture. The Athena X-ray mission was selected as the second L-class mission in ESA's Cosmic Vision 2015–25 plan, with alaunch foreseen in 2028, to address the theme ''Hot and Energetic Universe"1. One of the two instruments on boardAthena is the X-ray Integral Field Unit2 (X-IFU) which is based on an array of ~3800 Transition Edge Sensors (TES's)operated at a temperature of ~90 mK. The science cases pose an interesting challenge for this instrument, as they requirea combination of high energy resolution (2.5 eV FWHM or better), high spatial resolution (5 arcsec or better) and highcount rate capability (several tens of counts per second per detector for point sources as bright as 10 mCrab).The performance at the single sensor level has been demonstrated3, but the operation of such detectors in an array, usingmultiplexed readout, brings additional challenges, both for the design of the array in which the sensors are placed and forthe readout of the sensors. The readout of the detector array will be based on Frequency Domain Multiplexing (FDM)4.In this system of detectors and readout, crosstalk can arise through various mechanisms: on the TES array, neighboringsensors can couple through thermal crosstalk. Detectors adjacent in carrier frequency may suffer from electrical crosstalkdue to the finite width of the bandpass filters, and shared sources of impedance in their signal lines. The signals from theindividual detectors are summed and then amplified by a pair of SQUID amplifiers before being sent to warm front-endelectronics. The transfer function of the SQUID amplifiers is non-linear, which will give rise to higher harmonics ofcarriers and intermodulation products when multiple signal pulses are simultaneously present in the SQUID. Under highcount rate conditions this is another source of crosstalk. The effect of all these crosstalk sources is that parasitic pulseswill appear in the record of a signal pulse which will create a stochastic offset of the measured energy and thus adegradation of the energy resolution.

SIXTE↗

A digital optical torquemeter for high rotational speed applications

A digital optical torquemeter system designed for applications at high rotational speeds was fabricated and tested for zero stability at speeds up to 20,000 rpm. Data obtained in a spin rig and with simulated inputs demonstrate that the system is capable of measuring torque bar twist to within 0.03 degrees at speeds of 30,000 rpm. The optical system uses fiber optic bundles to transmit light to the torque bar and to silicon avalanche detectors. The system is microcomputer based and provides measurements of average torque and torque as a function of angular shaft position. The torquemeter requires no bearings or other contact between the rotating torque bar and the nonrotating optics, and tolerates movement of the torque bar as large as 1 mm relative to the optics.

Lesco, D. J.↗

Nonthermal synchrotron radiation in a strong magnetic field

A synchrotron source model is presented for the origin of gamma-ray bursts from neutron stars. The field strength and length of time needed for electrons to lose sufficient energy in emitting the gamma rays are calculated, together with the efficiency of the process, limiting frequencies, and the energy output. A Monte Carlo simulation of the synchrotron radiation spectrum of an electron undergoing a self-consistent energy loss demonstrates that a process involving thermalized electrons can be sufficiently efficient to produce 30 keV gamma rays. Problems expected in using the current capabilities of detectors to scan for the projected energy spectra from fields of at least 3 x 10 to the 12th Gauss are discussed.

Bussard, R. W.↗

The polarization sensitivity of the liquid xenon imaging telescope

The properties and the expected performance of a liquid xenon (LXe) gamma-ray imaging telescope, optimized for the MeV energy region, are presented. The unique potential of this telescope as a Compton polarimeter is particularly emphasized. Based on Monte Carlo simulations, we show that the modulation factor is as high as 40% at 1 MeV with a detection efficiency close to 20%. These figures of merit, combined with the excellent background suppression capability of the three-dimensional position sensitive LXe detector, yield sensitivity at the 3 sigma level to polarization fractions as small as a few percent for strong sources, even in a balloon flight.

Aprile, E.↗

Meeting the Grand Challenge of Protecting Astronauts Health: Electrostatic Active Space Radiation Shielding for Deep Space Missions

This report describes the research completed during 2011 for the NASA Innovative Advanced Concepts (NIAC) project. The research is motivated by the desire to safely send humans in deep space missions and to keep radiation exposures within permitted limits. To this end current material shielding, developed for low earth orbit missions, is not a viable option due to payload and cost penalties. The active radiation shielding is the path forward for such missions. To achieve active space radiation shielding innovative large lightweight gossamer space structures are used. The goal is to deflect enough positive ions without attracting negatively charged plasma and to investigate if a charged Gossamer structure can perform charge deflections without significant structural instabilities occurring. In this study different innovative configurations are explored to design an optimum active shielding. In addition, to establish technological feasibility experiments are performed with up to 10kV of membrane charging, and an electron flux source with up to 5keV of energy and 5mA of current. While these charge flux energy levels are much less than those encountered in space, the fundamental coupled interaction of charged Gossamer structures with the ambient charge flux can be experimentally investigated. Of interest are, will the EIMS remain inflated during the charge deflections, and are there visible charge flux interactions. Aluminum coated Mylar membrane prototype structures are created to test their inflation capability using electrostatic charging. To simulate the charge flux, a 5keV electron emitter is utilized. The remaining charge flux at the end of the test chamber is measured with a Faraday cup mounted on a movable boom. A range of experiments with this electron emitter and detector were performed within a 30x60cm vacuum chamber with vacuum environment capability of 10-7 Torr. Experiments are performed with the charge flux aimed at the electrostatically inflated membrane structure (EIMS) in both charged and uncharged configurations. The amount of charge shielding behind and around the EIMS was studied for different combinations of membrane structure voltages and electron energies. Both passive and active shielding were observed, with active shielding capable of deflecting nearly all incoming electrons. The pattern of charge distribution around the structure was studied as well as the stability of the structures in the charge flow. The charge deflection experiments illustrate that the EIMS remain inflated during charge deflection, but will experience small amplitude oscillations. Investigations were performed to determine a potential cause of the vibrations. It is postulated these vibrations are due to the charge flux causing local membrane charge distribution changes. As the membrane structure inflation pressure is changed, the shape responds, and causes the observed sustained vibration. Having identified this phenomenon is important when considering electrostatically inflated membrane structures (EIMS) in a space environment. Additionally, this project included a study of membrane material impacts, specifically the impact of membrane thickness. Extremely thin materials presented new challenges with vacuum preparation techniques and rapid charging. The thinner and lighter membrane materials were successfully inflated using electrostatic forces in a vacuum chamber. However, care must be taken when varying the potentials of such lighter structures as the currents can cause local heating and melting of the very thin membranes. Lastly, a preliminary analysis is performed to study rough order of magnitude power requirements for using EIMS for radiation shielding. The EIMS power requirement becomes increasingly more challenging as the spacecraft voltage is increased. As a result, the emphasis is on the deflection of charges away from the spacecraft rather than totally stopping them. This significantly alleviates the initial power requirements. With modest technological development(s) active shielding is emerging to be a viable option.

Radiation↗

Magnetic Calorimeter Option for the Lynx X-Ray Microcalorimeter

One option for the detector technology to implement the Lynx x-ray microcalorimeter (LXM) focal plane arrays is the metallic magnetic calorimeter (MMC). Two-dimensional imaging arrays of MMCs measure the energy of x-ray photons by using a paramagnetic sensor to detect the temperature rise in a microfabricated x-ray absorber. While small arrays of MMCs have previously been demonstrated that have energy resolution better than the 3 eV requirement for LXM, we describe LXM prototype MMC arrays that have 55,800 x-ray pixels, thermally linked to 5688 sensors in “hydra” configurations, and that have sensor inductance increased to avoid signal loss from the stray inductance in the large-scale arrays when the detectors are read out with microwave superconducting quantum interference device multiplexers, and that use multilevel planarized superconducting wiring to provide low-inductance, low-crosstalk connections to each pixel. We describe the features of recently tested MMC prototype devices and simulations of expected performance in designs opti- mized for the three subarray types in LXM.

Stevenson, Thomas R.↗

Integrated detector array preprocessing for infrared astronomical applications

On-board preprocessing of astronomical data from integrated infrared detector arrays and discrete detectors will allow increases in sensitivity and reductions in costs for observations from cryogenic space telescopes. A variety of preprocessing functions for this application, which could be implemented either through analog on-chip devices or through external microprocessors, is identified. Software simulations and laboratory evaluations are underway to determine the effectiveness of these preprocessing schemes.

Mccreight, C. R.↗

Integrated infrared detector arrays for low-background astronomy

Existing integrated infrared detector array technology is being evaluated under low-background conditions to determine its applicability in orbiting astronomical applications where extended integration times and photometric accuracy are of interest. Preliminary performance results of a 1 x 20 elements InSb CCD array under simulated astronomical conditions are presented. Using the findings of these tests, improved linear- and area-array technology will be developed for use in NASA programs such as the Shuttle Infrared Telescope Facility. For wavelengths less than 30 microns, extrinsic silicon and intrinsic arrays with CCD readout will be evaluated and improved as required, while multiplexed arrays of Ge:Ga for wavelengths in the range 30 to 120 microns will be developed as fundamental understanding of this material improves. Future efforts will include development of improved drive and readout circuitry, and consideration of alternate multiplexing schemes.

Mccreight, C. R.↗

The polarization sensitivity of the liquid xenon imaging telescope

The properties and the expected performance of a liquid xenon (LXe) gamma ray imaging telescope, optimized for the MeV energy region, are presented. The unique potential of this telescope as a Compton polarimeter is particularly emphasized. Based on Monte Carlo simulations we show that the modulation factor is as high as 40 percent at 1 MeV with a detection efficiency close to 20 percent. These figures of merit combined with the excellent background suppression capability of the three dimensional position sensitive LXe detector yield sensitivity at the three sigma level to polarization fractions as small as a few percent for strong sources, even in a balloon flight.

Aprile, Elena↗

All-sky search in early O3 LIGO data for continuous gravitational-wave signals from unknown neutron stars in binary systems

Rapidly spinning neutron stars are promising sources of continuous gravitational waves. Detecting such a signal would allow probing of the physical properties of matter under extreme conditions. A significant fraction of the known pulsar population belongs to binary systems. Searching for unknown neutron stars in binary systems requires specialized algorithms to address unknown orbital frequency modulations. We present a search for continuous gravitational waves emitted by neutron stars in binary systems in early data from the third observing run of the Advanced LIGO and Advanced Virgo detectors using the semicoherent, GPU-accelerated, binaryskyhough pipeline. The search analyzes the most sensitive frequency band of the LIGO detectors, 50–300 Hz. Binary orbital parameters are split into four regions, comprising orbital periods of three to 45 days and projected semimajor axes of two to 40 light seconds. No detections are reported. We estimate the sensitivity of the search using simulated continuous wave signals, achieving the most sensitive results to date across the analyzed parameter space.

Gravitation↗

Investigating the Spatial and Temporal Limitations for Remote Sensing of Wildfire Smoke Using Satellite and Airborne Imagers During FIREX_AQ

Starting from point sources, wildfire smoke is important in the global aerosol system. The ability to characterize smoke near-source is key to modeling smoke dispersion and predicting air quality. With hemispheric views and 10-min refresh, imagers in Geostationary (GEO) orbit have advantages monitoring smoke over once-per-day sensors in low-earth orbit (LEO). However, both can be inadequate in capturing the characteristics of smoke plumes close to their sources due to too-coarse spatial resolution (both detector and product resolution), too-sparse temporal resolution (from LEO sensors), and too-conservative masking. In addition to satellite observations, the Fire Influence on Regional to Global Environments and Air Quality experiment offered sub-orbital enhanced-MODIS Airborne Simulator (eMAS) imagery at 50 m pixel resolution—including multiple eMAS flight tracks over individual fires in short time periods. It provided opportunity to explore smoke plume characterization at various spatial and temporal scales and quantify the limitations of space sensors for describing smoke magnitude near source as well as its temporal evolution. Here we applied modified aerosol algorithm to different imagers, relaxing its masking to estimate smoke's aerosol optical depth (AOD) as close as possible to its source. We found that GEO sensors with nominal 1 km spatial resolution can match the much finer resolution eMAS retrieved mean plume AOD, as long as the retrieval spatial resolution is finer than the width of the plumes. However, the plume's maximum AOD may be drastically underestimated by satellite products.

remote sensing↗

Frequency-Modulated, Continuous-Wave Laser Ranging Using Photon-Counting Detectors

Optical ranging is a problem of estimating the round-trip flight time of a phase- or amplitude-modulated optical beam that reflects off of a target. Frequency- modulated, continuous-wave (FMCW) ranging systems obtain this estimate by performing an interferometric measurement between a local frequency- modulated laser beam and a delayed copy returning from the target. The range estimate is formed by mixing the target-return field with the local reference field on a beamsplitter and detecting the resultant beat modulation. In conventional FMCW ranging, the source modulation is linear in instantaneous frequency, the reference-arm field has many more photons than the target-return field, and the time-of-flight estimate is generated by balanced difference- detection of the beamsplitter output, followed by a frequency-domain peak search. This work focused on determining the maximum-likelihood (ML) estimation algorithm when continuous-time photoncounting detectors are used. It is founded on a rigorous statistical characterization of the (random) photoelectron emission times as a function of the incident optical field, including the deleterious effects caused by dark current and dead time. These statistics enable derivation of the Cramér-Rao lower bound (CRB) on the accuracy of FMCW ranging, and derivation of the ML estimator, whose performance approaches this bound at high photon flux. The estimation algorithm was developed, and its optimality properties were shown in simulation. Experimental data show that it performs better than the conventional estimation algorithms used. The demonstrated improvement is a factor of 1.414 over frequency-domainbased estimation. If the target interrogating photons and the local reference field photons are costed equally, the optimal allocation of photons between these two arms is to have them equally distributed. This is different than the state of the art, in which the local field is stronger than the target return. The optimal processing of the photocurrent processes at the outputs of the two detectors is to perform log-matched filtering followed by a summation and peak detection. This implies that neither difference detection, nor Fourier-domain peak detection, which are the staples of the state-of-the-art systems, is optimal when a weak local oscillator is employed.

Erkmen, Baris I.↗